(1)

PERALATAN PONEK RUMAH SAKIT PERALATAN NEONATAL

1 Inkubator Baby 2 unit

FEATURES

* Micro Processed display panel. * Two Automatic temperature system * Air Temperature control ( ATC ) * Infant Temperature Control (ITC )

* Ope ates ith a high te pe atu e of . / . F * Servo-control system

* Alarm indicator for Hyperthemia , Air circulation failure , Power failure, Skin sensor failure and disconected senor

* Automatic self-test function

* Exclusive duct for air passageway with easy access for cleaning and with an opening for the external air entrance to hood reduce the concentrations of CO² that exhale inside the hood

* Transparent acrylic hood with a dumping system for safe closure

* Wide patient visualization, opening frontal door for intensive care, portholes opening with just an elbow touch.

* Non-toxic and flexible garrison for passing tubes and cords, 2 external levers for the bed movements of trendelemburg,trendelemburg reverse low horizontal and high horizontal

* Radiotransparent bed for X-rays procedures * Oxygen inlet control through limited valve

* External system of air humidification inside the hood, removable water reservoir, removable ice drawer, air filters.

* Noise level inside the hood < 60 dBa as per International Standards * Electric voltage of (110 - 130 / 220 - 230 V~)

SPECIFICATION

Physical Specifications :

* Length 1000 mm

* Width 590 mm

* Height 1400 mm

* Weight 57 Kg

Power Supply

* AC Power Supply 110 - 130 V / 220 - 230 V

* Frequency 50/60 Hz

* Number of Phase Single Phase

* Fuse 5A (127V net) / 3A (220V net)

Classification of the product as per ANVISA

* Fitting Class III (High Risk)

Classification of the product as per NBR IEC60601-1 Standard (Againts Electric Discharge)

* Type of Protection Class I

* Level of Protection Equipment BF Type

* Noxious Penetration of Water IPX – Co o E uip e t E uip e t losed protected againts leakage of water)

* Safe level of application in the Not adequate presence of an anesthetic mixture

inflammable with the air, oxygen or nitrous oxide

* Operation Mode Continous

Display

* Dimension 21 mm x 85 mm

DAFTAR ALAT & SPESIFIKASI

QTY

SPESIFIKASI

(2)

* Type LCD

* Display Setting LED - Seven Segment (Double)

Environmental Specification Conditions of Operations

- Ambient Temperature 20°C - 30°C

- Relative Humidity 30% - 75% Non-Condensing

- Atmospheric Pressure 700 hPa - 1060 hPa (525 mmHg - 795 mmHg) Conditions of Storage

- Ambient Temperature 0°C - 55°C

- Relative Humidity 0% 90% Non-Condensing

- Atmospheric Pressure 500 hPa - 1060 hPa (325 mmHg - 795 mmHg) Parameter Specification

Potency of the heating element 300 Watts Nominal potency of entrance (Total) 400 V.A. Working Range Specification

ATC Mode

- Working Range 28°C - 37°C

- Extended Working Range 37° C - 39°C ITC Mode

- Working Range 35°C - 37,5°C

- Extended Working Range 37,5°C - 39°C

• Reading Range 0°C - 50°C

(indication at temperature displays)

• Accuracy Reading Range of 30°C - 37,5°C conformity

• Programming resolution and 0,1°C displays indication

• Maximum error of Newborn +/- 0,3°C temperature

• Maximum error of temperature +/- 1,5°C control(Between 21°C and 25°C )

• Time of heating to reach 36° Maximum of 30 minutes from an ambient temperature of 25°C

• Thermostat (working thermometer) Electronic microprocessed

• Thermo limiter Electronic

(safety thermometer)

• Occupied area 0,432 m3

• Mattress Non-toxic and anti allergic

• Mattress Dimensions 0,580 x 0,285 x 0,030 m

• Electronic system Microprocessed

Standard Accessories 1 Ea I.V. Stand, 1 Ea Humidifier Standard Part

4 Ea swivel casters with 2 brakes 1 Kit Oval Portholes (Kit with 04 Doors)

2 Infant Warmer 2 unit

Specifications :

• Fitting : Class III (High risk)

• Classification of the product as per NBR IEC 60601-1 Standard • Type of pRotection againts Electric Discharge : Class I

• Level of Protection againts Electric Discharge : Equipment BF type

• Protection againts harmful Penertaion of water : IPX0-Common equipment • Safe level applciation in the presence of an anesthetic mixture : Not adequate • Inflammable with the air oxygen or nitrous oxide

• Operating mode : Continuous

(3)

• Range of ambient temperature operation : +18°C to + 30°C • Range of ambient temperature recommed : +21°C to +26°C • Speeding of air ambient : 0.3m/s (max)

• Range of realtive humidity of operation : 30% to 75% (non-condensing) • Range of atmospheric pressure of operation : 700hPa (525 mmHg to 795mmHg) • Ambiental condtions of ttransport or storage

