350kW Caterpillar Diesel Engine Generator Set for sale. Cat XQ 350, 60Hz, 480 Volts, 3
Phase, 7213 Hours. Built in 2000. Just pulled off rental line and is in good running
condition. Price $40,000.
STAMFORD 1540 KW
Harga:
rp.
233.333.333
Steam Turbine SST-060 (up to 6 MW)
(formerly known as AFA, CFA or CFR series)
Description
Features
Inlet
temperature
dry
saturated steam
up to 530 °C / 985 °F
Speed
according to driven machine
Exhaust pressure
Back pressure: up to 29 bar (a) /
420 psi or vacuum
BOILER
Boiler Type
: Water Tube
Rated Capacity
: 22.700 Kg/Hr from & AT 100 °C
Year of Manufacture : 2002
Serial No.
: 20410
Design Pressure
: 2,5 N/mm
2Hydrotest Pressure
: 3,75 N/mm
2Hydrotest No.
: KLR 0160571
Working Pressure
: 2,5 N/mm
2LAMPIRAN 4
LAMPIRAN 5
OPERASI SISTEM TENAGA LISTRIK DAN ONE LINE
DIAGRAM KELISTRIKAN DI PKS SOGM
1.
TYPICAL ELECTRICAL DISTRIBUTION SYSTEM IN
PALM OIL MILLS
1.1 LAYOUT OF POWER GENERATORS, MAIN SWITCHBOARD, MOTOR
CONTROL PANELS AND POWER CABLES
Power Supply System In Palm Oil Mill
Different Parts of Power System
(a) Generating Sets
Comprising Steam, Diesel and Gas Types (Sinar Mas is considering installing
Biogas Engine)
(b) Main Cables
Linking Generating Sets and Main Switchboard. Commonly used are
PVC/PVC Single Core Copper Conductors. Due to flexibility.
(c) Main Switchboard
Comprising Generator Control Boards, Outgoing Distribution Panels,
Switching Panels and Capacitor Boards.
(d) Sub-Main Cables
Linking Main Switchboards and Sub-Switchboards. Commonly used are 4
Core Armoured Cable or 4 Core Paper Insulated Lead Alloy Sheathed Cable.
(e) Sub-Switchboard
Another name is Motor Control Panel. Starter Boards are located here.
(f) Loads
Comprising Electric Motor, Lighting, Heating, Air-Conditioner, Equipment.
1.2 MAIN SWITCHBOARD
1.2.1 MAIN SWITCHBOARD
These are attachment of panels to control power intake from generators
and power flow to load centres under control conditions.
The operations are executed by the use of ACB, MCCB, Protection
Equipment, Metering Equipment, Selector Switches, Change-over
Switches, P.F. Capacitor Banks, Bus-bars, Cables, etc.
The Main Switchboard comprises :
(b) Loads Control Panel
(c) Change-over Panel
(d) Automatic Power Factor Correction Panel
(e) Synchronising Panel
These panels are fabricated from 10 SWG and 12 SWG Sheet Metals for
Frame Work and Door/Covers respectively. These sheet metals are first
cleansed throughtly, given a phosphate treatment before being painted
with two undercoats of zinc chromate. The panels are then painted with
two layers of enamel orange on the outside and two layers of ‘white’ on
the inside.
1.2.2 GENERATOR CONTROL PANEL
Each generator control panel comprises :
(a) 1 No. 3 Pole ACB c/w under voltage release and auxiliary contacts
(b) 1 No. 3 Phase Magnetic-Thermal Overload Relays
(c) 1 No. Neutral Knife Switch
(d) 1 No. Earth fault Relay
(e) 1 No. Reverse Power Relay
(f) 1 No. 144 mm Square Voltmeter c/w Voltmeter Selector Switch
(g) 3 Nos. 144 mm Square Ammeter
(h) 1 No. 144 mm Square Kilo-watt (KW) meter
(i) 1 No. Kilo-watt Hour (KWh) meter
(j) 1 No. Hour-run meter
(k) 7 Nos. Measurement Current Transformers
(l) 4 Nos. Protection Current Transformers
(m)1 No. 1,5 kilo-ohm 3 Watts Voltage Trimmer
(o) 1 No. 144 mm Square Power Factor Meter
(p) 1 No. Reed Type Frequency Meter
(q) 10 Nos. 20/6A Control Fuse and Fuse Link
(r) Key Interlock Switch (if required)
(s) Tinned Copper Bus-bars and cabling
1.2.3 LOADS CONTROL PANEL
Power flow from these panels are control by :
(a) Moulded Case Circuit Breaker (MCCB)
(b) No Fuse Breaker (NFB)
(c) Fuse Switch (F/S)
(d) Switch Fuse (S/F)
(e) Socket Outlet
The advantages of MCCB or NFS over F/S and S/F are :
(a) No change of fuse is necessary
(b) Re-set when trigger by overload
(c) Small and compact
(d) Large ratings can be manufactured
Standard Ratings of TPN MCCB are :
(a) 30 A
(h) 1000 A
(i) 1250 A
1.2.4 CHANGE-OVER PANEL
(a) This can also be called Switching Panel.
