transmission line

Investigation Magnetic Field Radiated By 132 kV Overhead Transmission Line.

Investigation Magnetic Field Radiated By 132 kV Overhead Transmission Line.

... A magnetic field under the transmission line can be harmful to human health. There are several researches done by researchers to prove the magnetic field could be dangerous to human. Under the lines, there ...

24

A Detection Method for Transmission Line Insulators Based on an Improved FCM Algorithm

A Detection Method for Transmission Line Insulators Based on an Improved FCM Algorithm

... a transmission line, while not conforming to the requirements for a complex ...voltage line feature extraction method based on wavelet images, which have been presented in reference [19], utilizes ...

9

Study on different types of surge arrester for 132kV overhead transmission line in shielding failure analysis.

Study on different types of surge arrester for 132kV overhead transmission line in shielding failure analysis.

... of transmission and distribution ...power line or by indirect ...the transmission line system, it is necessary to analyse such increase in voltage in order to design the surge arrester that ...

24

Simulation Of Power Transmission Line Electric And Magnetic Field Exposure.

Simulation Of Power Transmission Line Electric And Magnetic Field Exposure.

... kV transmission line is chosen with specification of the tower gained from Tenaga Nasional Berhad (TNB) ...example transmission line tower data sheet and example of 275 kV double circuit ...

24

Design and Application of Coupling Power Supply Device on Overhead Ground Wire

Design and Application of Coupling Power Supply Device on Overhead Ground Wire

... the line status, maximal 50% power of 186W can be ...with transmission line resistance is difficult to be achieved, so obtained power is considerably ...most transmission line ...

8

BACK-FLASHOVER ANALYSIS USING CONSTANT-PARAMETER DISTRIBUTED LINE (CPDL) TOWER MODEL OF 150 kV TRANSMISSION LINE (Bukit Kemuning Substation–Batu Raja Substation)

BACK-FLASHOVER ANALYSIS USING CONSTANT-PARAMETER DISTRIBUTED LINE (CPDL) TOWER MODEL OF 150 kV TRANSMISSION LINE (Bukit Kemuning Substation–Batu Raja Substation)

... the transmission lines such as, tower model, insulator model, grond wire, phase wire and grounding system based on IEEE Working Group ...Distributed Line (CPDL) tower model ...

102

Develop A 5.8ghz Antenna Using Microstrip Technologies.

Develop A 5.8ghz Antenna Using Microstrip Technologies.

... Literature review is one of the processes for developing a 5.8GHz Microstrip Antenna. As for this project, the literature review is explaining on the antenna and the basic antenna operation, microstrip antenna, ...

24

Analysis of Transmission Lightning Arrester Locations Using Tflash

Analysis of Transmission Lightning Arrester Locations Using Tflash

... electrical transmission and distribution ...improve transmission line performance, a detailed lightning study is required to analyse the corresponding lines and determine the best location for ...

7

Spectrum Comparative Study of Commutation Failure and Short-Circuit Fault in UHVDC Transmission System

Spectrum Comparative Study of Commutation Failure and Short-Circuit Fault in UHVDC Transmission System

... UHVDC transmission system, the transient process of DC voltage and current are similar to grounding short-circuit ...UHVDC transmission system, the paper simulates the commutation failure and DC line ...

10

Surge Arrester Modeling - A Comparison Between Different Models For 500KV Transmission Line.

Surge Arrester Modeling - A Comparison Between Different Models For 500KV Transmission Line.

... Switching can happen by the making and breaking of electric circuit with switchgear. It’s resulted in abnormal overvoltage in power systems [5]. There’s characteristic of switching process such as de-energizing of ...

24

Predictors of multidrug resistance among pulmonary tuberculosis patients in a tertiary hospital in North Sumatera, Indonesia

Predictors of multidrug resistance among pulmonary tuberculosis patients in a tertiary hospital in North Sumatera, Indonesia

... A retrospective study was conducted at the TB Provincial Reference Laboratory, which is based at the Department of Microbiology, Faculty of Medicine, Universitas Sumatera Utara, H. Adam Malik Hospital, and a tertiary ...

6

Karakteristik Traksi dan Kinerja Transmisi pada Sistem Gear Transmission dan Gearless Transmission.

Karakteristik Traksi dan Kinerja Transmisi pada Sistem Gear Transmission dan Gearless Transmission.

... Dari Gambar 2, yaitu pada kondisi standar masih ada jarak yang cukup jauh antara gigi I dan gigi II, sehingga ada cukup banyak traksi yang terbuang saat pemindahan rasio gigi transmisi, sedangkan antara gigi III, IV, dan ...

14

SPDT Switch Design Using Switchable Resonator At 5ghz For Wireless Communications.

SPDT Switch Design Using Switchable Resonator At 5ghz For Wireless Communications.

... Futhermore, with the SPDT switch with switchable resonator may help in reduce the power leakage between transmitter and receiver in wireless communication application such us WiFi and WLAN. SPDT with the switchable ...

24

PERANCANGAN PENGKOPEL HYBRID 3 dB UNTUK APLIKASI RADIO ALTIMETER YANG BEKERJA PADA FREKUENSI 4,3 GHz

PERANCANGAN PENGKOPEL HYBRID 3 dB UNTUK APLIKASI RADIO ALTIMETER YANG BEKERJA PADA FREKUENSI 4,3 GHz

... In this research, a 3 dB hybrid coupler has been developed for altimeter radio with operating frequency at 4,3 GHz using exponential tapered transmission line on its series arms, hence impedance ...

11

Desain dan Implementasi Rectenna Hexagonal Patch Array pada Frekuensi 2,4 GHz

Desain dan Implementasi Rectenna Hexagonal Patch Array pada Frekuensi 2,4 GHz

... Metode corporate feed line digunakan secara umum dan banyak diaplikasikan dalam berbagai bidang. Metode ini memiliki kontrol saluran di setiap patch dan sesuai pada penggunaan saluran yang meruncing kedua ujungnya ...

6