PT PEMBANGKITAN JAWA BALI UNIT BISNIS JASA O & M PLTU PACITAN PENGUMUMAN PELELANGAN SEDERHANA ULANG

Nomor : 193U.PM/612/UJPC/2014

Panitia Pengadaan Barang/Jasa PT PJB UBJ O&M PLTU PACITAN mengundang penyedia barang/jasa untuk mengikuti Pelelangan Sederhana sebagai berikut :

1. Paket pekerjaan

Nama Pekerjaan : Pengadaan Function Generator Nilai Total HPS : Rp 73.350.000,- (termasuk PPN 10%)

Sumber Dana : Anggaran Investasi PT PJB UBJ O&M PLTU PACITAN tahun 2014 2. Syarat Peserta Lelang:

a. Perusahaan berbadan hukum dengan kualifikasi sub bidang Mekanikal dan Elektrikal/listrik; b. Pabrikan (Manufacture) / Agen Resmi dari produk yang ditawarkan;

c. Penyedia barang/jasa harus mendapat dukungan dari pabrikan (manufacture)/Agen Resmi yang berpengalaman dalam bidang pengadaan barang sejenis;

d. Penyedian Barang/jasa memiliki pengalaman paling sedikit 1 (satu) kali menyediakan barang sejenis dalam kurun waktu selama 4 tahun terakhir, termasuk pengalaman sub kontrak dengan hasil baik, kecuali untuk penyedia yang baru berdiri kurang dari 3 (tiga) tahun tidak diwajibkan memiliki pengalaman. Pengalaman tersebut dibuktikan melalui :

1. Surat perintah Kerja/kontrak pekerjaan; 2. Berita Acara Serah Terima barang;

3. Sub kontrak yang diketahui oleh pengguna jasa/pemilik barang

e. Penyedia Barang/Jasa tidak sedang menjalani sanksi blacklist di lingkungan PT PLN (Persero) Group. 3. Pendaftaran dan Pengambilan Dokumen Pengadaan

Hari/Tanggal : 28 Mei s/d 4 Juni 2014 Waktu : 09.00 s/d 15.00 WIB

Tempat : PT. PJB UBJOM PLTU PACITAN

Jl Raya Pacitan-Trenggalek Km. 55 Pacitan

Contact Person : Satrio A./ Okta 082 230 633 455 / 0357 3213116 Email : pengadaan.pltupacitan@gmail.com

4. Pendaftaran dan pengambilan dokumen pengadaan dapat diwakilkan dengan membawa surat tugas dari direktur utama/pimpinan perusahaan/kepala cabang dan kartu tanda pengenal perusahaan.

5. Seseorang dilarang mewakili lebih dari 1 (satu) perusahaan dalam mendaftar dan mengambil dokumen pengadaan.

6. Penyedia yang mendaftar untuk ikut pelelangan namun tidak memasukkan dokumen penawaran tanpa alasan yang profesional akan dikenakan sanksi blacklist selama 6 (enam) bulan.

Pengumuman ini bukan merupakan ikatan yang dapat mengakibatkan kewajiban finansial kepada PT Pembangkitan Jawa Bali.

Pacitan, tanggal 28 Mei 2014 PENGADAAN BARANG/JASA PT.PJB UBJOM PLTU PACITAN

(2)

Lampiran Pengumuman Lelang Sederhana No. 193U.PM/612/UJPC/2014

Tgl. 28 Mei 2014

SPESIFIKASI BARANG YANG DIMINTAKAN PENAWARAN

NO. NAMA BARANG JUMLAH

1

SKI-Function Generator

General Features Function Generator :

Only 20 MHz built-in WaveGen function generator Only economy-class scopes with mixed-signal capability

8.5" WVGA display with 2X the viewing area and 5X the resolution Up to 50,000 Waveform updates/second

Fully upgradable: bandwidth, MSO, measurement applications and WaveGen Features :