• Range of ambient temperature or storage : 0°C to +55°C

• Range relative humidity to transport or stroage : 0% to 90% (non - condensing) • Range of atmospheric pressure of transport or storage : 500hPa

(375mmHg to 795mmHg)

• Fedding tension : 110-130V ~ 220-230V • Frequency : 50/60Hz

• Potency of the warming element : 650 Watts • Potency aucillary lightling : 18 watt

• Nominal potency of entrance (total) : 800VA

• Working range (control mode) : Manual (Potency) con trolled newborn (RN) • Working range (Manual mode) : From 0% to 100%

• Working range (Newborn mdoe) : from 35°C to 38°C

• Reading range (Indication on the display of temperature) : From % to 50°C • Resolution of programming and indicator of the newborn temperature : +/-0.3°C

3 Pulxe Oxymeter Neonatus 2 unit

Specifications :

▪ Accurate during motion and low perfusion

▪ SpO2, pulse rate, alarm, plethymographic waveforms display and up to 72 hours of patient trends

▪ Manage data on PC via USB ▪ Audible and visual alarms

▪ 24 hours battery life, with low battery indicator ▪ Monitor adult,pediatrics and neonates

▪ Bright LCD with large digital numerics ▪ BCI compatible probe

Measurement Range

Pulse rate : 25 to 250 bpm

%SpO2 : 0 to 100%

Perfusion : 0.1 to 20% Saturation Accuracy

Without motion Adult : 70% to 100% ±2 digits Neonates : 70% to 100% ±3 digits With motion Adult : 70% to 100% ±3 digits Neonates : 70% to 100% ±4 digits

Pulse Rate Accuracy

Without motion : 25 to 250 bpm ±3 digits With motion : 25 to 250 bpm ±5 digits Instrument

AC Power requirements : 100 to 240 VAC, 50/60Hz Power Consumption : 24 VA

Fuse Rating : 1 Amp, 250V Battery

Type : Li-ion

Capacity : up to 24 hours Charging time : 5 hours Enviromental

Operating Temperature : 50C to 400C Storage Temperature : -200C to 700C Operating Huminity : 5% to 95%

Operation Altitude : -1,000 ft to 12,000 ft Physical Characteristics

(4)

EN865

EN/IEC 60601-1-2

Alarms : Audible and visual alarms for high and low saturation, pulse rate, sensor condition, system failure and low battery

Display/Indicators : Type-grey / blue LCD Pixels-240 x 64 dots Dot Pitch - 0.53mm

Data display : %SpO2, pulse rate, %SpO2 limits, pulse rate limits, pleth waveform,alarm status,trends,Battery status,time Output Interface : Serial USB

Trend Memory : Saturation and pulse rate memories(72 hours maximum) Standard Accessories : Reusable adult spo2 sensor

4 Phototherapy 1 unit

Specifications :

● Class Classifications Class 2 : Medium risk ● Feeding tension : 127 or 220 VAC ● Feeding frequency : 50 / 60 Hz

Total potency : 160 Watt

● Specter of emitted radiation : 400 - 550nm ● Quantity lamp fluorescent @ 20 Watt :

4 Special blue lamp, 4 White lamp (daylight) ● Durability of the light bulbs

● Blue spesial : 2000 hour ● White day light : 250 hours ● Caster : 3 Castor

● Distance between the bulb to the floor - Max : 1870cm

- Min : 1245cm

5 Syringe Pump 2 unit

Specifications :

● Flow rate range : 0.1 - 2000 ml/h for 50 ml syringe 0.1 - 1200 ml/h for 30 ml syringe 0.1 - 1000 ml/h for 20 ml syringe 0.1 - 600 ml/h for 10 ml syringe (programmable in 0.1 ml/h steps) ● Volume to be infused : 0.1 - 1000 ml

● Maximum bolus rate : 2000 ml/h for 50 ml syringe 1200 ml/h for 30 ml syringe 1000 ml/h for 20 ml syringe 600 ml/h for 10 ml syringe ● Bolus dose / induction : Limited to syringe size

doeses

● Mass units programming : Units available : ml/h, µg/h, mg/h, µg/kg/h, mg/kg/h, µg/kg/min, mg/kg/min

● Drug concentration : 0.01 µg/ml - 1000 mg/ml ● Patient weight : Up to 300 kg

● Infusion time : Up to 100 h

● KVO rate : 0.1 - 5 ml/h, programmable in 0.1 ml/h steps ● Flow rate accuracy : ± 2% (complies with EN 60601 - 2 - 24)

● Occlusion pressure limit : User selectable 40-120kPa,programmable in 20kPa steps ● Compatible syringes : 10, 20, 30 and 50 / 60 ml

● Syringe brands : Multi Various Brand

(5)

infusion or till the syringe gets empty, low battery Technical Specifications :

● Power supply : 230 VAC ± 10%, 50/60 Hz, max. 10 VA or from a built-in rechargeable battery

● Power consumption : Max. 10 VA

● Built - in battery : Rechargeable, Nicd of increased durability (940 mAh) ● Battery life : 20 h at a flow rate of 5 ml/h

