LED Display Tables for Selection Options

4.3 Statistics Functions/Diagnostics

4.3.2 LED Display Tables for Selection Options

(watch the LED display). Pressing the AzGrH button for a longer time (> 1 s ≤ 3 s) will bring you back to the object selection menu.

If the AzGrH button is pressed for more than 3 s, the system quits the statistics selection function and the display on the STEU board returns to 'normal'.

the objects CH, TVDS, block info and system info are listed in the table "Meaning of statistics function types".

The respective LED display is selected with the help of the table "Statistics function options". The table "Meaning after selection of statistics function type 2 - operating state" is relevant only to statistics function type "Operating state"

(function type 2; TVDS table only). See also Section 4.3.3 "Examples of Option Selection", page 47.

You want to display the statistical information for the object CH:

LED no. LED display: ! = on, Ο = off

1 ● ○ ○ ○ ○

2 ○ ● ○ ○ ○

3 ○ ○ ● ○ ○

4 ○ ○ ○ ● ○

5 ○ ○ ○ ○ ●

CH selected 1 2 3 4 5

Table 1 Object selection - CH

The upper LED group (LED 1 to LED 5) displays which CH object has been selected (CH 1 to CH 5).

You want to display the statistical information for the object TVDS:

LED no. LED display: ! = on, Ο = off

1 ● ○ ○ ○

2 ○ ● ○ ○

3 ○ ○ ● ○

4 ○ ○ ○ ●

5 ● ● ● ●

TVDS

selected 1 2 3 4

Table 2 Object selection – TVDS

The upper LED group (LED 1 to LED 5) displays which TVDS has been selected (TVDS 1 to TVDS 4). This indication is based on a combination of two LEDs being on.

You want to display the statistical information for the object Block info:

LED no. LED display: ! = on, Ο = off

1

2

3

4

5

Block info selected

Table 3 Object selection – Block info

The upper LED group (LED 1 to LED 5) displays which item of block information has been selected. This indication is based on a combination of more than one LED being on.

You want to display the statistical information for the object System info:

LED no. LED display: ! = on, Ο = off

1

2

3

4

5

System info selected

Table 4 Object selection – System info

The upper LED group (LED 1 to LED 5) displays which item of system

information has been selected. This indication is based on a combination of more than one LED being on.

The respective LED display is selected with the help of the table "Statistics function options" (table refers to object types CH, TVDS, block info and system info):

LED no. LED display: ! = on, Ο = off

7 ● ○ ● ○ ● ○ ● ○ ● ○ ● ○

8 ○ ● ● ○ ○ ● ● ○ ○ ● ● ○

9 ○ ○ ○ ● ● ● ● ○ ○ ○ ○ ●

10 ○ ○ ○ ○ ○ ○ ○ ● ● ● ● ●

11 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Function type selected

1 2 3 4 5 6 7 8 9 10 11 12

Table 5 Statistics function options (CH, TVDS, block info, system info)

The lower LED group (LED 7 to LED 11) on the right STEU 2 board displays the statistics function type which has been selected. This indication is based on one LED or more LEDs being on.

The description of the statistics function types for the object CH can be found in the following table:

Function

type Description of function type (for CH)

1 Current axle count of counting head selected since last system start-up. The system carries out a signed addition of the axles traversing the counting head (+1 for axles from left to right, -1 for axles from right to left).

2 Fault count of counting head selected 3 Bit 0 ... 7:

Bit 8:

Time elapsed since last pulse detection by CH (*0.07 s) Count monitoring fault

4 Total number of axles since last system start-up, bits 0 ... 11 5 Total number of axles since last system start-up, bits 12 ... 23 6 Total number of axles since last system start-up, bits 24 ... 31 7 Total number of trains since last system start-up, bits 0 ... 11 8 Total number of trains since last system start-up, bits 12 ... 23 9 Total number of suppressed faults since last system start-up 10 Total number of short trains (< 13 ms) since last system start-up 11 Total number of power supply failures since last system start-up

12 Total number of changes in channel state (G and X transitions) since last system start-up

Table 6 Description of statistics function types for counting head

The description of the statistics function types for the object TVDS can be found in the following table:

Function

type Description of function type (for TVDS)

1 Current axle count of track vacancy detection section selected since last system start-up. The system carries out a signed addition of the axles traversing the counting head (+1 for axles from left to right, -1 for axles from right to left).

2 Operating state (additional information for normal display) Restriction register XDEINS:

3

Bit 0:

Bit 1:

Reset restriction (ZGREIN) AzGrT not effective (ZAZGSP) Monitoring register XDUEBE:

4

Bit 3:

Bit 5:

Bit 7:

Monitoring fault (ZZUEBE) AzGrT actuated (ZAGBED) Section stable (ZSTABL) 1st clear indication register XDFMRG:

5

Bit 0:

Bit 2:

Track relay channel 1 (ZFMAN)

Inverted AzGrT acknowledgement bit (¬GT) 2nd clear indication register XDFMRG+1:

6

Bit 0:

Bit 2: Track relay channel 2 (ZFMAN) Reset restriction off (GE)

7 Previous operating state (before last AzGrT actuation) 8 Previous axle count (before last AzGrT actuation)

9 Total number of occupations since last system start-up, bits 0 ... 11 10 Total number of occupations since last system start-up, bits 12 ... 23 11 No function!

