Lampiran 1. Flowchart Penelitian
Mulai
Pengukuran Debit Saluran
Menghitung Efisiensi Saluran
Pengukuran Kehilangan Air Pada
Saluran
Merancang Saluran Menghitung Kecepatan
Aliran Rata-Rata dan Kecepatan Aliran Kritis
Data
Analisis Data
Lampiran 2. Perhitungan Bulk Density, Particle Density dan Porositas
BTKO = Berat tanah kering oven (massa tanah kering)
Volume total = volume ring sample = 1
4πd
Kerapatan Massa (Bulk Density)
Kerapatan Partikel (particle Density)
Dalam Saluran
Berat Tanah = 177,73 gr
Volume Tanah = 150 ml
Volume Air = 350 ml
Volume Air Tanah = 410 ml
Pd =
berat tanah
(volume tanah - volume pori)
Volume Ruang Pori = (volume air + volume tanah) - volume air tanah
Volume Ruang Pori = (350 ml + 150 ml) – 410 ml
= 90 ml
Pd = 177,73
(150 - 90) gr/cm 3
= 2,96 gr/cm3 Tepi Saluran
Berat Tanah = 135,10 gr
Volume Tanah = 108 ml
Volume Air = 350 ml
Volume Air Tanah = 400 ml
Pd =
berat tanah
(volume tanah - volume pori)
Volume Ruang Pori = (volume air + volume tanah) - volume air tanah
Volume Ruang Pori = (350 ml + 108 ml) – 400ml
= 58 ml
Pd = 135,10
108 - 58 gr/cm 3
Porositas
Dasar Saluran
Porositas = (1-Bd
Pd ) x 100 %
= (1-0,92
2,96 ) x 100 %
= 69 %
Tepi Saluran
Porositas = (1-Bd
Pd ) x 100 %
= (1-0,70
2,70 ) x 100 %
= 74 %
Saluran 2
Kerapatan Massa (Bulk Density)
Dalam Saluran
Ms = 170,76 gr
Bd = Ms Vt
= 170,76
192,325 gr/cm 3
= 0,89 gr/cm3
Tepi Saluran
Ms = 128,95 gr
Bd = Ms Vt
= 128,95
192,325 gr/cm 3
= 0,67 gr/cm3
Kerapatan Partikel (particle Density)
Dasar Saluran
Volume Tanah = 146 ml
Volume Air = 350 ml
Volume Air Tanah = 408 ml
Pd =
berat tanah
(volume tanah-volume pori)
Volume Ruang Pori = (volume air + volume tanah) - volume air tanah
Volume Ruang Pori = (350 ml + 146 ml) – 408ml
= 88 ml
Pd = 170,76
(146 - 88) gr/cm 3
= 2,94 gr/cm3 Tepi Saluran
Berat Tanah = 128,95 gr
Volume Tanah = 105 ml
Volume Air = 350 ml
Volume Air Tanah = 395 ml
Pd =
berat tanah
(volume tanah - volume pori)
Volume Ruang Pori = (volume air + volume tanah) - volume air tanah
Volume Ruang Pori = (350 ml + 105 ml) – 395 ml
= 60 ml
Pd = 128,95
105 - 60 gr/cm 3
= 2,87 gr/cm3 Porositas
Dasar Saluran
Porositas = (1- Bd
= (1- 0,89
2,94 ) x 100 %
= 70 %
Tepi Saluran
Porositas = (1-Bd
Pd ) x 100 %
= (1-0,67
2,87 ) x 100 %
= 77 %
Lampiran 3. Perhitungan Debit Pada Saluran 1 dan Saluran 2
Lokasi Jarak Pengukuran
(m)
Debit (l/det)
Hulu Hilir
Saluran I 45 8,25 6,05
Saluran II 35 9,76 7,32
Saluran I 35 8,25 6,92
Saluran I (Hulu)
a. Cara Tampung
Waktu (t) (det)
Volume (V) (l)
Debit (Q) (l/det)
1,0 7,95 7,95
Q = V
t
= 7,95
1 l/det
= 7,95 l/det
b. Sekat Ukur Thompson
h = 12,9 cm
Q = 0,0138 h5 2⁄
= 0,0138 (12,9)5 2⁄
= 8,25 l/det
Saluran I (Hilir)
a. Cara Tampung
Waktu (t) (det)
Volume (V) (l)
Debit (Q) (l/det)
