DAFTAR ISI
LEMBAR JUDULLEMBAR PERNYATAAN ORISINALITAS……….. ii
LEMBAR PRASYARAT GELAR SARJANA ………... iii
LEMBAR PENGESAHAN ………... iv
KATA PENGANTAR ………... v
ABSTRAK ……….. vi
ABSTRACT ………... vii
DAFTAR ISI………... viii
DAFTAR GAMBAR……….. xi
DAFTAR TABEL………... xii
DAFTAR LAMPIRAN………... xiii
BAB I. PENDAHULUAN 1.1 Latar Belakang……….. 1 1.2 Rumusan masalah………. 2 1.3 Tujuan Penelitian……….. 2 1.4 Manfaat Penelitian……… 2 1.5 Batasan Masalah………... 3 1.6 Sistematika Penulisan………... 3
BAB II. KAJIAN PUSTAKA 2.1 Tinjauan Mutakhir……….. 4
2.2 Sistem Tenaga Listrik………... 5
2.3 Instalasi Listrik……….. 6
2.4 Saluran Penghantar………... 7
2.5 Penentuan Penghantar………... 8
2.5.1 Penggunaan Kabel NYA……… 8
2.5.3 Kabel NYY……… 9
2.6 Identifikasi Penghantar dengan Warna………. 9
2.7 Menentukan Penampang Penghantar dengan Dasar Arus Beba……... 10
2.8 Panel hubung Bagi (PHB) Konsumen……….. 11
2.8.1Peranan Panel Hubung Bagi (PHB) dalam suatu Bangunan……. 12
2.9 PHB Utama Fase Satu………. 13
2.9.1 PHB Utama Fase Tiga………... 14
2.10Daya pada Saluran Distribusi……… 15
2.11Sistem Tiga Phase………. 16
2.11.1 Sistem Bintang (Y) dan Delta (∆)………... 17
2.11.2 Beban Seimbang Terhubung Bintang (Y)………... 17
2.11.3 Beban Seimbang Terhubung Delta (∆)……… 19
2.11.4 Beban Tidak Seimbang Terhubung Bintang (Y)………. 20
2.11.5 Beban Tidak Seimbang Terhubung Delta (∆)……… 20
2.12Arus Netral……… 21
2.12.1 Arus Netral Karena Beban Tidak Seimbang………... 21
2.13Ketidakseimbangan Beban……… 22
2.13.1 Keadaan Seimbang dan Tidak Seimbang……… 22
2.14Penyaluran dan Rugi-rugi Daya……… 23
2.15Rugi – Rugi Daya Pada Instalasi listrik…...………. 25
2.16Rugi- Rugi Daya Akibat Ketidakseimbangan Beban………..…. 26
2.17Arus Beban Penuh... 26
BAB III. METODE PENELITIAN 3.1 Tempat dan Waktu Penelitian………... 27
3.2 Data………... 27
BAB IV. ANALISIS DAN HASIL
4.1 Tinjauan Umum Sistem Kelistrikan Fakultas Teknik Universitas Udayana Denpasar……… 30 4.2 Data Sistem Kelistrikan di Kampus Fakultas Teknik Udayana…….. 30 4.2.1 Tabel Pengukuran Pada kWH 1 Ruang Administrasi……… 32 4.2.2 Tabel Pengukuran Pada MDP 2 Gedung C………... 32
4.3 Analisis………. 33
4.4 Menghitung Prosentase Pembebanan Pada Masing-masing MDP…... 33 4.4.1 Prosentase Pembeban Pada MDP1……… 33 4.4.2 prosentase Pembebanan pada MDP2……… 34 4.5 Perhitungan Ketidakseimbangan Beban Masing-masing MDP……… 34 4.5.1 Ketidakseimbangan Beban MDP1………. 34 4.5.2 Ketidakseimbangan Beban MDP2………. 35 4.6 Analisis Rugi-rugi Daya pada Setiap SDP……… 36
4.6.1 Analisis Rugi-rugi Daya Kondisi Beban Seimbang Disetiap
SDP……… 36
4.6.2 Analisis Rugi-rugi Daya Kondisi Beban tidak Seimbang disetiap
SDP……… 43
4.6.2.1 Rugi-rugi daya pada beban penghantar SDP……….. 44 4.7 Hasil Perbandingan Rugi-rugi Daya Kondisi Seimbang dan Tidak
Seimbang………... 56 BAB V. KESIMPULAN DAN SARAN
5.1 Kesimpulan………... 57
5.2 Saran………. 57
DAFTAR PUSTAKA LAMPIRAN-LAMPIRAN
ABSTRAK
Pembangunan sarana dan prasarana yang dilakukan oleh Fakultas Teknik Universitas Udayana baik di kampus Bukit Jimbaran maupun Kampus Fakultas Teknik di Jalan PB. Sudirman Denpasar secara terus menerus dilaksanakan. Pembangunan tersebut dimaksudkan dalam rangka menjadikan Fakultas Teknik sebagai lembaga pendidikan yang dapat melaksanakan Tri Dharma Perguruan Tinggi yang berkualitas. Tujuan dari penelitian ini adalah menganalisis pengaruh ketidakseimbangan beban terhadap arus, tegangan daya, serta menghitung seberapa besar rugi-rugi daya yang terjadi akibat ketidakseimbangan beban pada instalasi listrik.
Berdasarkan analisis yang dilakukan, didapatkan hasil pengukuran beban pada setiap MDP Kampus Fakultas Teknik Universitas Udayana dalam keadaan tidak seimbang. Dapat diketahui berdasarkan hasil perhitungan rugi-rugi daya pada masing-masing SDP, rugi-rugi daya beban tidak seimbang lebih besar di bandingkan rugi-rugi daya pada kondisi beban seimbang.
