Axial strength of circular concrete-filled steel tube columns — DOE approach

Manojkumar V. Chitawadagi

a,

, Mattur C. Narasimhan

a,1

, S.M. Kulkarni

b,2

aDepartment of Civil Engineering, National Institute of Technology, Karnataka, Surathkal, Mangalore-575025, India

bDepartment of Mechanical Engineering, National Institute of Technology Karnataka, Surathkal, Mangalore-575025, India

a r t i c l e i n f o

Article history:

Received 30 September 2009 Accepted 9 April 2010

Keywords:

Concrete-filled steel tubes Columns

Circular tubes Ultimate axial load Axial shortening

a b s t r a c t

This paper presents the effect of changes in diameter of the steel tube (D), wall thickness of the steel tube (t), strength of in-fill concrete (fcu), and length of the tube (L) on ultimate axial load (Pue) and axial shortening at the ultimate point (δue) of circular Concrete Filled steel Tubes (CFT). Taguchi’s approach with an L9 orthogonal array is used to reduce the number of experiments. With the help of initial experiments, linear regression models are developed to predict the axial load and the axial shortening at the ultimate point. A total of 243 circular CFT samples are tested to verify the accuracy of these models at three factors with three levels. The experimental results are analyzed using Analysis Of Variance to investigate the most influencing factor on strength and axial shortening of CFT samples. Comparisons are made with predicted column strengths using the existing design codes, AISC-LRFD-2005 and EC4-1994.

©2010 Elsevier Ltd. All rights reserved.

1. Introduction

Concrete-Filled steel Tubular (CFT) columns have been increas- ingly used in many modern structures, such as dwelling houses, tall buildings, and arch bridges [1] The composite tubular columns have better structural performance than that of bare steel or re- inforced concrete structural members. Steel hollow sections act as reinforcement for the concrete [2]. Steel–concrete composite members have advantageous qualities such as sufficient strength, ductility and stiffness. Generally, CFT columns have demonstrated a sufficient load capacity, ductility and energy absorption capacity.

Concrete filled steel tubes are an economical column type, as the majority of the axial load is resisted by the concrete, which is less expensive than steel [3]. The steel tube serves as the formwork for casting the concrete, which reduces the construction cost. No other reinforcement is needed since the tube acts as longitudinal and lat- eral reinforcement for the concrete core.

The confining effect causes the core concrete to behave in a triaxial stress state while the core concrete prevents the wall of the steel hollow section from buckling inward. Experimental studies on concrete-filled steel tubes have been on-going for many decades. A review of available experimental studies shows that the main parameters affecting the behaviour and strength of

Corresponding author. Tel.: +91 0824 247000 3041, Mobile: +91 9449837148.

E-mail addresses:[email protected],[email protected],

[email protected](M.V. Chitawadagi),[email protected] (M.C. Narasimhan),[email protected](S.M. Kulkarni).

1 Tel.: +91 0824 247000x3041, Mobile: +91 9449163427.

2 Tel.: +91 0824 247000x3656, Mobile: +91 9449086656.

concrete-filled columns are: the geometrical parameters, such as the slenderness, the diameter to wall thickness (D/t) ratio and the initial geometry of the column, and the mechanical parameters, such as the strength of the steel and concrete [4]. A primary deterrent to widespread use of CFTs is the limited knowledge regarding their behavior. A number of factors complicate the analysis and design of concrete-filled steel tubes [5]. Although CFT columns are suitable for tall buildings in high seismic regions, their use has been limited due to a lack of information about the true strength and inelastic behavior of CFT members [6]. Although the use of CFT columns is becoming more commonplace, concrete core confinement is not well understood [7].

The local buckling phenomenon was studied by many re- searchers. For axially loaded thin-walled steel tubes, local buckling of the steel tube does not occur if there is sufficient bond between the steel and concrete [8]. Based on the experimental results of 114 centrally loaded stub columns, Kenji Sakino et al. concluded that the difference between the ultimate strength and the nominal squash load of circular CFT columns, which are provided by confin- ing the concrete, can be estimated as a linear function of the tube yield strength [9]. The improvement of the structural properties of CFT columns is mainly due to the composite action of the steel hollow section and the core concrete. The short-term composite action is such that the steel tube, in addition to acting as reinforce- ment, confines the concrete, resulting in a significant increase in concrete compressive strength, while the confined concrete not only relieves the steel tube of some load but also delays and mod- erates buckling deformations in the steel tube [10]. Eighty-one specimens were tested by Gupta et al. to investigate the effect of diameter andD/tratio of a steel tube on the load carrying capac- ity of the concrete filled tubular columns. TheD/tratio was 25–39.

