• Tidak ada hasil yang ditemukan

BUS STOP STANDARDS

N/A
N/A
Protected

Academic year: 2023

Membagikan "BUS STOP STANDARDS"

Copied!
1
0
0

Teks penuh

(1)

SHEET OF WORKS JOB No.

DRAWING No. AMEND.

LEVEL DATUM

MERIDIAN SURVEY FILE No SURVEY

MANAGER TECHNICAL SERVICES G. HAWES RPEQ 5693 DATE

DRAWN

DESIGNED

CHECKED SIGNED SIGNED SIGNED

AMENDMENTS AND REVISIONS DESCRIPTION

DATE APPVD

ENGINEERING AND

JASON DEVITT DATE DIRECTOR

DATE DATE DATE

COMMERCIAL INFRASTRUCTURE

1 1

A3-00874 B STANDARD

BUS STOP STANDARDS

SIGNATURE STOP (URBAN)

STANDARD DRAWINGS\A3-00874.DWG

C.BROWN on behalf of 12.8.10

SIGNED RPEQ 6430

12/8/10 A 4/12/18 AMENDED

B 7.12.18 DISABLED PAVEMENT MARKING NOT REQ'D GH

DISTANCE TO BE DETERMINED ONSITE

14.4 MIN. (LENGTH MAY VARY)

0.750.3

20.0 10.0

YELLOW BUS STOP MARKING AS PER REGULATIONS (IF REQUIRED DUE TO RESTRICTIONS ON ROAD HIERARCHY WIDTHS)

PROPERTY BOUNDARY

LEGEND:

SHELTERS & SEATS

MIN 1.2

J - POLE STYLE BUS STOP SIGN

0.3

MIN 1.2

MINIMUM VERGE WIDTH IS 3.145

KERB & CHANNEL

WHERE VERGE WIDTH ALLOWS, SHELTERS MAY BE PLACED BACK TO BACK. MINIMUM CLEARANCES STILL APPLY.

KERB & CHANNEL

MIN 1.2 MINIMUM VERGE WIDTH 5.35

0.3

0.5

2.5 MIN

LIGHT POLE

2.5

NOTES:

1. BUS STOP GRADIENT AT BOARDING POINT TO BE 1:40 AND ALL OTHER AREAS TO ACHIEVE A GRADIENT OF 1:20 TO COMPLY WITH DISABILITY STANDARDS.

2. 1.2m MINIMUM (1.5m DESIRABLE) CLEARANCE TO ALL ACCESSIBLE SIDES OF INFRASTRUCTURE TO ALLOW DISABLED ACCESS.

3. CONCRETE SLAB TO BE 125mm THICK AND BROOM FINISHED (FOR SLIP RESISTANCE). GRADE N25 CONCRETE. RF72 REINFORCING MESH TO BE PLACED CENTRALLY OR AN EQUIVALENT FIBRE REINFORCED CONCRETE SLAB. FOR SHETLER FOOTINGS REFER STD DWG A3-860.

4. BUS STOP SHELTER TO BE 3.5m X 1.5m C3 RATED AND SUPPLIED BY G.

JAMES FURNITURE. REFER A3-00859 & A3-00860 FOR SHELTER DETAILS. A SIGNATURE STOP MAY CONTAIN THREE (3) OR MORE SHELTERS

5. BUS STOP SIGN TO BE J-POLE TYPE. REFER STD DWG A3-863 FOR DETAILS.

6. SEAT TO BE RIVERSIDE TYPE & SUPPLIED BY G. JAMES FURNITURE. SEAT TO BE CLEAR ANNODISED PLANKS ON BLUE POWDERCOATED FLANGE MOUNT LEGS.

7. TACTILE GROUND SURFACE INDICATORS (TGSI) SHOULD BE INSTALLED PERPENDICULAR TO THE KERB AND ACROSS THE FULL WIDTH OF THE PATH OF TRAVEL. ALL FURNITURE SHOULD BE A MINIMUM 300MM CLEAR OF TGSI'S. TGSI TO COMPLY WITH AS1428.

8. KERB RAMP & CONNECTOR PATH MUST BE PROVIDED IF THERE ARE NO ACCESS PATHS CONNECTING BUS STOP TO FOOTPATH OR FACILITIES SERVICED BY THE STOP. REFER A2-576 FOR KERB RAMP DETAILS.

9. BUS STOP LIGHTING & CONDUITS TO BE IN ACCORDANCE WITH AS1158.

10. REFUGE COLLECTION FACILITY SHALL BE PROVIDED AND IS TO BE A STANDARD MACKAY REGIONAL COUNCIL BIN. COLOUR TO BE DETERMINED BY PRECINCT LOCATION.

11. SHELTER ROOF WATER TO BE TAKEN TO THE GROUND WITH A DISCHARGE SPREADER AT GROUND LEVEL. DISCHARGE TO BE AIMED AWAY FROM SHELTER.

12. WHERE LANDSCAPING PROVIDED, USE ONLY GROUND COVER OR LOW SHRUBS (<0.5M HIGH).

13. MINIMUM VERGE WIDTHS ALLOW SIGNATURE STOP TO BE COMPLIANT WITH THE DISABILITY DISCRIMINATION ACT.

14. DIMENSIONS ARE IN METRES UNLESS NOTED OTHERWISE.

SIGNATURE STOP

NTS

EXISTING CONCRETE FOOTPATH

SLAB WIDTH VARIES TO SUIT VERGE

2.0 MIN

BIN

PROPERTY BOUNDARY

BUS STOP SIGN J - POLE STYLE

TACTILE GROUND SURFACE INDICATORS RIVERSIDE SEAT KERB RAMP &

CONNECTOR PATH

Referensi