ANALISIS KEKUATAN ABUTMENT
ANALISIS KEKUATAN ABUTMENT
JEMBATAN SRANDAKAN KULON PROGO D.I. YOGYAKARTA JEMBATAN SRANDAKAN KULON PROGO D.I. YOGYAKARTA[C]2008:MNI-EC [C]2008:MNI-EC
1. BREAST WALL
1. BREAST WALL
1.1. PEMBESIAN BREAST WALL 1.1. PEMBESIAN BREAST WALL
Mutu
Mutu Beton Beton : : K K -- 300300 Kuat tekan beton,
Kuat tekan beton,
f f
cc' =
' =
2244..99 MMPPaa MMuuttu u BBaajja a :: U U -- 3939 Tegangan leleh baja,
Tegangan leleh baja,
f f
yy=
=
339900 MMPPaa Dimensi Breast Wall,Dimensi Breast Wall,
B
B
yy=
=
2200..0000 mmbb
77=
=
11..0000 mm Ditinjau Breast Wall selebar 1 m :Ditinjau Breast Wall selebar 1 m : Lebar Breast Wall,
Lebar Breast Wall,
b =
b =
11000000 mmmm Tebal Breast Wall,Tebal Breast Wall,
h =
h =
11000000 mmmm Luas penampang breast wall yang ditinjau,Luas penampang breast wall yang ditinjau,
A
A
gg= b * h =
= b * h =
10000001000000 mmmm22P
P
uu=
=
gaya aksial ultimit pada breast wall (kN)gaya aksial ultimit pada breast wall (kN)M
M
uu=
=
momen ultimit pada breast wall (kNm)momen ultimit pada breast wall (kNm)φφ.P
.P
nn= P
= P
uuα = φ
α = φ.P
.P
nn/ (f
/ (f
cc'.A
'.A
gg) =
) = P
P
uu*10
*10
44/ (f
/ (f
cc' * A
' * A
gg))
φφ.M
.M
nn= M
= M
uuβ = φ
β = φ.M
.M
nn/ (f
/ (f
cc'.A
'.A
gg..hh)
) =
= M
M
uu*10
*10
77/ (f
/ (f
cc' * A
' * A
gg* h)
* h)
HAS
HASIL IL ANAANALISLISIS IS BEBBEBAN AN UNTUUNTUK K LEBLEBAR AR 1 1 MM N
Noo KKOOMMBBIINNAASSII
P
P
uuM
M
uuP
P
uuM
M
uu α α ββ BBEEBBAAN N UULLTTIIMMIITT ((kkNN)) ((kkNN--mm)) ((kkNN)) ((kkNN--mm))
11 KKOOMMBBIINNAASSI I - - 11 1166117722..88 1122008811..2299 880088..6644 660044..0066 00..003322 00..00224433 22 KKOOMMBBIINNAASSI I - - 22 1166552266..44 1166111144..2200 882266..3322 880055..7711 00..003333 00..00332244 33 KKOOMMBBIINNAASSI I - - 33 1166117722..88 1155998833..7700 880088..6644 779999..1188 00..003322 00..00332211 44 KKOOMMBBIINNAASSI I - - 44 1166557744..88 1122008811..2299 882288..7744 660044..0066 00..003333 00..00224433 55 KKOOMMBBIINNAASSI I - - 55 1144226644..44 2288334433..1177 771133..2222 11441177..1166 00..002299 00..00556699 Jarak tulangan terhadap sisi luar beton,
Jarak tulangan terhadap sisi luar beton,
d' =
d' =
100100 mmmmh' = h - 2*d' =
h' = h - 2*d' =
880000 mmmmh' / h =
h' / h =
0.80.8 NilaiNilai α = φα = φ.P.Pnn/ (f / (f cc'.A'.Agg) dan) dan β = φβ = φ.M.Mnn/ ( f / ( f cc'.A'.Agg.h ) diplot ke dalam diagram interaksi diperoleh,.h ) diplot ke dalam diagram interaksi diperoleh, Rasio tulangan yang diperlukan,
Luas tulangan yang diperlukan :
A
s=
ρ
* b * h =
10000 mm2 Diameter tulangan yang digunakan, D = 25 mmTulangan tekan dibuat sama dengan tulangan tarik :