0143-974X/$ – see front matter©2010 Elsevier Ltd. All rights reserved.

doi:10.1016/j.jcsr.2010.04.006

(2)

Nomenclature

D Outer diameter of the steel tube L Length of the steel tube t Wall thickness of the steel tube W Water content

fcu Cube compressive strength of concrete at 28 days Puc-G Generalized regression model to predict ultimate

axial load

Puc-N Predicted ultimate axial load based on initial nine experiments

Puc-R Predicted ultimate axial load based on the Response Surface Method

Pue Measured ultimate axial load Vfs Volume fraction of steel Vfc Volume fraction of concrete

δuc-N Predicted axial shortening at ultimate load based on initial nine experiments

δuc-R Predicted axial shortening at ultimate load based on the Response Surface Method

δue Measured axial shortening at ultimate point

It was seen that for smallerD/tratio, a steel tube provides a good confinement effect for concrete [11].

O’Shea and Bridge (2000) found that the strength and ductility decrease with increasing diameter to thickness (D/t) ratios and confirmed from the tests that the load and the bond conditions significantly influenced the axial load behaviour [3]. Investigations from Toshiaki Fujimoto et al. (2004) noted that care appears to be necessary when using high strength concrete in combination with an ordinary strength steel tube. It is understood that the use of high strength concrete reduces the deformation capacity of concrete-filled tubes. However, the deformation capacity can be improved by using a high strength steel tube or a compact steel tube section. The ductility behavior would be improved by confining the concrete within a high strength steel tube or within a tube having a smallD/tratio [12]. In the state of art report by Shanmugam and Lakshmi (2000), it was concluded that intensive research is required on the interaction between steel and concrete, the effect of concrete restraining local buckling of steel plate elements, effect of steel section, confining concrete, etc. [13].

There is a discrepancy in the analytical models proposed by different researchers for evaluating the strength of a CFT column and the effect of confinement [6]. The discrepancy was also observed while comparing predictability of different codes for CFTs under axial compression and flexure. One experimental study on circular CFTs with various concrete strengths under axial load, by Georgios Giakoumelis and Dennis Lam, observed that Eurocode 4 (EC4) provides a good prediction of the axial strength of CFT columns, 17% was the largest difference between the experimental and calculated value on the axial capacity. The predicted axial strengths using ACI (American Concrete Institute) and AS (Australian Standards) were 35% lower than the results obtained from experiments [8]. Design codes for composite steel–concrete columns such as EC4, BS (British Standards) 5950, BS 5400 and ACI-318-83 do not consider the local buckling of slender steel plates [14]. Both EC4 and AISC codes conservatively estimate the axial load capacity of slender rectangular CFT samples [15].

A series of tests were performed, by Dennis Lam and Christo- pher Williams,to consider the behaviour of short composite columns under axial compression. Comparisons between predic- tions from EC4, ACI-318 and AS with experimental results was made and it was found that ACI-318 and AS gave better predic- tion for axial capacity of CFTs than EC4 [16]. Experimental and

theoretical studies have been carried out on behaviour of short tubular steel columns by Campione and Scibilia. The effects of dif- ferent geometry and dimensions of the cross sections were inves- tigated for a given length of the CFT and simplified expressions to predict ultimate load of short columns were proposed [17]. Pre- vious research on slender circular composite columns shows that the strength of the column decreases as the slenderness ratio in- creases [18]. For thin walled composite filled columns under axial compression, strength was found to decrease with the increase of slenderness ratio and strength reduction occurred at a much higher rate for slender columns with slenderness ratio equal to or less than 24 [19]. Some studies were carried out by Manojkumar and Narasimhan (2009) on CFT beams to predict moment capacity us- ing linear regression models based on a minimum number of ex- periments [20].

The present work is intended to study the parameters affecting the ultimate axial load carrying capacity and corresponding axial shortening (ductility) of the CFT using the Design Of Experiments (DOE) approach. The prime factors considered to affect ultimate axial load and corresponding axial shortening under axial compression are diameter, wall thickness of the steel tube, strength of in-fill concrete and length of the CFT. The effect of the slenderness ratio on the ultimate load carrying capacity of the CFT is considered by selecting three lengths of CFTs namely 1 m, 0.7 m and 0.5 m. The Length to diameter ratio (L/D) for the samples selected is 7.8–22.5 and theD/tratio is 22.3–50.8. For each length of the CFT column, 81 combinations are tested (Table 1), consisting of three diameters, three wall thicknesses and three grades of in- fill concrete (33=27). For each combination of CFT, three samples are tested and the average value is considered. A total of 243 experiments are conducted to determine the effect of these four factors on the responses, namely ultimate axial load (Pue) and axial shortening at the ultimate point (δue).

