Compare this to a PC that has EcoStruxure Machine Expert V1.1 installed during installation, for example EcoStruxure Machine Expert V1.2.7. The Machine Expert installer is used to configure and install the EcoStruxure Machine Expert software.
Logoff Procedure
Firewall Settings
Controller - HMI Communication with User Rights Management Activated
Resetting Device User Rights
Overview
Reset via EcoStruxure Machine Expert Logic Builder
NOTE: When you reset user rights management to default values, access to FTP, HTTP and OPC-UA servers is denied until you set your individual username and password.
Reset via Controller Webserver
USER MANAGEMENT > USER ACCOUNTS MANAGEMENT > RESET TO DEFAULT
Reset via Controller Assistant
Reset Without Credentials
Deactivating Device User Rights
Deactivating via EcoStruxure Machine Expert Logic Builder
WARNING
UNAUTHENTICATED ACCESS AND MACHINE OPERATION
Failure to follow these instructions can result in death, serious injury, or equipment damage
Result: Access the controller is now available without credentials
Deactivating via Controller Webserver
MAINTENANCE > USER MANAGEMENT > USER ACCOUNTS MANAGEMENT
Deactivating User Rights for the Simulation Device in EcoStruxure Machine Expert Logic Builder
Managing Device User Rights by Call Parameters
Starting Controller Assistant
Managing Device User Rights Using the Scripting API
Scripting for Using Online Services
Providing Specific Credentials for Online Services
Providing Default Credentials for Online Services
Scripting for Enforced Password Renewal
Including User Rights While Cloning the SD Card
Including User Rights While Cloning the USB key
Hardware/Firmware Information V1.2.7
Hardware/Firmware Information
Library Information V1.2.7
Library Information
Version Identification
Mitigated Anomalies
Known Operational Anomalies
Software Information V1.2.7
Software Information
Release Notes History
EcoStruxure Machine Expert V1.1
Safety-Related Products
ILM070: S/N ≥ 2506064503 (DOM ≥ 11.09.2015)
ILM100: S/N ≥ 2506058831 (DOM ≥ 18.08.2015)
ILM140: S/N ≥ 2506059644 (DOM ≥ 21.08.2015)
Performance and System Limitations of New TM5CSLC•00FS Firmware Version
New Features
A TMS bus port allows the connection of Smart Communication modules, mounted by simple latch on the left side of the controllers. A TM3 bus port allows the connection of TM3 expansion modules, mounted by simple latching on the right side of the controllers.
PacDrive LMC Controls
The Modicon M262 Logic/Motion Controller has built-in 4 high-speed digital inputs and 4 high-speed digital outputs connected to the controller using screw terminals on the front of the controllers. A QR code printed on the front of Smart Communication controllers and modules provides a link to the Schneider Electric product maintenance page.
PROFINET
TM262M: for the motion control of up to 16 synchronized axes In combination with a TM5CSLC•00FS for safety-related control applications up to SIL3. Modicon M262 Logic/Motion Controllers can be combined with Modicon TM3, Modicon TM5 and Modicon TM7 offerings using Sercos III, EtherNet/IP and CANopen bus connectors.
Accessories TMS
TM3 EtherNet/IP Bus Coupler
New features
Limitations
TM3 Expert I/O
TM3XFHSC202
TM3XFHSC202G
TM3XHSC202
TM3XHSC202G
TM3 Standard I/O
LXM32S Servo drives
LXM32S Firmware Version Requirements
Standard Plus and Advanced Plus System Integration
During rollout, Sercos PacDrive LMC Pro, PacDrive LMC Pro2 and PacDrive LMC Eco check that the configuration matches the connected physical devices.
User functions
Supported features of LXM62 Standard Plus
Supported features of LXM62 Advanced Plus
Supported features of the UserMotorTypePlate library
Fast Device Replacement
Lexium ILM62 Integrated Servo Drives
OEM00068334 Configuring fast outputs (pulse generators) for an M241 controller caused the programming software to shut down. PEP0439107R Communication between the Controller Assistant and an M241 controller is now possible when connected to the second ETH2 network interface.