A
s (tekan)= A
s (tarik)= 1/2* A
s=
5000 mm2Jarak tulangan yang diperlukan,
s =
π
/4*D
2*b /(1/2*A
s) =
98 mm Digunakan : Juml.Lapis dia. Tulangan JarakTulangan tekan, 2 D 25 - 150
ρ
tekan=
0.654%Tulangan tarik, 2 D 25 - 150
ρ
tarik=
0.654%Rasio tulangan yang digunakan,
ρ
=
1.309%Plot nilai φ.Pn/ (f c'.Ag) dan φ.Mn/ ( f c'.Ag.h ) ke dalam diagram interaksi
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.30 0.32 0.34 0.36 0.38 0.40 φφφφ.Mn / (fc'.Ag.h) φ φφ φ . P n / ( f c ' . A g ) e/h=2.00 e/h=1.00 e/h=0.30 e/h=0.20 e/h=0.15 e/h=0.10 e/h=0.05 e/h=0.01 ρ= 1% ρ= 2% ρ= 3% ρ= 4% ρ= 5% e/h=0.5 φ= 0.80 φ =
1.2. ANALISIS BREAST WALL DENGAN DIAGRAM INTERAKSI
Untuk mengontrol apakah tulangan Breast Wall yg ditetapkan dengan Diagram Interaksi (tak berdimensi) untuk Uniaxial Bending tersebut telah mencukupi, perlu dilakukan analisis kekuatan Breast Wall dengan Diagram Interaksi P-M untuk berbagai macam kombinasi pembebanan. Input data, persamaan yang digunakan untuk analisis, dan hasil analisis Breast Wall disajikan sebagai berikut.
ANALISIS DINDING BETON BERTULANG DENGAN DIAGRAM INTERAKSI
DATA DINDING BETON BERTULANG
Mutu Beton, K - 300
Mutu Baja Tulangan, U - 39
Kuat tekan beton,
f
c' =
24.9 MPa Tegangan leleh baja,f
y=
390 MPa Modulus elastik baja,E
s=
2.E+05 MPa Faktor distribusi teg.β
1=
0.85Ditinjau dinding selebar,
b =
1000 mmTebal dinding
h =
1000 mmJarak tul. thd.tepi beton
d' =
100 mm Baja tulangan tarik ( As) :2 lapis D 25 jarak 150 Baja tulangan tekan ( As' ) :
2 lapis D 25 jarak 150
Luas tulangan tarik,
A
s=
6545 mm2 Luas tulangan tekan,A
s' =
6545 mm2 Rasio tulangan tarik,ρ
s=
0.654%Rasio tulangan tekan,
ρ
s' =
0.654% Faktor reduksi kekuatan, Ф = 0.65PERSAMAAN YANG DIGUNAKAN UNTUK PERHITUNGAN DIAGRAM INTERAKSI
Tinggi efektif,
d = h - d'
Pada kondisi tekan aksial sentris :P
no= 0.80*[ 0.85* f
c' * b * h + ( A
s+ A
s' )*( f
y- 0.85*f
c' )] * 10
-3 kN Gaya tekan aksial nominal,P
n harus ≤P
noh b d d'
φ
.Pn
φ
.Mn
A s A s 'Cs
Cc Cs'
Pada kondisi balance :
c
b= 600 / (600 + fy) * d
a
b= β
1* c
bε'
s= 0.003 * (c
b- d') / c
b Untuk,ε'
s≥ f
y/ E
s makaf
s' = f
y Untuk,ε'
s< f
y/ E
s makaf
s' = ε'
s* E
s Gaya-gaya internal beton dan baja :C
c= 0.85 * f
c' * b * a
b* 10
-3 kNC
s= A
s* f
y* 10
-3 kNC
s' = A
s' * ( f
s' - 0.85*f
c' ) * 10
-3 kN Gaya aksial tekan nominal kondisi balance :P
nb= C
c+ C
s' - C
s kN harus ≤P
noMomen nominal kondisi balance :
M
nb= [ C
c* (h/2 - a
b/2) + C
s* (d - h/2) + C
s' * (h/2 - d') ] *10
-3 kN-m Pada kondisi garis netral terletak pada jarak c dari sisi beton tekan terluar :ε
s= 0.003 * ( c - d ) / c
ε'
s= 0.003 * ( c - d' ) / c