1. WAVE FUNCTION GENERATOR :

A. Measure Waveforms Sine, square, pulse, triangle, ramp, noise, DC a.Sine: Frequency range: 0.1 Hz to 20 MHz, Amplitude flatness: ±0.5 dB (relative to 1 kHz), Harmonic distortion: –40 dBc

b.Square wave/pulse : Frequency range: 0.1 Hz to 10 MHz, Duty cycle: 20 to 80%, Duty cycle resolution: Larger of 1% or 10 ns, Pulse width: 20 ns minimum

c.Ramp/triangle wave: Frequency range: 0.1 Hz to 100 kHz, Linearity: 1%, Noise Bandwidth: 20 MHz typical

d.Frequency:

Sine wave and ramp accuracy: 130 ppm (frequency < 10 kHz), 50 ppm (frequency > 10 kHz)

Square wave and pulse accuracy: [50+frequency/200] ppm (frequency < 25 kHz), 50 ppm (frequency ≥ 25 kHz) Resolution: 0.1 Hz or 4 digits, whichever is larger

e.Amplitude:

Range: 20 mVpp to 5 Vpp into Hi-Z, 10 mVpp to 2.5 Vpp into 50 ohms, Resolution: 100 µV or 3 digits, whichever is larger, Accuracy: 2% (frequency = 1 kHz)

f.DC offset:

Range: ±2.5 V into Hi-Z, ±1.25 V into 50 ohms g.Resolution: 100 μV or 3 digits, whichever is larger

Accuracy: ±1.5% of offset setting ±1.5% of amplitude ±1 mV h.Accuracy: ±1.5% of offset setting ±1.5% of amplitude ±1 mV B.Trigger output: Trigger output available on Trig out BNC C.Modulation

a.Modulation types: AM, FM, FSK b.Carrier waveforms: sine, ramp

c.Modulation source: Internal (no external modulation capability 1. FREQUENCY SIGNAL MEASUREMENT:

A. General :

(3)

Bandwidth * (–3 dB) 200 MHz

“Calculated rise time (10-90%)” ≤ 1.75 ns Input channels DSOX 4

MSOX 4 + 8

Maximum sample rate 2 GSa/s half-channel interleaved, 1 GSa/s per channel

Maximum memory depth 100 kpts per channel (standard), 1 Mpt per channel (optional with DSOX2MEMUP)

Display size and type 8.5-inch WVGA with 64 levels of intensity grading Waveform update rate > 50,000 waveforms per second

B. Vertical system analog channels : Input coupling AC, DC

Input sensitivity range 1 mV/div to 5 V/div** Input impedance 1 MΩ ± 2% (11 pF) Vertical resolution 8 bits

Dynamic range ±8 divisions from center screen

Maximum input voltage : CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk, CAT II 300 Vrms, 400 Vpk; with N2862B or N2863B 10:1 probe: 300 Vrms

DC vertical accuracy ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale] **

DC vertical gain accuracy* ±3% full scale (≥ 10 mV/div); ±4% full scale (< 10 mV/div) **

DC vertical offset accuracy ±0.1 div ± 2mV ±1% of offset setting

Channel-to-channel isolation: 200 MHz ~ 1 GHz ≥ 40 dB from DC to maximum specified bandwidth of each model , 1.5 GHz ≥ 40 dB from DC to 1 GHz, ≥ 35 dB from 1 GHz to 1.5 GHz

Position/offset range 1 MΩ 1 mV to 200 mV/div: ±2 V, > 200 mV to 5 V/div: ± 50V

Hardware bandwidth limits Approximately 20 MHz (selectable) C. Horizontal system analog channels :

Time base range 2 ns/div to 50 s/div Horizontal resolution 2.5 ps

Time base accuracy* 25 ppm ±5 ppm per year (aging)

Time base delay time range: Pre-trigger Greater of 1 screen width or 200 μs (400 μs in interleaving mode),Post-trigger 1 s to 500 s

