Protelindo Site ID
Protlindo Site Name
Date
Time WIB / WITA / WIT
Grounding Measurement : Ohm ( < 1 Ohm )
Grounding Well : Ohm ( < 1 Ohm )
Tower Leg : Ohm ( < 1 Ohm )
Fence : Ohm ( < 1 Ohm )
Genset Tank : Ohm ( < 1 Ohm )
Grounding Status :
Lightening Rod : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...
BAR grounding tower : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ………
BAR grounding well : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ………
Down conductor Cable : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ………
Bolt Connection : OK NOK Remark : ( uncompleted condition / stolen / broken / worse connection ), ………
Tower Type : SST Monopole Triangle Pole Mini Tower
Painting Condition : OK NOK Remark : ( tower loosen paint 70 % ), GALVANIS
Construction Condition : OK NOK Remark : ( paving down/ tower leg cracked ), ………….
Tower Cleaning : OK NOK Remark : ( cleaning from spider nest / bee / etc ), ………….
Tower Lamp / OBL : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….
Photo Sensor : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….
Base Service
CHECK LIST PREVENTIVE MAINTENANCE
MECHANICAL ELECTRICAL
: JAW-CJV-0004-D-P
: TEMBALANG (SEMARANG)
: 06/03/2012
: 10:18:00 AM
GROUNDING ………. ………. 0,33 0,36 N/A TOWER LIGHTING
Tower Lamp (OBL) Amount : 4 Unit
Yard Lamp Amount (Mercury & TL) : 1 Unit
Tower Lamp (OBL) Condition : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….
Yard Lamp Condition : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….
Site Photo Sensor : OK NOK N/A Remark : ( sensor respon checking ), ………….
Yard Lamp Shield : OK NOK N/A Remark : ( lamp shield checking broken / no ), …….
Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), ………….
Site Cleaning : OK NOK Remark : ( cleaning for grass / garbage )………
Flume Cleaning : OK NOK Remark : ………
Paving Block or Gravel : OK NOK Remark : ………
Barbared Wire : OK NOK Remark : ………
Fence Door (Swing/Sliding) : OK NOK Remark : ………
ENVA Check Respons
Lightening Alarm : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Obstruction Light Failure : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Grounding System : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Fence Break : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
( HARI )
INSPECTION BY
LIGHTING
FENCE
ENVA STATUS
Protelindo Site ID Date
Protlindo Site Name Time WIB / WITA / WIT
Operator
Equipment Type : Indoor Outdoor AC Amount : 2 unit
AC Mark : Daikin National Others / PANASONIC 1,5 PK
Broken AC YES NO YES NO YES NO YES NO
Power 1,5 1,5
Pressure 70 70
Current Max Current Measurement
AC Indoor Condition OK NOK OK NOK OK NOK OK NOK
Pipe Condition OK NOK OK NOK OK NOK OK NOK
Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A
Switch Contactor OK NOK OK NOK OK NOK OK NOK
AC Temperature Setting OK NOK OK NOK OK NOK OK NOK
Room Temperature :
Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK
Shelter Roof : OK NOK N/A Remark : ( leak, broken ), ………….
Dinding Shelter : OK NOK N/A Remark : ( cracked, leak, broken ), ………….
Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), ………….
Room Cleaning : OK NOK Leak Remark : ………
Roof Cleaning : OK NOK Leak Remark : ………
Benzoic Spreading : OK NOK Remark : ( cleaning for grass / garbage )………
Door Hinge Lubrication : OK NOK Remark : ………
Shelter Foundation : OK NOK Remark : ………
Heat Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
6,72 8,28
Tenant
CHECK LIST PREVENTIVE MAINTENANCE
MECHANICAL ELECTRICAL
: JAW-CJV-0004-D-P : 06/03/2012
: TEMBALANG (SEMARANG) : 10:18:00 AM
: FLEXI AIR CONDITIONER
Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4
AC Status PK Psi According with data signed at
AC Outdoor
Ampere Leak / Not Leak Leak / Not Leak Operation test switch < 24 o
C 20,7 EXHAUST FAN SHELTER Alarm System GROUNDING
Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...
