PABX SIEMENS Hipath Series ( 1120 / 1150 / 1190 )

I Cara Install CD PABX SIEMENS Ke PC

1. Insert CD SIEMENS ke Disk Drive (Running) 2. Klik 2x English.

3. Next Next Next Next … (Install Shield Wizard Complate) 4. Finish.

5. Exit.

II Buka Program Hipath

1. Klik Start - All Program - Siemens Hipart 1100 - Manager (klik 2x) 2. Klik Connect 3. Password : 3 1 9 9 4 klik Ok - Ok Menu Utama : Besik - Ring Assignment - Configuration - Day - Night - MSN - Configuration - Day - Night - Phone Book

- Code / Name / Number - Extension

- Extension / Name - Call Charge Accounts

Extension / Value / Expanded / With Limits Advanced - Extension - General - CD Interface - Key Programming - Flexible Number - ISDN Phone - Class Of Service - Category Day - Category Night - Permission List - Prohibition List - Group - Pick Up Group - Call Group - Hunting Group - External WMI - UCD Group - Associated Group - External Music - ISDN - Configuration - ISDN Slot - Advanced Configuration - Trunk - General - Trunk Group - Flexible Number

(2)

- System Setting - General - Caller List -Music On Hold - Escape Extension - Operator - Charge Factor - Regional Setting - Service Codes - Date and Time - Emergency Numbers - Software Up Date - Remote Administration - Modem - Passwords - Report - Holidays - Schedule - Weekday / Jam ….. - Entrance Telephone -Interface Position - Ring Assignment - Open Permission - MSN - Day Incomming - Night Incomming - Day Outgoing - Night Outgoing - Trunk Assosiation - Fax - DID - Pseudo Port - Routing Menu - Timers - General - Extension - Trunk - PXC Information - General Information - PBX Layout - Slot Allocation

III Motherboard Hipath 1120

IV Motherboard Hipath 1150

Expand Module : 2 CO / 10 Ext Expand Module : 0 CO / 12 Ext 12 34 L1 L2 12 34 56 78 x1 x2 x3 x4 12 34 56 78 x5 x6 x7 x8 12 34 56 78 k1 k2 k3 k4 USB V24 PSU 12 34 56 78 L1 L2 x1 12 34 56 78 x3 x4 x5 12 34 56 78 x7 x8 x9 MOH 12 34 56 78 k1 k2 k3 k4 12 34 56 78 k5 k6 k7 k8 US B V24 12 34 56 78 12 34 56 78 12 34 56 78 12 34 56 78 12 34 56 78 12 34 56 78

(3)

Expand Module : 8 CO Expand Module : 4 CO L = Line X = Ext Slot 2 Slot 1 Slot 4 Slot 3

Basic Hipath 1150 = 2 CO / 10 Ext 12 34 56 78 L1 L2 L3 L4 12 34 56 78 L5 L6 L7 L8 12 34 56 78 L1 L2 L3 L4 x6

(4)

III Cara Program

1. Buka Program Hipath

1. Klik Start - All Program - Siemens Hipart 1100 - Manager (klik 2x) 2. Klik Connect

3. Password : 3 1 9 9 4 klik Ok - Ok

2. Matikan False Tone : Advanced - System Setting - General = Hilangkan Conteng di False Tone Update . 3. Buat Country (IM Spanish) dan Language (English) : Advance - System Setting - Regional Setting 4. Date and Time : Advance - System Setting - Date and Time.

5. Membuat COS dengan Level : Advance - Class Of Service - Prohibition List 1 List 2 List 3

0 00 01 100 017 02 101 107 03 104 101 04 Update 104 05 0809 06 Update 07 09 100 101 104 Update

- No Permision : Class 0 Intern

- Prohibition List 1 : Class 1 Lokal (batasi : ( 0 - 100 - 101 - 104 ) Update - Prohibition List 2 : Class 2 SLJJ (batasi : ( 00-017-107-101-104-0809 ) Update

- Prohibition List 3 : Class 3 HP (batasi : ( 01-02-03-04-05-06-07-09-100-101-104 ) Update - Permission List 1

- Permission List 2 - Permission List 3

- Total Permision : Class 7 Bebas

6. Membuat Class Of Service di Ext : Advance - Class Of Service = Category Day (COS Siang) = Category Night (COS Malam) Lihat tabel pilihan dibawah, pilih dengan klik panah wawah

Extension : Pilih no extensionnya. ( Ext 11 s/d 50 )

Trunk Group : Pilih trunk grupnya ( 0 / 890 / 891 / 892 / ………. / 899)

Catagori : Pilih classnya ( No Permision / Prohibit List 1 - 2 - 3 / Total Permision )

7. Membuat Nama Ext : Basic - Extension - Name

Ganti Nomor Extension : Advanced - Extension - Flexible Numbering (Ganti Colom Ext)

8. Membuat Incomming Line di Ext : Basic - Ringing Assignment = Day dan Night (isi di First Attendand) Klik Colom Trunk setelah itu di tabel First Attendant, Pilih Ext yang akan bunyi dengan menggunakan panah kanan.