Channel-to-channel deskew range ± 100 ns

Δ Time accuracy (using cursors) ± (time base accuracy* reading) ± (0.0016 * screen width) ± 100 ps

D. Waveform math

Operators Add, subtract, multiply, FFT

FFT Windows: Hanning, flat top, rectangular; Blackman-Harris - up to 64 kpts resolution

(4)

E. Display characteristics Display 8.5-inch WVGA

Resolution 800 (H) x 480 (V) pixel format (screen area)

Interpolation Sin(x)/x interpolation (using FIR filter; used when there is less than one sample per column of the display)

Persistence Off, infinite, variable persistence (100ms-60s) Intensity gradation 64 intensity levels

Modes Normal

XY - XY mode changes the display from voltage versus time scale to a volts versus volts scale

Roll – Displays the waveform moving across the screen from right to left much like a strip chart recorder

F. MSO (digital channels) Upgradable from DSO Yes

MSO channels 8 channels (D0 to D7) Maximum sample rate 1 GSa/s

Maximum record length 50 kpts per channel (digital channels only) 12.5 kpts per channel (analog and digital channels)

Threshold selections TTL (+1.4 V), CMOS (+2.5 V), ECL (-1.3 V), User-definable (±8.0 V in 10 mV stops)

Threshold accuracy* ± (100 mV + 3% of threshold settings) Maximum input dynamic range :±10 V about threshold Minimum voltage swing 500 mVpp

Input impedance 100 kΩ ± 2% at probe tip, ~8 pF Minimum detectable pulse width :5 ns

Channel-to-channel skew 2 ns (typical), 3 ns (maximum) G. Cursors

Types Amplitude, time , frequency (FFT), manual, tracking, binary, HEX Measurements ΔT, 1/ΔT, ΔV/X, 1/ΔX, ΔY, Phase and Ratio

Cursors** • Single cursor accuracy:

±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]

• Dual cursor accuracy:

±[DC vertical gain accuracy + 0.5% full scale]* H. Automatic waveforms measurements

Voltage Snapshot all, maximum, minimum, peak-to-peak, top, base, amplitude, overshoot, preshoot, average- N

cycles, average-full screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N cycles

Time Period, frequency, rise time, fall time, + width, – width, duty cycle, delay A→B (rising edge), delay A→B

(falling edge), phase A→B (rising edge,) and phase A→B (falling edge)

Include :

1. Dilengkapi dengan COO / COM

2.

Dilengkapi dengan sertifikat kalibrasi

(5)

Referensi

Dokumen terkait

(pemborongan) dalam kurun waktu 3 (Tiga) tahun terakhir (dari tahun 2009 sampai dengan 2012) baik dilingkungan Pemerintah atau Swasta termasuk pengalaman sebagai sub

Selama 4 (empat) tahun terakhir pernah memiliki pengalaman menyediakan barang baik dilingkungan pemerintah atau swasta, termasuk pengalaman sub kontrak baik dilingkungan

Selama 4 (empat) tahun terakhir pernah memiliki pengalaman menyediakan barang/jasa baik di lingkungan pemerintah atau swasta termasuk pengalaman subkontrak baik di

8 Bukti telah memiliki pengalaman menyelesaikan pekerjaan sejenis sekurang-kurangnya satu kali dalam kurun waktu tujuh tahun terakhir dihitung dari tanggal

memperoleh paling sedikit 1 (satu) pekerjaan sebagai penyedia dalam kurun waktu 4 (empat) tahun terakhir, baik di lingkungan pemerintah maupun swasta termasuk pengalaman

memperoleh paling kurang 1 (satu) pekerjaan sebagai Penyedia Barang/Jasa dalam kurun waktu 4 (empat) tahun terakhir baik di lingkungan pemerintah maupun swasta, termasuk

Memiliki pengalaman dalam kurun waktu 15 tahun terakhir untuk pekerjaan sejenis Jasa Konstruksi Pembangunan Gudang dan/atau Pembangunan Gedung dengan nilai kontrak minimal 1/3 dari