• Tidak ada hasil yang ditemukan

Nilai Normal Elektrokardiogram, Frekuensi Jantung, Respirasi Dan Suhu Tubuh Dugong Dugon

N/A
N/A
Protected

Academic year: 2017

Membagikan "Nilai Normal Elektrokardiogram, Frekuensi Jantung, Respirasi Dan Suhu Tubuh Dugong Dugon"

Copied!
7
0
0

Teks penuh

(1)

ISSN : 1411 - 8327

Nilai Normal

Elektrokardiogram, Frekuensi Jantung,

Respirasi

dan

Suhu Tubuh

Dugong

dugon

(NORMAL

VALUES

OF

ELECTROCARDIOGRAM,

HEART

RATE,

RESPIRATION

RATE

A N D

BODY

TEMPERATURE

OF Dugong dugon

AGIK

SUPRAYOGI',

SUMITRO~,

LINDA

TJHIN',

RIKA

SUDRANTO*

DAN

RUDA.

SALAHUDIN

DARUSMAN'

'Departemen Anatomi,

Fisiologi

dan Farmakologi,

Fakultas

Kedokteran

Hewan-IPB,

J1.

Agatis

kampus

IPB

Darmaga-Bogor, TelplFax:

0251-629462,

HP: 081310462986,

email:

asupray@yahoo.com

W .

Seaworld-Indonesia, Taman

Tmpian

Jaya

Ancol,

J1. Lodan

Timur No

7-Jakarta

14430

Telp:02

1-6410080,

Fax:

02

1-6410079,

www.seaworldindonesia.com

Drlgong dugon y a n g merupakan mammalia laut, terdaftar sebagai spesies langka yang dilindungi. Sampai

saat ini, belum banyak laporan yang tersedia tentang nilai fisiologis normal dari mammalia ini, sehingga menyulitkan dokter hewan dalam memeriksa dan mendiagnosis penyakit pada hewan ini. Oleh karena i t u ,

dilakukan studi tentang nilai normal elektrokardiogram

(EKG),

frekuensi jantung, respirasi, dan suhu tubuh dari seekor Dugong dugon dengan rnenggunakan alat pemantau pasien (patient monitor). Parameter yang diukur adalah frekuensi jantung, respirasi, suhu tubuh, dan nilai EKG: gelombang P, komplek QRS, interval PR, interval

QT,

dan mean electricity a x i s (MEA). Hasil perekaman menunjukkan bahwa nilai normal frekuensi jantung, respirasi d a n suhu tubuh berturut-turut adalah (45,73

+

4,101 denyutlmenit, ( 1 0 , l l 3,44) inspirasilmenit, dan 131,42

+

0,411 "C. Tidak ada perbedaan yang nyata antara nilai EKG normal pada hantaran I ~ d a d a kanan) dan

hantaran 11. Semcntara itu, pada hantaran III menunjukkan niiai voltase yang isoeiektris (0 mv). Pada Lend 11,

gelomhang P menunjukkan durasi (0,05 +0,02) detik degan vultase (0,03

+

0,011 mv, gelombang R menunjukkan voltasc (0,07 0,021 mv dengan durasi

QRS

komplek (0,06

+

0,01) detik, interval PR (0,26

+

0,011 detik, interval QT (0,2 1

+

0,111 detik, a x i s jantung (MEA:+90" sampai -135) condong ke kanan, dengan irama jantung reguler. Nilai normal Dugong dugon ini menunjukkan karakteristik yang spesifik dibanding nilai normal pada anjing, ha1 ini mungkin karena adanya perbedaan ekologis, struktur anatomi, dan ketebalan dinding thoraks pada

kedua hewan tersebut.

Keywords: Dugong dugon, elektrokardiogram, kardiopulmoner, suhu

ABSTRACT

Dugong dugon is a sea mammal species listed as endangered and protected species. The reports on the normal physiological values of the animal is still very limited, causing a great difficulties for veterinarians in

examining and making a proper diagnosis on the diseases affecting this mammal. A study was therefore conducted to determine the normal values of electrocardiography (ECG), heart rate, respiration rate, and body temperature of a Dugong dugon. Some important parameters such as heart rate, respiration rate, body temperature, and BCG (P-wave, QRS-complex, PR-interval, QT-interval, a n d MEA was determined by a patient monitor. Tlie result of

this study showed that the normal values of heart rate, respiration rate, body temperature were respectively

(45.73k4.10) beauminute, (10.11

+

3.44) inspiratiodminute, and (31,42 4 0,41)

"C.

No significant difference w a s

observed between the normal ECG value detected in Lead I and t h a t detected in Lead I1 (...). The normal ECG value detected in Lead III w a s isoelectric (0 mv). ECG-waves values of Lead I1 such as P-wave duration a n d

voltage were (0,05 -t- 0,021 second and (0,03

+

0,011 mv, R-waves voltage was (0,07 4 0,021 mv and duration of QRS-

complex was (0,06 f 0,011 second, PR-interval and QT-interval were (0,26 +O,Ol) second and 10,21+ 0,111 second,

MEA

value w a s +90 up to -135" to the right side, and regularly rhythm. Normal physiological values of Dugong

dugon show the specific characters compared with normal values of dogs, i t might be caused by ecological, anatomical a n d thickness of thorax wall in both animals are relatively different.

Keywords: Dugong dugon, elektrocardiogram, cardiopulmoner, temperature

(2)
(3)
(4)
(5)
(6)
(7)

Referensi

Dokumen terkait

c< Memiliki saluran pengeluaran udara ke lingkungan yang memadai atau memiliki sistem penyaringan udara yang efisien sebelum udara disirkulasikan ke ruang

Jual beli follower Twitter sama halnya dengan jual beli yang ada dalam dunia maya lainnya, yaitu jual beli yang terdapat penjual, pembeli, barang yang dijual,

Berdasarkan hasil pengujian hipotesis seperti yang telah diuraikan, dapat diambil beberapa simpulan sebagai berikut. Pertama , terdapat perbedaan pemahaman konsep

Menurut Keputusan Menteri Badan Usaha Milik Negara No KEP-117/M- MBU/2002 Pasal 1, Corporate Governance adalah suatu proses dari struktur yang digunakan oleh organ BUMN

Puji dan syukur Alhamdulillah penulis panjatkan kepada Allah SWT, karena atas rahmat dan hidayah-Nya yang telah memberikan kemudahan kepada penulis untuk menyelesaikan skripsi

- Guru mengirimkan pertanyaan kepada peserta didik melalui WAG Kelas dan Messengger Kelas tentang pengertian interaksi sosial disosiatif beserta dengan 2 contoh

Lambung kapal adalah untuk menyediakan daya apung ( bouyancy ) yang mencegah kapal tenggelam dan menyediakan displacement. Bentuk lambung kapal juga akan