• Tidak ada hasil yang ditemukan

Effect of Water Storage on the Micro-shear Bond Strength of Two Self-etch Adhesives to Enamel and Dentin

N/A
N/A
Protected

Academic year: 2024

Membagikan "Effect of Water Storage on the Micro-shear Bond Strength of Two Self-etch Adhesives to Enamel and Dentin"

Copied!
5
0
0

Teks penuh

(1)

Effect of Water Storage on the Micro-shear Bond Strength of Two Self-etch Adhesives to Enamel and Dentin

Z. Jaberi Ansari 1~, AR. Sadr 2

1Assistant Professor, Department of Operative Dentistry, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran

2Postgraduate Student, Department of Cariology and Operative Dentistry, Tokyo Medical and Dental University, Tokyo, Japan

Abstract:

Objective: This study evaluated the influence of storage time on micro-shear bond strength of two self-etching materials to enamel and dentin.

Materials and Methods: Human third molar teeth were sectioned to 1.5 mm thick beams and randomly divided into 2 groups. In group I, SE Bond and in group II, Tri-S Bond was used to bond a composite rod (AP-X) to each treated surface. Specimens were prepared according to manufacturer instructions. Each group was further divided into three subgroups according to water storage time; 1 day, 6 and 12 months. Micro- shear bond strengths were determined under a crosshead speed of 1mm/min using a universal testing machine and expressed in MPa. Data was statistically analyzed by ANOVA and Dunnett post hoc test.

Results: Micro-shear bond strength of two adhesives to enamel and dentin showed a slight but not significant decrease over time (P>0.5). After one day, the mean bond strength of enamel in groups I and II were 39.47 and 34.65 MPa and in dentin were 45.20 and 36.0 MPa respectively. There was no statistically significant difference between two materials (P=0.190, P=0.082). After six months the bond strength in group I and II was 35.93 and 35.18 MPa for enamel, and 38.27and 35.19 MPa for dentin respectively, these differences was not statistically significant (P=0.520, P=0.179).

After one year, the bond strength of enamel in groups I and II, were 34.47and 29.91 MPa, and in dentin were 33.86 and 32.53 MPa respectively which was not statistically significant (P=0.609, P=0.991).

Conclusion: The micro-shear bond strength of both adhesives to enamel and dentin decreased slightly over time; however these decreases were not statistically significant.

Key Words: Self etch adhesive; Durability; Micro-shear bond strength; Enamel; Dentin

Journal of Dentistry, Tehran University of Medical Sciences, Tehran, Iran (2007; Vol: 4, No.2)

INTRODUCTION

In the past two decades, the traditional mecha- nical retention methods for restorative materi- als have been replaced by tooth-conserving adhesive methods. The ultimate goal of a dental bonding system is to achieve a durable bond between restorative materials and enamel or dentin [1]. In the past decade, many dental adhesives have been commercialized with the

aim of increasing the bonding efficacy and simplifying the bonding process. The dura- bility of these bonds between adhesive resins and tooth structures are of critical importance for the longevity of bonded restorations. Most of the currently marketed adhesive resins achieve high bond strength immediately after polymerization of resin. The longevity of this bond is an important criterion to determine

~ Corresponding author:

Z. Jaberi Ansari, Department of Operative Dentistry, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

[email protected] Received: 6 August 2006 Accepted: 6 December 2006

(2)

their effectiveness; and adhesive bonds durabi- lity is one of the areas of current interest in adhesive dentistry. Several studies demonstra- ted a decrease in bond strength after one year water storage [2-4], some others reported no significant changes [5,6]; however in one study an increase in bond strength was observ- ed [7].

The aim of this study was to evaluate the influ- ence of water storage on micro-shear bond strength of two self-etching adhesive system to enamel and dentin.

MATERIALS AND METHODS

In this experimental study, two self-etching adhesive systems were evaluated. Details of composite resin and two adhesive systems used in present study are listed in Table I.

For evaluating the micro-shear bond strength, extracted human third molars were selected and stored in normal saline solution. After cleaning and disinfection by 0.05% thymol solution, teeth were sectioned (mesiodistally) to 1.5 mm thick slices with a low speed dia- mond saw (Buehler Ltd, Lake Bluff, IL), these slices were ground flat with 600-grit silicon carbide sandpapers under water coolant. All specimens were randomly divided into two groups; in group I (n=30), Clearfil SE Bond (CSEB) was applied, and the specimens in group II (n=30) were treated with Clearfil Tri S Bond (CTSB) according to the manufac- turer’s instruction.