2. Experimental programme

In the present investigation CFTs with three different diameters each with three different wall thicknesses are selected (D/t = 22.3–50.58). Three different grade concrete mixes ofM30,M40and M50 are considered (Table 2). Design mixes are prepared using locally available Portland Pozzolana Cement (PPC), crushed granite jelly (12.0 mm down) and river sand. The mix designs of these three grades of concrete are made based on the guidelines of IS 10262- 1982 [21]. The mix proportions adopted for the three grades are shown inTable 3. In order to ensure proper compaction, a higher degree of workability i.e. 80–100 mm slump is adopted for the concrete mixes and is achieved by using silica fume and super plasticizer as admixtures. Standard cubes (100 mm size) are tested to determine the compressive strength of the concrete mixes at 28 days.

Cold-formed, mild steel tubes, with yield strength of 250 MPa and 1000 mm, 700 mm and 500 mm in length are used in the present investigation. These tubes are seam welded. The edges of the tubes are finished. The outer surface of the steel tubes are painted to avoid corrosion. The insides of the tubes are wire brushed and the deposits of grease and oil, if any, are removed.

The allowableD/tratios of the steel hollow sections are less than the limits specified in EC4-1994 [22] and thus premature buckling failure of CFT specimens is avoided.

Steel tubes are kept in an upright position in a specially prepared stand, while pouring the concrete. The bottom end of the steel tube is covered tightly with polythene sheet and concrete is poured from the top. Concrete fills the steel tube in approximately four equal layers with each layer being well compacted. The top of the concrete is trimmed off using a trowel and the steel tube is kept undisturbed until it is taken out from the stand after 24 h

(3)

Table 1

Details of CFT samples tested for each 1 m, 0.7 m and 0.5 m length of the column.

Sl. no. Notation No. of samples Notation No. of samples Notation No. of samples

1 D1t1M30 3 D2t1M30 3 D3t1M30 3

2 D1t2M30 3 D2t2M30 3 D3t2M30 3

3 D1t3M30 3 D2t3M30 3 D3t3M30 3

4 D1t1M40 3 D2t1M40 3 D3t1M40 3

5 D1t2M40 3 D2t2M40 3 D3t2M40 3

6 D1t3M40 3 D2t3M40 3 D3t3M40 3

7 D1t1M50 3 D2t1M50 3 D3t1M50 3

8 D1t2M50 3 D2t2M50 3 D3t2M50 3

9 D1t3M50 3 D2t3M50 3 D3t3M50 3

No. of samples D1series 27 D2series 27 D3series 27

Total no. of CFT samples tested for each length 27+27+27=81

Note:M30=Concrete Mix of characteristic strength of 30 N/mm2with cube strength at 28 days is 42.4 N/mm2. M40=Concrete Mix of characteristic strength of 40 N/mm2with cube strength at 28 days is 51.7 N/mm2. M50=Concrete Mix of characteristic strength of 50 N/mm2with cube strength at 28 days is 60.7 N/mm2.

Table 2

Factors and levels selected for each length of the CFT column.

Levels Factors

Diameter of the steel tube (mm) Wall thickness of the steel tube (mm) Strength of in-filled concrete (N/mm2)

Level-1 44.45 (D1) 1.25 (t1) 42.4 (fcu1)

Level-2 57.15 (D2) 1.6 (t2) 51.7 (fcu2)

Level-3 63.5 (D3) 2.0 (t3) 60.7 (fcu3)

Table 3

Concrete mix proportions.

Sl. no Mix designation Binder (B) (kg/Cub.m) Proportions B:FA:CA W/B ratio

Super plasticizer % (by wt of binder)

28 days Compressive

strength (fcu) (N/mm2) Slump (mm) Cement Silica fume

1 M30 390 20 1:1.80:2.28 0.45 2.0 42.4 90

2 M40 410 20 1:1.76:2.16 0.40 2.2 51.7 80

3 M50 430 20 1:1.67:2.04 0.38 2.6 60.7 80

to keep in water for curing. The theoretical densities of the CFTs are computed using the law of mixtures and a comparison of these values is made with actual density of CFTs. Densities of all the CFTs are near to the theoretical densities. Such an illustration is shown inTable 4for a typical 1 m length of samples.

3. Test setup and procedure

The tests are conducted on CFTs, in a 1000 kN capacity Column Testing Machine, at 28 days of age. Linearly Varying Displacement Transducers (LVDT) are placed at one fourth, mid-height and three fourths heights of the sample to measure the lateral deformation.

Prior to the actual tests, a pre-load of approximately 2–5 kN is applied so that the platens of the testing machine are firmly attached to both ends of the specimen. The axial load is then applied slowly by careful manipulation of the loading-valves. The readings of the applied load, axial shortening and LVDT readings are recorded at appropriate load increments.

4. Results and discussion

4.1. Design of experimental approach

In order to save time and material cost involved in experi- mentation, a lesser number of experiments is desired. Therefore, the Taguchi method [23] was introduced as a useful engineering methodology to find the proper combination of structural param- eters and to perform the analysis with the minimum number of experiments. Therefore nine experiments are carried out accord- ing to the combination levels indicted by an L9 orthogonal array (Table 5) for each length of the sample. An orthogonal array helps

in determining the minimum number of trials that are necessary, and the factor levels for each parameter in each trial. A general L9 orthogonal array consists of three factor levels each at three levels.

