BATAAN PENINSULA STATE UNIVERSITY A1

TECHNICAL WORKING GROUP FOR INFRASTRUCTURE

BATAAN PENINSULA STATE UNIVERSITY, ABUCAY CAMPUS

UNIVERSITY PRESIDENT

DR. GREGORIO J. RODIS

VICE PRESIDENT ADMIN. & FINANCE

DR. EDMUNDO C. TUNGOL

APPROVED BY:

RECOMMENDED BY:

REVISION

NO.

2

DESCRIPTION DATE

SHEET CONTENT:

LOCATION:

AR. JO-ANA Z. TANEGA AR. ROXETTE S. UMEREZ

PREPARED BY:

CHECKED BY:

ARCHITECT II, TWG CONSULTANT

AR. DANILO Y. GALURA

REVIEWED BY:

C:\Users\User\Desktop\CJAE\logo-bpsu.png

SHEET NUMBER:

ABUCAY CAMPUS

(2)

dn dn

LOCATION :

WINDOW TYPE - W-3

SETS REQUIRED:

TOILET FACILITY ELEM. ROOM

SPECIFICATION:

LOCKSET: AS PER MANUFACTURER SPECIFICATION

TYPE: SLIDING WINDOW

1/4" THK ORDINARY CLEAR GLASS uPVC FRAME WITH

POWDER COATED FINISHED

F.F.L.

5 SETS

LOCATION :

WINDOW TYPE - W-2

SETS REQUIRED:

LECTURE ROOM (ELEMENTARY)

SPECIFICATION:

LOCKSET: AS PER MANUFACTURER SPECIFICATION TYPE: JALOUSIE WINDOW

1/4" THK ORDINARY JALOUSIE GLASS ALUMINUM WITH

WHITE POWDER COATED FINISHED

F.F.L.

10 SETS

LOCATION :

WINDOW TYPE - W-1

SETS REQUIRED:

LECTURE ROOM (ELEMENTARY)

SPECIFICATION:

LOCKSET: AS PER MANUFACTURER SPECIFICATION TYPE: JALOUSIE WINDOW

1/4" THK ORDINARY JALOUSIE GLASS ALUMINUM WITH

WHITE POWDER COATED FINISHED

F.F.L.

45 SETS

TYPE :

SETS REQUIRED:

CASING:

HINGES : LOCATION :

LOCKSET/

HANDLE:

FRAMING / JAMB:

AS PER MANUFACTURER SPECIFICATION.

AS PER MANUFACTURER

DOOR TYPE - D-1

PRE-PAINTED

WINDOWED SOLID PANEL DOOR LECTURE ROOM (ELEM. ROOM)

AS PER MANUFACTURER SPECIFICATION.

46 SETS

F.F.L.

D 1

F

KILN DRIED

TYPE :

SETS REQUIRED:

CASING:

HINGES : LOCATION :

LOCKSET/

HANDLE:

FRAMING / JAMB:

AS PER MANUFACTURER SPECIFICATION.

AS PER MANUFACTURER

DOOR TYPE - D-2

PRE-PAINTED uPVC DOOR TOILET FAC. (ELEM.RM)

AS PER MANUFACTURER SPECIFICATION.

5 SETS

F.F.L.

D 2

BATAAN PENINSULA STATE UNIVERSITY A2

TECHNICAL WORKING GROUP FOR INFRASTRUCTURE

BATAAN PENINSULA STATE UNIVERSITY,

REHABILITATION OF OLD ENGINEERING BUIILDING AT

ABUCAY CAMPUS

UNIVERSITY PRESIDENT

DR. GREGORIO J. RODIS

VICE PRESIDENT ADMIN. & FINANCE

DR. EDMUNDO C. TUNGOL

APPROVED BY:

RECOMMENDED BY:

REVISION

NO.

2

DESCRIPTION DATE

SHEET CONTENT:

LOCATION:

AR. JO-ANA Z. TANEGA AR. ROXETTE S. UMEREZ

PREPARED BY:

CHECKED BY:

ARCHITECT II, TWG CONSULTANT

AR. DANILO Y. GALURA

REVIEWED BY:

C:\Users\User\Desktop\CJAE\logo-bpsu.png

SHEET NUMBER:

ABUCAY CAMPUS

(3)

d

dn dn

d

dn dn

BATAAN PENINSULA STATE UNIVERSITY A3

TECHNICAL WORKING GROUP FOR INFRASTRUCTURE

BATAAN PENINSULA STATE UNIVERSITY, ABUCAY CAMPUS

UNIVERSITY PRESIDENT

DR. GREGORIO J. RODIS

VICE PRESIDENT ADMIN. & FINANCE

DR. EDMUNDO C. TUNGOL

APPROVED BY:

RECOMMENDED BY:

REVISION

NO.

