27th FEBRUARY 2017
SHARING PENGELOLAAN HEAT RATE
PLTU TANJUNG JATI B
Ari Basuki
www.pln.co.id |
TJB 1&2 TJB 3&4
Project Scheme
Plant Owner (Lessor) Plant Operator
(Lessee)
O&M Contractor
established by
•Medco Group (80.1%)
•AF Consult (Finland) (19.9%)
•Durasi 23 tahun
established by
• KOMIPO (Korea) (51%)
• PT.PJB (49%)
•Durasi 20 tahun
Coal Shipping PT. Arpeni Pratama Ocean Line PT. Bahtera Adhiguna
Plant Capacity (Net) 660.8MW x 2Units 661.1MW x 2Units
Supplier/ Contractors
• TOSHIBA (Turbine/Generator)
• B&W/Black&Veatch (Boiler & BOP)
• Toshiba Plant Systems and Services (Erection Work)
• Mitsui Engineering & Shipbuilding (Civil)
• Mitsubishi Heavy Industry (Chimney)
• TOSHIBA (Turbine/Generator)
• Mitsubishi Heavy Industry (Boiler)
• Black & Veatch (BOP)
• Toshiba Plant Systems and Services (Erection Work) • Mitsui Engineering & Shipbuilding (Civil & Chimney )
Fuel
Commercial Operation
(since) Unit 2: Nov 1, 2006Unit 1: Oct 1, 2006 Unit 3 : Oct 13, 2011Unit 4 : Jan 1, 2012
Outline of the Tanjung Jati B Project
Finance Lease Scheme
PT. Central Java Power
PT. PLN (Persero)
Coal (from South East Kalimantan ) ,7.6 Mil ton consumption/ year
www.pln.co.id |
PLN
CJP
(PT.Central Java Power)
EPC Contractors (SPDL/SWJO)
• Acquisition of Land
• Purchase of Power Plant from EPC Contractors • Lease Power Plant & Land to PLN
• Procurement of Loan • Repayment of Loan
• Lessee of Power Plant & Land
• Construction of Transmission Line
• Fuel Supply
• Operation & Maintenance
• Payment of Finance Lease Installment
Supply / Construction Contract
Finance Lease (Leasing & Operation) Agreement
Lenders
(JBIC & Commercial Banks)
Loan Agreements
GOI
Liquidity Facility
JBIC
MOF Letter / JBIC Letter
Finance Lease (Construction & Warranty) Agreement
FLA II
FLA I
• Establishment of CJP
• Construction of Power Plant • Arrangement of Finance
• Necessary support to CJP, as sponsor
Operator PT. TJBPS
Coal , Fuel Limestone
Supplier
Coal Shipping PT. APOL
www.pln.co.id |
PLN
CJP
(PT.Central Java Power)
EPC Contractors (SPDL/SCJO)
• Acquisition of Land
• Purchase of Power Plant from EPC Contractors • Lease Power Plant to PLN
• Procurement of Loan • Repayment of Loan
Expansion Finance Lease (Leasing & Operation) Agreement
Lenders
(JBIC & Commercial Banks)
Expansion Loan Agreements
GOI
Liquidity Facility
JBIC
MOF Letter / JBIC Letter
Expansion Finance Lease (Construction & Warranty) Agreement
Umbrella Note of Mutual Understanding
FLA V
FLA IV
• Lessee of Power Plant
• Construction of Transmission Line
• Fuel Supply
• Operation & Maintenance
• Payment of Finance Lease Installment
Expansion Supply / Construction Contract
• Establishment of CJP
• Construction of Power Plant • Arrangement of Finance
• Necessary support to CJP, as sponsor
Operator PT. KPJB Coal , Fuel Limestone
Supplier
Coal Shipping PT. BAg
www.pln.co.id |
Skema Bisnis & Cashflow TJB
PLN TJB
Coal Supplier O&M Operator
O&M Suppliers
Lessor (CJP) PLN Pusat
Escrow Agent (SMBC)
PLTU Tanjung Jati B (4 x 660MW)
Pelanggan
Energi Listrik
Batubara
Spare part & Service O&M Service
O&M Fee
Payment
Droping Monthly OM&Fuel, Monthly MNR for FLIb, Semi Annual Profit Sharing (if any)
Monthly MNR for FLIb
Semi annnual Profit Sharing (if any)
Semi Annual FLI
Singapore Tokyo
Rekening Listrik
www.pln.co.id |
FLI CALCULATION
7
5 ~ 55%**
*: for the purpose of this presentation, not including EADTX and FLI Adjustment Amount. **: 5 ~ 55% of a weighted average of FLIb during Phase 1 is applied for FLIb during Phase 2 ***: 5 ~ 100% of FLIb during Phase 1 is applied for FLIb during Phase 2
5 ~ 100%*** 3 years
12 years (Phase 1) 8 years (Phase 2) FLIb varies every 3 years
FLIb is fixed during whole lease period : FLI b)
Phase 1 : D (calculated every 6 months)
TJB3&4
FLI* = FLIb + D
FLI* = FLIb + D
TJB1&2
www.pln.co.id |
FLI CALCULATION UNIT 1-2
8
Basic concept of FLI calculation is “Risk & Profit Sharing” between PLN and CJP.