For each sample three replicas were tested.

4.2. Main effect plots and analysis of variance

After performing experiments as per Taguchi’s experimental design, the main effect plots for ultimate axial load and axial shortening at ultimate load are plotted for 1 m, 0.7 m and 0.5 m length of the CFTs. The main effect is the direct effect of parameters on the response or dependent variable.Figs. 1–6show the main effect plots of parameters with respect to the ultimate axial load and associated axial shortening for CFT columns. It is plotted by considering the means of the responses at each level of the parameters, as shown inTables 6and7. FromFigs. 1,3and5, it can be noted that increases in diameter, wall thickness and strength of concrete will increase the ultimate axial load capacity for 1 m, 0.7 m and 0.5 m length of CFTs. However, the diameter of the steel tube has the most significant effect on both the ultimate axial load capacity and corresponding axial shortening of all the three lengths of the CFTs. The strength of the in-fill concrete and the wall thickness have respectively lesser effects compared to diameter of the steel tube. After the diameter, the wall thickness has the most influence on the ultimate axial load carrying capacity of CFTs 0.5 m in length. These CFTs act as short columns and an increase in wall thickness helps to postpone the local buckling failure. To assess the rank of each parameter, the deltas of the means of each level of all the factors are calculated and shown inTables 6and7. The Delta means the value of the maximum mean minus the minimum one.

The most influential factor ranks first.

(4)

Table 4

Theoretical and experimental density of CFTs-1 m long.

Notation Cross sectional area of CFT (mm2) Mass of CFT (gm) ρexp(kN/m3) Vfs Vfc ρtheo(kN/m3) ρexptheo

D1t1M30

1551.99

4435.00 28.58 0.11 0.89 30.85 0.93

D1t2M30 4783.00 30.82 0.14 0.86 32.43 0.95

D1t3M30 5061.67 32.61 0.17 0.83 34.20 0.95

D1t1M40 4452.67 28.69 0.11 0.89 30.85 0.93

D1t2M40 4800.33 30.93 0.14 0.86 32.43 0.95

D1t3M40 5098.00 32.85 0.17 0.83 34.20 0.96

D1t1M50 4534.00 29.21 0.11 0.89 30.85 0.95

D1t2M50 4815.33 31.03 0.14 0.86 32.43 0.96

D1t3M50 5081.33 32.74 0.17 0.83 34.20 0.96

D2t1M30

2565.54

7146.00 27.85 0.09 0.91 29.58 0.94

D2t2M30 7335.67 28.59 0.11 0.89 30.82 0.93

D2t3M30 7816.33 30.47 0.14 0.86 32.23 0.95

D2t1M40 7159.33 27.91 0.09 0.91 29.58 0.94

D2t2M40 7519.30 29.31 0.11 0.89 30.82 0.95

D2t3M40 7911.33 30.84 0.14 0.86 32.23 0.96

D2t1M50 7132.67 27.80 0.09 0.91 29.58 0.94

D2t2M50 7439.67 29.00 0.11 0.89 30.82 0.94

D2t3M50 7983.00 31.12 0.14 0.86 32.23 0.97

D3t1M30

3167.33

8716.00 27.52 0.08 0.92 29.13 0.94

D3t2M30 9213.33 29.09 0.10 0.90 30.26 0.96

D3t3M30 9484.00 29.94 0.12 0.88 31.53 0.95

D3t1M40 8786.70 27.74 0.08 0.92 29.13 0.95

D3t2M40 9201.33 29.05 0.10 0.90 30.26 0.96

D3t3M40 9581.00 30.25 0.12 0.88 31.53 0.96

D3t1M50 8658.67 27.34 0.08 0.92 29.13 0.94

D3t2M50 9224.00 29.12 0.10 0.90 30.26 0.96

D3t3M50 9515.67 30.04 0.12 0.88 31.53 0.95

Fig. 1. Main effects plot for the ultimate axial load for 1 m long CFTs.

Table 5

L9 – Orthogonal array adopted and experimental results – for each length of CFT.