2

DESCRIPTION DATE

SHEET CONTENT:

LOCATION:

AR. JO-ANA Z. TANEGA AR. ROXETTE S. UMEREZ

PREPARED BY:

CHECKED BY:

ARCHITECT II, TWG CONSULTANT

AR. DANILO Y. GALURA

REVIEWED BY:

C:\Users\User\Desktop\CJAE\logo-bpsu.png

SHEET NUMBER:

ABUCAY CAMPUS

(4)

INSTALLATION SHALL BE NEW SUITABLE FOR THE TYPE 3. WORKMANSHIP SHALL BE HIGHEST STANDARDS AND 2. UTILIZATION VOLTAGE SHALL BE 230V 3 Ø 60 Hz.

BUILDING OFFICIALS WITH JURISDICTIONS. BUREAU OF 1. ALL WORKS SHALL COMPLY WITH THE PROVISION

WALL RECEPTACLES = 300 MM ON CENTER WALL SWITCHES = 1300 MM ON CENTER

REFER TO ARCHITECT FOR OTHER CASES OF PANEL BOARDS = 1800 MM ON CENTER

PERPENDICULAR TO THE BUILDING STRUCTURES AND

ENGINEER/ MASTER ELECTRICIAN.

EQUIPMENT ARE AS FOLLOWS:

SUPERVISION OF A DULY LICENSED ELECTRICAL 6. ALL WORK SHALL BE DONE UNDER DIRECT INSTALLATIONS.

5. GENERAL MOUNTING HEIGHT OF DEVICES AND FINISHES.

THE REQUIREMENTS AND ORDINANCE OF THE

QUALITY. ALL MATERIALS TO BE USED FOR

4. EXPOSED WIRING WORK SHALL RUN IN PANEL OR AND PURPOSE OF APPLICATION.

FIRE DEPARTMENT AND LOCAL POWER/ TELEPHONE COMPANY.

GENERAL NOTES

ELECTRICAL CODE (PEC) AND SPECIFICATION WITH OF THE LATEST EDITION OF THE PHILIPPINE

BATAAN PENINSULA STATE UNIVERSITY E1

TECHNICAL WORKING GROUP FOR INFRASTRUCTURE

BATAAN PENINSULA STATE UNIVERSITY,

REHABILITATION OF OLD ENGINEERING BUIILDING AT

ABUCAY CAMPUS

UNIVERSITY PRESIDENT

DR. GREGORIO J. RODIS

VICE PRESIDENT ADMIN. & FINANCE

DR. EDMUNDO C. TUNGOL

APPROVED BY:

RECOMMENDED BY:

REVISION

NO.

2

DESCRIPTION DATE

SHEET CONTENT:

LOCATION:

AR. JO-ANA Z. TANEGA AR. ROXETTE S. UMEREZ

PREPARED BY:

CHECKED BY:

ARCHITECT II, TWG CONSULTANT

AR. DANILO Y. GALURA

REVIEWED BY:

C:\Users\User\Desktop\CJAE\logo-bpsu.png

SHEET NUMBER:

ABUCAY CAMPUS

(5)

ALL PLUMBING WORK INCLUDE HEREIN SHALL BE EXECUTED ACCORDING TO THE REQIREMENT OF THE PHILIPPINE'S PLUMBING CODE THE RULES AND THE REGULATION OF THE CITY GOVERNMENT, OR MUNICIPALITY

COORDINATION WITH DRAWING AND OTHER RELATED SPECIFICATION, THE ARCHITECT SHALL BE NOTED IMMEDIATELY IF ANY DESCREPANCY FOUND THEREIN

PIPES SHALL BE INSTALLED AS INDICATED ANY RELOCATION

REQUIREMENT FOR PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APROVAL OF ARCHITECT AND ENGINEER

PROPOSE SANITARY UTILITIES SHALL CONFORMED TOTHE ACTUAL LOCATION, DEPTH AND INVERTED ELEVATION OF ALL EXISTING PIPES AND STRUCTURE

