• Tidak ada hasil yang ditemukan

Supplementary Information

N/A
N/A
Protected

Academic year: 2024

Membagikan "Supplementary Information"

Copied!
12
0
0

Teks penuh

(1)

Photoinduced triplet-state electron transfer of platinum porphyrin: a one-step direct method for sensing iodide with an unprecedented detection limit

Item Type Article

Authors Masih, Dilshad;Aly, Shawkat Mohammede;Alarousu, Erkki;Mohammed, Omar F.

Citation Photoinduced triplet-state electron transfer of platinum

porphyrin: a one-step direct method for sensing iodide with an unprecedented detection limit 2015, 3 (13):6733 J. Mater. Chem. A Eprint version Publisher's Version/PDF

DOI 10.1039/C4TA07033J

Publisher Royal Society of Chemistry (RSC) Journal Journal of Materials Chemistry A

Rights This article is licensed under a Creative Commons

Attribution-NonCommercial 3.0 Unported Licence. http://

creativecommons.org/licenses/by-nc/3.0/

Download date 2023-12-13 18:11:13

Link to Item http://hdl.handle.net/10754/579541

(2)

Supplementary Information

Photoinduced triplet-state electron transfer of platinum porphyrin: A one- step direct method for sensing iodide to an unprecedented detection limit

Dilshad Masih, Shawkat M. Aly

, Erkki Alarousu and Omar F. Mohammed*

Solar and Photovoltaics Engineering Research Center, Division of Physical Sciences and Engineering, King Abdullah University of Science and Technology, Thuwal 23955-6900,

Kingdom of Saudi Arabia

*Corresponding author, Email: [email protected] Electronic Supplementary Material (ESI) for Journal of Materials Chemistry A.

This journal is © The Royal Society of Chemistry 2015

(3)

Estimation of Detection Limit for Iodide with Pt(II)TMPyP in Aqueous Phase

Detection Limit = 3σ/slope

= 3 x 0.025/67.54

= 1 pmol

Multiple number of PL spectra (5–7) were recorded for the aqueous phase Pt(II)TMPyP alone. Sample Standard Deviation was calculated for the peak intensity value using ‘Statistics on Columns’ option in origin software and verified with online calculator. Sample Standard Deviation (0.025) is close to Population Standard Deviation (0.022). Standard deviation for the blank fluorophore, Pt(II)TMPyP porphyrin solution, without the addition of iodide was 0.025.

Fig. S1 Relation of photoluminescence intensity against the iodide added into Pt(II)TMPyP and linear fit for estimation of detection limit.

(4)

Steady-State UV-Vis Absorption and PL Spectra for Pt(II)TMPyP, and with Halides

Fig. S2 UV-Vis absorption (left), and photoluminescence (right, λex = 512 nm) spectra for Pt(II)TMPyP and after successive additions of various halides i. e. chloride, bromide, and iodide in aqueous phase.

(5)

Stern-Volmer Plots Corresponding to Steady-State PL Spectra for Pt(II)TMPyP-Halide Systems

Fig. S3 Stern-Volmer plots for Pt(II)TMPyP, and with the maximum amounts of halides added into it for similar quenching (corresponding to PL spectra in Fig. S2).

(6)

Time Correlated Single Photo Counting of Pt(II)TMPyP, and with Iodide

Fig. S4 Time correlated single photon counting for Pt(II)TMPyP porphyrin, and with successive additions of iodide in aqueous phase. Corresponding lifetimes extracted from kinetic traces monitored at em = 660 nm are given on graph and standard errors included in parenthesis.

(7)

UV-Vis Absorption and PL Spectra for Pt(II)TMPyP, and with Iodide in Methanol

Fig. S5 UV-Vis absorption (left), and photoluminescence (right, λex = 512 nm) spectra for Pt(II)TMPyP, and after successive additions of iodide in organic phase, methanol.

UV-Vis Absorption and PL Spectra for Zn(II)TMPyP, and with Iodide

(8)

Transient Absorption Studies on Zn(II)TMPyP, and with Iodide

(9)

Helios – Femtosecond Transient Absorption of Pt(II)TMPyP, and with Iodide

Fig. S8 Femtosecond transient absorption spectra of Pt(II)TMPyP porphyrin, and with addition of iodide in aqueous phase (λex = 350 nm; λmonitoring 350–700 nm), excitation energy density = 1.44 mJ/cm2.

