350kW Caterpillar Diesel Engine Generator Set for sale. Cat XQ 350, 60Hz, 480 Volts, 3

Phase, 7213 Hours. Built in 2000. Just pulled off rental line and is in good running

condition. Price $40,000.

STAMFORD 1540 KW

Harga:

rp.

233.333.333

Steam Turbine SST-060 (up to 6 MW)

(formerly known as AFA, CFA or CFR series)

Description

(4)

Features

Inlet

temperature

dry

saturated steam

up to 530 °C / 985 °F

Speed

according to driven machine

Exhaust pressure

Back pressure: up to 29 bar (a) /

420 psi or vacuum

BOILER

Boiler Type

: Water Tube

Rated Capacity

: 22.700 Kg/Hr from & AT 100 °C

Year of Manufacture : 2002

Serial No.

: 20410

Design Pressure

: 2,5 N/mm

2

Hydrotest Pressure

: 3,75 N/mm

2

Hydrotest No.

: KLR 0160571

(5)

Working Pressure

: 2,5 N/mm

2

(6)
(7)

LAMPIRAN 4

(8)

LAMPIRAN 5

OPERASI SISTEM TENAGA LISTRIK DAN ONE LINE

DIAGRAM KELISTRIKAN DI PKS SOGM

1.

TYPICAL ELECTRICAL DISTRIBUTION SYSTEM IN

PALM OIL MILLS

1.1 LAYOUT OF POWER GENERATORS, MAIN SWITCHBOARD, MOTOR

CONTROL PANELS AND POWER CABLES

Power Supply System In Palm Oil Mill

(9)

Different Parts of Power System

(a) Generating Sets

Comprising Steam, Diesel and Gas Types (Sinar Mas is considering installing

Biogas Engine)

(b) Main Cables

Linking Generating Sets and Main Switchboard. Commonly used are

PVC/PVC Single Core Copper Conductors. Due to flexibility.

(c) Main Switchboard

Comprising Generator Control Boards, Outgoing Distribution Panels,

Switching Panels and Capacitor Boards.

(d) Sub-Main Cables

Linking Main Switchboards and Sub-Switchboards. Commonly used are 4

Core Armoured Cable or 4 Core Paper Insulated Lead Alloy Sheathed Cable.

(e) Sub-Switchboard

Another name is Motor Control Panel. Starter Boards are located here.

(f) Loads

Comprising Electric Motor, Lighting, Heating, Air-Conditioner, Equipment.

1.2 MAIN SWITCHBOARD

1.2.1 MAIN SWITCHBOARD

These are attachment of panels to control power intake from generators

and power flow to load centres under control conditions.

The operations are executed by the use of ACB, MCCB, Protection

Equipment, Metering Equipment, Selector Switches, Change-over

Switches, P.F. Capacitor Banks, Bus-bars, Cables, etc.

The Main Switchboard comprises :

(10)

(b) Loads Control Panel

(c) Change-over Panel

(d) Automatic Power Factor Correction Panel

(e) Synchronising Panel

These panels are fabricated from 10 SWG and 12 SWG Sheet Metals for

Frame Work and Door/Covers respectively. These sheet metals are first

cleansed throughtly, given a phosphate treatment before being painted

with two undercoats of zinc chromate. The panels are then painted with

two layers of enamel orange on the outside and two layers of ‘white’ on

the inside.

1.2.2 GENERATOR CONTROL PANEL

Each generator control panel comprises :

(a) 1 No. 3 Pole ACB c/w under voltage release and auxiliary contacts

(b) 1 No. 3 Phase Magnetic-Thermal Overload Relays

(c) 1 No. Neutral Knife Switch

(d) 1 No. Earth fault Relay

(e) 1 No. Reverse Power Relay

(f) 1 No. 144 mm Square Voltmeter c/w Voltmeter Selector Switch

(g) 3 Nos. 144 mm Square Ammeter

(h) 1 No. 144 mm Square Kilo-watt (KW) meter

(i) 1 No. Kilo-watt Hour (KWh) meter

(j) 1 No. Hour-run meter

(k) 7 Nos. Measurement Current Transformers

(l) 4 Nos. Protection Current Transformers

(m)1 No. 1,5 kilo-ohm 3 Watts Voltage Trimmer

(11)

(o) 1 No. 144 mm Square Power Factor Meter

(p) 1 No. Reed Type Frequency Meter

(q) 10 Nos. 20/6A Control Fuse and Fuse Link

(r) Key Interlock Switch (if required)

(s) Tinned Copper Bus-bars and cabling

1.2.3 LOADS CONTROL PANEL

Power flow from these panels are control by :

(a) Moulded Case Circuit Breaker (MCCB)

(b) No Fuse Breaker (NFB)

(c) Fuse Switch (F/S)

(d) Switch Fuse (S/F)

(e) Socket Outlet

The advantages of MCCB or NFS over F/S and S/F are :

(a) No change of fuse is necessary

(b) Re-set when trigger by overload

(c) Small and compact

(d) Large ratings can be manufactured

Standard Ratings of TPN MCCB are :

(a) 30 A

(12)

(h) 1000 A

(i) 1250 A

1.2.4 CHANGE-OVER PANEL

(a) This can also be called Switching Panel.