Control Box : Ohm ( < 1 Ohm )
External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm )
Base Frame Condition : OK NOK N/A Remark : ... Dynabolt Condition : OK NOK N/A Remark : ... Base Frame Foundation : OK NOK N/A Remark : ...
Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) : V
Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record :
AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition )
COS : OK NOK N/A Remark : ( clean, neat, broken )
PLN Power Supplied : kVA
MCB input :
MCB Condition : OK NOK NA
1 Phase : A pcs
3 Phases : A pcs
COS : A
PLN ID :
Seal
KWH Record : OK NOK NA ( Good Sealed ), ………..……
Terminal / OKA : OK NOK NA ( Good Sealed ), ………..……
MCB : OK NOK NA ( Good Sealed ), ………..……
MCB in the KWH 'ON' Position
A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..…… B. R, S & T Indicator Lamps are lit : OK NOK NA
MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..……
KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……
211 0 378 Measurement 0,39 0,37 0,53 OUTDOOR TYPE
KWH ELECTRICAL MEASUREMENT
217 371
216 373
35037 ELECTRICAL VISUAL CHECK
PLN VISUAL CHECK
52-3040397908
PLN FUNCTION TEST
PT NOKIA SIEMENS NETWORK
INSPECTION BY
23
……… ………
35 3
40
Protelindo Site ID Date
Protlindo Site Name Time WIB / WITA / WIT
Operator
Equipment Type : Indoor Outdoor AC Amount : …………. unit
AC Mark : Daikin National Others / ………..
Broken AC YES NO YES NO YES NO YES NO
Power Pressure Current Max Current Measurement
AC Indoor Condition OK NOK OK NOK OK NOK OK NOK
Pipe Condition OK NOK OK NOK OK NOK OK NOK
Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A
Switch Contactor OK NOK OK NOK OK NOK OK NOK
AC Temperature Setting OK NOK OK NOK OK NOK OK NOK
Room Temperature :
Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK
Shelter Roof : OK NOK N/A Remark : ( leak, broken ), ………….
Dinding Shelter : OK NOK N/A Remark : ( cracked, leak, broken ), ………….
Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), ………….
Room Cleaning : OK NOK Leak Remark : ………
Roof Cleaning : OK NOK Leak Remark : ………
Benzoic Spreading : OK NOK Remark : ( cleaning for grass / garbage )………
Door Hinge Lubrication : OK NOK Remark : ………
Shelter Foundation : OK NOK Remark : ………
Heat Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Tenant
CHECK LIST PREVENTIVE MAINTENANCE
MECHANICAL ELECTRICAL
: JAW-CJV-0004-D-P : 06/03/2012
: TEMBALANG (SEMARANG) : 10:18:00 AM
: ISAT AIR CONDITIONER
Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4
AC Status PK Psi According with data signed at
AC Outdoor
Ampere Leak / Not Leak Leak / Not Leak Operation test switch < 24 o
C
EXHAUST FAN
SHELTER
Alarm System
GROUNDING
Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...
Control Box : Ohm ( < 1 Ohm )
External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm )
Base Frame Condition : OK NOK N/A Remark : ... Dynabolt Condition : OK NOK N/A Remark : ... Base Frame Foundation : OK NOK N/A Remark : ...
Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) : V
Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record :
AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition )
COS : OK NOK N/A Remark : ( clean, neat, broken )
PLN Power Supplied : kVA
MCB input :
MCB Condition : OK NOK NA
1 Phase : A pcs
3 Phases : A pcs
COS : A
PLN ID :
Seal
KWH Record : OK NOK NA ( Good Sealed ), ………..……
Terminal / OKA : OK NOK NA ( Good Sealed ), ………..……
MCB : OK NOK NA ( Good Sealed ), ………..……
MCB in the KWH 'ON' Position
A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..…… B. R, S & T Indicator Lamps are lit : OK NOK NA
MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..……
KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……
Measurement
0,37 -N/A
OUTDOOR TYPE
KWH ELECTRICAL MEASUREMENT
212 0
212 0
212 0
0 2472
ELECTRICAL VISUAL CHECK
PLN VISUAL CHECK
N/A
PLN FUNCTION TEST
PT NOKIA SIEMENS NETWORK
INSPECTION BY
7,7
35 1
……… …………..