Notation Ultimate axial loadPue(kN) Axial shortening at ultimate pointδue(mm)

1 m 0.7 m 0.5 m 1 m 0.7 m 0.5 m

D1t1M30 45.2 82 96.2 4.0 4.7 5.4

D1t2M40 86.5 117.1 134.1 4.1 5.0 5.2

D1t3M50 124 145.3 155.6 4.2 5.3 5.4

D2t1M40 151.6 176.5 187.5 6.0 6.3 5.6

D2t2M50 181.7 201.5 229 5.4 6.1 5.3

D2t3M30 144.3 205.8 213.7 8.4 7 7.3

D3t1M50 181.2 239.1 262.4 4.7 5.8 6.4

D3t2M30 185.6 226.3 230.5 7.4 7.6 7.8

D3t3M40 231.3 269 280.5 7.1 7.2 7.4

The experimental results are also analyzed using the Analysis Of Variance (ANOVA) technique. ANOVA is a statistical analysis which

helps to reduce the error variance and quantifies the dominance of a control factor. This analysis aids in justifying the effects of input changes on the responses in an experiment. From ANOVA it is found that diameter of the steel tube has the most significant effect on both the ultimate axial load carrying capacity and the associated axial shortening for all the lengths of the CFTs, while the strength of the in-fill concrete and the wall thickness have respectively lesser influence on these responses. The greaterFvalue confirms that the diameter of the steel tube has the most influential effect among all factors on the responses of CFTs of all the three lengths. Typical ANOVA details for CFTs of 1 m length are shown inTables 8and9.

4.3. Verification of Taguchi’s method for CFTs

After conducting the initial nine experiments, linear regression models are developed Eqs.(1)–(6)to predict ultimate axial load

(5)

Fig. 2. Main effects plot for axial shortening at the ultimate load for 1m long CFTs.

Fig. 3. Main effects plot for the ultimate axial load for 0.7 m long CFTs.

and axial shortening at the ultimate point for each length of the CFT samples.

CFTs—1 mlong

Puc-N = −368+5.97D+53.7t+1.98fcu (1) δuc-N = −0.26+0.132D+2.22t−0.0963fcu. (2) CFTs—0.7 mlong

Puc-N = −339+6.75D+54.6t+1.27fcu (3) δuc-N =0.52+0.100D+1.19t−0.0367fcu. (4) CFTs—0.5 mlong

Puc-N = −341+6.73D+46.1t+1.87fcu (5) δuc-N =2.21+0.0922D+1.21t−0.0600fcu. (6) Puc-N = Predicted ultimate axial load based on initial nine experiments (kN)

δuc-N=Predicted axial shortening at ultimate load based on initial nine experiments (mm)

D=Outer diameter of the steel tube (mm)

t=Wall thickness of the steel tube (mm)

fcu=Cube compressive strength of concrete at 28 days (MPa) These models are used to predict the axial load carrying capacity and associated axial shortening at the ultimate point of all the other CFT samples used in the experimental programme. To verify the accuracy of such predictions of the load carrying capacity and corresponding axial shortening, actual axial compression tests are now conducted for remaining samples, and a comparison of experimental values is made with the predicted values. It is observed that the regression models based on nine experiments predict the ultimate axial load carrying capacity very well, and reasonably well for axial shortening at ultimate point, for all the three lengths of the CFTs. A plot of experimental values vs predicted (Puc-NvsPueandδuc-Nvsδue) values for each 1 m, 0.7 m and 0.5 m length of the CFTs are shown inFigs. 7–9.

Experimental investigations were carried out by Gupta et al.

[11] on circular concrete filled steel tubes subjected to axial compression. The steel tubes used in their study were of diameter 47.28 mm–112.56 mm and the lengths of the CFT were 340 mm.

(6)

Fig. 4. Main effects plot for axial shortening at the ultimate load for 0.7 m long CFTs.

Fig. 5. Main effects plot for the ultimate axial load for 0.5 m long CFTs.

63.50 57.15

44.45 7.0

6.5 6.0 5.5

1.60 2.00 1.25

60 51

41 7.0 6.5 6.0 5.5

Diameter (mm) Wall thickness (mm)

Cube strength (MPa)

Fig. 6. Main effects plot for axial shortening at the ultimate load for 0.5 m long CFTs.

(7)

40 90 140 190 240

2 4 6 8 10

40 90 140 190 240

10

2 4 6 8

Fig. 7. Predicted values of axial load and axial shortening at the ultimate point vs experimental results — Linear regression analysis (1 m).

50 100 150 200 250 300

4 5 6 7 8 9

8 6

50 150 250 350 4

Fig. 8. Predicted values of axial load and axial shortening at the ultimate point vs experimental results — Linear regression analysis (0.7 m).

4 5 6 7 8 9

4 5 6 7 8 9

50 150 250 350

50 150 250 350

Fig. 9. Predicted values of axial load and axial shortening at the ultimate point vs experimental results — Linear regression analysis (0.5 m).

Tests were performed using M30 andM40 grade concrete as in- fill for the steel tubes and the load carrying capacities of those

CFTs were in the range of 156 kN–770 kN. The test results ofM30 grade concrete of Gupta et al. [11] are combined with the test

(8)

Table 6

Response table for means of mean values of each level — ultimate axial load.