Untuk[ ε
s] ≥ f
y/ E
s makaf
s= [ε
s] / ε
s* f
y Untuk[ ε
s] < f
y/ E
s makaf
s= ε
s* E
s Untukε'
s≥ f
y/ E
s makaf
s' = f
y Untukε'
s< f
y/ E
s makaf
s' = ε'
s* E
sa = β
1* c
Gaya-gaya internal beton dan baja :
C
c= 0.85 * f
c' * b * a * 10
-3 kNC
s= A
s* f
s* 10
-3 kNC
s' = A
s' * ( f
s' - 0.85*f
c' ) * 10
-3 kN Gaya aksial tekan nominal :P
n= C
c+ C
s' - C
s kN harus ≤P
noMomen nominal :
M
n= [ C
c* (h/2 - a/2) - C
s* (d - h/2) + C
s' * (h/2 - d') ] *10
-3 kN-m Faktor reduksi kekuatan :Ф = 0.65 untuk Pn≥ 0.10*f c' * b*h
Diagram Interaksi P-M 0 2000 4000 6000 8000 10000 12000 14000 0 500 1000 1500 2000 2500 3000 3500 φφφφ.Mn(kN-m) φ φφ φ . P n ( k N )
1.3. TULANGAN GESER BREAST WALL
Perhitungan tulangan geser untuk Breast Wall didasarkan atas momen dan gaya aksial ultimit untuk kombinasi beban yang menentukan dalam perhitungan tulangan aksial tekan dan lentur.
Gaya aksial ultimit rencana,
P
u=
713.22 kNMomen ultimit rencana,
M
u=
1417.16 kNmMutu Beton : K - 300
f
c' =
24.9 MPaMutu Baja : U - 39
f
y=
390 MPaDitinjau dinding abutment selebar,
b =
1000 mmGaya aksial ultimit rencana,
P
u=
713220 NMomen ultimit rencana,
M
u=
1.42E+09 NmmFaktor reduksi kekuatan geser,
φ
=
0.6Tinggi dinding abutment,
L =
4000 mmTebal dinding abutment,
h =
1000 mmLuas tulangan longitudinal abutment,
A
s=
13090 mm2Jarak tulangan thd. Sisi luar beton,
d' =
100 mV
u= M
u/ L =
354290 Nd = h -d' =
900.00 mmV
cmax= 0.2 * fc' * b * d =
4482000 Nφ
* V
cmax=
2689200 N > Vu (OK)β
1= 1.4 - d / 2000 =
0.95 < 1 maka diambilβ
2= 1 + Pu / (14 * fc' * b * h) =
1.002β
1=
0.95β
3=
1V
uc=
β
1*
β
2*
β
3* b * d * √ [ A
s* f
c' / (b * d) ] =
515586 NV
c= V
uc+ 0.6 * b * d =
1055586 Nφ
* V
c=
633352 Nφ* Vc > Vu (hanya perlu tul. Geser min.) Geser pada beton sepenuhnya dipikul oleh tulangan geser, sehingga :
V
s= V
u/
φ
=
590483 N Untuk tulangan geser digunakan besi beton :D 16 Jarak arah y, Sy= 350 mm
Luas tulangan geser,
A
sv=
π
/4*D
2*(b / S
x) =
574.46 mm2 Jarak tul.geser yang diperlukan,S
x= A
sv* fy * d / V
s=
341 mmDigunakan tulangan geser : D 16 Jarak arah x, Sx = 300 mm
2. BACK WALL
2.1. BACK WALL BAWAH
Dimensi : Tebal,
h = b
2=
0.55 m Lebar,B
y=
20.00 m Momen ultimit,M
u=
2862.69 kNm Gaya geser ultimit,V
u=
2294.55 kN Ditinjau selebar 1 m, maka :M
u=
143.1344 kNmV
u=
114.7275 kN2.1.1. TULANGAN LENTUR
Momen rencana ultimit,
M
u=
143.13 kNm Mutu beton, K - 300 Kuat tekan beton,f
c' =
24.90 MPa Mutu baja, U - 39 Tegangan leleh baja,f
y=
390 MPaTebal beton,
h =
550 mmJarak tulangan terhadap sisi luar beton,
d' =
50 mm Modulus elastis baja,E
s=
2.0E+05 Faktor bentuk distribusi tegangan beton,β