40
Protelindo Site ID Date
Protlindo Site Name Time WIB / WITA / WIT
Operator
Equipment Type : Indoor Outdoor AC Amount : …………. unit
AC Mark : Daikin National Others / ………..
Broken AC YES NO YES NO YES NO YES NO
Power Pressure Current Max Current Measurement
AC Indoor Condition OK NOK OK NOK OK NOK OK NOK
Pipe Condition OK NOK OK NOK OK NOK OK NOK
Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A
Switch Contactor OK NOK OK NOK OK NOK OK NOK
AC Temperature Setting OK NOK OK NOK OK NOK OK NOK
Room Temperature :
Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK
Shelter Roof : OK NOK N/A Remark : ( leak, broken ), ………….
Dinding Shelter : OK NOK N/A Remark : ( cracked, leak, broken ), ………….
Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), ………….
Room Cleaning : OK NOK Leak Remark : ………
Roof Cleaning : OK NOK Leak Remark : ………
Benzoic Spreading : OK NOK Remark : ( cleaning for grass / garbage )………
Door Hinge Lubrication : OK NOK Remark : ………
Shelter Foundation : OK NOK Remark : ………
Heat Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….
Tenant
CHECK LIST PREVENTIVE MAINTENANCE
MECHANICAL ELECTRICAL
: JAW-CJV-0004-D-P : 06/03/2012
: TEMBALANG (SEMARANG) : 10:18:00 AM
: TSEL AIR CONDITIONER
Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4
AC Status PK Psi According with data signed at
AC Outdoor
Ampere Leak / Not Leak Leak / Not Leak Operation test switch < 24 o
C
EXHAUST FAN
SHELTER
Alarm System
GROUNDING
Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...
Control Box : Ohm ( < 1 Ohm )
External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm )
Base Frame Condition : OK NOK N/A Remark : ... Dynabolt Condition : OK NOK N/A Remark : ... Base Frame Foundation : OK NOK N/A Remark : ...
Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) : V
Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record :
AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition )
COS : OK NOK N/A Remark : ( clean, neat, broken )
PLN Power Supplied : kVA
MCB input :
MCB Condition : OK NOK NA
1 Phase : A pcs
3 Phases : A pcs
COS : A
PLN ID :
Seal
KWH Record : OK NOK NA ( Good Sealed ), ………..……
Terminal / OKA : OK NOK NA ( Good Sealed ), ………..……
MCB : OK NOK NA ( Good Sealed ), ………..……
MCB in the KWH 'ON' Position
A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..…… B. R, S & T Indicator Lamps are lit : OK NOK NA
MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..……
KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……
Measurement
0,33 0,42 N/A
OUTDOOR TYPE
KWH ELECTRICAL MEASUREMENT
212 0
213 0
212 0
0 1311
ELECTRICAL VISUAL CHECK
PLN VISUAL CHECK
N/A
PLN FUNCTION TEST
PT NOKIA SIEMENS NETWORK
INSPECTION BY
7,7
16 2
……… ………
40
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Contractor
: NOKIA SIEMENS NETWORK
PREVENTIVE MAINTENANCE
PHOTO REPORT
Base Service
Foto A - 1
Foto A - 2
Tampak halaman site sebelum dibersihkan
Tampak halaman site setelah dibersihkan
Foto A - 3
Foto A - 4
Tampak tower bagian atas (tampak mounting & lampu halaman)
Tampak tower bagian bawah (tampak pedestal/kaki tower)
Foto A - 5
Foto A - 6
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Contractor
: NOKIA SIEMENS NETWORK
PREVENTIVE MAINTENANCE
PHOTO REPORT
Base Service
Foto B - 1
Foto B - 2
Status grounding - Tampak lightning rod (Splitzen)
Status grounding - Grounding ke Pagar
Foto B - 5
Foto B - 6
Pengukuran grounding - Grounding ke Pagar
Pengukuran grounding - Grounding ke kaki tower
Foto B - 3
Foto B - 4
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Contractor
: NOKIA SIEMENS NETWORK