● Battery charging time : 36 h

● Electrical safety : Class I, type BF, IPX1 ● Conformity standards : EN 60601 - 1

EN 60601 - 1 - 2 (EMC) EN 60601 - 2 - 24 MDD 93 / 42 / EEC

● Operating conditions : 5 - 400C, relative humidity : 20 - 90% Other features :

● Computer Interface : RS 232C

● Other functions : Anti-bolus system (ABS)

Automatic syringe size recognition Battery life indicator

User selectable drug names Programmable name or ward Infusion pressure monitoring

Infusion parameters protected by a password Priming

STAND-BY

Extended menu of user tests and service tests

● Event log : 2000 events

6 Infusion Pump 2 unit

Specifications :

- Pumping system : Peristaltic finger

- Delivery rate : - Infusion sets : 15, 19 or 20 drops/mL 3 to 300mL/h(1mL/h steps)

1 to 75 drops/min. (1 drop/min.steps) - Infusion sets : 60 drops/mL

1 to 100mL/h (1mL/h steps)

1 to 100 drops/min.(1 drop/min. steps) - Accuracy

- "mL/h"control mode : +/-10% (Using water or Sodium Chloride Solution and the remommended infusion set)

- Drops/min. control mode : +/-2%(10 minutes after the start or infusion, and after solution drips more than 500 times) - Volume delivered : 0 to 9,999mL

- Delivery limit range : to , L L steps ,"…" Deli e li it f ee - Purge flow function : More than 300mL/h

- Alarm : AIR/OCCLUSION/EMPITY/ FLOW ERR./DOOR/

LOW BATTERY/ FREE FLOW/ BATTERY ERR./ DRIP SENSOR ERR.

- Occlusion detection pressure : 39.2 to 117.7kPa (0.4 to 1.2kgf/cm2) - Warning light or display and buzzer

come on and pump stops except during "LOW BATTERY" alarm.

- Infusion complete function : When the total volume delivered reaches the preset delivery limit, light and buzzer sound notifies the operator

- Alarm terminal : Outputs an alarm relay contact (can be connected to nurse-call) Contact rating : DC 24V, 0.5A - Special functions : - KEEP VEIN OPEN (KVO) function

(6)

rate of 3mL/h after delivery limit (preset volume) has been reached. (When the drip volume is set to 60 drops/mL, KVO rate is 1 mL/h

- Tubing clamp function

Tubing clamp squeezes infusion tubing shut when pump door is opened

- Volume delivered clear function

Holdi g do the Σ L CLEAR s it h fo a out 0.5 seconds clears the volume delivered reading. - Special functions : - Volume memory function

In the "Memory mode", the previous delivery rate and delivery limit will be indicated on the display when the power is turned on. (The mode can be changed by using the internal mode select switch.) - Repeat alarm function

The repeat alarm function buzzer sounds again if no corrective action is taken within two minutes after the buzzer was switched off in the standard mode. (The mode can be changed by using the internal mode select switch.)

- Start reminder alarm function

The buzzer sounds when the pump is ready to deliver the solution but remains out of operation for two minutes in the standard mode. (the mode can be changed by using the internal mode select switch.) - Operating conditions : +10 to +40°C, 30 to 85% RH(no condensation)

- Storage conditions : -20 to +45°C, 10 to 95% RH (non condensation) - Power supply : - AC 100 to 240V, 50/60Hz

- Internal Nickel-Cadmium battery can run the pump continuously for about 2 hours. (if the battery is new and the pump operates at the delivery rate of 25mL/h after 12 hour's charging with the power off). - Power consumption : Less than 16VA

- Classification : Class I ? Internal power cupply/ type CF/IPX1 - Dimensions : 130(W) x 180(H) x 136(D) mm

- Weight : Approx. 2.3kg

- Accessories : AC Power cord : 1 Drip sensor : 1 Time lag fuses : 2 Instruction manual : 1

7 Sectio Set+Bak instrumen 40cmx30cm(2)+Tromol Ø30cm(2) 1 unit

Consist of :

- SCALPEL HANDLE #3 1

- SURGICAL SCISSORS DEL STR S/B 145 MM 1

- MAYO SCISSORS STR 170 MM 1

- MAYO SCISSORS RND BLD CVD 200 MM 1

- UMBILICAL CORD SCISSORS LAT-CVD 135 MM 1

- STANDARD FORCEPS SERR 180 MM 1

- STANDARD TISSUE FORCEPS 1X2 180 MM 1

- FOERSTER SPONGE FCPS SERR STR 242 MM 1

- BACKHAUS TOWEL CLAMP 110 MM 1

- PEAN FORCEPS STR 140 MM 1

- ROCHESTER -PEAN FORCEPS CVD 185 MM 1

- KOCHER FORCEPS STR 1X2 150 MM 1

- KOCHER-OCHSNER FORCEPS STR 1X2260 MM 1

- MIKULICZ PERITONEUM FORCEPS CVD 180 MM 1

- BAUMGARTNER NEEDLE HOLDER SERR 145 MM 1

- MAYO-HEGAR NEEDLE HOLDER 185 MM 1

- ROUX RETRACTOR 3/SET 165 MM 1

(7)