FLI consists of (i)Fixed Portion (“FLIb”) and (ii)Variable Portion (“D”).
Fuel Cost
Variable Portion & Lease Payment
to be determined during each 6 month Payment Period
Lease Payment
Lease Payment
Phase One
(1st – 12th years)
PLN actual costs
PLN actual costs
PLN
Network Loss
Variable Portion (“D”)
PLN Proft O&M Cost
Phase Two
(13th year – 20th year (plus Delay Period))
Fixed Portion (FLIb)
to be determined on Commercial Operation Date (“COD”) and Every 3
years for 1st 12 years (Phase One)
Fuel Cost
O&M Cost
PLN
Network Loss
Variable Portion (“D”)
PLN Proft
FLIb O&M Cost
FLIb
Network Loss
www.pln.co.id |
FLI CALCULATION UNIT 3-4
9
Fuel Cost
O&M Cost
Variable Portion & Lease Payment
to be determined during each 6 month Payment Period
Lease Payment
Phase One
(1st – 12th years)
PLN actual
costs
Network Loss
Variable Portion
FLIb
Fixed Portion (FLIb)
fxed during whole Phase One
FLIb FLIb
US ¢ 2.55/kWh flat PLN
Fuel Cost
O&M Cost
Lease Payment
PLN actual
costs
Network Loss
Variable Portion
FLIb
Phase Two
(13th – 20th years plus Delay
D:100% D:100%
FLIb for Phase One (1st to 12th year) to be determined at COD and every 3
years
[FLIb] = (Expected Proft by operation of TJB on FLIb Determination Date)
= {(Expected revenue by electricity sales) – (Generating Costs)}
= {ATb x [100% – TDL] – (OMb+Fb+Pb)} x THpp x UC x 80% x YRb
Unit Capacity [kW] (UC)
x x Capacity Factor( 80%) x
Exchange Rate [Yen/Rp.]
(YRb)
For COD: average of “OM” used to refer to the audited report of IP and PJB [Rp/kWh]
For others (every 3years): O&M Costs [Rp./kWh] for the payment period including FLIb Determination date
For COD: (average cost of fuel [Rp./kg] purchased by PLN prior to COD) x (Unit Heat Rate) / (HHV of fuel) For others (every 3years): Fuel Costs [Rp./kWh] for the payment period including FLIb Determination date
(PLN Sales Tarif [Rp./kWh]) x (Transmission and Distribution Loss[%])
FLIb, but not less than minimum FLI determined in the Finance Lease
Agreements (US ) 2.0/kWh )
[FLIb] = (Weighted average of FLIb during Phase One) x 5~55%
Calculation of FLI Fixed Portion (“FLIb”)
x
Expected Fuel Cost (Fb) Expected O&M
Cost (OMb)
FLIb Network Loss
(TDL)
FLIb for Phase Two (13th to 20th (plus Delay Period, if any) )
4383 [hours]
Private (Finance Company)
Comparison with other Scheme
Finance Arrange
(Loan Procure)
Plant Owner EPC
O&M
Fuel
Transmission &
Distribution
PLN PLN
Private (Developer, Owner and Lessor)
Private (Developer, Owner and Lessor) PLNPLN PLNPLN
PLN PLN
PLN PLN Private (Developer and Owner)
Private (Developer and Owner)
TJB FLA scheme, a “Build, Lease and Transfer (BLT) scheme”, is a unique category of
“electricity supply business with private sector investment”.