1=
0.85ρ
b=
β
1* 0.85 * f
c’/ f
y* 600 / ( 600 + f
y) =
0.02796R
max= 0.75 *
ρ
b* f
y*[1 – ½*0.75*
ρ
b* f
y/ ( 0.85 * f
c’ )] =
6.59766 Faktor reduksi kekuatan lentur,φ
=
0.80 Faktor reduksi kekuatan geser,φ
=
0.60Tebal efektif,
d = h - d' =
500 mmLebar yang ditinjau,
b =
1000 mmMomen nominal rencana,
M
n= M
u/
φ
=
178.92 kNm Faktor tahanan momen,R
n= M
n* 10
-/ ( b * d ) =
0.71567Rn < Rmax (OK) Rasio tulangan yang diperlukan :
ρ
= 0.85 * f
c’ / f
y* [ 1 -
√
* [1 – 2 * R
n/ ( 0.85 * f
c’ ) ]
=
0.00187 Rasio tulangan minimum,ρ
min= 0.25%*1.4 / f
y=
0.00090 Rasio tulangan yang digunakan,ρ
=
0.00187Luas tulangan yang diperlukan,
A
s=
ρ ∗
b * d =
934 mm2 Diameter tulangan yang digunakan,D
16 mmJarak tulangan yang diperlukan,
s =
π
/ 4 * D
2* b / A
s=
215.365 mm Digunakan tulangan,D 16
-
200
A
s=
π
/ 4 * D
2* b / s =
1005 mm2 Untuk tulangan bagi diambil 50% tulangan pokok.A
s' = 50% * A
s=
467 mm2 Diameter tulangan yang digunakan,D
13 mmJarak tulangan yang diperlukan,
s' =
π
/ 4 * D
2* b / A
s' =
284.348 mm Digunakan tulangan,D 13
-
200
A
s' =
π
/ 4 * D
2* b / s' =
664 mm22.1.2. TULANGAN GESER
Gaya geser ultimit,
V
u=
114727 NV
c= 1/6*(√ f
c') * b * d =
415832 Nφ
.V
c=
249499 N > 2 * Vu Tdk. Perlu tul.geserφ
.V
s= V
u-
φ
.V
c=
--- NV
s=
--- NDiameter tul. yang digunakan, D --- Ambil jarak arah Y --- mm Luas tulangan geser, Av =π / 4 * D2* b / Sy= --- mm2 Jarak tulangan geser yang diperlukan ( arah X ) :
Sx= Av* f y* d / Vs= --- mm
Digunakan tulangan, D --- Jarak arah X --- mm Jarak arah Y --- mm
2.2. BACK WALL ATAS
Dimensi : Tebal,
h = b
1=
0.35 m Lebar,B
y=
20.00 m Momen ultimit,M
u=
856.33 kNm Gaya geser ultimit,V
u=
1299.636 kN Ditinjau selebar 1 m, maka :M
u=
42.81666 kNm2.2.1. TULANGAN LENTUR
Momen rencana ultimit,
M
u=
42.82 kNmMutu beton, K - 300 Kuat tekan beton,
f
c' =
24.90 MPaMutu baja, U - 39 Tegangan leleh baja,
f
y=
390 MPaTebal beton,
h =
350 mmJarak tulangan terhadap sisi luar beton,
d' =
50 mmModulus elastis baja,
E
s=
2.0E+05Faktor bentuk distribusi tegangan beton,
β
1=
0.85ρ
b=
β
1* 0.85 * f
c’/ f
y* 600 / ( 600 + f
y) =
0.02796R
max= 0.75 *
ρ
b* f
y*[1 – ½*0.75*
ρ
b* f
y/ ( 0.85 * f
c’ )] =
6.59766Faktor reduksi kekuatan lentur,
φ
=
0.80Faktor reduksi kekuatan geser,
φ
=
0.60Tebal efektif,
d = h - d' =
300 mmLebar yang ditinjau,
b =
1000 mmMomen nominal rencana,
M
n= M
u/
φ
=
53.52 kNmFaktor tahanan momen,
R
n= M
n* 10
-6/ ( b * d
2) =
0.59468Rn < Rmax (OK) Rasio tulangan yang diperlukan :
ρ
= 0.85 * f
c’ / f
y* [ 1 -
√
* [1 – 2 * R
n/ ( 0.85 * f
c’ ) ]
=
0.00155Rasio tulangan minimum,
ρ
min= 0.25%*1.4 / f
y=
0.00090Rasio tulangan yang digunakan,