1,3 7,4 5,69
Q = V
t
= 7,4
1,3 l/det
= 5,69 l/det
b. Sekat ukur Thompson
h = 11,4 cm
Q = 0,0138 h5 2⁄
=0,0138 (11,4)5 2⁄
= 6,05 l/det
Q� = 8,25 + 6,05
2 =7,15 l/det
Saluran II (Hulu)
a. Cara Tampung
Waktu (t) (det)
Volume (V) (l)
Debit (Q) (l/det)
1,1 9,85 8,95
Q = V t
= 9,85
1,1 l/det
= 8,95 l/det
h = 13,8 cm
Q = 0,0138 h5 2⁄
= 0,0138 (13,8)5 2⁄
= 9,76 l/det
Saluran II (hilir)
a. Cara Tampung
Waktu (t) (det)
Volume (V) (l)
Debit (Q) (l/det)
1,1 7650 6,95
Q = V
t
= 7650
1,1 l/det
= 6,95 l/det
b. Sekat Ukur Thompson
h = 12,3 cm
Q =0,0138 h5 2⁄
=0,0138 (12,3)5 2⁄
= 7,32 l/det
Q� = 9,76 + 7,32
2 =8,54 l/det
Lampiran 4. Ukuran Saluran Tersier
Saluran I
Kedalaman = (19,5 cm + 16 cm + 15,5 cm)
3
Lebar = (75 cm + 62 cm + 82cm)
Lampiran 5. Perhitungan Kehilangan Air
No Lokasi
Saluran I (pada jarak pengukuran 45 m)
Penurunan debit = (8,25 – 6,05) l/det
Saluran II (pada jarak pengukuran 35 m)
Penurunan debit = (9,76 – 7,32) l/det
= 2,44 l/det
= 2,44 x 10-3 m3/det A = panjang x lebar
= 35 m x 0,74 m
= 25,90 m2
Maka jumlah air yang hilang = 2,44 ×10 -3
m3 det� 25,90 m2
= 0,0942 x 10-3 m/det
= 0,0942 mm/det x 24 jam/hari x 3600 det/jam
= 8138,88 mm/hari
Jika jarak pengukuran sama (35 m) maka kehilangan air pada saluran dua
yaitu:
Jumlah air yang hilang = �5788,8 mm/hari
45 m �× 35 m
= 4502,4 mm/hari
= 1,33 l/det
Sehingga debit hilir = (8,25 – 1,33) l/det = 6,92 l/det
Evapotranspirasi
Saluran I dan II
Kc Rumput = 0,85
Tempertur (t) = 26,86 oC Lama Penyinaran Matahari (P) = 3,8
K=Kt×Kc
Kt=0,0311 t+0,240
=0,0311 (26,86) + 0,240
=1,08
K=1,08 ×0,85
= 0,92
U = 0,92 × 3,8 (45,7 (26,86) + 813) 100
= 7133,59
100
= 71,34 mm/bulan
= 2,38 mm/hari
Perkolasi
Saluran I
Ulangan Penurunan air (mm)
I 55
II 80
III 50
Rata-rata 61,7
Silinder 1
h1 = 16 cm
h2 = 10,5 cm
P1 = h1-h2
t1-t2
mm/hari
P1 =
(16 cm – 10,5 cm) 1 hari
P1 = 5,5 cm/hari
Silinder 2
h1 = 18 cm
h2 = 10 cm
P2 = h1-h2
t1-t2
mm/hari
P2 =
(18 cm – 10 cm) 1 hari
P2 = 8 cm/hari
= 80 mm/hari
Silinder 3
h1 = 16 cm
h2 = 11 cm
P3 = h1-h2
t1-t2 mm/hari
P3 = �
16 cm - 11 cm� 1 hari
P3 = 5 cm/hari = 50 mm/hari
Perkolasi Rata-rata = P1 + P2 + P3
3
= (55 + 80 + 50) mm/hari
3
= 61,7 mm/hari
Saluran II
Ulangan Penurunan air (mm)
I 60
II 85
III 70
Rata-rata 71,7
Silinder 1
h1 = 18 cm
P1 = h1-h2
t1-t2
mm/hari
P1 =
(18 cm–12 cm) 1 hari
P1 = 6 cm/hari
= 60 mm/hari
Silinder 2
h1 = 20,5 cm
h2 = 12 cm
P2 = h1-h2
t1-t2 mm/hari
P2 =
(20,5 cm – 12 cm) 1 hari
P2 = 8,5 cm/hari
= 85 mm/hari
Silinder 3
h1 = 18,5 cm
h2 = 11,5 cm
P3 = h1-h2
t1-t2
mm/hari
P3 =
(18,5 cm – 11,5 cm) 1 hari
P3 = 7 cm/hari = 70 mm/hari
Perkolasi Rata-rata = P1+P2+P3
3
= (60 + 85 + 70) mm/hari
3
= 71,7 mm/hari
Saluran I (jarak pengukuran 45 m)
Rembesan = Kehilangan air di saluran – (Evapotranspirasi + Perkolasi)