- RICHARDSON -EASTMEN BT 471RBT 472R 1

- KELLY RETRACTOR OPEN 70 X 65 MM 261 MM 1

- DOYEN ABDOMINAL RETRACTOR 53X80 MM 254 MM 1

- BALFOUR ABDOMINAL RETRACTOR 200X265 MM 1

- DOYEN RETRACTOR 60X60 MM 242 MM 1

- SIMPSON-BRAUN OBSTETRICAL FORCEPS 305 MM 1

- BUCHWALD TONGUE DEPRESSOR 19/23 MM 180 MM 1

- YANKAUER SUCT TUBE W/BORNG 4.8 MM 285 MM 1

- Bak instrumen 40cmx30cm 2

- Tromol Ø30cm 2

8 Vital Sign Monitor + Breaket 2 unit

Specifications General

Monitor Performance Specifications

Indicators Categoriezed alarms (4 prioprity levels), Visual alarm handle lamp, Heart rate tone, Battery status, External power LED

Tabular Trends Memory storage : 120 hours

Interfaces DC input connector : 12 to 18VDC, 2.5A Defibrillator Sync. Output

Signal level : 0 to 5 V pulse Pulse width : 100 ± 10ms

LAN digital output for transferring data Nurse call system connection

DC output : 5VDC, 1A Max

Battery (standard) Internal battery : rechargeable Li-ion battery, Battery status indicator,

Operating time : 2 hours typically

Thermal printer (standard) Speed : 25, 50mm/sec, Paper width : 57mm Accessories|Languages

Standard Accessories 5-lead patient cable 1ea, NIBP extension tube 1ea, Adult NIBP reusable cuff 1ea,SpO2 sensor extension cable 1ea., Adult SpO2 reusable sensor 1ea,

DC Adpter 18 VDC 2.5A 1 ea., Thermal paper 2 rolls Language German,English,Franch,Spainsh,Italian, Russian, Czech,

Polish, Turkish, Romanian, Portuguese, Bulgarian Specifications Performance

ECG

Leads type 3-lead, 5-lead

Lead selection 3-lead : I,II,III, 5-lead : I,II,III,aVR,aVL,aVF,V ECG waveforms 3-lead : 1 channel, 5-lead : 3/7 channels

Heart rate range Adult : 30-300bpm, Neonate/Pediatric : 30-350bpm Heart rate accuracy ±1bpm or ±1%, whichever is greater

Sweep speed 6.25, 12.5, 25, 50mm/sec

Filter Diagnostic mode: 0.05Hz-120Hz,

Monitoring mode:0.5-40Hz, Surgical mode : 0.5-25Hz S-T segment detection range -2.0 to 2.0mV

Arrhytmia analysis ASYSTOLE,VTACH,VFIB,BEGIMINY,ACCVENT,COUPLET, IRREGULAR,PAUSE,PVC,RONT,TRIGEMINY,VBRADY, SHORTRUN

Pacemaker detection mode Indicator on waveform display(user selectable) Protection Againts electrosurgical interference and defibrillation Respiration

Method Thoracic impedance

Channel selection RA-LA or RA-LL

Measurement range 5-120 Breath per minute

Accuracy ±1 Breath per minute

Apnea alarm Yes

(8)

Saturation range 0 to 100%

Saturation accuracy 70 to 100% ± 2digits, 0 to 69% unspecified

Pulse rate range 0 to 254 bpm

Pulse rate accuracy ± 2bpm NIBP

Method Oscillometry with linear deflation Operation mode Manual/ Automatic/ Continous Measurement range Adult pressure : 20 to 260mmHg

Pediatric Pressure : 20 to 230mmHg Neonate pressure : 20 to 120mmHg

Accuracy Mean error : less than ±5mmHg

Standard deviation : less than 8mmHg Temperature

Measurement range 15 to 45°C(59 to 113°F)

Accuracy ± 1°C

Compatibility YSI Series 400 temperature probes

9 Neonatus Resucitasi 1 unit

Spesifikasi :

- Safe, Controlled and Precise Peak Inspiratory Pressure (PIP)

Safely inflate the baby's lungs and provide optimum oxygenation by delivering consistent PIP iwht each breath avoiding the risk associated with under or over inflation at uncontrolled pressures

- Consistent and Precise Positive End Expiratory Pressure (PEEP)

Maintains Functional Residual Capacity (FRC) by providing a consistent PEEP throughout the resuscitation process

- Easy to Use

- Flexibility in Operation

Can accept and deliver oxygen concentrations from 21% to 100% coming from flowmeter or a blender

- Accurate Pressure Delivery

The fast-acting manometer provides constant reassurance of mask seal and delivered PIP and PEEP

- Alternate temporary respiratory support

Consistent PEEP can be delivered to assist with breathing during transport or ventilator circuit change

