Protelindo Site ID

Protlindo Site Name

Date

Time WIB / WITA / WIT

Grounding Measurement : Ohm ( < 1 Ohm )

Grounding Well : Ohm ( < 1 Ohm )

Tower Leg : Ohm ( < 1 Ohm )

Fence : Ohm ( < 1 Ohm )

Genset Tank : Ohm ( < 1 Ohm )

Grounding Status :

Lightening Rod : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...

BAR grounding tower : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ………

BAR grounding well : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ………

Down conductor Cable : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ………

Bolt Connection : OK NOK Remark : ( uncompleted condition / stolen / broken / worse connection ), ………

Tower Type : SST Monopole Triangle Pole Mini Tower

Painting Condition : OK NOK Remark : ( tower loosen paint 70 % ), GALVANIS

Construction Condition : OK NOK Remark : ( paving down/ tower leg cracked ), ………….

Tower Cleaning : OK NOK Remark : ( cleaning from spider nest / bee / etc ), ………….

Tower Lamp / OBL : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….

Photo Sensor : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….

Base Service

CHECK LIST PREVENTIVE MAINTENANCE

MECHANICAL ELECTRICAL

: JAW-CJV-0004-D-P

: TEMBALANG (SEMARANG)

: 06/03/2012

: 10:18:00 AM

GROUNDING ………. ………. 0,33 0,36 N/A TOWER LIGHTING

Tower Lamp (OBL) Amount : 4 Unit

Yard Lamp Amount (Mercury & TL) : 1 Unit

Tower Lamp (OBL) Condition : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….

Yard Lamp Condition : OK NOK N/A Remark : ( broken, cracked, unshielded), ………….

Site Photo Sensor : OK NOK N/A Remark : ( sensor respon checking ), ………….

Yard Lamp Shield : OK NOK N/A Remark : ( lamp shield checking broken / no ), …….

Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), ………….

Site Cleaning : OK NOK Remark : ( cleaning for grass / garbage )………

Flume Cleaning : OK NOK Remark : ………

Paving Block or Gravel : OK NOK Remark : ………

Barbared Wire : OK NOK Remark : ………

Fence Door (Swing/Sliding) : OK NOK Remark : ………

ENVA Check Respons

Lightening Alarm : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Obstruction Light Failure : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Grounding System : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Fence Break : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

( HARI )

INSPECTION BY

LIGHTING

FENCE

ENVA STATUS

(2)

Protelindo Site ID Date

Protlindo Site Name Time WIB / WITA / WIT

Operator

Equipment Type : Indoor Outdoor AC Amount : 2 unit

AC Mark : Daikin National Others / PANASONIC 1,5 PK

Broken AC YES NO YES NO YES NO YES NO

Power 1,5 1,5

Pressure 70 70

Current Max Current Measurement

AC Indoor Condition OK NOK OK NOK OK NOK OK NOK

Pipe Condition OK NOK OK NOK OK NOK OK NOK

Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A

Switch Contactor OK NOK OK NOK OK NOK OK NOK

AC Temperature Setting OK NOK OK NOK OK NOK OK NOK

Room Temperature :

Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK

Shelter Roof : OK NOK N/A Remark : ( leak, broken ), ………….

Dinding Shelter : OK NOK N/A Remark : ( cracked, leak, broken ), ………….

Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), ………….

Room Cleaning : OK NOK Leak Remark : ………

Roof Cleaning : OK NOK Leak Remark : ………

Benzoic Spreading : OK NOK Remark : ( cleaning for grass / garbage )………

Door Hinge Lubrication : OK NOK Remark : ………

Shelter Foundation : OK NOK Remark : ………

Heat Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

6,72 8,28

Tenant

CHECK LIST PREVENTIVE MAINTENANCE

MECHANICAL ELECTRICAL

: JAW-CJV-0004-D-P : 06/03/2012

: TEMBALANG (SEMARANG) : 10:18:00 AM

: FLEXI AIR CONDITIONER

Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4

AC Status PK Psi According with data signed at

AC Outdoor

Ampere Leak / Not Leak Leak / Not Leak Operation test switch < 24 o

C 20,7 EXHAUST FAN SHELTER Alarm System GROUNDING

Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...

Control Box : Ohm ( < 1 Ohm )

External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm )

Base Frame Condition : OK NOK N/A Remark : ... Dynabolt Condition : OK NOK N/A Remark : ... Base Frame Foundation : OK NOK N/A Remark : ...

Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) : V

Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record :

AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition )

COS : OK NOK N/A Remark : ( clean, neat, broken )

PLN Power Supplied : kVA

MCB input :

MCB Condition : OK NOK NA

1 Phase : A pcs

3 Phases : A pcs

COS : A

PLN ID :

Seal

KWH Record : OK NOK NA ( Good Sealed ), ………..……

Terminal / OKA : OK NOK NA ( Good Sealed ), ………..……

MCB : OK NOK NA ( Good Sealed ), ………..……

MCB in the KWH 'ON' Position

A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..…… B. R, S & T Indicator Lamps are lit : OK NOK NA

MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..……

KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……

211 0 378 Measurement 0,39 0,37 0,53 OUTDOOR TYPE

KWH ELECTRICAL MEASUREMENT

217 371

216 373

35037 ELECTRICAL VISUAL CHECK

PLN VISUAL CHECK

52-3040397908

PLN FUNCTION TEST

PT NOKIA SIEMENS NETWORK

INSPECTION BY

23

……… ………

35 3

40

(3)

Protelindo Site ID Date

Protlindo Site Name Time WIB / WITA / WIT

Operator

Equipment Type : Indoor Outdoor AC Amount : …………. unit

AC Mark : Daikin National Others / ………..

Broken AC YES NO YES NO YES NO YES NO

Power Pressure Current Max Current Measurement

AC Indoor Condition OK NOK OK NOK OK NOK OK NOK

Pipe Condition OK NOK OK NOK OK NOK OK NOK

Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A

Switch Contactor OK NOK OK NOK OK NOK OK NOK

AC Temperature Setting OK NOK OK NOK OK NOK OK NOK

Room Temperature :

Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK

Shelter Roof : OK NOK N/A Remark : ( leak, broken ), ………….

Dinding Shelter : OK NOK N/A Remark : ( cracked, leak, broken ), ………….

Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), ………….

Room Cleaning : OK NOK Leak Remark : ………

Roof Cleaning : OK NOK Leak Remark : ………

Benzoic Spreading : OK NOK Remark : ( cleaning for grass / garbage )………

Door Hinge Lubrication : OK NOK Remark : ………

Shelter Foundation : OK NOK Remark : ………

Heat Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Tenant

CHECK LIST PREVENTIVE MAINTENANCE

MECHANICAL ELECTRICAL

: JAW-CJV-0004-D-P : 06/03/2012

: TEMBALANG (SEMARANG) : 10:18:00 AM

: ISAT AIR CONDITIONER

Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4

AC Status PK Psi According with data signed at

AC Outdoor

Ampere Leak / Not Leak Leak / Not Leak Operation test switch < 24 o

C

EXHAUST FAN

SHELTER

Alarm System

GROUNDING

Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...

Control Box : Ohm ( < 1 Ohm )

External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm )

Base Frame Condition : OK NOK N/A Remark : ... Dynabolt Condition : OK NOK N/A Remark : ... Base Frame Foundation : OK NOK N/A Remark : ...

Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) : V

Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record :

AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition )

COS : OK NOK N/A Remark : ( clean, neat, broken )

PLN Power Supplied : kVA

MCB input :

MCB Condition : OK NOK NA

1 Phase : A pcs

3 Phases : A pcs

COS : A

PLN ID :

Seal

KWH Record : OK NOK NA ( Good Sealed ), ………..……

Terminal / OKA : OK NOK NA ( Good Sealed ), ………..……

MCB : OK NOK NA ( Good Sealed ), ………..……

MCB in the KWH 'ON' Position

A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..…… B. R, S & T Indicator Lamps are lit : OK NOK NA

MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..……

KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……

Measurement

0,37 -N/A

OUTDOOR TYPE

KWH ELECTRICAL MEASUREMENT

212 0

212 0

212 0

0 2472

ELECTRICAL VISUAL CHECK

PLN VISUAL CHECK

N/A

PLN FUNCTION TEST

PT NOKIA SIEMENS NETWORK

INSPECTION BY

7,7

35 1

……… …………..

40

(4)

Protelindo Site ID Date

Protlindo Site Name Time WIB / WITA / WIT

Operator

Equipment Type : Indoor Outdoor AC Amount : …………. unit

AC Mark : Daikin National Others / ………..

