OPTIMALISASI

INSTALASI PENGOLAHAN AIR LIMBAH (IPAL) PT. BEHAESTEX PANDAAN- PASURUAN)

Silvia Dwika Puspita

Junaidi, ST dan Ir. Mochtar Hadiwidodo

ABSTRACT

PT. Behaestex have had Wastewater Treatment Plant (WWTP) that treatment processes consist of physics-chemical treatment and activated sludge biological treatment. Effluent of WWTP have appropriated for waste water standard according to decision letter of East Java Governor No. 45 in 2002’s, except colour parameter. Effluent of WWTP still have high colour content. Another problem is effluent from physics-chemical treatment still have high pH and temperature. The temperature range is in 35 to 45°C and pH range is in 10 to 11. Optimalization of PT. Behaestex WWTP was done aiming to reduce colour content in wastewater, adjusted to neutral pH between 6,5 to 7,5 and reducing temperature to be less than 30°C. Optimalization that can be done are optimizing coagulation-floculation unit with determination the dosage of coagulant that effective to reduce colour content. Result of optimalization indicated that the most effective coagulant to reduce colour content is ferrous sulfate with 500-6000 mg/l dosage. The type of Cooling tower to be used is induced draft crossflow cooling tower and pH adjustment with sulfate acid 98% with total requirement 35,8 L/day.

Referensi

Dokumen terkait

Terdapat button untuk penambahan tawas bila diinginkan, namun hanya dapat dilakukan bila mode operasi yang dipilih adalah mode manual. Jumlah tawas yang dilarutkan per

The solution that can be implemented to optimalize the operation of this instalation are redesign the instalation to advance the treatment procces of wastewater, add the

Pengolahan juga tidak efisien disebabkan oleh waktu detensi yang sangat singkat dan debit yang masuk sangatlah banyak, maka dari itu diperlukan

The evaluation result shows that IPLT of Blora needs to expand its service area, make regulation about IPLT management, explicit distribution of duty and responsobility and

IPAL yang akan dioperasikan, efluennya harus memenuhi standar baku mutu yang ditetapkan oleh pemerintah daerah setempat yaitu Peraturan Daerah Propinsi Jawa Tengah Nomor 10 tahun

The evaluation result shows that IPLT of Karanganyar needs to expand service area, make regulation about IPLT management and WC suction duty, repair treatment units and repair

Mengingat potensi sumber air baku untuk pengembangan pelayanan air bersih Kecamatan Kandeman Kabupaten Batang hanya Sungai Kaliboyo yang melintasi wilayah Kecamatan Tulis