PREVENTIVE MAINTENANCE
PHOTO REPORT
Base Service
Foto C - 1
Foto C - 2
Pengukuran grounding - Tangki genset (if any)
Pengukuran grounding - Box control
N/A
Tampak Access Lease Area
Site View - Tampak Atas (Sisi -1)
Foto C - 3
Foto C - 4
OBL - Berfungsi dengan baik
Yard Lamp - Berfungsi dengan baik
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Contractor
: NOKIA SIEMENS NETWORK
Site View - Tampak Atas (Sisi - 2)
Safety Tools (Safety belt, helm, sepatu, sarung tangan)
PREVENTIVE MAINTENANCE
PHOTO REPORT
Base Service
Foto D - 1
Foto D - 2
N/A
Foto D - 5
Foto D - 6
Foto D - 3
Foto D - 4
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: FLEXI
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Indoor
Foto A-1
Foto A-2
Tampak Bagian Luar Shelter
Tampak Bagian Dalam Shelter
Foto A-3
Foto A-4
Tampak Cable Tray
Tampak Lampu di dalam shelter
Foto A-6
Foto A-5
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: FLEXI
Tampak Grounding di dalam shelter
Tampak pondasi shelter
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Indoor
Foto B-1
Foto B-2
Foto B-5
Foto B-6
Tampak DC Fan
Tampak Smoke & Heat detector
Foto B-3
Foto B-4
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: FLEXI
Foto C-1
Foto C-2
Tampak AC Indoor
Tampak AC Outdoor
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Indoor
Pengukuran - Tekanan AC
Pengukuran - Temperature Shelter
Foto C-5
Foto C-6
Pengukuran - Tegangan R - N (Panel KWH)
Pengukuran - Tegangan S - N (Panel KWH)
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: FLEXI
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Indoor
Foto D-1
Foto D-2
Pengukuran - Tegangan T - N (Panel KWH)
Pengukuran - Tegangan R - S (Panel KWH)
Pengukuran - Tegangan G- N (Panel KWH)
Pengukuran - Tegangan R - N (Panel ACPDB)
Foto D-3
Foto D-4
Pengukuran - Tegangan S - T (Panel KWH)
Pengukuran - Tegangan R - T (Panel KWH)
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: FLEXI
Pengukuran - Tegangan S - N (Panel ACPDB)
Pengukuran - Tegangan T - N (Panel ACPDB)
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Indoor
Foto D-1
Foto D-2
Pengukuran - Tegangan R - T (Panel ACPDB)
Pengukuran - Tegangan G - N (Panel ACPDB)
Foto D-3
Foto D-4
Pengukuran - Tegangan R - S (Panel ACPDB)
Pengukuran - Tegangan S - T (Panel ACPDB)
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: FLEXI
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Indoor
Foto E-1
Foto E-2
Status grounding - Control Box
Status grounding - External Grounding Bar
Pengukuran grounding - External Grounding Bar
Pengukuran grounding - Internal Grounding Bar
Foto E-3
Foto E-4
Status grounding - Internal Grounding Bar
Pengukuran grounding - Control Box
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: FLEXI
Tampak Pole KWH Box
Kondisi KWH Panel (Keadaan tertutup)
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Indoor
Foto F-1
Foto F-2
Foto F-5
Foto F-6
Kondisi Segel pada Terminal KWH
Kondisi Segel pada KWH Meter Record
Foto F-3
Foto F-4
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: FLEXI
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Indoor
Foto G-1
Foto G-2
Kondisi segel pada MCB KWH meter
KWH meter record
Foto G-5
Foto G-6
Foto G-3
Foto G-4
Protelindo ID
: JAW-CJV-0004-D-P
Date
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: ISAT
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto A-1
Foto A-2
Tampak Kondisi Base Frame
Tampak Kondisi Dyna Bolt
: 06/03/2012
Pengukuran - Tegangan S - N (Panel KWH)
Pengukuran - Tegangan T - N (Panel KWH)
Foto A-3
Foto A-4
Tampak Pondasi Base Frame
