EDITORIAL BOARD
Dewan Redaksi
SUSUNAN DEWAN REDAKSI MEDIA KEDOKTERAN HEWAN 2006 – 2010 Ketua Penyunting : Epy Muhammad Luqman
Sekretaris : Erma Safitri Bendahara : Diah Kusumawati Gali Iklan dan Langganan : Budiarto Penyunting Pelaksana :
1. Sri Subekti
2. Bendryman Soedjoko 3. Mas’ud Hariadi 4. Fedik Abdul Rantam 5. Suwarno
6. Agus Sudjarwo
Penyunting Teknik : Kusnoto Thomas Valentinus Widiyatno Tata Usaha : Berty Ferijanti
Table of Contents
No Title Page
1 Correlation Between Motility With Viability and Membrane Integrity of Boer Goat Sperm Before Freezing and Post Thawing
1 - 8 2 Peningkatan Kualitas Semen Beku Kambing PE melalui Suplementasi Antioksidan
α–tocoferol dalam Pengencer Semen untuk Inseminasi Buatan
9 - 28 3 Radiological Evaluation of femoral Fractures Healing in Male Rat with Cissus
quadrangularis Extract
29 - 41 4 Characteristic of Carcas, Meat Tenderness and Marbling of Beef Cattle at Manokwari 42 - 50 5 Concentration determination of Growth Factor Insuline Like Growth Factor-1 (IGF-1)
Produced by Liver and Cumulus Cells Monolayer Culture
51 - 56 6 Morphometry of the Kidney and Abdominal Aorta of Indonesian Domestic
Cat through Two Dimensional Ultrasonography Diagnostic Approach
Vol. 30 - No. 1 / 2014-01 TOC : 6, and page : 57 - 68
Morphometry of the Kidney and Abdominal Aorta of Indonesian Domestic Cat through Two Dimensional Ultrasonography Diagnostic Approach
Morfometri Ginjal dan Aorta Abdominalis Kucing Domestik Indonesia dengan Pendekatan Diagnostik Ultrasonografi Dua Dimensi
Author :
Deni Noviana | d_noviana@hotmail.com
Bagian Bedah dan Radiologi, Departemen Klinik, Reproduksi, dan Patologi, Fakultas Kedokteran Hewan, Institut Pertanian Bogor
Ruri Indrian | deni@ipb.ac.id
Bagian Bedah dan Radiologi, Departemen Klinik, Reproduksi, dan Patologi, Fakultas Kedokteran Hewan, Institut Pertanian Bogor
Rr Soesatyoratih | deni@ipb.ac.id
Bagian Bedah dan Radiologi, Departemen Klinik, Reproduksi, dan Patologi, Fakultas Kedokteran Hewan, Institut Pertanian Bogor
R Harry Soehartono | d_noviana@hotmail.com
Bagian Bedah dan Radiologi, Departemen Klinik, Reproduksi, dan Patologi, Fakultas Kedokteran Hewan, Institut Pertanian Bogor
Gunanti | d_noviana@hotmail.com
Bagian Bedah dan Radiologi, Departemen Klinik, Reproduksi, dan Patologi, Fakultas Kedokteran Hewan, Institut Pertanian Bogor
Abstract
Abstrak Penelitian ini bertujuan untuk mengetahui struktur internal dan ukuran ginjal normal kucing domestik Indonesia serta untuk mendapatkan rasio panjang ginjal normal dan diameter aorta
abdominalis melalui pendekatan ultrasonografi (USG) dua dimensi. Pengamatan dilakukan pada lima ekor kucing jantan domestik Indonesia dengan bobot badan 3.0-4.0 kg dan umur 2–5 tahun.