Technical Data

- Manometer Range : -20 to 80 cm H2O (-2.0 to 7.8 kPa) - Maximum Pressure Relief : @ 8 LPM

- Peak Inspiratory Pressure (PIP) : @ 8 LPM - Positive-end expiratory : @ 8 LPM

pressure (PEEP)

- Gas Inlet flow range : 5 LPM(min)to 15LPM(max)if the gas inlet flow rate increase from 5 to 15 LPM, the peak inspiratory pressure typically increases ±8 cmH2O (0.8 kPa) - Delivered oxygen concentration : up to 100% depending on gas supply

- Operating time (400 L cylinder) : "@ 8 LPM - Operating and storage limits : - ˚C to ˚C

up to 90% relative humidity

10 Doppler 3 unit

Specifications :

- Shipping box dimensions : 115cmx62.5cmx19cm(45-3/8"x24-5/8"x7-1/2") - Basket : 30.5cmx20.3cmx8.9cm(12"Wx8"Dx3.5" H) - Fits on 1.25" (3 cm) diameter post

- Digital display with rechargeable batrries

(9)

Features :

- Bubble CPAP provides a lung protective, safe and effective method of respiratory support to spontaneously breathing neonates

- Bubble CPAP is safe, non invasive and lung protective - Effectively maintains functional Residual Capacity (FRC) - Helps edu e the i fa t’s Wo k of B eathi g WOB

- Bubble CPAP may reduce the need for intubations and mechanical ventilation - Bubble CPAP tends to reduce the incidence of Chronic Lung Disease (CLD) - Bubble CPAP may improve non-pulmonary outcomes

THE DELIVERY SYSTEM ~ BC161, Consist Of :

Humidification Chamber ◊ Easy to maintain

◊ Maintains constant CPAP

◊ Closed system ensures safety by minimizing the risk of contamination ◊ Automatic waterfeed mechanism

◊ Dual float mechanism to maintain a constant water level for optimal humidification

◊ Constant compressible volume and low compliance Spesifikasi Teknis :

Inlet Port : 22mm Male

Outlet Port : 22mm Male

Compressible Volume : 280ml

Compliance : 0.4ml/cm H2O

Max. Operating Pressure : 80cm H2O

Max. Peak Flow : 180L/min

Single Heated Breathing Circuit

◊ Provide even heat distribution across the tube reducing heat loss and condensate build up

◊ Delivers optimal humidity to neonate ◊ Reduced work of breathing

◊ Unique spiral heater wires

◊ Minimise mobile condesate and reduce circuit maintenance Spesifikasi Teknis :

Ci uit Le gth – E pi ato : 1.1m

Inspiratory : 1.2m

Compressible Volume

Inspiratory Limb : 149ml

Expiratory Limb : 101ml

Connectors : Manufactured to ISO 5356-1

Resistance Flow : 0.6cm H2O @ 6L/min

Pressure Manifold

◊ Ensures patient safety by limiting the pressure delivered in an event of an occlusion ◊ Allows connection to a pressure monitoring device or an air/oxygen analyzer

Spesifikasi Teknis :

Maximum Pressure Limit : 17cm H2O @ 8L/min

Inlet Connector : O2 inlet adapter

Outlet Connector : 22mm Female or 15mm Female

Luer Port : Female Luer

Oxygen analyzer port : 22mm Female or 15mm Female

CPAP Generator

◊ CPAP probe allows to ease of pressure setting from 3 to 10cm H2O

◊ Auto-level mechanism ensures constant mean CPAP pressure

◊ Detachable overflow container allows continuous CPAP while removing excess water from condensate

Spesifikasi Teknis :

Inlet Port 15mm Female

Exit Port 22mm Male

(10)

Bubbler water container volume Approx. 500mls THE PATIENT INTERFACE

Nasal Tubing 70mm

◊ Low Resistance to flow resulting in low Work of Breathing (WOB) ◊ Supports various caring positions like prone, supine, lateral, etc ▪ Nasal Prong

◊ Soft, plia le, a d ge tle o the a ’s a es ◊ Anatomically curved for a comfortable fit

◊ 9 sizes based on prong diameter and width of septum ▪ Infant Bonnet

◊ Hold the nasal tubing in place for ease to setup

◊ Can open bonnet top to allow clinical procedures like ultrasound ▪ Head Gear

◊ An Alternative to the infant bonnet, the headgear is designed to suit larger infants of up 45cm head circumference

◊ With 3-point fixation for a stable setup ◊ Soft, elastic material adapts to head contour HUMIDIFIER BASE

◊ Used to warm and humidity gases delivered to patients requiring mechanical ventilation, positive pressure breathing assistance,or other mechanical gases ◊ Temperature display and humidity alarm

◊ Simple controls and easy to read display

◊ Uses advanced algorithms to optimise humidification delivery and avoid nuisance alarms

◊ One button selects optimal temperature and humidification levels for neonatal, paediatric and adult patients requiring invasive or noninvasive respiratory

support

◊ Clinically based alarm system

◊ Continuous digital display of saturated gas temperature combined with and intuitive set-up indicator simple controls