Clearfil AP-X resin composite was bonded to the treated surfaces using hollow Tygon tubes

(0.75×1mm, Tygon, Norton performance Plastic, Co. Cleveland, OH, USA) to make a cylinder, and was light cured for 40 seconds.

All specimens were stored in water at 37°C, and were further divided into three subgroups according to the water storage time: 24 hours, 6 and 12 months storage for subgroups 1, 2 and 3 respectively. Teeth in each group were evaluated under a stereomicroscope (Olympus, Tokyo, Japan) for possible defects. Specimens which showed apparent defects were excluded and were substituted to ensure of 10 specimens in each group.

The micro-shear bond strength values for each group were determined using a universal testing machine (EZ-test 500N, Shimazu CO, Kyoto, Japan) at a crosshead speed of 1mm/min. The maximum load at the time of failure was reported as Newton, and then bond strength was calculated in MPa.

All the fractured surfaces were examined under a stereomicroscope (Olympus, Tokyo, Japan) at ×30 magnifications to determine the mode of failure, and were classified as adhesive, cohesive and mixed failures.

Collected data were statistically analyzed by two-way and one-way ANOVA and Dunnett post hoc test.

RESULTS

Descriptive statistics of micro-shear bond strength of each adhesive group to enamel and dentin after 24 hours, 6 months, and one year are summarized in Table II.

The results of the study showed that mean

Table I: The Materials used in this study.

Materials Manufacture Compositions

Clearfil SE Bond Kuraray Medical Inc., Tokyo, Japan

Hydrophilic dimethacrylate, N, N-diethanol P-toluidine, di- Camphorquinone, N, N-diethanol P-toluidine, silanted colloidal Silica, MDP(10-methacryioxydecyl dihydrogen phosphate), HEMA

Clearfil Tri - S Bond Kuraray Medical Inc., Tokyo, Japan

Water, MDP, Bis-GMA, HEMA, hydrophobic, dimetha- crylate, di-Camphorquinone, Ethanol, Water, Silanated, Colloidal silica.

Clearfil AP-X Kuraray Medical Inc.,

Tokyo, Japan hybrid Light-curing Composite

(3)

bond strength of two adhesives to enamel and dentin has a slight but not significant decrease over time (P>0.5).

Although after one day water storage, the mean bond strength for enamel and dentin in group I was more than that in group II, the difference was not statistically significant (P=0.190, and P=0.082 for enamel and dentin respectively).

After 6 months, the micro-shear bond strength for enamel and dentin in group I was more than group II, however these differences was not statistically significant (P=0.529, and P=0.179 respectively).

Micro-shear bond strength measurement after one year water storage for enamel and dentin showed higher values for group I. These differences was not statistically significant between the two groups (P=0.609, and P=0.991 respectively).

The fracture modes are presented in Table III and included adhesive, cohesive and mixed failures. The failure modes for CSEB speci- mens included all three patterns. In the CTSB group the fracture mode was mostly adhesive failure. Comparison of the failure mode of the two adhesives systems in enamel and dentin shows that this difference was statistically significant (P<0.036, and P<0.001 respective- ly).

DISCUSSION

The purpose of this study was to evaluate the

Table II: Mean and standard deviation (values in parentheses) of shear bond strength (MPa) of two adhesive systems.

CSEB CTSB Enamel Dentin Enamel Dentin 24h ours 39.47

(5.34)

45.20 (10.36)

34.65 (5.65)

36.0 (6.13) 6 Months 35.93

(7.13)

43.17 (11.19)

35.18 (9.20)

35.19 (5.9) One year 34.47

(8.44)

33.86 (11.62)

29.91 (7.78)

32.53 (10.73)

micro-shear bond strength of two self-etch adhesives to enamel and dentin after storing in water for one-day, 6-months and one-year.

Clearfil SE Bond is a mild two-step self- etching adhesive (pH=2). In this system colla- gen fibrils are not completely deprived of hydroxyapatite. This residual hydroxyapatite may then chemically interact with specific carboxyl or phosphate groups of functional monomers [1,8]. Theses monomers may be able to interact more intimately with hydroxy- apatite-coated collagen that otherwise would have almost completely lost its hydroxyapatite coating with a rather aggressive total-etching technique [6,8,9]. Clearfil Tri-S Bond is a new product. It is one-step self-etching adhesive, which is made for simplifying the procedure and lessen the application time.