Broken AC YES NO YES NO YES NO YES NO

Power Pressure Current Max Current Measurement

AC Indoor Condition OK NOK OK NOK OK NOK OK NOK

Pipe Condition OK NOK OK NOK OK NOK OK NOK

Auto Restart OK NOK N/A OK NOK N/A OK NOK N/A OK NOK N/A

Switch Contactor OK NOK OK NOK OK NOK OK NOK

AC Temperature Setting OK NOK OK NOK OK NOK OK NOK

Room Temperature :

Exhaust Fan Condition : OK NOK Exhaust Fan Cleaning : OK NOK

Shelter Roof : OK NOK N/A Remark : ( leak, broken ), ………….

Dinding Shelter : OK NOK N/A Remark : ( cracked, leak, broken ), ………….

Fence Condition : OK NOK N/A Remark : ( collapsed, broken ), ………….

Room Cleaning : OK NOK Leak Remark : ………

Roof Cleaning : OK NOK Leak Remark : ………

Benzoic Spreading : OK NOK Remark : ( cleaning for grass / garbage )………

Door Hinge Lubrication : OK NOK Remark : ………

Shelter Foundation : OK NOK Remark : ………

Heat Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Smoke Detector : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Ring Bell : OK NOK N/A Remark : ( uninstalled, undetected ), ………….

Tenant

CHECK LIST PREVENTIVE MAINTENANCE

MECHANICAL ELECTRICAL

: JAW-CJV-0004-D-P : 06/03/2012

: TEMBALANG (SEMARANG) : 10:18:00 AM

: TSEL AIR CONDITIONER

Measurement Remark AC # 1 AC # 2 AC # 3 AC # 4

AC Status PK Psi According with data signed at

AC Outdoor

Ampere Leak / Not Leak Leak / Not Leak Operation test switch < 24 o

C

EXHAUST FAN

SHELTER

Alarm System

GROUNDING

Grounding Status : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), …… ...

Control Box : Ohm ( < 1 Ohm )

External Grounding Bar : Ohm ( < 1 Ohm ) Internal Grounding Bar : Ohm ( < 1 Ohm )

Base Frame Condition : OK NOK N/A Remark : ... Dynabolt Condition : OK NOK N/A Remark : ... Base Frame Foundation : OK NOK N/A Remark : ...

Phase Voltage R - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage S - T (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage S - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage T - R (350V - 400V) : V 380 V +/- 5% max 10 V Phase Voltage T - N (200V - 240V) : V 220 V +/- 5% max 10 V Phase Voltage G - N (< 5 V) : V

Phase Voltage R - S (350V - 400V) : V 380 V +/- 5% max 10 V KWH Meter Record :

AC-PDB : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection ), ……… KWH Box Including Pole KWH : OK NOK N/A Remark : ( uncompleted condition / stolen / broken / worse connection / pole Condition )

COS : OK NOK N/A Remark : ( clean, neat, broken )

PLN Power Supplied : kVA

MCB input :

MCB Condition : OK NOK NA

1 Phase : A pcs

3 Phases : A pcs

COS : A

PLN ID :

Seal

KWH Record : OK NOK NA ( Good Sealed ), ………..……

Terminal / OKA : OK NOK NA ( Good Sealed ), ………..……

MCB : OK NOK NA ( Good Sealed ), ………..……

MCB in the KWH 'ON' Position

A. Current flows to the MCCB for Devices : OK NOK NA ( Current Measurement result = Visual check ), ………..…… B. R, S & T Indicator Lamps are lit : OK NOK NA

MCB for Devices to 'ON' Position : OK NOK NA ( MCB In position ), ………..……

KWH Meter Spin Normally : OK NOK NA ( Spin Normally ), ………..……

Measurement

0,33 0,42 N/A

OUTDOOR TYPE

KWH ELECTRICAL MEASUREMENT

212 0

213 0

212 0

0 1311

ELECTRICAL VISUAL CHECK

PLN VISUAL CHECK

N/A

PLN FUNCTION TEST

PT NOKIA SIEMENS NETWORK

INSPECTION BY

7,7

16 2

……… ………

40

(5)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Contractor

: NOKIA SIEMENS NETWORK

PREVENTIVE MAINTENANCE

PHOTO REPORT

Base Service

Foto A - 1

Foto A - 2

Tampak halaman site sebelum dibersihkan

Tampak halaman site setelah dibersihkan

Foto A - 3

Foto A - 4

Tampak tower bagian atas (tampak mounting & lampu halaman)

Tampak tower bagian bawah (tampak pedestal/kaki tower)

Foto A - 5

Foto A - 6

(6)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Contractor

: NOKIA SIEMENS NETWORK

PREVENTIVE MAINTENANCE

PHOTO REPORT

Base Service

Foto B - 1

Foto B - 2

Status grounding - Tampak lightning rod (Splitzen)

Status grounding - Grounding ke Pagar

Foto B - 5

Foto B - 6

Pengukuran grounding - Grounding ke Pagar

Pengukuran grounding - Grounding ke kaki tower

Foto B - 3

Foto B - 4

(7)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Contractor

: NOKIA SIEMENS NETWORK

PREVENTIVE MAINTENANCE

PHOTO REPORT

Base Service

Foto C - 1

Foto C - 2

Pengukuran grounding - Tangki genset (if any)

Pengukuran grounding - Box control

N/A

Tampak Access Lease Area

Site View - Tampak Atas (Sisi -1)

Foto C - 3

Foto C - 4

OBL - Berfungsi dengan baik

Yard Lamp - Berfungsi dengan baik

(8)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Contractor

: NOKIA SIEMENS NETWORK

Site View - Tampak Atas (Sisi - 2)

Safety Tools (Safety belt, helm, sepatu, sarung tangan)

PREVENTIVE MAINTENANCE

PHOTO REPORT

Base Service

Foto D - 1

Foto D - 2

N/A

Foto D - 5

Foto D - 6

Foto D - 3

Foto D - 4

(9)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: FLEXI

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Indoor

Foto A-1

Foto A-2

Tampak Bagian Luar Shelter

Tampak Bagian Dalam Shelter

Foto A-3

Foto A-4

Tampak Cable Tray

Tampak Lampu di dalam shelter

Foto A-6

Foto A-5

(10)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: FLEXI

Tampak Grounding di dalam shelter

Tampak pondasi shelter

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Indoor

Foto B-1

Foto B-2

Foto B-5

Foto B-6

Tampak DC Fan

Tampak Smoke & Heat detector

Foto B-3

Foto B-4

(11)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: FLEXI

Foto C-1

Foto C-2

Tampak AC Indoor

Tampak AC Outdoor

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Indoor

Pengukuran - Tekanan AC

Pengukuran - Temperature Shelter

Foto C-5

Foto C-6

Pengukuran - Tegangan R - N (Panel KWH)

Pengukuran - Tegangan S - N (Panel KWH)

(12)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: FLEXI

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Indoor

Foto D-1

Foto D-2

Pengukuran - Tegangan T - N (Panel KWH)

Pengukuran - Tegangan R - S (Panel KWH)

Pengukuran - Tegangan G- N (Panel KWH)

Pengukuran - Tegangan R - N (Panel ACPDB)

Foto D-3

Foto D-4

Pengukuran - Tegangan S - T (Panel KWH)

Pengukuran - Tegangan R - T (Panel KWH)

(13)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: FLEXI

Pengukuran - Tegangan S - N (Panel ACPDB)

Pengukuran - Tegangan T - N (Panel ACPDB)

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Indoor

Foto D-1

Foto D-2

Pengukuran - Tegangan R - T (Panel ACPDB)

Pengukuran - Tegangan G - N (Panel ACPDB)

Foto D-3

Foto D-4

Pengukuran - Tegangan R - S (Panel ACPDB)

Pengukuran - Tegangan S - T (Panel ACPDB)

(14)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: FLEXI

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Indoor

Foto E-1

Foto E-2

Status grounding - Control Box

Status grounding - External Grounding Bar

Pengukuran grounding - External Grounding Bar

Pengukuran grounding - Internal Grounding Bar

Foto E-3

Foto E-4

Status grounding - Internal Grounding Bar

Pengukuran grounding - Control Box

(15)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: FLEXI

Tampak Pole KWH Box

Kondisi KWH Panel (Keadaan tertutup)

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Indoor

Foto F-1

Foto F-2

Foto F-5

Foto F-6

Kondisi Segel pada Terminal KWH

Kondisi Segel pada KWH Meter Record

Foto F-3

Foto F-4

(16)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: FLEXI

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Indoor

Foto G-1

Foto G-2

Kondisi segel pada MCB KWH meter

KWH meter record

Foto G-5

Foto G-6

Foto G-3

Foto G-4

(17)