◊ Automatic standby during periods of gas flow interruption ow water out monitoring Spesifikasi Teknis :

* Heater Plate Over-temperature Cutout Temperature Control Setting

* Invasive Mode : Chamber outlet : 35.5 - 42°C, Airways 35 - 40°C * Non-Invasive Mode : Chamber outlet : 31 - 36°C, Airways 28 - 34°C * Display : Three Digit 14mm 7 segment LED

* Range : 10-70°C

Accuracy : ± 0.3°C (in 25-45°C temperature range) Alarm Parameter

* High Humidity Alarm * Low Humidity Alarm * Sound Pressure Level SCOPE OF DELIVERY :

● 1x Humidifier base ● 5x Infant Delivery system

Terdiri dari :

- 5xHumidification Chamber - 5xPressure manifod

- 5xSingle heated breathing circuit - 5xCPAP Generator

(11)

● 20x Nasal prong ● 1x Heater wire adaptor ● 1x Temperature probe ● 2x C-Clamp

● 1x Air-O2 Mixer

● 1x Flowmeter oxygen 15lpm

● 1x Gas Supply Line @2.1m for air and O2 ● 1x Oxygen tube, Length 1,8m

● 1x Air Entrainer ● 2x Nipple Nut ● 1x Tiang Infus Medical Air Compressor

● For delivery of dry medical grade quality compressed air ● Air quality acc to ED DIN 12021

● Indication of high temperature inside the compressor's box

● Integrated water separator keeps the dew point below ambient temperature ● Oil free compressors with temperature protection

● Automatic pressure switching of the compressor to a small air tank ● Output air pressure set by filter regulator and indicated by manometer Spesifikasi Teknis :

● Nominal voltage frequency :

● Nominal current :

● Output pressure :

● Output capacity at pressure 3.5 bar :

● Filtration :

● Dew point depresion :

● Sound level :

ALAT KESEHATAN IGD RS RUANGAN TINDAKAN

1 Nebulizer Sederhana 5 unit

Specifications :

● Electrical 230V, 50 Hz/ : 230 V, 60 H

● Power Consumption 1.38 VA

● Nebulizer Rate 0.4 ml/min (without cap)

● Particle size *MMD apriximately 5µm

(basedon EN13544-1) ● Medication Cup Capacity 7 ml (cc) max

● Appropriate Medication Quantities 2-7 ml (cc)

● Operating Temperature/Humidity +10oC to 40oC, 30% to 85% RH ● Storage Temperature/Humidity +20oC to 60oC, 10% to 95% RH

● Contents

-2 Emergency stretcher (handle kanan, kiri, stand infus, rank oksigen) 2 unit Specifications :

● Dimensi : 200x65x80cm

● Konstruksi : Pipa S/S, Pipa SS, As MS ● Side Rail : Stainless

● Finishing : Polishing

● Accessories : Matras Lapis Vinyl Tiang Infus

Tempat Tabung Oksigen Keranjang

(12)

3 Kit Pemeriksaan Sederhana 3 set

4 Examination Lamp 1 unit

Specifications :

» Light intensity : Adjustable in two levels:

40.000 Lux/0.5m ±5% without filter 20.000 Lux/0.5m ±5% with filter

» Stand height : 105 cm

● Opthal os ope

I otoscope head, II May ophthalmoscope head, nasal speculum expandable, bent arm illuminator,2 laryngeal mirrors No. 3 and 4, tongue blade holder, replacement lamp otoscope (also for bent arm illuminator)

• Ch o e-plated ith eedle a d ush,

● To gue Spatula

• Made of Metal soft non-chill rims for improved adaptation on the skin.

• Bell, Ø .

• supplied ith a pai of epla e e t ea -tips a d a epla e e t e a e.

● Stetoskop Pediat i

stethoscope with precision double chest-piece. The acoustic performance has been considerably improved.

lightweight aluminium, galvanized.

• Spe ial e a e fo pe fe t aus ultatio , Ø , ith pa ti ula l flat a d soft non-chill rims for improved adaptation on the skin.

• Bell, Ø .

(13)

» Mounting type : Pentagonal base w/5 wheels

» Articulated arm : Reach 900 mm

» Lamp head : 1 each, rotates 330°

» Lamp head diameter : 100 mm

» Bulb : Halogen 12V, 50W

» Bulb operation life : 1500h

» Color temperature : 3200 Kelvin without filter 4000 Kelvin with filter

» Color rending index : 100

» Focus diameter : 130 mm/m

» Power/generator input : 230V, 50Hz

» Temperature in the field : Between +3° and +5°C

5 Vital Sign Monitor+Breaket 2 unit

Specifications General

Monitor Performance Specifications

Indicators Categoriezed alarms (4 prioprity levels), Visual alarm handle lamp, Heart rate tone, Battery status, External power LED