ρ
=
0.00155Luas tulangan yang diperlukan,
A
s=
ρ ∗
b * d =
464 mm2Diameter tulangan yang digunakan,
D
13 mmJarak tulangan yang diperlukan,
s =
π
/ 4 * D
2* b / A
s=
286.026 mmDigunakan tulangan,
D 13
-
200
A
s=
π
/ 4 * D
2* b / s =
664 mm2 Untuk tulangan bagi diambil 50% tulangan pokok.A
s' = 50% * A
s=
232 mm2Diameter tulangan yang digunakan,
D
13 mmJarak tulangan yang diperlukan,
s' =
π
/ 4 * D
2* b / A
s' =
572.052 mmDigunakan tulangan,
D 13
-
200
2.2.2. TULANGAN GESER
Gaya geser ultimit,
V
u=
64982 NV
c= 1/6*(√ f
c') * b * d =
249499 Nφ
.V
c=
149700 N > Vu Tdk. Perlu tul.geserφ
.V
s= V
u-
φ
.V
c=
--- NV
s=
--- NDiameter tul. yang digunakan, D --- Ambil jarak arah Y --- mm Luas tulangan geser, Av =π / 4 * D2* b / Sy= --- mm2 Jarak tulangan geser yang diperlukan ( arah X ) :
Sx= Av* f y* d / Vs= --- mm
Digunakan tulangan, D --- Jarak arah X --- mm Jarak arah Y --- mm
3. CORBEL
Tebal,h = h
5+ h
6=
1.55 m Eksentrisitas beban, e = b5/2 = 0.30 m Lebar,B
y=
20.00 m Momen ultimit,M
u=
3744.59 kNm Gaya geser ultimit,V
u=
12481.96 kN Ditinjau selebar 1 m, maka :M
u=
187.2295 kNmV
u=
624.0982 kN3.1. TULANGAN LENTUR
Momen rencana ultimit,
M
u=
187.23 kNm Mutu beton, K - 300 Kuat tekan beton,f
c' =
24.90 MPa Mutu baja, U - 39 Tegangan leleh baja,f
y=
390 MPaTebal beton,
h =
1550 mmJarak tulangan terhadap sisi luar beton,
d' =
150 mm Modulus elastis baja,E
s=
2.0E+05 Faktor bentuk distribusi tegangan beton,β
1=
0.85ρ
b=
β
1* 0.85 * f
c’/ f
y* 600 / ( 600 + f
y) =
0.02796Tebal efektif,
d = h - d' =
1400 mmLebar yang ditinjau,
b =
1000 mmMomen nominal rencana,
M
n= M
u/
φ
=
234.04 kNm Faktor tahanan momen,R
n= M
n* 10
-/ ( b * d ) =
0.11941Rn < Rmax (OK) Rasio tulangan yang diperlukan :
ρ
= 0.85 * f
c’ / f
y* [ 1 -
√
* [1 – 2 * R
n/ ( 0.85 * f
c’ ) ]
=
0.00031 Rasio tulangan minimum,ρ
min= 0.25%*1.4 / f
y=
0.00090 Rasio tulangan yang digunakan,ρ
=
0.00090Luas tulangan yang diperlukan,
A
s=
ρ ∗
b * d =
1256 mm2 Luas tulangan minimum,A
smin= M
u/ [
φ
* f
y* (d - e/2) ] =
480 mm2 Luas tulangan yang digunakan,A
s=
1256 mm2 Diameter tulangan yang digunakan,D
19 mm Jarak tulangan yang diperlukan,s =
π
/ 4 * D
2* b / A
s=
225.666 mmDigunakan tulangan,
D 19
-
200
A
s=
π
/ 4 * D
2* b / s =
1418 mm2 Untuk tulangan bagi diambil 50% tulangan pokok.A
s' = 50% * A
s=
628 mm2 Diameter tulangan yang digunakan,D
13 mmJarak tulangan yang diperlukan,
s' =
π
/ 4 * D
2* b / A
s' =
211.288 mmDigunakan tulangan,
D 13
-
200
A
s' =
π
/ 4 * D
2* b / s' =
664 mm2 3.2. TULANGAN GESERGaya geser ultimit,
V
u=
624098 N Faktor reduksi kekuatan geser,φ
=
0.60V
u* d / M
u=
