Improper adjustment of the controls may cause injury and call a qualified technician to return the device to normal operation. Safety Check - After service or repair is completed on the unit, ask the service technician to perform safety checks to ensure proper operation of the unit. Make sure the power has been disconnected before connecting, installing or disassembling the device.

Make sure that the signal connected to the device is a weak current (switch) signal; otherwise components of the device will be damaged. In case of power supply damage, return the device to the professional technical staff or your dealer for handling. If the device has major defects that you cannot resolve, contact your dealer as soon as possible.

Do not apply resin, alcohol, benzene, pesticides and other volatile substances that may damage the device casing. Be sure to connect the wires according to the positive polarity and negative polarity shown on the device's nameplate.

LOCK CONNECTION

DOOR BELL & DOOR SENSOR & EXIT BUTTON & ALARM CONNECTION

RS485 AND RS232 CONNECTION

WIEGAND READER CONNECTION

POWER CONNECTION

ETHERNET CONNECTION

Before getting into the features and functions of the device, it is recommended that you familiarize yourself with the basics below. Recommended fingers: index, middle or ring finger; avoid using thumb or little finger as they are difficult to press accurately on the fingerprint reader. Note: Please use the correct method when pressing your fingers on the fingerprint reader for registration and identification.

Our company will not take any responsibility for recognition issues that may result from incorrect use of the product. When there is no Super Administrator assigned to the device, tap M/OK to go to the menu. After adding a Super Administrator to the device, it requires Super Administrator verification before opening menu functions.

Note: For the safety of the device, it is recommended that you register a super administrator the first time you use the device.

FINGERPRINT VERIFICATION

CARD VERIFICATION

PASSWORD VERIFICATION

Contains basic information of registered users, including user ID, name, user role, fingerprint, badge number, password and access control role. User Role It is used to set user roles for accessing the menu and editing options. It is used to set the related parameters of the communication between the device and the PC, including Ethernet parameters such as IP address etc., Serial communication, PC connection, Wireless network, ADMS and Wiegand settings.

System It will set related system parameters, upgrade firmware, set date and time, set presence and fingerprint parameters and factory reset. Customize Set the interface screen, voice, ringer, mode of the kick status key and shortcut key. It will set the parameters of the control lock and access control devices, including access control parameters, timing, holidays, access groups, combined verification, anti-backpass options and coercion.

USB Manager Transfers user data and attendance logs from a USB drive to supporting software or other devices. Auto Test It will automatically test various functions of the module including LCD, voice, keyboard, fingerprint sensor and clock RTC test.

REGISTER A USER ID AND NAME

SETTING THE USER ROLE

Note: If the selected user role is the Super Admin, the user must pass the identity authentication to access the main menu.

REGISTER FINGERPRINT

REGISTER CARD NUMBER

REGISTER PASSWORD

ACCESS CONTROL ROLE

In the All Users interface, enter the user ID, for example 2, and press M/OK, and the system will search for the corresponding user information. Note: The process of editing user information is the same as adding a new user, except that the user ID cannot be changed when editing a user. Delete user: deletes all data about the user from the device (deletes the selected user as a whole).

You can set the permission scope of the custom role (maximum 3 roles) and the subscriber, that is, the permission scope of the control menu. Press ▲/▼ to select Enable Defined Role and press M/OK to enable or disable the user-defined role. Press ▲/▼ to select Name and press M/OK to enter the custom role name.

However, if no super administrator is registered on the device, the device will prompt "Enroll a super administrator first!" when you enable the user role feature. When the device needs to communicate with a PC via Ethernet, you must configure the network settings and ensure that the device and the PC connect to the same network segment. The Serial Comm function enables communication with the device via the serial port (/RS485/. Main unit).

Master Unit: When RS485 is used as the function of "Master unit", the unit will work as a master unit and it can be connected to RS485 fingerprint & card reader. The higher the baud rate, the faster the communication speed, but also less reliable. Comm Key makes it easier to improve data security by setting up the communication between the device and the PC.

Once the Comm key is pressed, a password is required to connect the device to the PC software. Comm key Default password is 0 and can be changed. The Comm key can contain 1-6 digits. If the communication method is RS232/RS485, you need to enter this device ID in the communication interface of the software.

WIEGAND INPUT

Bits 2 to 9 are page codes, while bits 10 to 25 are card numbers. Bits 18 to 33 are card numbers and bits 34 to 35 are manufacturer codes. Bits 2 to 19 are device codes, and bits 20 to 35 are card numbers.

WIEGAND OUTPUT

CARD FORMAT DETECT AUTOMATICALLY

Select Date Time on the System interface and press M/OK to set the date and time. Select Reset on the System interface and press M/OK to restore the default factory settings. Select User Interface on the Customize interface and press M/OK to adjust the display style of the main interface.

Select Call Schedules on the Personalize interface and press M/OK to configure the call settings. Select Punch Status Options in the Personalize interface and press M/OK to configure the punch status settings. Select Hotkey Assignments in the Personalize interface and press M/OK to set the hotkeys you want.

Select Backup to device (or Backup to USB drive) on the backup data interface and press M/OK. Select Restore from Device (or Restore from USB Drive) in the Restore Data interface and press M/OK. Select Time Schedule on the access control interface and press M/OK to configure the time settings.

Select Holidays on the Access Control interface and press M/OK to set the Holiday access. Select Add Holiday on the Holidays interface and press M/OK to set the holiday parameters. Select Access Group on the Access Control interface and press M/OK to set the group.

Select New Group on the Access Groups interface and press M/OK to set the group parameters. Select Include Holidays on the Access Groups interface and press M/OK to turn the access group ON. Select Combined authentication on the Access Groups interface and press M/OK to configure the combined authentication setting.

On the Access Control interface, select Enforcement Options and press M/OK to configure the enforcement settings. Select Attendance Search in the main menu interface and press M/OK to search the required event logs.