DISOLUSI TERBANDING TABLET RANITIDIN PRODUK GENERIK BERLOGO DAN PRODUK BERMEREK TERHADAP

PRODUK OBAT INOVATOR DALAM LARUTAN DAPAR SITRAT pH 4,5

Ella, 2009

Pembimbing: (I) Ni Luh Dewi Aryani , (II) Nani Parfati

ABSTRAK

Ranitidin merupakan salah satu obat yang mudah larut dalam air, termasuk dalam BCS kelas 3 yang memerlukan uji ekivalensi in vitro. Pada penelitian ini dilakukan uji disolusi terbanding Ranitidin dari produk obat generik berlogo dan bermerek terhadap produk inovator yang berfungsi sebagai pembanding dalam larutan dapar sitrat pH 4,5. Larutan dapar sitrat pH 4,5 merupakan simulasi dari kondisi pH diantara lambung dan usus halus. Penentuan laju disolusi Ranitidin dilakukan menggunakan metode paddle atau alat tipe 2 pada suhu 370C ± 0,50C dan parameter yang diamati adalah faktor kemiripan dan efisiensi disolusi. Hasil penelitian didapatkan bahwa produk obat generik berlogo ekivalen dengan produk obat inovator, nilai faktor kemiripan (f2) dari produk generik berlogo

adalah 63,29 Sedangkan produk obat bermerek tidak ekivalen dengan produk obat inovator, dengan nilai faktor kemiripan (f2) dari produk obat bermerek adalah

44,49. Nilai efisiensi disolusi produk obat inovator, produk obat generik berlogo, dan produk obat bermerek adalah 91,93%, 91,91%, dan 99,69% yang menunjukkan bahwa produk obat uji tidak memiliki perbedaan bermakna dengan produk obat pembanding.

(2)

vii

DISSOLUTION COMPARED OF RANITIDINE TABLETS FROM GENERIC PRODUCT AND BRANDED PRODUCT TO THE INNOVATOR MEDICINE PRODUCT IN SITRATE BUFFER

CONDENSATION 4,5 Ella, 2009

Lecturers: (I) Ni Luh Dewi Aryani , (II) Nani Parfati

ABSTRACT

Ranitidine represent one of easy dissolve drug in water, included in BCS class 3 requires in vitro equivalence test. In this research, the examination test is done towards drug product that is generic product and branded product compared to innovator product through dissolution test compared in citric buffer pH 4,5. Citric buffer 4,5 is the simulation of between stomach and intestine condition. The determination dissolution rate of ranitidine is conducted using paddle method or apparatus type 2 at temperature 370C ± 0.50C and parameters that perceived are dissolution profile and dissolution efficiency. The result of this research got that generic product is equivalence with comparator product, similarity factor (f2) of

generic product is 63,29 and branded product is not equivalence with comparator product, similarity factor (f2) of branded drug product 46,49. Dissolution

efficiency value of innovator, generic and branded drug product are 91,93%, 91,91%, and 99,69% respectively indicating that test drug product has no meaningful difference with comparator drug product.

Referensi

Dokumen terkait

Hasil penelitian didapatkan bahwa disolusi tablet asetaminofen masing-masing produk baik obat generik berlogo maupun produk bermerek menunjukkan gambaran profil

Pada penelitian ini, dilakukan pengujian terhadap produk obat uji yaitu produk obat bermerek dan produk obat generik berlogo dibandingkan terhadap produk obat

Uji disolusi terbanding merupakan uji pendahuluan dari uji bioekivalensi in vivo yang dilakukan pada rifampisin produk uji (bermerek dan generik berlogo) dengan produk

Disolusi terbanding dilakukan antara produk uji (generik dan bermerek) terhadap produk pembanding (inovator) dalam larutan dapar HCl pH 1,2 yang merupakan simulasi dari

Pada penelitian ini, dilakukan pengujian terhadap produk obat uji yaitu produk obat generik dan bermerek dibandingkan terhadap inovator melalui uji disolusi

Pada penelitian ini, Uji disolusi dilakukan pada produk bermerek (A) dan produk generik berogo (B) sebagai produk uji dengan produk inovator (C) sebagai

Uji disolusi terbanding dilakukan antara produk uji (generik berlogo dan generik bermerk) terhadap produk pembandingnya (inovator) menggunakan larutan dapar HCI pH 1,2

Disolusi terbanding tablet metformin hidroklorida generik berlogo dengan generik bermerek yang berasal dari pabrik yang sama memiliki kemiripan (produk B dan C). Kedua