Version Identification Safety Libraries
ApplicationLogger
AsyncManager
CommonMotionTypes
EMailHandling
FileFormatUtility
If an inline modification is detected while the function block is in progress, all REFERENCE TO and POINTER TO type input parameters are updated. The new global variable FFU.GCL.G_xOnlineChangeAllowed indicates whether an online modification can be performed on function blocks executed outside the FileFormatUtility library.
GMC Independent Altivar
GMC Independent Lexium
GMC Independent PLCopen
HttpHandling
Library EnableSwitch_SE_SF
Library PLCopen_SF
Library Preventa_SafeMotion
M262Diagnostics
M262 Encoder
M262 PLCSystem
MachineAssistantServices
MotionInterface
MqttHandling
PackML
PD_PacDriveLib
PLCopen MC part 1
PreventaSupport
Robotic
RoboticModule
SchneiderElectricRobotics
SchneiderElectricRobotics Parameters
SchneiderElectricRobotics Toolbox
SercosDriveUtility
SercosMaster
SlcRemoteController
TcpUdpCommunication
TeSys Island
UserMotorTypePlate
Libraries
New Features for Machine Expert Installer and Online Help Machine Expert Installer
Online Help
NOTE: When HTML5 help is on the web, the restrictions do not exist.
New Features EcoStruxure Machine Expert Project Update
Functional View
Smart Template
Modules can be added using the Add Module dialog providing more information and flexibility in terms of versioning, etc. The user code, user configuration, and resolved library version are used to generate the code for the smart template.
Migration Strategy of Smart Template
Create a new empty project in EcoStruxure Machine Expert
Copy and paste the source code
Add the modules to the new project via Add module and adapt the configuration according to the old project
Code Analysis
ETEST
The exported result file contains the start, end time and duration of each test case. The result of each test case will be printed to the shell console, if executed via scripting.
Diagnostics
The ETEST standard methods (Prepare, Execute, Finalize, CleanUp) are optional for test cases and test resources are optional for test cases and test resources.
Controller Assistant
Device Assistant
New Features for EcoStruxure Machine Expert - Safety Overview
HTML 5
Compatibility EcoStruxure Machine Expert Overview
For SoMachine Motion compiler version V4.4 or later, the initialization order of data unit type arrays. For SoMachine Motion compiler version V4.4 or later, properties with an accompanying type variable are exported as read-only in the symbol configuration.
CAUTION
For SoMachine Motion V4.4 compiler versions, a compiler error will be generated when writing to variables located at %I* addresses. For SoMachine Motion V4.4 compiler versions, FB_EXIT is now called for instances allocated on the stack before the holding scope is returned.
INOPERABLE EQUIPMENT
NOTE: If you extract a project archive in EcoStruxure Machine Expert that was created with SoMachine or SoMachine Motion, and Options are selected in the Extract Project Archive dialog box, your EcoStruxure Machine Expert installation may be modified and the devices may appear is missing
Failure to follow these instructions can result in injury or equipment damage
NOTE
Compatibility EcoStruxure Machine Expert - Safety Overview
However, EcoStruxure Machine Expert - Safety with this release does not support reusing a project built on EcoStruxure Machine Expert - Safety with LMCx01 system to EcoStruxure Machine Expert - Safety with M262 system or vice versa.
Identified Incompatible Project Updates
TM5SAI4AFS
TM5STI4ATCFS
Machine Expert Installer
In the Online Help, the description of some LED indicators of the TM5CSLCx00FS is present. OEM00070844 In the Online Help, the parameter information on the encoder resolution of the motors (EncoderResolutionRotary) is present.
EcoStruxure Machine Expert
The programming software GUI is no longer missing Chinese translations. OEM00067888 Using the Cut command in an FBD (Function Block Diagram) no longer causes the programming software to stop.
EcoStruxure Machine Expert - Safety
The Vijeo-Designer no longer closes with HMIConnection Mode> IP Address (Fast TCP). OEM00075268 An unhandled exception is no longer caused by copying and pasting a variable within the trace configuration.
Limitations for the Release of TM262M••
OEM00071263 In the online help, the description for the TM5CSLCX00FS cycle time has been improved and more detailed information is provided. OEM00072267 In the SafeLogger, a safety related message is not displayed if the TM5CSLCx00FS is not in operational state due to an incorrect encoder resolution.