The micro-shear bond strength test was chosen due to its advantages compared to other bond strength evaluation methods and its relative easiness of sample preparation and suitability for enamel bonding tests [10-12].

Results of the present study showed that mean bond strength of two adhesives to enamel and dentin has a slight but not significant decrease over time, which was similar to other studies [13-15].

The application of a self-etching primer on enamel results in a shallow etching pattern.

This might be due to the mild decalcification effect of self-etching primer or the etching might decrease gradually as a result of neutral-

Table III: Modes of failure of two adhesive systems after 24 hours, six months and one year water storage (A=adhesive, C=cohesive and M=mixed failures).

Enamel Dentin

Material A C M A C M

24 hours 4 3 3 7 2 1

6 Months 2 4 4 3 2 5

CSEB

One year 4 4 2 4 1 5

24 hours 7 1 2 9 0 1

6 Months 5 3 2 8 0 2

CTSB

One year 7 3 0 10 0 0

(4)

lization of the acidity of primer on the enamel surface [16-18], or it may be a result of selec- tive decalcification of the interprismatic region due to weak acidity of self-etching primer [18]. Decrease in bond strength in ena-mel after one year storage could also be due to formation of shallow resin tags [16]. In addi- tion, water diffusion into the bonding interface may result in composite resin swelling and plasticizing of the resin [16].

The primer agent of the CSEB system includes a hydrophilic acidic monomer of MDP as the functional monomer, HEMA, DMA, and photo initiator dl-camphorquinone, while the bon- ding agent contains filler and bis-GMA in addition to primer ingredients, except for the water. The all-in-one system, CTSB contains all the aforementioned components in a single bottle. Acidic monomers are the main ingre- dients of the self-etching primer systems and besides participating in the polymer network, have various functions which contribute to the bonding performance to the dentin and enamel substrates [1,19].

The etching effects of both systems used in the present study are due to the acidic effect of the water-MDP solution. MDP is also responsible for the dentin priming through wetting the dentinal collagen network via infiltration into the dentin [19]. Moreover, MDP has been reported to chemically interact with the hyd- roxyapatite and form low soluble calcium salts [19]. Many researchers have studied the hyd- rolytic stability of acidic monomers. In acidic methacrylate phosphate MEP (methac-ryloxy ethyl dihydrogen phosphate), both the methac- rylate and phosphate ester bonds were hydro- lyzed and resulted in the formation of metha- crylic acid (MAA), phosphoric acid or other derivatives. The phosphate ester bond in MDP was found to be significantly more stable than MEP that has a shorter alkylene spacer [19].

Salz et al [19] observed a significant reduction in the concentration of the MDP in an aqueous solution after 16 weeks of storage at 37 °C.

The results of present study is also in agree- ment with the results of studies conducted by Sano et al [2], Okuda et al [5], and, Steven et al [7], which showed a decrease in bond strength of self-etch adhesives after long-term storage. Most of which hypothesized that a decrease in bond strength over long period of time is due to hydrolytic degradation of ester bonds of polymerized resin within the hybrid layer which gradually increase as water dif- fused through nano-leakage channels which become larger over the time, resulting in lower bond strengths and interfacial failure [5].

Fracture modes results showed that the mode of failure for CSEB specimens included all three various patterns. The fracture modes in CTSB specimens were mainly classified as adhesive failure, especially in dentin substrate which all specimens showed adhesive failure over one year water storage. The results are in agreement with Wang et al [16] that the fracture toughness of adhesive may decrease.

CONCLUSION

Within the limitations of this study, it was concluded that although the micro-shear bond strength of both adhesives to enamel and dentin seems to decrease slightly within time, the difference was not statistically significant.

ACKNOWLEDGMENT

Authors wish to express their gratitude to Dr.

Moezizadeh, Dr. Aminian, and Dr. Moayedi.

REFERENCES

1- Summitt JB, Robbins JW, Hilton TJ, Schwartz RS. Fundamentals of operative dentistry.3rd ed.

Chicago: Quintessence pub; 2006. p. 202-42.

2- Sano H, Yoshikawa T, Pereira PNR, Kanemura N, Tagami J, Pashley DH. Long-term durability of dentin bonds made with a self-etching primer, in vivo. J Dent Res 1999; 78(4): 906-11.

3- Carrilho MR, Carvalho RM, Tay FR, Yiu C, Pashley DH. Durability of resin-dentin bonds related to water and oil storage. Am J Dent 2005:

(5)

18(6):315-9.