Rugi-rugi daya beban seimbang MDP1 adalah 42,688 Watt sedangkan MDP2 adalah 286,56 Watt. Sedangkan pada kondisi beban tidak seimbang rugi-rugi daya pada MDP1 adalah 55,929 Watt dan MDP2 adalah 357,087 Watt. Rugi-rugi daya yang terjadi pada instalasi listrik akan semakin besar apabila arus yang mengalir pada intalasi menjadi semakin besar. Untuk memasang sambungan baru pada instalasi listrik harus memperhatikan data-data yang ada, agar penyambungan pembebanan pada salah satu fasa tidak terlalu besar hal ini dapat mengakibatkan pembebanan yang tidak seimbang semakin besar.
ABSTRACT
Infrustructure development whith is understane by both on campus of Udayana University in Bukit Jimbaran and campus of Faculty of Engineering at JL PB Sudirman-Denpasar. Continuously implemented this development is in tended to achieve the goal that Faculty of Engineering as and educational institution can carry out the Tri Dharma cancepty which means that having a responsibility of providing education, research and community service as a campus which have good quality. The aim of this study is analyzing the effect of imbalance load on the current, voltage power and measuring the losses power that occur due to the imbalance of load in the electrical installation.
Based on the analysis, the result of load measure in eat for each MDP of Faculty of engineering of Udayana University is in unbalanced condition. The imbalance load on MDP1 is 66,66% and MDP2 is 30%, Besides that the losses power that occurs in the electrical installation will be greater if the current which flows on electrical installation is greater as well. There fore in order to install the connection point on the electrical instalation it is need to pay attention to the data. So that the loading connection of one power is not too large this may result on the greater imbadunced load.
BAB 1
PENDAHULUAN
1.1 Latar Belakang
Listrik adalah salah satu faktor terpenting dalam setiap kegiatan sehari-hari.
Listrik sudah menjadi kebutuhan pokok sehingga segala aktifitas manusia tidak bisa
lepas dari manfaat listrik. Dari tahun ke tahun pembangunan sarana dan prasarana
yang dilakukan oleh Fakultas Teknik Universitas Udayana baik di kampus Bukit
Jimbaran maupun Kampus Fakultas Teknik di Jalan PB. Sudirman Denpasar secara
terus menerus dilaksanakan. Pembangunan tersebut dimaksudkan dalam rangka
menjadikan Fakultas Teknik sebagai lembaga pendidikan yang dapat melaksanakan
Tri Dharma Perguruan Tinggi yang berkualitas, mendukung pembangunan yang
berkelanjutan dan mampu bersaing secara global.
Tempat kegiatan tidak terlepas dari pemakaian energi listrik adalah ruang
administrasi, ruang perpustakaan, ruang perkuliahan dan studio arsitektur. Semakin
bertambahnya jumlah ruangan perkuliahan dan meningkatnya pemakaian listrik
seperti penggunaan lampu penerangan, Air Conditioner (AC) peralatan studio
arsitektur dan lain-lain, mengakibatkan terjadi peningkatan pemakaian energi listrik
yang mengalir pada instalasi. Pembagian beban yang tidak seimbang mengakibatkan
arus yang mengalir pada salah satu fasa akan melebihi KHA (kemampuan hantar
arus) dari kabel, sehingga menyebabkan konduktor pada fasa yang paling tinggi
panas, setelah pemakaian dalam waktu cukup lama suhu panas yang dihasilkan kawat
tembaga mampu me-lelehkan pembungkus kawat dan titik tertentu akan
menyebabkan MCB trip.
2
Sedangkan pada MDP 2,penggunaan beban pada fasa R= 135,5 A, pada fasa S
= 77,6 A, fasa T= 62 A, dan N = 63,1 A. Fakultas Teknik Universitas Udayana
memiliki Dua Main Distribution panel yang berada pada ruangan administrasi, dan
gedung C. Tiap MDP (Main Distribution panel) dibagi kedalam beberapa grup SDP
(Sub Distribution panel) di setiap lantai.
1.2 Rumusan Masalah
Dari uraian diatas, maka dapat dirumuskan permasalahan sebagai berikut:
1. Apa dampak pengaruh ketidakseimbangan beban pada instalasi listrik di gedung
Fakultas Teknik Universitas Udayana Jalan PB Sudirman?
2. Berapa besar rugi-rugi daya akibat dari ketidakseimbangan beban di gedung
Fakultas Teknik Universitas Udayana Jalan PB. Sudirman?
1.3 Tujuan Penelitian
Tujuan dari penelitian ini adalah sebagai berikut:
1. Menganalisis pengaruh beban ketidakseimbang terhadap arus, tegangan, dan daya
pada gedung Fakultas Teknik Universitas Udayana.
2. Menganalisis seberapa besar rugi-rugi daya dan efisiensi yang terjadi akibat
ketidakseimbangan beban pada instalasi listrik di gedung Fakultas Teknik
Universitas Udayana.
1.4 Manfaat Penelitian
Adapun manfaat yang akan diperoleh dari pembahasan ini adalah :
1. Dapat mengetahui besar kerugian yang dihasilkan akibat beban yang tidak
seimbang pada instalasi listrik.
2. Dapat digunakan sebagai dasar untuk pengambilan tindakan untuk meminimalkan
dan meningkatkan kualitas tegangan dalam menghadapi kasus-kasus gangguan
akibat beban tidak seimbang.
3