(10)

Kinetics of Femtosecond TA Spectra of Pt(II)TMPyP, and with Iodide

Fig. S9 Kinetics of femtosecond transient absorption spectra of Pt(II)TMPyP porphyrin, and with addition of iodide in aqueous phase. Monitoring wavelengths are 443 nm for excited-state absorption and 401 nm for ground-state bleach.

(11)

Steady-State UV-Vis Absorption and PL Spectra for Pt(II)TMPyP, and with Fluoride

Fig. S10 UV-Vis absorption (left), and photoluminescence (right, λex = 512 nm) spectra for Pt(II)TMPyP, and after successive additions of fluoride in aqueous phase.

(12)

Detailed Description of Ultra-sensitive Halide Detection with Pt(II)TMPyP Porphyrin

In the presence of halide ions, the quenching of the photoluminescence of Pt(II)TMPyP can be directly monitored upon irradiation with visible light. Pt(II) porphyrin phosphorescence was quenched to different magnitudes through the use of different halides (Fig. 1). The efficiency of quenching was experimentally demonstrated to increase in the order chloride < bromide <

iodide. In the Pt(II)TMPyP porphyrin, the central cavity is filled with Pt(II) metal and that makes it interesting candidate as a senor for the detection of halides. A previous study with metal-free porphyrin dissolved in organic solvent reported a poor sensitivity towards detection of halide (Ref. 19; Makrogeterotsikly, 2008, 50). It is interesting to note that Pt(II) porphyrin demonstrated similar sensitivity towards iodide detection in methanol (Fig. S5), and in aqueous phase (Fig.

S2). A specific metal filling the central cavity of porphyrin has important role, and when Pt(II) was exchanged with Zn(II) sensing function for similarly dilute aqueous solutions of halides was almost lost (Fig. S6). It would mean that the Pt metal center is the key component of the sensing down to such an extremely detection limit.

The photoluminescence quenching upon the addition of halides indicates the presence of a photoinduced electron transfer event between the halide donor and the Pt(II)TMPyP acceptor.

Non-linear Stern-Volmer plots for all of the detected halide ions indicate a static reaction for the quenching process (Fig. S3). Furthermore, the bimolecular quenching rate constant, kq ≈ 7.8 × 1012 M-1s-1 far exceeds the diffusion-controlled limit (~3 × 1010 M-1s-1) establishing the fact that the quenching is due to static interaction, and confirmed by recording phosphorescence lifetimes (Fig. S4).

The transient absorption spectra of Pt(II)TMPyP-halides demonstrate shortening in the order;

Pt(II)TMPyP alone > chloride > bromide > iodide (Fig. 2). And this was confirmed from the kinetic traces for the ground-state bleach recovery time values extracted from the transient absorption spectra (Fig. 3). This overall fast deactivation of the triplet signal implies the presence of an extra process involved in deactivation of the excited state when halides are present compared to the case of free Pt(II) porphyrin. Moreover, for the control experiment with Zn(II)TMPyP-iodide system, no appreciable changes were observed in transient absorption

Referensi

Dokumen terkait

56 Photoluminescence and optical propertiesstudyof Dy doped Lithium Calcium Borate Glasses3+- Optical Properties Absorption Spectra Optical absorption spectrum of 0.5 mol% of Dy3+

68 Figure 4.9 Shows Test A: Diagram A shows prepared sample E ablated for 25 minutes and B shows the UV-VIS absorption spectra of AgNPs sample E, synthesised using 1064 nm and 532 nm

UV-vis absorption spectra of the pristine Ta2O5 and synthesized TaON with different melamine ratio the shown ratios were weight ratio of N in melamine/Ta in Ta2O5 ··· 27 Figure 10..

Wavelength nm 1 2 3 4 5 6 Number of Washing Figure S3: UV-Vis spectra of successive washing steps to remove unbound AHB from non- covalently modified MWNTs Selective

Hydrothermal and solid phase reaction method were used to synthesize of Si/CNTs photocatalysts and characterized by using UV–visible optical absorption spectra UV–Vis, Transmission

Typical Uv-vis spectra irradiated of Ag /CTS 120kDa solution with doses A and Uv-vis spectra of Ag-NPs/CTS solution with different M„ at conversion dose B As known from Mie theory for

UV-Vis spectroscopy UV-Vis absorption is performed to verify the presence of silver and nickel nanoparticles in the prepared samples of PANI-Ni-Ag nanocomposite thin films as shown in

UV- vis absorption spectra of the PCPDT-BT thin films prepared with various dipping times in b methylene chloride, c hexanes, d acetone.. The dipping time increased in the direction of