Display: Even and odd LEDs flash alternately 12 No function!

Display: Even and odd LEDs flash alternately

Table 7 Description of statistics function types for track vacancy detection section

If statistics function type 2 for TVDS (operating state) has been selected; the operating state for a selected TVDS (TVDS 1, 2, 3 or 4) is indicated on the left STEU 1 board. The following table explains the LED display:

LED Meaning of display after selection of function type "operating state"

(for TVDS object only)

0 Reset buttons of evaluation computer have been pressed. AzGrT must be actuated.

Flashing LED: System failure 1(*) Minus axle blocking effective

Counting capacity exceeded Undefined counted pulse 2 Count monitoring

3 Telegram transmission between evaluation computers is or was faulty or shutdown of second evaluation computer

4 Reset restriction

5 TVDS not clear; axle count not equal to zero, or one of the other LEDs is on 6 AzGrT inputs asynchronous

7 AzGrH buttons have been actuated 8 TVDS unstable

9 Block input of second evaluation computer asynchronous 10 Counting capacity exceeded

11 Undefined counted pulse

Table 8 Meaning of display after selection of function type 2 – operating state

NOTE (*)

The LEDs 1, 10 and 11 display, individually or in combination, the following:

LED no. LED display : ! = on, Ο = off

1 ● ● ●

10 ○ ● ○

11 ○ ○ ●

Meaning Minus axle blocking block effective

Counting capacity exceeded

Undefined counted pulse

The description of the statistics function types for the object Block info can be found in the following table:

Function

type Description of function type (block info)

1 Item of block information OUT 1 – 12, channel 1; 1st pair of BLEA12 2 Item of block information OUT 1 – 12, channel 2; 1st pair of BLEA12 3 Item of block information OUT 13 – 24, channel 1; 2nd pair of BLEA12 4 Item of block information OUT 13 – 24, channel 2; 2nd pair of BLEA12 5 Item of block information IN 1 – 12, channels 1 and 2; 1st pair of BLEA12 6 Item of block information IN 13 – 24, channels 1 and 2; 2nd pair of BLEA12 7 Distribution of block information for 1stpair of BLEA 12 boards

(DIP switches B0 – B4)

8 Distribution of block information for 2ndpair of BLEA 12 boards (DIP switches B0 – B5 and CHANG1, CHANG2)

9 No function!

Display: Even and odd LEDs flash alternately 10 No function!

Display: Even and odd LEDs flash alternately 11 No function!

Display: Even and odd LEDs flash alternately 12 No function!

Display: Even and odd LEDs flash alternately

Table 9 Description of statistics function types for block information

NOTE

The contents of the items of block information are specified by the railway operator.

The description of the statistics function types for the object System info can be found in the following table:

Function

type Description of function type (for system info) 1 Software version

2 Software date: DAY (bits 0 – 7); MONTH (bits 8 – 11) 3 Software year: bits 0 – 7

Software variant:

4

LED 0 on STEU 1:

LED 1 on STEU 1:

LED 2 on STEU 1:

LED 3 on STEU 1:

LED 7 on STEU 1:

Level crossing software

Software for China, TVDS-specific Software for China, CH-specific Decentralised electric points software CH test pulse during system start 5 Address of SIRIUS2 board, channel 1

6 Address of SIRIUS2 board, channel 2 Software operating mode from channel 1 7

LED 0, 1 on STEU 1:

LED 2 on STEU 1:

LED 3 on STEU 1:

LED 4 on STEU 1:

LED 5 on STEU 1 LED 6 on STEU 1:

LED 7 on STEU 1:

vAzGr mode

Clear indication via AzGr CHFMOUT

TELFM TD (channel 1) Axle oscillation Baud rate (channel 1) Software operating mode from channel 2 8

LED 0, 1 on STEU 1:

LED 2 on STEU 1:

LED 3 on STEU 1:

LED 4 on STEU 1:

LED 5 on STEU 1:

LED 6 on STEU 1:

LED 7 on STEU 1:

vAzGr mode

Clear indication via AzGr CHFMOUT

TELFM TD (channel 2) Axle oscillation Baud rate (channel 2) 9 No function!

Display: Even and odd LEDs flash alternately 10 No function!

Display: Even and odd LEDs flash alternately 11 No function!

Display: Even and odd LEDs flash alternately 12 No function!

Display: Even and odd LEDs flash alternately

Determining the display result:

The display result on the left STEU 1 board is determined using the dual system approach. The result can be calculated by summing up the values of the LEDs that are on.

LED no. Exponent of 2 Value

0 (20) 1

1 (21) 2

2 (22) 4

3 (23) 8

4 (24) 16

5 (25) 32

6 (26) 64

7 (27) 128

8 (28) 256

9 (29) 512

10 (210) 1024

11 (211) 2048

Table 10 Determining the display result using the LED display on left STEU 1

Display example:

LEDs being permanently on

Value

0 1

2 4

4 16

6 64

Total 85

Table 11 Example of result calculation