Pengukuran - Tegangan R - N (Panel KWH)
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: ISAT
Pengukuran - Tegangan R - S (Panel KWH)
Pengukuran - Tegangan S - T (Panel KWH)
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto B-1
Foto B-2
Foto B-5
Foto B-6
Pengukuran - Tegangan R - N (Panel ACPDB)
Pengukuran - Tegangan S - N (Panel ACPDB)
Foto B-3
Foto B-4
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: ISAT
Foto C-1
Foto C-2
Pengukuran - Tegangan T - N (Panel ACPDB)
Pengukuran - Tegangan R - S (Panel ACPDB)
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Pengukuran - Tegangan S - T (Panel ACPDB)
Pengukuran - Tegangan R - T (Panel ACPDB)
Foto C-5
Foto C-6
Pengukuran - Tegangan G - N (Panel ACPDB)
Status grounding - Control Box
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: ISAT
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto D-1
Foto D-2
Status grounding - External Grounding Bar
Status grounding - Internal Grounding Bar
NA
Pengukuran grounding - Internal Grounding Bar
Tampak Pole KWH Box
Foto D-3
Foto D-4
Pengukuran grounding - Control Box
Pengukuran grounding - External Grounding Bar
Foto D-5
Foto D-6
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: ISAT
Kondisi KWH Panel (Keadaan tertutup)
Kondisi KWH Panel (Keadaan terbuka)
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto E-1
Foto E-2
Foto E-5
Foto E-6
Kondisi Segel pada KWH Meter Record
Kondisi segel pada MCB KWH meter
Foto E-3
Foto E-4
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: ISAT
Foto F-1
Foto F-2
KWH meter record
ID Pelanggan
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
N/A
Foto F-5
Foto F-6
Protelindo ID
: JAW-CJV-0004-D-P
Date
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: TSEL
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
: 06/03/2012
Foto A-1
Foto A-2
Tampak Kondisi Base Frame
Tampak Kondisi Dyna Bolt
Foto A-3
Foto A-4
Tampak Pondasi Base Frame
Pengukuran - Tegangan R - N (Panel KWH)
Foto A-6
Foto A-5
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: TSEL
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto B-1
Foto B-2
Pengukuran - Tegangan R - S (Panel KWH)
Pengukuran - Tegangan S - T (Panel KWH)
Foto B-3
Foto B-4
Pengukuran - Tegangan R - T (Panel KWH)
Pengukuran - Tegangan G- N (Panel KWH)
Foto B-5
Foto B-6
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: TSEL
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto C-1
Foto C-2
Pengukuran - Tegangan T - N (Panel ACPDB)
Pengukuran - Tegangan R - S (Panel ACPDB)
Foto C-3
Foto C-4
Pengukuran - Tegangan S - T (Panel ACPDB)
Pengukuran - Tegangan R - T (Panel ACPDB)
Foto C-5
Foto C-6
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: TSEL
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto D-1
Foto D-2
Status grounding - External Grounding Bar
Status grounding - Internal Grounding Bar
NA
Foto D-3
Foto D-4
Pengukuran grounding - Control Box
Pengukuran grounding - External Grounding Bar
Foto D-5
Foto D-6
Pengukuran grounding - Internal Grounding Bar
Tampak Pole KWH Box
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: TSEL
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto E-1
Foto E-2
Kondisi KWH Panel (Keadaan tertutup)
Kondisi KWH Panel (Keadaan terbuka)
Foto E-3
Foto E-4
Kondisi MCB KWH Meter
Kondisi Segel pada Terminal KWH
Foto E-5
Foto E-6
Protelindo ID
: JAW-CJV-0004-D-P
Date
: 06/03/2012
Protelindo Name
: TEMBALANG (SEMARANG)
Tenant
: TSEL
PREVENTIVE MAINTENANCE
PHOTO REPORT
Tenant
Outdoor
Foto F-1
Foto F-2
KWH meter record
ID Pelanggan
N/A
Foto F-3
Foto F-4