Copyright © The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated VERHAEGEN ET AL.

DEFINING “NORMAL”STATIC AND DYNAMIC SPINOPELVIC CHARACTERISTICS.ACROSS-SECTIONAL STUDY

http://dx.doi.org/10.2106/JBJS.OA.22.00007 Page 1

The following content was supplied by the authors as supporting material and has not been copy-edited or verified by JBJS.

Supplementary table 1. Interobserver reliability for each of the variables

Intraclass correlation coefficient 95% Confidence Interval LLstanding

LLdeep-seated

0.890 0.919

0.595 to 0.966 0.747 to 0.974 SSstanding

SSdeep-seated

0.951 0.975

0.845 tot 0.984 0.925 to 0.992 PTstanding

PTdeep-seated

0.993 0.980

0.979 to 0.998 0.937 to 0.993 PFAstanding

PFAdeep-seated

0.841 0.956

0.599 to 0.937 0.864 to 0.986

PTstanding 0.966 0.895 to 0.989