Sonogram ginjal dengan menggunakan transduser linear 7.5 MHz dilakukan setelah kucing teranastesi pada posisi pemeriksaan hewan lateral recumbency. Morfologi struktur internal ginjal berupa kapsula, korteks, dan medula dapat dibedakan dengan baik menggunakan ultrasonografi dua dimensi. Parameter kuantitatif yang diamati adalah panjang (p), lebar (l), dan tinggi (t) ginjal, lebar korteks ginjal, panjang dan tinggi medula ginjal, serta diameter aorta abdominalis. Pengukuran terhadap sonogram ginjal dilakukan dengan menggunakan software MacBiophotonics ImageJ©. Rataan pengukuran ginjal kanan adalah p = 3.92±0.30 cm, t = 2.59±0.11 cm, dan l = 2.66±0.27 cm, sedangkan untuk ginjal kiri adalah p = 3.85±0.31 cm, t = 2.62±0.31 cm, dan l = 2.72±0.18 cm. Rasio panjang maksimum ginjal dan diameter aorta abdominalis untuk ginjal kanan adalah
7.91±1.54 dan 7.76±1.38 untuk ginjal kiri. Hasil penelitian ini dapat dijadikan sebagai acuan terhadap ukuran ginjal normal kucing domestik. Melalui pendekatan ultrasonografi didapatkan juga rasio panjang ginjal dengan diameter aorta abdominalis Abstract The purpose of this study was to determine the normal kidney size of the Indonesian Domestic Cat and to define the normal ratio of kidney length and abdominal aorta diameter through two dimensional ultrasonography (USG). Ultrasonography was performed on five male cats weighing 3.0-4.0 kg and age 2–5 years old. Cats were anesthetized and USG was performed on the lateral recumbency using a 7.5 MHz linear transducer. The internal structures morphology of kidney i.e. capsule, cortex and medulla can be clearly defined by using two dimensional USG. The quantitative parameters observed were length (l), width (w), and height (h) of the kidney, width of the cortex, length and height of the medulla, and diameter of the abdominal aorta. Measurement of the sonogram was performed using ImageJ software MacBiophotonics©. Measurement of right kidney were l = 3.92±0.30 cm, h = 2.59±0.11 cm, and w = 2.66±0.27 cm, for left kidney were l = 3.85±0.31 cm, h = 2.62±0.31 cm, and w = 2.72±0.18 cm. The ratio of maximum length of kidneys and diameter of the abdominal aorta was
7.91±1.54 for right kidney and 7.76±1.38 for left kidney. As a conclusion, the results of this study can be used as a reference of a normal kidney size of Indonesian domestic cats. Through ultrasound approach also obtained the ratio of renal length to diameter of the abdominal aorta.
Keyword : abdominal, aorta, kidney, domestic, cat, , , , , , ,
Daftar Pustaka :
1. Barr F, (1990). Diagnostic Ultrasound in The Dog and Cat. Oxford. Blackwell Scientific Publications. . :
-2. Bhatt S, Ghazale H, and Dogra VS, (2007). Sonographic Evaluation of The Abdominal Aorta. Ultrasound Clin 2: 437456. . :
-3. Carlton WW, and McGavin MD. , (1995). Thomson’s Special Veterinary Pathology. St. Louis: MosbyYear Book. Inc. . :
-4. Dapla PK, (2010). Renal Function in Diabetic Nephrophaty. World J Diabetes, 15;1(2): 48-56.. - :
-5. Dimitrov RS, (2012). Ultrasound features of kidneys in the rabbit (Oryctolagus cuniculus). Veterinary World, 5(5). . :
-6. Gao J, Amelia, Shih G, Goldstein M, Kapur S, Wang J, and Min RJ. , (2007). Intrarenal Color Duplex Ultrasonography a Window to Vascular Complications of Renal Transplants. J Ultrasound Med, 26:14031418.. :
-7. Granata A, Fiorini F, Andrulli S, Logias F, Gallieni M, Romano G, Sicurezza E, and Fiore
CE. , (2009). Doppler ultrasound and renal artery stenosis: An overview. Journal of Ultrasound.,
20:111.. :
-8. Kakadiya J, and Shah N. , (2010). Renal Function Markers:A Short Review. Journal of Innovative trends in Pharmaceutical Sciences. 1(6):270273.. :
9. Kamonrat P. , (2009). Ultrasound Diagnosis. Thai J. Vet. Med. 39(2):187189.. :
-10. Kim HC, Yang DM, Lee SH, and Cho YD, (2008). Usefulness of Renal Volume Measurements Obtained by a 3-Dimensional Sonographic Transducer With Matrix Electronic Arrays. J Ultrasound Med, 27:16731681. . :
-11. Mannion P, (2006). Diagnostic Ultrasound in Small Animal Practice. Oxford. Blackwell Publishing company. . :
-12. Mantis P. , (2008). Ultrasonography of the Urinary and Genital System of the Dog and Cat. Iranian Journal of Veterinary Surgery. University of London. London. . :
-13. Mareschal A, D’Anjoe M-A, Moreau M, Alexander K, Beauregard G, (2007).
Ultrasonographic Measurement of Kidney to Aorta Rasio as a Method of Estimating Renal Size in Dogs. Vet Radiol Ultrasoun, 48: 434–438. . UK :
-14. Moarabi A, Mosallanejad B, Ghadiri AR, Borujeni MP. , (2011). Ultrasonographic
Evaluation of the Urinary System in New Zealand White Rabbit and Tolai Hare. Veterinary Research Forum, 2(2):113120.. :
-15. [NIH] National Institut of Health, (2009). Image J Software. [Terhubung Berkala]. http://rsbweb.nih.gov/ij/download.html. [15 Januari 2012]. . :
-Copy alamat URL di bawah ini untuk download fullpaper : journal.unair.ac.id/filerPDF/mkhc7424ec11ffull.docx