X
Courses » Design of Photovoltaic Systems
Unit 3 -
WEEK-02: SERIES AND PARALLEL INTERCONNECTION
Announcements Course Ask a Question Progress Mentor FAQ
Course outline
WEEK-00:
Getting Started
WEEK-01: THE PV CELL
WEEK-02:
SERIES AND PARALLEL
INTERCONNECTION Identical cells in series Load line Non-identical cells in series Protecting cells in series Interconnecting modules in series Simulation of cells in series Identical cells in parallel Non-identical cells in parallel Protecting cells in parallel Interconnecting modules Simulation of cells in parallel Practicals - Measuring I-V characteristics Practicals - PV
Due on 2018-08-15, 23:59 IST.
1) 1 point
2) 1 point
WEEK 02 - Assessment
The due date for submitting this assignment has passed.
As per our records you have not submitted this assignment.
Few photovoltaic modules are connected in series-parallel configuration as shown in the figure below. Each module has an I-V characteristic having the x-axis intercept as 31V and the y-axis intercept as 4.2A. The short circuit current for the series-parallel system shown is
Fig.1
4.2 A 8.4 A 12.6 A 25.2 A
No, the answer is incorrect.
Score: 0
Accepted Answers:
8.4 A
A project of In association with
Funded by
© 2014 NPTEL - Privacy & Terms - Honor Code - FAQs -
Design of Photovoltaic Systems - - Unit 3 - WEE... https://onlinecourses.nptel.ac.in/noc18_ee35/un...
1 of 4 Thursday 08 November 2018 04:01 PM
Powered by
Week 03:
ENERGY FROM SUN
Week 04:
INCIDENT ENERGY ESTIMATION
Week 05: SIZING PV
Week 06:
MAXIMUM POWER POINT TRACKING
Week 07: MPPT ALGORITHMS
Week 08:
PV-BATTERY INTERFACES
Week 09:
PELTIER COOLING
Week 10: PV AND WATER PUMPING
WEEK-11:
PV-GRID INTERFACE-I
Week 12:
INTERFACE-II and LIFE CYCLE COSTING
source emulation WEEK-02 Resources Quiz : WEEK 02 - Assessment Week 02 Assessment solutions
3) 1 point
4) 1 point
5) 1 point
For the photovoltaic module configuration shown in Figure.1, the open circuit voltage for the series-parallel system is
93 V 31 V 62 V 186 V
No, the answer is incorrect.
Score: 0
Accepted Answers:
93 V
V1 and V2 are two voltage sources having voltages 11V and 13V respectively. The series resistance of each source is 0.25 ohms.
The circulating current is
Fig. 2
8 A 4 A 2 A 24 A
No, the answer is incorrect.
Score: 0
Accepted Answers:
4 A
With reference to the circuit topology shown in Figure.2, in
order to eliminate the circulating currents for any values of V1 and V2, one can use diode along the path of the source current flow such that
a diode is in series with the voltage source V1
a diode is in series with the voltage source V2
a diode is in series with either of the voltage sources V1 or V2
diodes are in series with both the voltage sources
No, the answer is incorrect.
Score: 0
Accepted Answers:
diodes are in series with both the voltage sources
A photovoltaic panel has four modules connected in series, each module having an open-circuit voltage (Voc ) of 10V and short- circuit current (Isc ) of 2A. What should be the voltage axis intercept of the I-V characteristics of the series system?
10 V
Design of Photovoltaic Systems - - Unit 3 - WEE... https://onlinecourses.nptel.ac.in/noc18_ee35/un...
2 of 4 Thursday 08 November 2018 04:01 PM
6) 1 point
7) 1 point
8) 1 point
8 V 40 V 80 V
No, the answer is incorrect.
Score: 0
Accepted Answers:
40 V
A photovoltaic panel has four modules connected in series, each module having an open-circuit voltage (Voc ) of 10V and short- circuit current (Isc ) of 2A. What should be the current axis intercept of the I-V characteristics of the series system?
2 A 8 A 4 A 0.5 A
No, the answer is incorrect.
Score: 0
Accepted Answers:
2 A
Two dissimilar PV cells are connected in parallel (no
protection diodes are incorporated). Let the open-circuit voltage and short-circuit current of one cell be 10V and 2A respectively. Let the open-circuit voltage and short-circuit current of the other cell be 12V and 3A respectively. If Voc and Isc represent the open-circuit voltage and short-circuit current of parallel cell combination, then
Voc < 10V Voc >12V Voc = 10V 10V<Voc<12V
No, the answer is incorrect.
Score: 0
Accepted Answers:
10V<Voc<12V
A PV module has 20 cells connected in series. There are no
protection diodes. Each cell has a Voc of 1V and Isc of 2A. One cell is completely shaded. Across the shaded cell, instead of a bypass diode, a resistor of 10 ohms is connected. The Voc of the PV module is
19 V 20 V 0 V 18 V
No, the answer is incorrect.
Score: 0
Design of Photovoltaic Systems - - Unit 3 - WEE... https://onlinecourses.nptel.ac.in/noc18_ee35/un...
3 of 4 Thursday 08 November 2018 04:01 PM
9) 1 point
10) 1 point
Accepted Answers:
19 V
A battery having a voltage of 48V is in series with a 10 ohm resistance. Across the terminals of this series system, a load Ro is connected. Maximum power is transferred to Ro when
10 ohms 20 ohms 5 ohms 24 ohms
No, the answer is incorrect.
Score: 0
Accepted Answers:
10 ohms
A battery having a voltage of 48V is in series with a 10 ohm resistance. Across the terminals of this series system, a load Ro is connected. Maximum power that can be transferred to Ro is
51.2 W 230 W 43.2 W 57.6 W
No, the answer is incorrect.
Score: 0
Accepted Answers:
57.6 W
Previous Page End
Design of Photovoltaic Systems - - Unit 3 - WEE... https://onlinecourses.nptel.ac.in/noc18_ee35/un...
4 of 4 Thursday 08 November 2018 04:01 PM