Level Length of the CFT—1.0 m Length of the CFT—0.7 m Length of the CFT—0.5 m

D(mm) t(mm) fcu(N/mm2) D(mm) t(mm) fcu(N/mm2) D(mm) t(mm) fcu(N/mm2)

1 85.23 126.00 125.03 114.80 165.90 171.40 128.60 182.00 180.10

2 159.20 151.27 156.47 194.60 181.60 187.5 210.1 197.90 200.70

3 199.37 166.53 162.30 244.80 206.70 195.3 257.80 216.60 215.70

Delta 114.13 40.53 37.27 130.00 40.80 23.9 129.2 34.6 35.5

Rank 1 2 3 1 2 3 1 3 2

Table 7

Response table for means of mean values of each level of three factors — axial shortening at ultimate point.

Level Length of the CFT—1.0 m Length of the CFT—0.7 m Length of the CFT—0.5 m

D(mm) t(mm) fcu(N/mm2) D(mm) t(mm) fcu(N/mm2) D(mm) t(mm) fcu(N/mm2)

1 4.10 4.90 6.60 5.00 5.60 6.43 5.33 5.80 6.83

2 6.60 5.63 5.73 6.46 6.23 6.16 6.06 6.10 6.06

3 6.40 6.56 4.76 6.86 6.50 5.73 7.20 6.70 5.70

Delta 2.50 1.66 1.83 1.86 0.90 0.70 1.86 0.90 1.13

Rank 1 3 2 1 2 3 1 3 2

Table 8

ANOVA table for the response – ultimate axial load – 1 m.

Source DF Sum of squares Adj MS F

Diameter 2 20 110.8 10 055.4 39.66

Thickness 2 2 514.4 1 257.2 4.96

Cube strength of the concrete 2 2 410.9 1 205.4 4.75

Error 2 507.1 253.6

Total 8 25 543.3

Table 9

ANOVA table for the response – axial shortening at ultimate point – 1 m.

Source DF Sum of squares Adj MS F

Diameter 2 11.5800 5.7900 56.03

Thickness 2 4.1867 2.0933 20.26

Cube strength of the concrete 2 5.0467 2.5233 24.42

Error 2 0.2067 0.1033

Total 8 21.0200

results of the present experimental investigations and a simple linear regression model is developed (Eq.(7)) to generalize the model for CFTs of diameter 44.45 mm–112.56 mm. To validate the model further, part of the experimental test results of Gupta et al. are used and the axial compressive strengths of CFTs with M40grade concrete were predicted using Eq.(7). It is found that the regression model so developed predicts the ultimate axial load carrying capacity of the CFTs very well. A plot of experimental values vs predicted values based on Eq.(7)is shown inFig. 10.

Puc-G= −176+6.88D+73.0t+1.93fcu−0.437L (7) Puc-G=Generalized regression model to predict the ultimate axial load (kN) for short columns.

4.4. Interaction models

Based on the test results of these twenty seven experiments performed for each length of the CFTs, regression models are also developed (Eqs.(8)–(13)) using the Response Surface Method (RSM), to account for the interaction between the test variables on the ultimate axial load carrying capacity and the corresponding axial shortening.

CFTs—1 mlong

Puc-R = −512.84+5.007D+97.365t+7.38fcu−0.010D2

−42.741t2−0.065fcu2+1.169D.t+0.005D.fcu

+0.691t.fcu (8)

Fig. 10. Predicted values of ultimate axial load using the generalized regression model vs experimental results [11].

δuc-R = −26.915+0.744D+1.958t+0.321fcu−0.0051D2

−0.0053t2−0.0031fcu2+0.0019D.t−0.0014D.fcu

−0.0047t.fcu. (9)

CFTs—0.7 mlong

Puc-R = −155.326+0.162D+61.844t+0.455fcu+0.036D2

−3.974t2+0.002fcu2+0.623D.t+0.030D.fcu

−0.440t.fcu (10) δuc-R = −12.676+0.449D+2.540t+0.077fcu−0.0018D2

0.4180t20.0004fcu20.0261D.t0.0021D.fcu

+0.0249t.fcu. (11)

CFTs—0.5 mlong

Puc-R = −88.651−3.606D+61.844t+0.455fcu+0.036D2

−3.974t2+0.002fcu2+0.623D.t+0.030D.fcu

−0.440t.fcu (12) δuc-R = −12.676+0.449D+2.540t+0.077fcu−0.0018D2

−0.4180t2−0.0004fcu2−0.0261D.t−0.0021D.fcu

+0.0249t.fcu (13)

Puc-R=Predicted ultimate axial load based on the Response Surface Method (kN)

(9)

40 90 140 190 240 290

40 90 140 190 240 290

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 9

Fig. 11. Predicted values of axial load and axial shortening at the ultimate point vs experimental results — Regression analysis based on the RSM (1.0 m).

Fig. 12. Predicted values of axial load and axial shortening at the ultimate point vs experimental results — Regression analysis based on the RSM (0.7 m).

Fig. 13. Predicted values of axial load and axial shortening at the ultimate point vs experimental results — Regression analysis based on the RSM (0.5 m).