(b) This is done by the use of 4 Pole Change-Over Switch and Main Switch
(ACB, MCCB, F/S).
(c) The purpose is to tap power supply from ‘Steam Bus-Bars’ OR ‘Diesel
Bus-Bars’.
(d) The advantage of this type of design is FLEXIBILITY IN OPERATIONS.
(e) At timers KEY INTERLOCK is provided to prevent mal-operation.
1.2.5 AUTOMATIC POWER FACTOR CORRECTION PANEL
(a) This comprises :
Main Switch (to protect system)
AC Contractor (to provide switching of capacitor Bank)
Power Fuse (to protect capacitor bank)
Electronic Power Factor Regulator (P.F. Controller)
Measurement Current Transformer (to sense reactive power)
Ammeter (measure amperes)
Indicating Lights (to show no. of steps being switched on)
(b) Electronic Power Factor Regulator is normally available in steps of 6
and 12.
6-steps Regulator provide switching up to 6 capacitor banks.
12-step Regulator provide switching up to 12 capacitor banks.
(c) Measurement Current Transformer should be installed at location
correction of all inductive reactive load.
(d) The time response setting of Power Factor Regulator =
(e) Example : System has 6 x 65 KVAr Capacitor Banks Measurement
Current Transformer use 2000/5A.
Thus Time Response Setting =
=
=
= 0.1625
1.2.6 SYNCHRONISING PANEL
(a) This consists of :
Synchronoscope (indicate phase sequence)
Double Voltmeter (indicate bus-bar and incoming set voltage)
Double Frequency (indicate bus-bar and incoming set
frequency)
Selector Switch (to select gen-set to be paralleled)
Synchronising Light (indicate phase sequence)
Instrument Fuse (to protect meter and equipment)
(b) Synchronising Panel is require to assist in paralleling of generating
sets.
(c) Paralleling is done at the instance of :
Equality is voltage
Equality in frequency
Equality in phase sequence
(d) Paralleling of generating sets than the above conditions can cause
serious damage to generators, switchgears and meters due to large
circulating current.
Legend and Item Specification
Item No. Symbol Description Make/Type
1 A Ammeter SACI 144 x 144 mm & 96 x 96 mm
2 V Voltmeter SACI 144 x 144 mm
3 Kw Kilowatt meter SACI 144 x 144 mm Unbalanced Load
4 Hz Frequency meter SACI 144 x 144 mm Reed Type
5 RPR Reverse Power Relay CROMPTON Electronic Type
6 PF Power Factor SACI 144 x 144 mm
7 KWh Kilowatt-hour meter KRIZIK Unbalance Load
8 HR Hour-run meter BAUSER Hour Counter
9 EF Earth Fault Relay ENGLISH ELECTRIC CAG12
10 OL Overload Relay TAMCO BHI
11 UVT Under Voltage Trip SACE
12 UVOV Under/Over Voltage Trip ELECTROMATIC SYY 155
13 TOR Thermal Overload Relay MITSUBISHI
14 VS Volt Selector Switch BRETER/BREMAS
15 VT Voltage Trimmer HERO
16 FS Fast/Slow Governor Switch BRETER/BREMAS
17 KS Knife Switch SOCOMEX
18 ACB Air Circuit Breaker SACE TPN Withdrawable Type
19 MCCB Moulded Case Circuit Breaker MITSUBISHI TPN
20 OSP Over Speed Protection MULON/OMRON
22 HWT Hot Water Temperature MULON/OMRON
23 SL Synchronising Light SIEMENS
24 SYN SCOPE Syncronising Scope SACI
25 DV Double Voltmeter SACI
26 DF Double Frequency meter SACI
27 SS Synchornising Key Switch FANAL
28 RS Reset Push-button SPRECHER + SHUH (S/S)
29 PS Parallleling Selector Switch EGA
30 PFR Power Factor Regulator BELUK
31 I/L Indicating Light SPRECHER + SCHUH (S/S)
32 CT Current Transformer NILSEN
33 FU HRC Fuse NILSEN/FEDERAL
34 TP Triple Pole -
35 TPN Triple Pole and Neutral -