Limitations for the Release of TM262••
Limitations for the Release of PacDrive Controllers
Immediate Addressing
Symbols are automatically updated with their new immediate address bindings, provided they are attached to the address in the I/O map dialog of the corresponding device editor, and not just an 'AT' statement in the program itself.
UNINTENDED EQUIPMENT OPERATION
In one particular system configuration tested, operating with a Sercos cycle time of 1 ms, the state of the SafeModulOK parameter of one safety-related module changes from TRUE to FALSE. Solution: Use 2ms or 4ms as the Sercos cycle time if appropriate for your application, or adjust the security time parameters slightly (for example maxDataTransportTime).
Documentation - Mitigated Anomalies Documentation
EcoStruxure Machine Expert V1.1 SP1
OEM00077977 When the connection was interrupted during the transfer phase download FTP over TLS, the controller task stopped without information (no error message). OEM00077889 When accessing variables not available in the controller was requested by Machine Expert Protocol, an internal error occurred on the controller with.
M262 - Motion
62 / 62 ILM
OEM00077894 If SoMachine V4.3 or an earlier version was installed on the computer, the IP address used by the PC is not correct. OEM00077911 An M262 is not detected by USB and cannot be connected to EcoStruxure Machine Expert.
HMISCU Controllers
Install EcoStruxure Machine Expert directly on a PC or use Ethernet to connect a PC to the controller. Solution: If you run MC_CamIn with an SSI encoder as master and that SSI encoder is not connected to the M262, an error is reported.
Known Operational Anomalies Libraries
When using direct addressing in the EcoStruxure Machine Expert project, an advisory message was displayed each time you performed a build (F11) of the project. Machine Expert EcoStruxure opened the SLC Remote Control instance instead of Fast Motion Programming.
Documentation - Known Operational Anomalies Documentation
If the master position value leaves the defined cam position range, the cam signals that the end of the cam profile has been reached. Implement all necessary measures to ensure that a task is only buffered if sufficient distance from the position value to the end of the cam position range can be respected.
EcoStruxure Machine Expert V1.2
This means that the buffer job is activated regardless of whether the parent has left the cam position area in the positive or negative direction. The master unit can also leave the cam position range due to jitter if the master unit rests at a position close enough to the positive or negative limit of the cam position range.
TM3 Serial Line Bus Coupler
Depending on the number of analog I/O and/or safety modules used, the maximum allowed number of TM3 I/O modules may be reduced.
TM5 EtherNet/IP Bus Coupler
Plug&Work (Machine Assistant)
NOTE: To help keep your Schneider Electric products safe and protected, it is in your best interest to implement cybersecurity best practices as outlined in the Cybersecurity Best Practices document provided on the Schneider Electric website.
M241 / M251 Logic Controllers
M262 Motion Controllers
M262 Cybersecurity Implementation
M262: TMSES4 Support
M262L20MESE8T
M262M25MESS8T
M262M35MESS8T
M262L10MESE8T
M262M15MESS8T
M262: Single Wiring Coexistence (SWC) Architecture
NOTE: It is a good practice to stop the Ethernet communication when the Sercos bus is not in phase 4.
M262 Modifying the Default IP Address of the USB Port
Servo Drives
M241/M251 Controllers
LXM32S
Known Operational Anomalies ATV340S
The contents of the ARRAY object type read for an ETH_R structure are not correct when displayed on an HMI. The contents of elements (i_byFirmVersion,i_byFirmVersion) in the PLC_Rdata structure are not correct when displayed on an HMI.
TM3 Bus Coupler Serial Line TM3BCSL
FtpRemoteFileHandling
SqlRemoteAccess
RoboticsAutoTune
Hoisting
TcpUdp communication library: If more than one protected (Transport Layer Security) TCP server was active at the same time, the system watchdog may appear due to higher system load. Calibration status information is retained in the status output even if the function block is disabled.
New Features for Machine Expert Installer
TcpUdpCommunication Library: MethodSockOpt_EnableKeepAliveExtendedto configure keep alive for the TCP client and server to detect communication interruption on the M262 controller. No known malfunctions detected for EcoStruxure Machine Expert V1.2. 1)If you are using a virtual machine, downloading the online help only works correctly if the Accelerate 3D graphicsis option is disabled in the VM settings.
