CE 318
STRUCTURE ANALYSIS AND DESIGN II LAB
LECTURE 6
RCC COLUMN DESIGN
SEMESTER: SPRING 2021
COURSE TEACHER: SAURAV BARUA CONTACT NO: +8801715334075
EMAIL: [email protected]
LECTURE PLAN
2 copyright @Saurav Barua
Column load calculation
Contributory area
Bending factor
COLUMN LAYOUT
COLUMN CONTRIBUTORY AREA
copyright @Saurav Barua 4
CONTRIBUTORY AREA
• Take ½ span from each side to calculate contributory area
• Then designate columns of similar column contributory into same name, i.e. C1, C2, C3 and C4
• Contributory area of corner column C1 = (½ x 15’) x (1/2 x 16’)
= 7’-6” x 8’ = 60 sft
CONTRIBUTORY AREA
• Contributory area of edge column C2 = (½ x (15’+18’)) x (1/2 x 16’)
= 16’-6” x 8’ = 132 sft
• Contributory area of edge column C3 = (½ x 15’)x (1/2 x (16’+16’))
= 7’-6” x 16’ = 120 sft
• Contributory area of central column C4 = (½ x (15’+18’)) x (1/2 x (16’+16’))
= 16’-6” x 16’ = 264 sft
copyright @Saurav Barua 6
DEAD LOAD CALCULATION
• Slab weight = 6/12 x 0.15 = 0.075 ksf
• Wall load (WL) = 80psf = 0.08ksf
• Floor finish (FF) = 25psf = 0.025ksf
• Beam weight = [(15’ + 18’+ 15’) x 3 + (16’+ 16’) x 4] x (12 x 18)/144 x 0.15
= [48 x 3 + 32 x 4] x (12 x 18)/144 x 0.15
= 61.2 kip/ (48 x 32) = 0.04ksf [Explained in class!!]
Column weight = 12 x 20 /144 x 10 x 12x 0.15 [ 12 nos. column of 12”x 20” assumed]
= 30kip/ (48 x 32) = 0.02ksf
• DL = 0.075 + 0.08 + 0.025 + 0.04 + 0.02
= 0.24ksf
LL = 40 psf = 0.04 ksf
Since, we will design column considering axially loaded column formula For central column C4 factor for bending moment = 1.0
For edge columns C2, C3 factor for bending moment = 1.1 For corner column C1 factor for bending moment = 1.3 This will reduce original effect of biaxial bending
Consider 10% of DL for Earthquake load and 15% of DL for Wind load.
copyright @Saurav Barua 8
Column
Contributory
area (sft) Story Total contributory area (sft)
C1 60 6 360
C2 132 6 792
C3 120 6 720
C4 264 6 1584
Total contributory area = contributory area x story
• Consider wind and earthquake combined 25% of DL and apply this load as part of DL. So, multiply DL by 1.25.
copyright @Saurav Barua 10
DL (ksf)
Factor for WL and
EQ
Calculated DL
C1 0.24 1.25 0.3
C2,C3 0.24 1.25 0.3
C4 0.24 1.25 0.3
DL (ksf) LL (ksf)
Factored 1.4 DL+
1.7 LL (ksf)
bending factor
factored load
considering bending,
ksf
C1 0.3 0.04 0.49 1.3 0.63
C2,C3 0.3 0.04 0.49 1.1 0.54
C4 0.3 0.04 0.49 1 0.49
C1 corner column; C2, C3 edge column and C4 middle column