4- Toledano M, Osorio R, Osorio E, Aguilera FS, Yamauti M, Pashley DH, Tay F. Effects of direct/indirect exposure and storage media. Dent Mater 2007;23(7):885-92.

5- Okuda M, Pereira PN. Nakajima M, Tagami J, Pashley DH. Long-term durability of resin dentin interface: nanoleakage vs. microtensile bond stren- gth. Oper Dent 2002; 27:289-96.

6- Inoue S, Koshiro K, Yoshida Y, De Munck J, Nagakane K, Suzuki K. Hydrolytic stability of self-etch adhesives bonded to dentin. J Dent Res 2005;84:1160-4.

7- Armstrong SR, Vargas MA, Fang Q, Laffoon JE. Micro tensile bond strength of a total-etch 3- step, total-etch 2-step, self-etch 2-step, and a self- etch 1-step dentin bonding system through 15- month water storage. J Adhes Dent 2003;5(1):47- 56.

8- Yazici AR, Akca T, Ozgünaltay G, Dayangaç B.

Bond strength of a self-etching adhesive system to caries-affected dentin, Oper Dent 2004,29(2):176- 81.

9- Nishiyama N, Suzuki K, Yoshida H, Teshima H, Nemoto K. Hydrolytic stability of metha- crylamide in acidic aqueous solution. Biomaterials 2004;25(6):965-9.

10- Shimada Y, Yamaguchi S, Tagami J. Micro- shear bond strength of dual-cured resin cement to glass ceramics. Dent Mater 2002;18:380-8.

11- Ogata M, Nakajima M, Sano H, Tagami J.

Effect of dentin primer application on regional

bond strength to cervical wedge-shaped cavity walls. Oper Dent 1999; 24(2):81-8.

12- Burrow MF, Nopnakeepong U, Phrukkanon S.

A comparison of micro-tensile bond strengths of several dentin bonding systems to primary and permanent dentin. Dent Mater 2002; May18(3):

239-45.

13- Okuda M, Pereira PN, Nakajima M, Tagami J.

Relationship between nanoleakage and long-term durability of dentin bonds. Oper Dent 2001;

26(5):482-90.

14- Brandt PD, de Wet FA, du Preez IC. Self- etching bonding systems: in-vitro shear bond strength evaluation. SADJ 2006;61(1):7-16.

15- Shirai K, De Munck J, Yoshida Y, Inoue S, Lambrechts P, Suzuki K, Shintani H, Van Meerbeek B. Effect of cavity configuration and aging on the bonding effectiveness of six adhesives to dentin. Dent Mater 2005;21(2):110-24.

16- Wang H, Shimada Y, Tagami J. Shear bond stability of current adhesive systems to enamel.

Oper Dent 2004;29(2):168-75.

17- Pashley DH, Carvalho RM. Dentin permeabi- lity and dentin adhesion. J Dent 1997;25(5)355-72.

18- Torii Y, Itou K, Hikasa R, Iwata S, Nishitani Y. Enamel tensile bond strength and morphology of resin-enamel interface created by acid etching system with or without moisture and self-etching priming system. J Oral Rehabil 2002;29(6):528-33.

19- Salz U, Zimmermann J, Zeuner F, Moszner N.

Hydrolytic stability of self-etching adhesive sys- tems. J Adhes Dent 2005;7:107-16.

Referensi

Dokumen terkait

Sahebi Department of Health in Disasters and Emergencies, School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran Tel: +98 2122432040-1, Fax:

Pazandeh Department of Midwifery and Reproductive Health, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran Tel: +98 21 88202512, Fax: +98

Alhuthaifi Department of Cardiology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran Tel: +98 912 1140287, Fax: +98 21 42910703, E-mail address:

EBRAHIMIAN* *Department of Pharmaceutics, **Department of Medicinal Chemistry, Faculty of Pharmacy, Shaheed Beheshti University of Medical Sciences, Tehran, Iran ABSTRACT The

*Anesthesiologist, Department of Operating Room, Shahid Beheshti Hospital, Yasuj University of Medical Sciences, Yasuj, Iran **Neurosurgen, Department of Neurosurgery, Shahid

Adimi Department of Pulmonary and Sleep Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran Tel: +98 21 27122408-9, Fax: +98 21 26109490, E-mail address:

Fanak Fahimi 1,2 , Fatemeh Soleymani 3,4, Maria Tavakoli-Ardakani 1,5* 1 Clinical Pharmacy Department, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Nekooghadam Internal Department of Shohadaye Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran Tel: +98 2125719, Fax: +98 2125719, E-mail addresses: