• Tidak ada hasil yang ditemukan

Performance of the VAX 11/785 data acquisition system at the KFUPMEnergy Research Laboratory

N/A
N/A
Protected

Academic year: 2023

Membagikan "Performance of the VAX 11/785 data acquisition system at the KFUPMEnergy Research Laboratory"

Copied!
1
0
0

Teks penuh

(1)

Performance Of The VAX 11/785 Data Acquisition System At The KFUPMEnergy Research Laboratory

Abdel-Aal, R.E. Al-Juwair, H.A.;Energy Res. Lab., King Fahd Univ. of Pet.Miner., Dhahran

;

Nuclear Science, IEEE Transactions on;Publication Date: Feb 1989;Vol: 36,Issue: 1, Part 1

King Fahd University of Petroleum & Minerals

http://www.kfupm.edu.sa Summary

The VAX 785 XSYS data acquisition and analysis system at the Energy Research Laboratory (ERL) of King Fahd University of Petroleum and Minerals has been in use since June 1987. The authors describe features unique to the ERL system and present data on the various aspects of its performance in comparison with other XSYS

installations, including data acquisition, sorting, and dumping onto disks and tapes.

Results show the effects of data rates and key system parameters on both system deadtime and CPU (central processing unit) time usage

For pre-prints please write to:abstracts@kfupm.edu.sa

© Copyright: King Fahd University of Petroleum & Minerals; http://www.kfupm.edu.sa

Referensi

Dokumen terkait

of Pet.Miner., Dhahran ; Power Systems, IEEE Transactions on;Publication Date: Nov 1997;Vol: 12,Issue: 4 King Fahd University of Petroleum & Minerals http://www.kfupm.edu.sa

of Pet.Miner., Dhahran; Power Systems, IEEE Transactions on;Publication Date: Nov 1998;Vol: 13,Issue: 4 King Fahd University of Petroleum & Minerals http://www.kfupm.edu.sa