4.67 >1 maka diambil = 1.00ρ
= A
s/ (b * d) =
0.10%V
c= [
√
f
c' + 120*ρ*V
u*d/M
u] * b * d / 7 =
1022300 NV
c= 1/6*(√ f
c') * b * d =
1164331 N Diambil,V
c=
1022300 Nφ
.V
c=
613380 N < Vu Perlu tul.geserφ
.V
s= V
u-
φ
.V
c=
10718 NV
s=
17863 NLuas tulangan geser, Av =π / 4 * D2* b / Sy= 331.83 mm2 Jarak tulangan geser yang diperlukan ( arah X ) :
Sx= Av* f y* d / Vs= 10142.59 mm
Digunakan tulangan, D 13 Jarak arah X 600 mm Jarak arah Y 400 mm
4. WING WALL
4.1. TINJAUAN WING WALL ARAH VERTIKAL
Tebal,
h = h
w=
0.50 m Lebar,H
x=
3.40 m Momen ultimit,M
u= M
uy=
1543.32 kNm Gaya geser ultimit,V
u=
1176.96 kN Ditinjau selebar 1 m, maka :M
u=
453.9183 kNmV
u=
346.1659 kN4.1.1. TULANGAN LENTUR
Momen rencana ultimit,
M
u=
453.92 kNm Mutu beton, K - 300 Kuat tekan beton,f
c' =
24.90 MPa Mutu baja, U - 39 Tegangan leleh baja,f
y=
390 MPaTebal beton,
h =
500 mmJarak tulangan terhadap sisi luar beton,
d' =
50 mm Modulus elastis baja,E
s=
2.0E+05 Faktor bentuk distribusi tegangan beton,β
1=
0.85ρ
b=
β
1* 0.85 * f
c’/ f
y* 600 / ( 600 + f
y) =
0.02796R
max= 0.75 *
ρ
b* f
y*[1 – ½*0.75*
ρ
b* f
y/ ( 0.85 * f
c’ )] =
6.59766 Faktor reduksi kekuatan lentur,φ
=
0.80 Faktor reduksi kekuatan geser,φ
=
0.60Tebal efektif,
d = h - d' =
450 mm Lebar yang ditinjau,b =
1000 mmFaktor tahanan momen,
R
n= M
n* 10
-6/ ( b * d
2) =
2.80196 Rn < Rmax (OK) Rasio tulangan yang diperlukan :ρ
= 0.85 * f
c’ / f
y* [ 1 -
√
* [1 – 2 * R
n/ ( 0.85 * f
c’ ) ]
=
0.00774 Rasio tulangan minimum,ρ
min= 0.25%*1.4 / f
y=
0.00090 Rasio tulangan yang digunakan,ρ
=
0.00774Luas tulangan yang diperlukan,
A
s=
ρ ∗
b * d =
3481 mm2Diameter tulangan yang digunakan,
D
22 mmJarak tulangan yang diperlukan,
s =
π
/ 4 * D
2* b / A
s=
109.197 mm Tulangan arah vertikal pada sisi dalam Wing wall :Digunakan tulangan,
D 22
-
100
A
s=
π
/ 4 * D
2* b / s =
3801 mm2 Untuk tulangan susut diambil 30% tulangan pokok.A
s' = 30% * A
s=
1044 mm2 Diameter tulangan yang digunakan,D
16 mmJarak tulangan yang diperlukan,
s' =
π
/ 4 * D
2* b / A
s' =
192.524 mm Tulangan arah vertikal pada sisi luar Wing wall :Digunakan tulangan,
D 16
-
150
A
s' =
π
/ 4 * D
2* b / s' =
1340 mm2 4.1.2. TULANGAN GESERGaya geser ultimit,
V
u=
346166 NV
c= 1/6*(√ f
c') * b * d =
374249 Nφ.V
c=
224550 N < Vu Perlu tul.geserφ.V
s= V
u-
φ.V
c=
121616 NV
s=
202694 NDiameter tul. yang digunakan, D 13 Ambil jarak arah Y 350 mm Luas tulangan geser, Av =π / 4 * D2* b / Sy= 379.24 mm2 Jarak tulangan geser yang diperlukan ( arah X ) :
Sx= Av* f y* d / Vs= 328.36 mm
Digunakan tulangan, D 13 Jarak arah X 300 mm Jarak arah Y 350 mm
4.2. TINJAUAN WING WALL ARAH HORISONTAL