Protelindo ID

: JAW-CJV-0004-D-P

Date

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: ISAT

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto A-1

Foto A-2

Tampak Kondisi Base Frame

Tampak Kondisi Dyna Bolt

: 06/03/2012

Pengukuran - Tegangan S - N (Panel KWH)

Pengukuran - Tegangan T - N (Panel KWH)

Foto A-3

Foto A-4

Tampak Pondasi Base Frame

Pengukuran - Tegangan R - N (Panel KWH)

(18)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: ISAT

Pengukuran - Tegangan R - S (Panel KWH)

Pengukuran - Tegangan S - T (Panel KWH)

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto B-1

Foto B-2

Foto B-5

Foto B-6

Pengukuran - Tegangan R - N (Panel ACPDB)

Pengukuran - Tegangan S - N (Panel ACPDB)

Foto B-3

Foto B-4

(19)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: ISAT

Foto C-1

Foto C-2

Pengukuran - Tegangan T - N (Panel ACPDB)

Pengukuran - Tegangan R - S (Panel ACPDB)

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Pengukuran - Tegangan S - T (Panel ACPDB)

Pengukuran - Tegangan R - T (Panel ACPDB)

Foto C-5

Foto C-6

Pengukuran - Tegangan G - N (Panel ACPDB)

Status grounding - Control Box

(20)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: ISAT

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto D-1

Foto D-2

Status grounding - External Grounding Bar

Status grounding - Internal Grounding Bar

NA

Pengukuran grounding - Internal Grounding Bar

Tampak Pole KWH Box

Foto D-3

Foto D-4

Pengukuran grounding - Control Box

Pengukuran grounding - External Grounding Bar

Foto D-5

Foto D-6

(21)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: ISAT

Kondisi KWH Panel (Keadaan tertutup)

Kondisi KWH Panel (Keadaan terbuka)

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto E-1

Foto E-2

Foto E-5

Foto E-6

Kondisi Segel pada KWH Meter Record

Kondisi segel pada MCB KWH meter

Foto E-3

Foto E-4

(22)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: ISAT

Foto F-1

Foto F-2

KWH meter record

ID Pelanggan

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

N/A

Foto F-5

Foto F-6

(23)

Protelindo ID

: JAW-CJV-0004-D-P

Date

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: TSEL

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

: 06/03/2012

Foto A-1

Foto A-2

Tampak Kondisi Base Frame

Tampak Kondisi Dyna Bolt

Foto A-3

Foto A-4

Tampak Pondasi Base Frame

Pengukuran - Tegangan R - N (Panel KWH)

Foto A-6

Foto A-5

(24)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: TSEL

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto B-1

Foto B-2

Pengukuran - Tegangan R - S (Panel KWH)

Pengukuran - Tegangan S - T (Panel KWH)

Foto B-3

Foto B-4

Pengukuran - Tegangan R - T (Panel KWH)

Pengukuran - Tegangan G- N (Panel KWH)

Foto B-5

Foto B-6

(25)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: TSEL

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto C-1

Foto C-2

Pengukuran - Tegangan T - N (Panel ACPDB)

Pengukuran - Tegangan R - S (Panel ACPDB)

Foto C-3

Foto C-4

Pengukuran - Tegangan S - T (Panel ACPDB)

Pengukuran - Tegangan R - T (Panel ACPDB)

Foto C-5

Foto C-6

(26)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: TSEL

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto D-1

Foto D-2

Status grounding - External Grounding Bar

Status grounding - Internal Grounding Bar

NA

Foto D-3

Foto D-4

Pengukuran grounding - Control Box

Pengukuran grounding - External Grounding Bar

Foto D-5

Foto D-6

Pengukuran grounding - Internal Grounding Bar

Tampak Pole KWH Box

(27)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: TSEL

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto E-1

Foto E-2

Kondisi KWH Panel (Keadaan tertutup)

Kondisi KWH Panel (Keadaan terbuka)

Foto E-3

Foto E-4

Kondisi MCB KWH Meter

Kondisi Segel pada Terminal KWH

Foto E-5

Foto E-6

(28)

Protelindo ID

: JAW-CJV-0004-D-P

Date

: 06/03/2012

Protelindo Name

: TEMBALANG (SEMARANG)

Tenant

: TSEL

PREVENTIVE MAINTENANCE

PHOTO REPORT

Tenant

Outdoor

Foto F-1

Foto F-2

KWH meter record

ID Pelanggan

N/A

Foto F-3

Foto F-4

Referensi

Dokumen terkait