Tabular Trends Memory storage : 120 hours

Interfaces DC input connector : 12 to 18VDC, 2.5A Defibrillator Sync. Output

Signal level : 0 to 5 V pulse Pulse width : 100 ± 10ms

LAN digital output for transferring data Nurse call system connection

DC output : 5VDC, 1A Max

Battery (standard) Internal battery : rechargeable Li-ion battery, Battery status indicator,

Operating time : 2 hours typically

Thermal printer (standard) Speed : 25, 50mm/sec, Paper width : 57mm Accessories|Languages

Standard Accessories 5-lead patient cable 1ea, NIBP extension tube 1ea, Adult NIBP reusable cuff 1ea,SpO2 sensor extension cable 1ea., Adult SpO2 reusable sensor 1ea,

DC Adpter 18 VDC 2.5A 1 ea., Thermal paper 2 rolls Language German,English,Franch,Spainsh,Italian, Russian, Czech,

Polish, Turkish, Romanian, Portuguese, Bulgarian Specifications Performance

ECG

Leads type 3-lead, 5-lead

Lead selection 3-lead : I,II,III, 5-lead : I,II,III,aVR,aVL,aVF,V ECG waveforms 3-lead : 1 channel, 5-lead : 3/7 channels

Heart rate range Adult : 30-300bpm, Neonate/Pediatric : 30-350bpm Heart rate accuracy ±1bpm or ±1%, whichever is greater

Sweep speed 6.25, 12.5, 25, 50mm/sec

Filter Diagnostic mode: 0.05Hz-120Hz,

Monitoring mode:0.5-40Hz, Surgical mode : 0.5-25Hz S-T segment detection range -2.0 to 2.0mV

Arrhytmia analysis ASYSTOLE,VTACH,VFIB,BEGIMINY,ACCVENT,COUPLET, IRREGULAR,PAUSE,PVC,RONT,TRIGEMINY,VBRADY, SHORTRUN

Pacemaker detection mode Indicator on waveform display(user selectable) Protection Againts electrosurgical interference and defibrillation Respiration

Method Thoracic impedance

Channel selection RA-LA or RA-LL

Measurement range 5-120 Breath per minute

Accuracy ±1 Breath per minute

(14)

SpO2

Saturation range 0 to 100%

Saturation accuracy 70 to 100% ± 2digits, 0 to 69% unspecified

Pulse rate range 0 to 254 bpm

Pulse rate accuracy ± 2bpm NIBP

Method Oscillometry with linear deflation Operation mode Manual/ Automatic/ Continous Measurement range Adult pressure : 20 to 260mmHg

Pediatric Pressure : 20 to 230mmHg Neonate pressure : 20 to 120mmHg

Accuracy Mean error : less than ±5mmHg

Standard deviation : less than 8mmHg Temperature

Measurement range 15 to 45°C(59 to 113°F)

Accuracy ± 1°C

Compatibility YSI Series 400 temperature probes

6 Curetage set+Bak instrument 40cm x 30cm(2) + Tromol Ø30cm(2) 2 set

Consist of :

- MAYO SCISSORS CVD 155 MM 1

- SIMS VAG SPECULUM 70X26 MM/75X30MM 127 MM 1

- KRISTELLER VAG SPEC SET 75X30MM 178 MM 1

- SIMS UTERINE PROBE GRAD CVD D:4/330 MM 1

- BOZEMANN FORCEPS S-CVD SERR 250 MM 1

- BRAUN TENACULUM FRCPS DEL STR 1X250 MM 1

- RECAMIER UTER. CURRETTE SH/RIG #4 14.0 MM 1

- RECAMIER UTER. CURRETTE SH/RIG #8 19.5 MM 1

- WINTER PLACENTA/OVUM FCPS #2 CVD 292 MM 1

- Bak instrumen 40cmx30cm 2

- Tromol Ø30cm 2

7 Sterilisator/Auto lave esar Uk.8 LtrΘ3 m 1 unit

Specifications :

■ Effective : 9 8 . 8 L ( 8 5 L )

■ Chamber size : φ× D

■ Outer dimensions : 667(W) × 1011(H) × 652 (D)mm ■ Max.Steril.temp : 135

■ Process mode : 3 mode

■ Net weight : 78kg

8 Meja Gynecology 1 unit

Technical Details

● Height Adjustment : 600 - 900 mm

● Tabletop : 550 x 1270 mm

● Table Base : 575 x 1050 mm

● Head Section : 550 x 1320 mm ● Backrest Section : 550 x 600 mm ● Seat Section : 550 x 385 mm ● Length of Seat Section w/ : 550 x 550 mm

Seat Extension Pad

● Voltage : 230V, 50Hz

Positions

● Backrest Section : 52°upward from horizontal position ● Seat Section : In combination with backrest section,

19° Trendelenburg and 5° reverse

Trendeleburg(Providing 550mm Mounting height) ● Foot Support : Integrated with handles, can be swiveled to the

(15)

● Knee Cruthes : Integrated with handles, can be swiveled to the sides, and moved up and down

