Supplementary Table 1
AUROC with age adjustment
AUROC without age adjustment
P valuea
2D PERIPAPILLARY RNFL THICKNESS (µm)
Global 0.9687 0.9594 0.3141
Temporal 0.8871 0.8543 0.3232
Superior 0.9476 0.9365 0.3141
Inferior 0.9725 0.9659 0.3286
Nasal 0.8711 0.8294 0.2149
ST 0.9407 0.9330 0.3760
SN 0.8982 0.8693 0.2149
IT 0.9707 0.9645 0.3286
IN 0.9294 0.9051 0.2149
3D PERIPAPILLARY RETINAL VOLUME(mm3) FOR CA1 (inner diameter 2.5mm, outer diameter 3.5mm)
CA1
Global 0.9402 0.9365 0.4244
Temporal 0.8514 0.8338 0.3920
Superior 0.9346 0.9284 0.3286
Inferior 0.9670 0.9635 0.3805
Nasal 0.8674 0.8365 0.2149
ST 0.9226 0.9165 0.3492
SN 0.9135 0.9038 0.3286
IT 0.9555 0.9472 0.3286
IN 0.9573 0.9503 0.3286
a P values were calculated with FDR correction for multiple testing using the method of Benjamin and Hochberg (1995).
3D = three-dimensional; 2D = two-dimensional; AUROC = area under receiver operating characteristics value; CA1 = smallest circumpapillary annulus bounded by circular grids with diameters of 2.5 and 3.5 mm; IN = inferior-nasal; IT = inferior-temporal; RNFL = retinal nerve fiber layer; SN = superior-nasal; ST = superior-temporal.