(b) This is done by the use of 4 Pole Change-Over Switch and Main Switch

(ACB, MCCB, F/S).

(c) The purpose is to tap power supply from ‘Steam Bus-Bars’ OR ‘Diesel

Bus-Bars’.

(d) The advantage of this type of design is FLEXIBILITY IN OPERATIONS.

(e) At timers KEY INTERLOCK is provided to prevent mal-operation.

1.2.5 AUTOMATIC POWER FACTOR CORRECTION PANEL

(a) This comprises :

 Main Switch (to protect system)

 AC Contractor (to provide switching of capacitor Bank)

 Power Fuse (to protect capacitor bank)

 Electronic Power Factor Regulator (P.F. Controller)

 Measurement Current Transformer (to sense reactive power)

 Ammeter (measure amperes)

 Indicating Lights (to show no. of steps being switched on)

(b) Electronic Power Factor Regulator is normally available in steps of 6

and 12.

6-steps Regulator provide switching up to 6 capacitor banks.

12-step Regulator provide switching up to 12 capacitor banks.

(c) Measurement Current Transformer should be installed at location

(13)

correction of all inductive reactive load.

(d) The time response setting of Power Factor Regulator =

(e) Example : System has 6 x 65 KVAr Capacitor Banks Measurement

Current Transformer use 2000/5A.

Thus Time Response Setting =

=

=

= 0.1625

1.2.6 SYNCHRONISING PANEL

(a) This consists of :

 Synchronoscope (indicate phase sequence)

 Double Voltmeter (indicate bus-bar and incoming set voltage)

 Double Frequency (indicate bus-bar and incoming set

frequency)

 Selector Switch (to select gen-set to be paralleled)

 Synchronising Light (indicate phase sequence)

 Instrument Fuse (to protect meter and equipment)

(b) Synchronising Panel is require to assist in paralleling of generating

sets.

(c) Paralleling is done at the instance of :

 Equality is voltage

 Equality in frequency

 Equality in phase sequence

(14)

(d) Paralleling of generating sets than the above conditions can cause

serious damage to generators, switchgears and meters due to large

circulating current.

Legend and Item Specification

Item No. Symbol Description Make/Type

1 A Ammeter SACI 144 x 144 mm & 96 x 96 mm

2 V Voltmeter SACI 144 x 144 mm

3 Kw Kilowatt meter SACI 144 x 144 mm Unbalanced Load

4 Hz Frequency meter SACI 144 x 144 mm Reed Type

5 RPR Reverse Power Relay CROMPTON Electronic Type

6 PF Power Factor SACI 144 x 144 mm

7 KWh Kilowatt-hour meter KRIZIK Unbalance Load

8 HR Hour-run meter BAUSER Hour Counter

9 EF Earth Fault Relay ENGLISH ELECTRIC CAG12

10 OL Overload Relay TAMCO BHI

11 UVT Under Voltage Trip SACE

12 UVOV Under/Over Voltage Trip ELECTROMATIC SYY 155

13 TOR Thermal Overload Relay MITSUBISHI

14 VS Volt Selector Switch BRETER/BREMAS

15 VT Voltage Trimmer HERO

16 FS Fast/Slow Governor Switch BRETER/BREMAS

17 KS Knife Switch SOCOMEX

18 ACB Air Circuit Breaker SACE TPN Withdrawable Type

19 MCCB Moulded Case Circuit Breaker MITSUBISHI TPN

20 OSP Over Speed Protection MULON/OMRON

(15)

22 HWT Hot Water Temperature MULON/OMRON

23 SL Synchronising Light SIEMENS

24 SYN SCOPE Syncronising Scope SACI

25 DV Double Voltmeter SACI

26 DF Double Frequency meter SACI

27 SS Synchornising Key Switch FANAL

28 RS Reset Push-button SPRECHER + SHUH (S/S)

29 PS Parallleling Selector Switch EGA

30 PFR Power Factor Regulator BELUK

31 I/L Indicating Light SPRECHER + SCHUH (S/S)

32 CT Current Transformer NILSEN

33 FU HRC Fuse NILSEN/FEDERAL

34 TP Triple Pole -

35 TPN Triple Pole and Neutral -

(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)

LAMPIRAN 6

GOLONGAN DAN DAYA LISTRIK PLN TERPASANG

(25)

LAMPIRAN 7

Referensi

Dokumen terkait

The designed dual-band rectifiers use multi-stage dickson voltage multipliers DVM from 1 to 6 stages, and the main idea of this paper is to find the number of stages that offers the

Infant Motor Profile IMP Hammersmith Infant Neurological Examination HINE Others specify I do not use assessment tools Q14 On a scale of 1 to 5, where 1 is very often and 5 is never,