(10)

Fig. 14. Surface plot of axial load at the ultimate point vs cube strength and wall thickness for CFTs — 1 m long.

δuc-R=Predicted axial shortening at the ultimate load based on the Response Surface Method (mm)

Using these regression models, the ultimate axial load and corresponding axial shortening of CFTs are predicted. A plot of actual experimental values vs predicted values for each 1 m, 0.7 m and 0.5 m length of the CFTs are shown inFigs. 11–13. It is found that, for all the three lengths of the CFTs, these interactions are more accurate for the prediction of ultimate axial load than for the axial shortening at the ultimate point.

4.5. Interaction plots

Typical response surface plots and contour plots for the ultimate axial load for both 1 m and 0.7 m lengths of the CFTs have been drawn using MINITAB (version 14). The response surface plots indicate the effect of any two variables together on the axial load capacity at the ultimate point. A typical response surface plot shown inFig. 14explains the effect of wall thickness and cube strength of in-fill concrete together on the axial load capacity at the ultimate point. Contour plots are useful to arrive at the proper combination of tube diameter, wall thickness and cube strength of

Fig. 15. Contour plot of axial load at the ultimate point vs. cube strength and wall thickness for CFTs — 0.7 m long.

60 58 56 54 52 50 48 46 44 42

62.5 60.0 57.5 55.0 52.5 50.0 47.5 45.0

Fig. 16. Contour plot of axial shortening at the ultimate point vs cube strength and diameter for CFTs — 0.7 m long.

(11)

60 58 56 54 52 50 48 46 44 42 2. 0 1. 9 1. 8 1. 7 1. 6 1. 5 1. 4 1. 3

Fig. 17. Overlaid contour plot of axial load and axial shortening at the ultimate point for CFTs — 1.0 m long (D=63.5 mm).

60 58 56 54 52 50 48 46 44 42 2. 0 1. 9 1. 8 1. 7 1. 6 1. 5 1. 4 1. 3

Fig. 18. Overlaid contour plot of axial load and axial shortening at the ultimate point for CFTs — 0.7 m long (D=63.5 mm).

in-fill concrete for given values of axial load or axial shortening at the ultimate point of the CFTs. Typical contour plots for axial load and axial shortening of 0.7 m long CFTs are shown inFig. 15and Fig. 16respectively. The overlaid contour plots are useful to choose a combination of any two of the variables amongst diameter, wall thickness and cube strength of in-fill concrete for a certain range of design axial load capacity and the corresponding axial shortening. A set of overlaid contour plots shown inFigs. 17–19.

Fig. 17demonstrates the combination of cube strength of in-fill concrete and wall thickness for the axial load capacity in the range 200–220 kN and the corresponding axial shortening in the range 6.0–6.7 mm for the CFT of 1 m long and 63.5 mm diameter.

SimilarlyFigs. 18and19shows the combination of cube strength of in-fill concrete and wall thickness for the axial load capacity in the range 240–260 kN and the corresponding axial shortening in the range 6.6–7.0 mm and 7.0–7.5 mm for the CFTs of 0.7m and 0.5 m length, respectively.

4.6. Comparison of experimental results with EC4 and AISC-LRFD specifications

The results obtained in the present experimental work were compared with the predictions based on EC4-1994 [22] and AISC- LRFD-2005 [24] code provisions. EC4 uses the limit state concept to achieve the aims of serviceability and safety, by applying a partial safety factor to the load and material properties. When calculating predicted values from the codes, all the partial safety factors are taken as unity. Comparisons of the experimental ultimate load of test specimens with predictions based on code provisions for three lengths of CFTs are shown inTables 10and11. When the relative slendernessλ(as defined in Equation 6.39 of EC4-1994) is greater than 0.5 the confinement effect is minimum. However, the composite action can be improved to some extent by choosing an appropriate combination of the strength of steel and the strength of concrete. Here an attempt is made to study the effect of changing λon the axial load capacities of short and long columns (Table 11).

(12)

Fig. 19. Overlaid contour plot of axial load and axial shortening at the ultimate point for CFTs — 0.5 m long (D=63.5 mm).

Table 10

Comparison of experimental results with AISC Codes.

