These results refer only to the materials received for testing purposes. They do not imply any warranty. Usage should be suited to local conditions and the materials employed. Any proprietary rights should be respected. All rights reserved.

TEST REPORT

PT Wacker Chemicals Indonesia KawasanPergudangan Taman Tekno BSD CitySektor XIUnit H-3 No. 28 B, Tangerang Selatan

Indonesia

Sample Plaster

Customer

PT Sumber Inti Perkasa Pembangunan Komplek pergudangan dan industry Safe n Lock. Block V2 no. 3318 Sidoarjo-Indonesia

Date 2nd March 2022

Tested by Jakarta Technical Center

1. Introduction

Plaster samples received from Eco Mortar (PT Sumber Inti Perkasa Pembangunan) was tested per EN 1015-11 and EN 1015-12. The tests results were summarizedin thetablegiven below.

2. Test Results

Project no

Customer Name PT Sumber Inti Perkasa Pembangunan

Sample Name Plaster

Notes

Sample Plaster 100

Walocel 40000 PFV As informed by cus-

tomer

Vinnapas 4115 N As informed by cus-

tomer

Water Demand 18

Workability Good

(Standard Plaster)

Tensile Adhesion Strength According to EN 1015-12 - 2 mm thickness

Standard Condition 28d SC

Mean value (N/mm2) 0.22 Standard deviation

(N/mm2) 0.06

Failure pattern CFA

Heat Ageing

14d SC + 14d 70deg C + 1d SC

Mean value (N/mm2) 0.22 Standard deviation

(N/mm2) 0.06

Failure pattern CFA

(13)

Page 2 of 3

These results refer only to the materials received for testing purposes. They do not imply any warranty. Usage should be suited to local conditions and the materials employed. Any proprietary rights should be respected. All rights reserved.

Project no JAKTC 0145

Customer Name PT Sumber Inti Perkasa Pembangunan

Sample Name Plaster

Flexural and Compressive, According to EN 1015-11 - 28d S.C

Flexural Strength 40x40x160 mm

Mean value (N/mm2) 1.73 Standard deviation

(N/mm2) 0.19

Compressive Strength 40x40 mm

Mean value (N/mm2) 2.82 Standard deviation

(N/mm2) 0.12

SC: 23°C, 50 % Relative humidity, d = days

3. Pictures

4. Comments

The workability of Eco Mortar Plaster at the water demand of 18% was found to be good.

Tensile adhesion strength after 28d Standard Condition (SC) (SC: 23°C, 50% relative humidity) was found to be 0.22 N/mm2.

Tensile adhesion strength after heat ageing (14d SC+14d 70ºC+1d SC) was found to be 0.22 N/mm2.

Standard Condition Heat Ageing Condition

(14)

Page 3 of 3

These results refer only to the materials received for testing purposes. They do not imply any warranty. Usage should be suited to local conditions and the materials employed. Any proprietary rights should be respected. All rights reserved.

Flexural and compressive strength was found to be 1.73 N/mm2 and 2.82 N/mm2 re- spectively.

(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)