- SV of PLN OM&F
- Power Plant OM&F Works (in a unique case)
PLN Power Plant
PPA (BOO, BOT)
FLA (BLT)
HEAT RATE
www.pln.co.id |
Net Plant Heat Rate (NPHR)
NPHR = Gross PHR – Pemakaian Sendiri (PS)
kCal ¢ Pemakaian Energi yang dikonversi (minimalkan)
NPHR satuan :
---kWh ¢ Jumlah Produksi Energi Listrik (maksimalkan)
kCal ¢ sangat dipengaruhi oleh efektifitas sistem heat transfer pembangkit
www.pln.co.id |
PENYEBAB UMUM KENAIKAN HEAT RATE
www.pln.co.id |
HEAT RATE UNIT 1-2
`
15
Actual degradation (%)
# 1 2,64
www.pln.co.id |
PERFORMANCE TEST VS NATURAL DEGRADATION
16
Keterangan:
www.pln.co.id |
HEAT RATE OPERASIONAL UNIT 1 (2007 – 2016)
17
EPC Performance test Sep 2006
- Unit Net Heat Rate : 2290 kcal/kWh
- Turbine Net Heat Rate : 1914 kcal/kWh - Boiler Efficiency : 89.6%
www.pln.co.id |
18
EPC Performance test Sep 2006
- Unit Net Heat Rate : 2279 kcal/kWh
- Turbine Net Heat Rate : 1904 kcal/kWh - Boiler Efficiency : 89.6%
- Aux Pwr consumption : 46.52 MW
www.pln.co.id |
DATA HEATRATE 1&2
www.pln.co.id |
HEAT RATE (PERFORMANCE TEST)
21
NPHR Unit 3
www.pln.co.id |
NPHR Unit 4
www.pln.co.id |
DEGRADATION FACTOR (%)
(MANUFACTURE DESIGN)
Item Boiler Turbine Unit
Degradation factor/month (%)
(months 0 - 18) 0.012 0.025 0.037
Degradation factor/month (%)
(months 19 - ~) 0.012 0.014 0.026
www.pln.co.id |
EFFICIENCY BOILER (%)
24
Boiler Efficiency Unit 3
Ef
Boiler Efficiency Unit 4
www.pln.co.id |
TURBINE HEAT RATE
25
Turbine Gross HR Unit 3
Tu
Turbine Gross HR Unit 4
www.pln.co.id |
Data Realisasi NPHR berdasarkan
CF
26
CFnet(%) 70.51 68.98 61.99 88.16 84.65 77.32 65.47 77.80 42.88 73.80 75.38
JAN FEB MAR APR MEI JUN JUL AGS SEP OKT NOV
www.pln.co.id |
EFFORTS TO MAINTAIN NPHR
• Coal quality analysis : daily and CoA supplier
• Coal fineness test 60 – 70% 200mesh and <2% 50mesh • Sootblower operation
• CTC (Condenser Tube Cleaning) - Turbine • LOI (Lost In Ignition) fly ash analysis (<1%) • Performance test every 6 months each Unit
• Monitoring critical operation parameter (main steam, cond.vaccuum,etc)
Mill maintenance (Grinding table and roller) to maintain coal fineness
• Heater element of Air Heater replacement or cleaning • LPH, HPH, condenser tube cleaning
• Heat Exchanger element cleaning • Boiler tube cleaning
• Pemeliharaan dengan konsep Modular system (roll in roll out equipment)
Pre-combustion
Operation
www.pln.co.id |
DAILY COAL QUALITY ANALYSIS
www.pln.co.id |
COAL FINENESS ANALYSIS
www.pln.co.id |
LOI (%)
www.pln.co.id |
LOI (%)
MERIT ORDER SEPTEMBER 2016
MERIT ORDER OKTOBER 2016
34
35
36
37
TERIMA KASIH
39
Performance Test 1&2
www.pln.co.id |
PURPOSE
1. To perform maintenance most efficiently
2. To maintain the original performance of the equipment
3. To prevent the re-occurrence of failures and any degradation in operating conditions
4. To minimize the number of breakdowns and reduce the frequency of failure and the duration of repair time
www.pln.co.id |
PROGRAMS
Time base, by daily,
weekly, monthly, yearly
lubricating the
rotating equipment, battery check,
calibration, visual inspection, table and grinding roller of coal mill
Maintenance Program
To correct specifc
problems that have been identifed in the power plant, in the shortest possible time
Implemented to
un-critical equipment
As follow up to
service request issued by Operator
Condition base
Used the tools to
take the data
Applied vibration
analysis, CMSA, tribology, oil tr. Analysis,
www.pln.co.id |
CONTINUED…
Every 2 years each
Unit
Maintenance Program
Due to plant has
forced derated or forced outage
Strategy: stocking
critical
part/equipment in the warehouse in order to expedite recovery time
To solve the problem
www.pln.co.id |
Overhaul (Planned Outage)
Type Duration Interval Work Scopes
B- Class (Minor) 37 days 2 years Maintenance of the only low
pressure turbine
OPERATION
www.pln.co.id |
PURPOSE
1. Accomplishing the highest level of performance
www.pln.co.id |
PROGRAMS
Daily meeting
Local patrol check
Issued Service
Request
Communicate with
Dispatcher
Entry operation data
to operator log sheet
Make disturbance
record
Operation Program
Setting control
standard for Start up and shutdown of
unit
Building up &
application of PTW system
Set up SOP & Work
Instruction
Set up internal
environmental guidelines
Maintain flue gas
parameter through CEMS
Thorough operation
www.pln.co.id |
Continued…
Develop the pertinent operating
procedures and instructions
Implement & utilize PEMS
Periodical implementation of the
performance tests every six months per unit
Fineness coal analysis
Loss of Ignition analysis
Monitoring the in-house power
consumption
Operation
Train the Operators as the
high-qualifed specialists of operation
Implement various
www.pln.co.id |
UNIT 3&4 KPI ACHIEVEMENT
KPI YEAR
2012 2013 2014 2015 2016
EAF 90.19 95.10 94.61 94.03 93.99
EFOR 1.59 0.02 0.77 1.13 1.06
www.pln.co.id |
www.pln.co.id |
NPHR Unit 3
www.pln.co.id |