Standard Accessories

● Foot Support (2ea) or Knee Cruthes (2ea) ● Waste Tray

● Examination Tissue Paper

9 Partus Set + Bak Instrument 40cmx30cm(2) + TromolØ30cm(2) 2 set

Consist of :

- SURGICAL SCISSORS STR S/B145MM 1

- LISTER BANDAGE SCISSORS HVY 180MM 1

- STANDARD FORCEPS SERR 145MM 1

- STANDARD TISSUE FORCEPS 1X2 145MM 1

- FOERSTER SPONGE FCPS SERR STR 242MM 1

- HARTMANN MOSQUITO FCSDEL STR 100MM 1

- CRILE FORCEPS STR 160MM 1

- MAYO-HEGAR NEEDLE HOLDER150MM 1

- GRAVE VAGINAL SPECULUM 75X20MM 1

- SIMS VAG.SPECULUM75X30MM/80X35MM153MM 1

- BOZEMANN-DOUGLAS FCPSS-CVDSERR260MM 1

- BRAUN-STADLER EPISIOTOMY SCISSORS145MM 1

- UMBILICAL CORD SCISSORS105MM 1

- BASKET WIDE PERFORATION 243X253X56MM 1

- Bak instrumen 40cmx30cm 2

- Tromol Ø30cm 2

10 Sectio Set+Bak Instrument 40cmx30cm(2) + TromolØ30cm(2) 1 set

Consist of :

- SCALPEL HANDLE #3 1

- SURGICAL SCISSORS DEL STR S/B 145 MM 1

- MAYO SCISSORS STR 170 MM 1

- MAYO SCISSORS RND BLD CVD 200 MM 1

- UMBILICAL CORD SCISSORS LAT-CVD 135 MM 1

- STANDARD FORCEPS SERR 180 MM 1

- STANDARD TISSUE FORCEPS 1X2 180 MM 1

- FOERSTER SPONGE FCPS SERR STR 242 MM 1

- BACKHAUS TOWEL CLAMP 110 MM 1

- PEAN FORCEPS STR 140 MM 1

- ROCHESTER -PEAN FORCEPS CVD 185 MM 1

- KOCHER FORCEPS STR 1X2 150 MM 1

- KOCHER-OCHSNER FORCEPS STR 1X2260 MM 1

- MIKULICZ PERITONEUM FORCEPS CVD 180 MM 1

- BAUMGARTNER NEEDLE HOLDER SERR 145 MM 1

- MAYO-HEGAR NEEDLE HOLDER 185 MM 1

- ROUX RETRACTOR 3/SET 165 MM 1

- VOLKMANN RETR4- PRGBLUNT 8X19 MM 222 MM 1

- RICHARDSON -EASTMEN BT 471RBT 472R 1

- KELLY RETRACTOR OPEN 70 X 65 MM 261 MM 1

- DOYEN ABDOMINAL RETRACTOR 53X80 MM 254 MM 1

- BALFOUR ABDOMINAL RETRACTOR 200X265 MM 1

- DOYEN RETRACTOR 60X60 MM 242 MM 1

- SIMPSON-BRAUN OBSTETRICAL FORCEPS 305 MM 1

- BUCHWALD TONGUE DEPRESSOR 19/23 MM 180 MM 1

- YANKAUER SUCT TUBE W/BORNG 4.8 MM 285 MM 1

- Bak instrumen 40cmx30cm 2

Referensi

Dokumen terkait

Pada penelitian ini menggunakan instrumen kuisioner tingkat pengetahuan pasien dalam meminum obat yang terdiri dari 12 pertanyaan yaitu pengetahuan pasien dalam hal

daerah tanah lanau, pengujian ini dilakukan dengan stabilisasi material kapur?. dengan penambahan semen agar dapat diketahui seberapa besar campuran

Pembaharuan tersebut dapat dilakukan dengan melihat peraturan yang dirasa mendekati dengan perbuatan spamming yaitu Pasal 28 ayat (1) Undang-Undang Nomor 11 Tahun

Upaya peningkatan mutu pelayanan kesehatan dapat diartikan keseluruhan upaya dan kegiatan secara komprehensif dan integratif memantau dan menilai mutu pelayanan RS Royal

Mengidentifikasi rencana pembangunan Pabrik Industri yang diperkirakan dapat menimbulkan dampak terhadap lingkungan baik secara langsung atau tidak langsung serta memperkirakan

Mengenai kejahatan yang melibatkan seorang difabel sebagai korbanya dalam tindak pidana perkosaan dalam perkara Nomor 33/Pid.B/2013/PN.Kdl Menjatuhkan pidana penjara

Kepada seluruh staf pengajar dan civitas akademika Program Magister Ilmu Kimia Fakultas Matematika Dan Ilmu Pengetahuan Alam Universitas Sumatera Utara yang telah banyak

Tujuan penelitian ini adalah untuk mengetahui jensi-jenis hama yang menyerang tanaman nilam di daerah Sukabumi (khususnya di daerah Sukamulya dan juga mengetahui