New Features EcoStruxure Machine Expert Motion Design Object
SQL Gateway
Cybersecurity Improvement
Python
New Project Dialog
Browse Cross References
Selecting the machine's security group in the Expert Machine Installer now automatically installs the components needed to program security-related applications. Also refer to the suggestions below and the chapter Cybersecurity information for managing user rights, page 10.
Cybersecurity Information for Safety-Related Use Cases
Overview of the validated EcoStruxure Machine Expert - Safety version with the appropriate safety-related firmware. Server configuration with floating license that was not completely cleaned up caused a long start time (>30 min) of EcoStruxure Machine Expert - Safety.
EcoStruxure Machine Expert V1.2.1
Hardware/Firmware information
EcoStruxure Machine Expert V1.2.2
Quality Improvement for TM5 Sercos Bus Coupler and TM5 Safety Controllers
New Features for EcoStruxure Machine Expert - Safety
Mitigated Anomalies - Machine Expert Installer
Known Operational Anomalies - EcoStruxure Machine Expert
EcoStruxure Machine Expert V1.2.3
Quality Improvement for TM5 Ethernet/IP Bus Coupler
M262 - OPC UA Client
As a result, customer projects containing this library (EcoStruxure Machine Expert V1.1) cannot be converted to EcoStruxure Machine Expert V1.1 SP1 or later without the error message "An unhandled exception has occurred in your application."
OpcUaHandling
TeSys island
Renamed the term safety to SIL (Safety Integrity Level) on the items in the library.
Project Example
TeSys island DTM
SI-5713 It is not possible to synchronize more than one cam diagram between Motion Sizer and Machine Expert. For new safety projects created with Machine Expert - Safety V1.2, V1.2.1 and V1.2.2 it is not possible to use structured text (ST) POUs.
EcoStruxure Machine Expert V1.2.4
Lexium LXM28S
Modicon TM3 Bus Coupler
Modicon TM3 Standard I/O
There is now an Absolute mode that can be selected as an alternative to the existing Relative and RampIn auxiliary launch modes when starting the cam. Be aware that the digital outputs set in this task will only be sent to the device after 2 cycles.
Documentation
MK-939 When the MC_CamIn function block is executed with the RampIn child start mode, unnecessary ramping no longer occurs, but ramping is not necessary because the axis already starts at the correct position based on the cam profile definition. M262-5137 SysTimeRtcSet: After SHUTDOWN, the controller's real-time clock (RTC) is lost if set with the SysTimeRtcSet function.
TM5CSLC•00FS
M262-5335 When in a distributed architecture, with TM3BCEIP, if the diagnostics for the analog modules TM3AQ2 and TM3AQ4 are disabled, CPU exception occurs, after downloading the application. Solution: The diagnostics are enabled by default - do not change the diagnostics settings for these two modules: TM3AQ2 and TM3AQ4.
CommonToolbox
When set to None, the values of the analog inputs will shift into the read data buffer, causing the wrong data value to be read into the software or controller.
Mathematics
NOTE: If you are using templates and examples that have not been updated with the EcoStruxure Machine Expert V1.2.4 update, you may get the Update Project dialog. If you open an example or template for the first time, you must update to have the correct and matching libraries and other necessary support.
Quality improvement for Lexium 32 DTM
LXM32DTM-4 Resolve problem with transferring old SoMove file to new LXM32 drive.
EcoStruxure Machine Expert V1.2.5
Modicon M258 Logic Controllers and Modicon LMC058 Motion Controllers
The retain file was deleted with a compatible update of the LMC image in the controller assistant. Documentation: The variable from the SmartInfeed product generation simulation was xProductLenghtVariance instead of xProductLengthVariation in the online help.
EcoStruxure Machine Expert V1.2.6
Modicon M262 Motion Controller
OPC UA Client
Motion Control Library Guide: It is not clearly described which stop ramp is used by the blockMC_Stop function. BOC-1089 The PreCompiler generates an error if a project with M262M controller is used where ARRAY OF PLCO.MC_CAM_ID is used in the code.