ALL FIXTURES SHALL BE VENTED UNLESS OTHERWISE INDICATED

RUN ALL HORIZONTAL PIPING PERPECT ALLIGNMENT AND AT UNIFORM OF NOT LESS THAN TWO PERCENT (%)

ALL CHANGE OF DIRECTION SHALL BE MADE BY APPROPRIATE USE OF THE 45° WYES, LONG SWEEP, QUARTER BEND SIXTH OR EIGHTH TO SIXTEENTH BENDS A SINGLE 1/8 BEND COMBINATION MAY BE USE ON VERTICAL STACK AND SHORT QUARTER BEND MAY BE USE VENT TYPES

NO DOUBLE HUBS, DOUBLE TEE BRANCH SHALL BE USE ON HORIZONTAL SOIL WASTE LINE, THE DRILLING OR TAPPING OF HOUSE DRAIN WASTE OR VENT PIPES AND SADDLE HUBS AND VENT PROHIBITED

PROVIDE PIPE SLEEVES AT WALLS COLUMN SLAB ONE SLAB ONE BIGGER THAN ACTUAL SIZE PASSING THROUGH WALLS OR SLAB TO PIPES FROM BREAKAGE

CLEANOUT ARE REQUIRE UNDER THE FOLLOWING CONDITION 1. EVERY CHANGE IN HORIZONTAL DIRECTION EXCEEDING 22 1/2 ONE HALF DEGREES.

2. 1500mm INSIDE THE PROPERTY LINE THE DRAIN CONNECTOR 3. EVERY 150mmØ IN HORIZONTAL RUN PIPE

4. AT THE END OF THE HORIZONTAL PIPE LINE

A DEAD END IN THE INSTALLATION OF ANY PLUMBING SYSTEM IS PROHIBITED

NO REVISION IN THE DESIGN SHALL BE DONE WITH OUT THE PROPER KNOWLEDGE AND APPROVAL OF THE DESIGNER AND THE OWNER ANY SUCH REVISION DONE WITHOUT THE APPROVAL SHALL COURSE RESPONSIBILITY OF THE DESIGNER/ARCHITECT TO CEAS A WHOLE NO PIPING WORK FIXTURE OR EQUIPMENT SHALL BE CONCEALED OR COVERED BY ANY MAINS BEFORE THEY HAVE BEEN PRESSURE TESTED, FLOW TESTED AND INSPECTED BY THE ARCHITECT HAVING THE

JURISDICTION OF THE WORK

ALL WORK SHALL BE COMPLETELY INSTALLED AND TESTED AS REQUIRED BY THE SECTION 1378 AND SHALL BE LEAKTIGHT A T Q

UNLESS OTHERWISE NOTED AND SPECIFIED. USE NELTEX BRAND TO ALL MATERIALS OF ROUGHING OR AND APPROVED BY EQUIVALENT

XI DEAD END AVOIDED X CLEANOUT PIPES

VIII PROHIBITED FITTINGS VII CHANGE OF DIRECTION

VI GRADES OF HORIZONTAL PIPING

XIII

XV XIV XII

IX SLEEVES (NOT APPLICABLE) V FIXTURES

IV SANITARY UTILITIES III RELOCATION OF PIPES

II NOTIFICATION OF ARCHITECT I EXECUTION OF PLUMBING WORK

REF.RA 1378 NATIONAL PLUMBING CODE OF THE PHILS.

BATAAN PENINSULA STATE UNIVERSITY P1

TECHNICAL WORKING GROUP FOR INFRASTRUCTURE

BATAAN PENINSULA STATE UNIVERSITY, ABUCAY CAMPUS

UNIVERSITY PRESIDENT

DR. GREGORIO J. RODIS

VICE PRESIDENT ADMIN. & FINANCE

DR. EDMUNDO C. TUNGOL

APPROVED BY:

RECOMMENDED BY:

REVISION

NO.

2

DESCRIPTION DATE

SHEET CONTENT:

LOCATION:

AR. JO-ANA Z. TANEGA AR. ROXETTE S. UMEREZ

PREPARED BY:

CHECKED BY:

ARCHITECT II, TWG CONSULTANT

AR. DANILO Y. GALURA

REVIEWED BY:

C:\Users\User\Desktop\CJAE\logo-bpsu.png

SHEET NUMBER:

ABUCAY CAMPUS