9. Outgoing Call / Trunk Group : Advance - Trunk

General : Tiap-tipa line dapat dibuat untuk : Bidirectional : Incomming : Outgoing Trunk Group : 0 / 1 / 2 / 3 s/d 10

Access Code : 0 / 890 / 891 / 892 / 893 s/d 899 Overflow Group : off / All / 0 / 890 / 891 / 892 s/d 899

(5)

10. Fax Detection : Advance - Extension : General : Bold Ext U/ Fax, Pilih Type : Conteng Data Equipment Pilih Titik di Data Equipment (Fax-Moden) Lalu Update

: Basic - Ringing Assignment - Configuration - Mode (Select = Auto FAX) dan bila fax terpasang Secara Outomatis Kolom Extension For Fax dari off ke No Ext Fax

11. Save Data dari PABX ke Computer : File - Save Back up - Browse - (Pilih di Drive mana) Save. 12. Untuk DISA : Advance - FAX-DID : Routing Menu

Index Route

0 11 bila Tekan " 0 " bunyi di ext 11 1 12 bila Tekan " 1 " bunyi di ext 12 2 13 bila Tekan " 2 " bunyi di ext 13 3 14 bila Tekan " 3 " bunyi di ext 14

Update

: Basic - Ring Assignment - Configuration - Colom Mode = Deactivated (Ganti) FAX-DID Semua Di Colom Trunk Modenya Ganti.

13. Membuat Tombol Line di Pesawat Profiset 3030 : (Pesawat harus terpasang) Ext Key Tombol

11 Kiri Atas 1 update

Kiri Atas 2 update

Kiri Atas 3 update

Kanan atas 1 update

Kanan atas 2 update

Kanan atas 3 update

Kiri Bawah

14 Setting Untuk Billing System : Advance - System Setting (Serial to Print di CONTENG )

15 Untuk Lihat Data Mentah SMDR dari Hipath : Start - All Program - Siemens Hipath - Call Detail Recording Settingan PABX dan Komputer Bila Sudah Cocok dapat di Lihat :

Star - All Program - Accessoris - Commonication - Hyper Terminal Boud Rate : 19.200 / Data Bit : 8 / Parity : None / Stop Bit : 1

16. Untuk Up Date Software Hipath : Star - All Program - Siemens Hipath 1100 - Software Up Date - dst 17. Untuk Reset PABX : Program Manager - File - Return To Factory Configuration.

18. Save Program Data PABX : Program Manager - File - Save Back up - Browse - pilih Drive - Save 19. Trasfer Data dari Computer ke PABX : Program Manager - File - Restore Back Up - Browse - dst 20. Bila Incomming Ringing Bunyinya Telat Lakukan : Advance - Trunk - General

(Tiap Line pada Clip Ana Protokol: Pilih Disable)

21. Untuk Pick up harus dibuat Group : Advance - Group - Pickup Group

22. Melihat Versi PABX / Susunan Card Expand / Slot : Advance - PBX Informasi

23. Bila Pest Ext Pest Panasonic Flash Time harus dirubah biar tombol Flash berfungsi untuk Transfer : Advance - Timer - Extension (buat Flash 70 ms)

Repdial Repdial 13 ext 14 ext Repdial First Parameter 801 Trunk 802 Trunk 803 Trunk 12 ext Service Call Trunk Key Trunk Key Trunk Key

(6)

PROGRAM MANUAL : Buka Program =  - 95 - 31994

Code Prog Trg Group Trunk COS Ext

1. Rubah COS di Ext 111 0 11 11

12 13 14

15 

2. Rubah Password (Contoh 12345) 180 12345 12345 3. Elektronic Lock Password Reset 126 No Ext

4. Override 144 No Ext 0 / 1 0 = Tanpa permisi

1 = Permisi dan beep 2. Rekam Greeting Untuk Disa : Prog Code Rcord/Play Sel

137 9 07 Bicara #

Sel : 07 untuk Griting Siang 0 07 Play #

Sel : 08 untuk Griting Malam

Sel : 09 untuk Call Forward Prog Code Rcord/Play Sel

137 9 08 Bicara #

0 08 Play #

Prog Code Rcord/Play Sel

137 9 09 Bicara #

0 09 Play #

3. Rubah Password :  - 95 - 31994 CARA PAKAI

1. Transfer  No Ext Recall - No Ext (Recall = Flash = Hook Switch Bila Sibuk Tekan (  ) Bila Sibuk Tekan Recall atau  2 Recall 2. Telp Keluar Tekan Line No Telp Angkat - 0 - No Telp

Line 1 : Kiri atas

Telp Keluar dgn Group 8 9 0 s/d 8 9 9 No Telp

3. Call Pick Up 57 '57

4. Call Pick Up Direct  59 No Ext '59 No Ext 5. Elektronic Lock Pass 93 No Ext 00000 12345 12345

word Change Pass Asli Pass Baru Pass Baru

6. Elektronic Lock Aktif  66 Password Password Elektonic dan Walking sama aslinya Elektronic Lock No Aktif # 66 Password (00000) ( nolnya 5 kali)

Walking COS  508 Extension Password Line No Telp

7. Internal Call Forward  1 1 No Ext

Call Forward Cancel # 1 1

8. Call Forward No Answer  1 4 No Ext

Call Fwd Cansel # 1 4

9. DND Aktif  9 7

DND Cansel # 9 7

10 Call Back  5 7

Call Back Cansel # 5 7

(7)

Masalah - Masalah

1. Bila Software Siemens di Uninstall tidak bisa : Lakukan pada layar kanan bawah icon xC Klik kanan dan Exit