Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]The AID EliSpot/FluoroSpot Reader portfolio and their features
08/12/2010, Vetereans General Hospital, Taichung, Taiwan
Juergen Haeussler AID GmbH, Germany
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Part 1: How it works
Part 2: EliSpot in diagnostics
Part 3: Limitations of EliSpot and Development of FluoroSpot
Part 4: The AID EliSpot/FluoroSpot Reader portfolio
Part 5: Live-Demo of the AID iSpot Reader
世翔國際有限公司Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Part 1: How it works
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Measuring antigen specific T-cell reactions
Enzyme-linked ImmunoSpot assay: Method to detect cytokine release of T-cells on the single cell level. EliSpot
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Lymphocyte-isolation (FICOLL)
Y Y
Y Y
Y Y Y
Y Y
Usually Elispot Assays are performed in a 96well plate with a membrane bottom in each well. The membrane is precoated with capture antibody specific for a cytokine (e.g. IFN-γ)
Add cells together with antigen (mitogen) and incubate for 16-20h at 37°C.
Some cells will be stimulated to produce cytokine molecules, which are bound to the membrane by the capture antibody.
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Y
Remove cells, add detection AB, conjugated with substrate-specific enzyme.
Add substate and perform enzyme-substrat reaction to visualize developing spots.
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Extremely sensitive
Close to the in vivo-situation
Analyses secreted cytokines (post-translational regulation)
Easy to perform
Results within 16 hours
Allows monitoring of TH 1 /TH 2 balance
High throughput assays (96-well format)
Well suited for screening and standardization
Disadvantages
Only one cytokine can be analysed
Reader is needed
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]0 200 400 600 800 1000 1200 1400 1600
1983 - 1985 1986 - 1990 1991 - 1995 1996 - 2000 2001 - 2005 2006 - 2010
No.: of publications
Year of publication
Publications "EliSpot" NCBI
Availability of EliSpot Reader systems
世翔國際有限公司
HIV 18%
TB 9%
Malaria 3%
Transplantation 10%
EBV 3%
CMV 3%
Cancer 24%
Allergy 5%
others 25%
Investigation of specific immune response in infections Mainly (>90% ) INF-γ is used
Standard tool in development vaccine canditates
Method of choice to monitor new (HIV) vaccine canditates
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Part 2: EliSpot in Diagnostics
世翔國際有限公司
Lalvani et al. , Am J Respir Crit Care Med, 163, 824-828 (2001)
Major drawbacks of the commonly used tuberculin skin test (TST):
- low sensitivity and low specificity
- false-positive results due to BCG vaccination
- needs return visit
- administration and reading is highly operator dependent
12. Aug. 2004: First available diagnostic kit based on the EliSpot technology (Oxford Immunotec, UK).
世翔國際有限公司
RD1 Gen-Region: ESAT-6: Early Secreted Antigenic Target (6kDa) CFP-10: Culture Filtrate Protein (10kDa)
Region of difference, RD1
CFP-10 ESAT-6
M. tuberculosis M. africanum, M. bovis
M. kansasii, M. marinum, M. szuigai
M. tuberculosis BCG
Most environmental strains Andersen P et al. Lancet 2000;356:1099
世翔國際有限公司
Negative control Positive control
ESAT-6 CFP-10
世翔國際有限公司
• Not impaired by BCG-Vaccination
• High sensitivity and specificity
• Responds early to infection
• Diagnoses active and latent TB
• Diagnoses extrapulmonary TB
• Single patient visit, fast procedure
• Data from more than 20.000 subjects available
• Worldwide accepted as diagnostic tool
• Also known as one of the “IGRA”, Interferon-γ Releasing Assay (& ELISA)
世翔國際有限公司
Method TST EliSpot ELISA
BCG vaccination Affected Not affected Not affected
Specificity Low > 95% > 95%
Sensitivity Low (<70%) >95% >80%
HIV subjects Yes Yes (Lower sensitivity)
Elderly/children/IS Yes Yes (Lower sensitivity)
Readout system EliSpot (cell-counting) ELISA (OD)
Regulatory approvals Europe /Canada/FDA Europe/Canada/FDA
IGRA: Interferon-γ releasing assays
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Part 3: Limitations of EliSpot
Development of FluoroSpot
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Giuseppe Pantaleo and Alexandre Harari
NATURE REVIEWS | IMMUNOLOGY, vol 6 417-23, 2006
Levels of disease activity and viral replication correlate with distinct functional signatures of T-cell responses (e.g. IFN/IL-2)
Examples:
• HIV
• HCV
• CMV, EBV
• and others
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Red signal
Blue signal
?
?
?
IL-2
IL-2/IFN
IFN
IFN ??
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]FITC
Overlay
Result Reset
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]Part 4: The AID EliSpot/FluoroSpot Reader portfolio
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]EliSpot Reader Systems
Basic EliSpot Reader for 96-well plates 5 Mpix firewire-driven camera
AID EliSpot Reader Systems „Classic“ iSpot Reader System
FluoroSpot/EliSpot Reader for 96-well plates
2 Mpix firewire-driven camera, fluorescent optimized 2-3 color assays
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]EliSpot Reader Systems
iSpot Spectrum
• High Resolution, multi-color FluoroSpot /EliSpot analysis
• 5 Megapixel firewire camera
• 7&1 filter wheel for 7 single banded fluorescent filters plus one LED
• Fully automated input / output module for 96-well plates
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]vSpot Reader System
• High resolution, multi-color FluoroSpot /EliSpot and Virus Plaque analysis
• 5 Megapixel firewire camera, optimized for fluorescent imaging
• 7 &1 filter wheel for 7 single banded fluorescent filters plus one LED
• 6,12, 24, 48 and 96 well layout EliSpot Reader Systems
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]MultiSpot Reader System
The MultiSpot Reader System
• Enzymatic and fluorescent EliSpot assays
• Cell counting and viability tests, autofocus microscope with 2.5x, 20x and 40x objective
• IF-based tissue assays
• HLA screening assays
• Tailor-made solutions on 96well plates, slides and Terasaki plates
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]600 users
UK and Australia >95% of the market
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]National Institute of Health (NIH), US National Cancer Institute (NCI), US
Food and Drug Administration (FDA ), US
Center for Disease Control and Prevention (CDC), US CDC, China
Bayer Healthcare Merck & Co.
Merck Research Laboratories Sanofi Pasteur, Canada
Sanofi Pasteur, USA Centocor
Pfizer Novartis Baxter Roche Amgen Genzyme Celgene
世翔國際有限公司
Autoimmun Diagnostika GmbH
Ebingerstraße 4 D-72479 Straßberg Tel.: +49 (0) 7434/9364-0 [email protected]• Improved two/three color analysis, patented well overlay technology
• Software driven 7 & 1 filter wheel (7x fluorscent filter, 1x LED light source)
• Optimized for two/three-color assays
• One mouse-click switch between fluorescent and enzymatic assays
• Speed: < 2min enzymatic mode, <6min fluorescent mode
• User defined input of external data such as cell type, antigen etc.
• Calculation of SFU and results based on user defined rules
• Calculation of cytokine release in addition to spot counting
• Improved statistical analysis
• Comparison of different plates for long-term studies
• Export to Excel, Excel, txt, Access, Powerpoint, LIMS, AIDiagnostics
• Collection of various plates in one Excel sheet
• Quality control of the optical system via software and masterplate
• User management
• Validated according to CE and FDA 21 CFR part 11
世翔國際有限公司