Tebal,
h = h
w=
0.50 mLebar,
H
Y=
5.70 mMomen ultimit,
M
u= M
ux=
1000.42 kNmGaya geser ultimit,
V
u=
1176.96 kNDitinjau selebar 1 m, maka :
M
u=
175.512 kNmV
u=
206.485 kN4.2.1. TULANGAN LENTUR
Momen rencana ultimit,
M
u=
175.51 kNmMutu beton, K - 300 Kuat tekan beton,
f
c' =
24.90 MPaMutu baja, U - 39 Tegangan leleh baja,
f
y=
390 MPaTebal beton,
h =
500 mmJarak tulangan terhadap sisi luar beton,
d' =
50 mmModulus elastis baja,
E
s=
2.0E+05Faktor bentuk distribusi tegangan beton,
β
1=
0.85ρ
b=
β
1* 0.85 * f
c’/ f
y* 600 / ( 600 + f
y) =
0.02796R
max= 0.75 *
ρ
b* f
y*[1 – ½*0.75*
ρ
b* f
y/ ( 0.85 * f
c’ )] =
6.59766Faktor reduksi kekuatan lentur,
φ
=
0.80Faktor reduksi kekuatan geser,
φ
=
0.60Tebal efektif,
d = h - d' =
450 mmLebar yang ditinjau,
b =
1000 mmMomen nominal rencana,
M
n= M
u/
φ
=
219.39 kNmFaktor tahanan momen,
R
n= M
n* 10
-/ ( b * d ) =
1.08341 Rn < Rmax (OK)Rasio tulangan yang diperlukan :
ρ
= 0.85 * f
c’ / f
y* [ 1 -
√
* [1 – 2 * R
n/ ( 0.85 * f
c’ ) ]
=
0.00285Rasio tulangan minimum,
ρ
min= 0.25%*1.4 / f
y=
0.00090Rasio tulangan yang digunakan,
ρ
=
0.00285Luas tulangan yang diperlukan,
A
s=
ρ ∗
b * d =
1284 mm2Diameter tulangan yang digunakan,
D
16 mmTulangan arah horisontal pada sisi dalam Wing wall :
Digunakan tulangan,
D 16
-
100
A
s=
π
/ 4 * D
2* b / s =
2011 mm2 Untuk tulangan susut diambil 30% tulangan pokok.A
s' = 30% * A
s=
385 mm2Diameter tulangan yang digunakan,
D
13 mmJarak tulangan yang diperlukan,
s' =
π
/ 4 * D
2* b / A
s' =
344.625 mm Tulangan arah horisontal pada sisi luar Wing wall :Digunakan tulangan,
D 13
-
200
A
s' =
π
/ 4 * D
2* b / s' =
664 mm24.2.2. TULANGAN GESER
Gaya geser ultimit,
V
u=
206485 NV
c= 1/6*(√ f
c') * b * d =
374249 Nφ
.V
c=
224550 N > Vu Hanya perlu tul.geser minV
s= V
u=
206485 NDiameter tul. yang digunakan, D 13 Ambil jarak arah Y 300 mm
Luas tulangan geser, Av =π / 4 * D2* b / Sy= 442.44 mm2
Jarak tulangan geser yang diperlukan ( arah X ) : Sx= Av* f y* d / Vs= 376.05 mm
Digunakan tulangan, D 13 Jarak arah X 350 mm
Jarak arah Y 300 mm
PEMBESIAN WING WALL
D 2 2 - 1 0 0 ( S I S I D A L A M ) D 1 6 - 1 5 0 ( S I S I L U A R ) D13-200 (SISI LUAR) D16-150 (SISI DALAM) 2850 5750 600 500 2900 D22-100 D16-150 D13-200 D16-150 D13-350/300 500 350
PEMBESIAN ABUTMENT DAN PILE CAP D16-400 D25-150 D25-150 D25-150 1800 7000D25-200 D19-200 D16-200 D13-200 D13-150 D25-150 D16-300/350 D19-200 300 D13-300/600 D13-200 D19-200 D13-200 D13-200 D13-200 D13-200 D13-200 D19-200 D13-200 D16-200 D13-200 D19-200 D13-200 D16-400/400 350 550 1350 2000 750 1600 600 1200 200 200 1000 600 1200 800 800 750 500 2850 2900 3100