= 5788,8 mm/hari – (2,38 mm/hari + 61,7 mm/hari)
= 5724,72 mm/hari
Saluran II (jarak pengukuran 35 m)
Rembesan = Kehilangan air di saluran – (Evapotranspirasi + Perkolasi)
= 8138,88 mm/hari – (2,38 mm/hari + 71,7 mm/hari)
= 8064,8 mm/hari
Saluran I (jarak pengukuran 35 m)
Rembesan = Kehilangan air di saluran – (Evapotranspirasi + Perkolasi)
= 4502,4 mm/hari – (2,38 mm/hari + 61,7 mm/hari)
= 4438,32 mm/hari
Lampiran 6. Perhitungan Efisiensi Saluran
Saluran I (pada jarak pengukuran 45 m)
Ee = Qhilir
Qhulu×100%
= 6,05
8,25×100%
= 73,33 %
Saluran II (pada jarak pengukuran 35 m)
Ee = Qhilir
Qhulu×100%
= 7,32
9,76×100 %
= 75 %
Jika jarak pengukurannya 35 m maka efisiensi penyaluran pada saluran I yaitu:
Ee = Qhilir
Ee = 6,92
8,25×100 %
= 83,88 %
Lampiran 7. Perhitungan Kemiringan Pada Saluran 1 dan Saluran 2
Saluran 1
Jarak (m) Beda tinggi (cm)
0 – 5 10
5 – 10 3,4
10 – 15 5,5
15 – 20 2,3
20 – 25 12
25-30 2
Jumlah 35,2
Kemiringan = 0,352 m
30 m ×100%
= 1,17 %
Saluran 2
Panjang (m) Beda tinggi (cm)
0 – 5 16
5-10 6,1
10-15 7,1
15-20 1
20-25 15,5
25-30 15,6
Jumlah 61,3
Kemiringan = 0,613 m
30 m ×100 %
= 2,04 %
Lampiran 8. Perhitungan Kecepatan Rata-Rata
Saluran I
V = Q
A
= 7,15 x 10 -3 m3/s
(0,17 m x 0,73 m)
Saluran II
V = Q
A
= 8,54 x 10−3 m3/s (0,24 m x 0,74 m)
= 0,048 m/s
Lampiran 9. Perhitungan Kecepatan Kritis
Saluran I
D = 0,17 m
V0= 0,546 D0,64
= 0,546 (0,17)0,64
= 0,18 m/s
Saluran II
D = 0,24 m
V0= 0,546 D0,64
= 0,546 (0,24)0,64
= 0,22 m/s
Lampiran 10. Perhitungan Rancangan Saluran
Saluran I
• Jika V = V0 , lebar dan dalam saluran di lapangan
V = Vo = 0,18
B = 0,73 m
D = 0,17 m
V = 1 NR
2 3⁄ S1 2⁄
0,36 = 2D
D = 0,18 m = 18 cm
B = 2 x 0,18 m = 0,36 m = 36 cm
• Jika V = V0 , kemiringan 0,04 %, lebar saluran di lapangan
V = Vo = 0,18
B = 0,73 m
S = 0,0004
V = 1
N R
2 3⁄
S1 2⁄
0,18 = 1 0,0225�
B×D B+2D�
2 3⁄
(S)1 2⁄
0,18 = 44,44 � 0,73D 0,73+2D�
2 3⁄
(0,0004)1 2⁄
0,18 = 0,89 × � 0,73D 0,73+2D�
2 3⁄
0,20 = � 0,693D
0,693+2D� 2 3⁄
0,089 = 0,73D
0,73+2D
0,065 + 0,178 D = 0,73 D
0,065 = 0,552 D
D = 0,12 m = 12 cm
Saluran II
• Jika V = V0 , lebar dan dalam saluran di lapangan
V = Vo = 0,22
B = 0,74
B = 0,96 m
= 96 cm
• Jika V = V0 , kemiringan 0,02 %, lebar saluran di lapangan
V = Vo = 0,22
B = 0,74 m
S = 0,0002
V = 1
N R
2 3⁄
S1 2⁄
0,22 = 1
0,0225� B×D B+2D�
2 3⁄
(S)1 2⁄
0,22 = 44,44 � 0,74D
0,74+2D� 2 3⁄
(0,0002)1 2⁄
0,22 = 0,6284 × � 0,74D 0,74+2D�
2 3⁄
0,35 = � 0,74D
0,74+2D� 2 3⁄
0,21 = 0,74D
0,74+2D
0,1554 + 0,42 D = 0,74 D
0,1554 = 0,32 D
D = 0,49 m
= 49 cm
• Jika V = V0 , kemiringan 0,02 %, B = 2D
V = Vo = 0,22
S = 0,0002
V = 1 N R
Lampiran 11. Gambar
Gambar 1. Saluran Sekunder
Gambar 2. Bangunan Pembagi ke Saluran Tersier
Gambar 4. Saluran Tersier 2
Gambar 5. Pengukuran Perkolasi