Notation 1 m 0.7 m 0.5 m

Pue(kN) PAISC(kN) Pue/PAISC Pue(kN) PAISC(kN) Pue/PAISC Pue(kN) PAISC(kN) Pue/PAISC

D1t1M30 45.20 79.78 0.57 82.00 82.51 0.99 96.20 83.83 1.15

D1t2M30 69.40 88.34 0.79 96.50 91.79 1.05 117.20 93.47 1.25

D1t3M30 82.00 97.71 0.84 127.10 102.09 1.24 132.70 104.22 1.27

D1t1M40 68.60 90.49 0.76 94.00 93.66 1.00 114.70 95.19 1.20

D1t2M40 86.50 98.64 0.88 117.10 102.55 1.14 134.10 104.45 1.28

D1t3M40 104.80 107.58 0.97 138.00 112.42 1.23 148.40 114.77 1.29

D1t1M50 85.40 101.10 0.84 109.90 104.76 1.05 120.30 106.52 1.13

D1t2M50 101.00 108.85 0.93 130.00 113.25 1.15 141.70 115.38 1.23

D1t3M50 124.00 117.34 1.06 145.30 122.68 1.18 155.60 125.27 1.24

D2t1M30 119.80 123.07 0.97 163.00 125.33 1.30 171.70 126.40 1.36

D2t2M30 135.00 135.12 1.00 181.60 137.89 1.32 188.50 139.22 1.35

D2t3M30 144.30 148.54 0.97 205.80 151.98 1.35 213.70 153.62 1.39

D1t1M40 151.60 141.88 1.07 176.50 144.57 1.22 187.50 145.86 1.29

D2t2M40 173.10 153.40 1.13 192.10 156.63 1.23 206.30 158.17 1.30

D2t3M40 188.30 166.24 1.13 221.90 170.14 1.30 239.30 172.00 1.39

D2t1M50 162.00 160.58 1.01 187.20 163.75 1.14 200.30 165.26 1.21

D2t2M50 181.70 171.57 1.06 201.50 175.29 1.15 229.00 177.06 1.29

D2t3M50 206.10 183.82 1.12 231.30 188.22 1.23 256.00 190.33 1.35

D3t1M30 150.50 146.86 1.02 191.30 149.27 1.28 211.70 150.42 1.41

D3t2M30 185.60 161.16 1.15 226.30 163.73 1.38 230.50 164.95 1.40

D3t3M30 202.30 177.23 1.14 243.60 180.01 1.35 255.00 181.34 1.41

D3t1M40 169.30 170.37 0.99 208.00 173.29 1.20 241.60 174.69 1.38

D3t2M40 210.50 184.22 1.14 240.80 187.25 1.29 264.10 188.69 1.40

D3t3M40 231.30 199.76 1.16 269.00 202.95 1.33 280.50 204.46 1.37

D3t1M50 181.20 193.75 0.94 239.10 197.22 1.21 262.40 198.88 1.32

D3t2M50 226.70 207.16 1.09 262.00 210.68 1.24 283.00 212.35 1.33

D3t3M50 240.60 222.17 1.08 280.20 225.80 1.24 294.60 227.53 1.29

The comparison of results indicates that the predicted ultimate load carrying capacity for 1 m long CFTs from both the codes is much higher compared to the experimental values. However, for 0.5 m and 0.7 m long CFTs the predictions of ultimate load by the codes are fairly good.

5. Conclusions

Results of experimental investigations on circular CFT samples with D/t ratio of 22.3–50.8 and L/D ratio of 7.8–22.5 have been presented in this paper. From the experimental results, the following broad conclusions can be drawn.

1. Regression models developed with a minimum number of experiments based on the Taguchi method predict the axial

load carrying capacity very well and the axial shortening at the ultimate point reasonably well.

2. The diameter of the steel tube has the most significant effect on both the ultimate axial load and the corresponding axial shortening of the CFTs.

3. Regression models developed using the Response Surface Method for the ultimate axial load and the corresponding axial shortening account for the interaction between the test variables.

4. The larger variation for slender CFTs between the experimental values and the values predicted from the codes indicates that more studies are needed and the codal provisions should be refined.

Referensi

Dokumen terkait

Chandrashekarad, Aruna Jampania aDepartment of Biotechnology, REVA University, Bengaluru, India bDepartment of Mechanical Engineering, Indian Institute of Science, Bengaluru, India

Nethajid aDepartment of Chemistry, National Institute of Technology, Rourkela 769008, Odisha, India bDepartment of Chemistry, Indian Institute of Technology Roorkee, Roorkee 247667,

Ragounadin Department of Civil Engineering, National Institute of Technology Karnataka, Srinivasnagar, Karnataka 575 025, India Abstract Analytical formulations and solutions to the

Adhikaric aDepartment of Physics, Manipal Institute of Technology, Manipal University, Manipal, Udupi, Karnataka 576104, India bDepartment of Physics, National Institute of Technology

Ashok Babu Professor Department of Mechanical Engineering NITK, Surathkal Post Srinivasnagar, Mangalore 575 025, Karnataka, India Ammonia-Water Mixture Visualization of bubble

Omkara,n, Akshay Venkateshb, Mrunmaya Mudigerea aDepartment of Aerospace Engineering, Indian Institute of Science, Bangalore-560012, India bNational Institute of Technology Karnataka,

Adhikarib, Mandela Govinda Raja aNational Institute of Technology Karnataka, Surathkal, Mangalore, Karnataka 575025, India bNational Institute of Rock Mechanics, Kolar, India a r t i