• Tidak ada hasil yang ditemukan

BOQ

N/A
N/A
Protected

Academic year: 2024

Membagikan "BOQ"

Copied!
3
0
0

Teks penuh

(1)

ADMN-QF-09

Republic of the Philippines

CAVITE STATE UNIVERSITY

Don Severino delas Alas Campus Indang, Cavite

BILL OF QUANTITIES

IMPROVEMENT OF BACOOR CAMPUS (REPAIR OF FIVE-STOREY MAIN BUILDING)

ABC: ₱ 8,000,000.00 Bill of Quantities

COLLEGE/UNIT/CAMPUS: CvSU BACOOR CAMPUS Item

No. Description Unit Quantity Unit Price

(Pesos)

Amount (Pesos)

I

DISMANTLING AND CHIPPING WORKS

(Pesos _______________________

_____________________________

_____________________________

and _________________ centavos)

II

TILE WORKS

(Pesos _______________________

_____________________________

_____________________________

and _________________ centavos)

III

FIRE PROTECTION WORKS (Pesos _______________________

_____________________________

_____________________________

and _________________ centavos)

IV.

ELECTRICAL WORKS

(Pesos _______________________

_____________________________

_____________________________

and _________________ centavos)

GRAND TOTAL ___________

Write grand total in words

________________________________________

________________________________________

________________________________________

Submitted by: Date: ______________

Name of Bidder/Bidder’s Representative: ____________________________________________

Position: ___________________________________________________________________

Construction Company/Contractor: __________________________________________________

V01-2018-06-14 Page 1 of 3- Improvement of Bacoor Campus (Repair of Five-Storey Main Building)

(2)

CAVITE STATE UNIVERSITY SCOPE OF WORK:

A. IMPROVEMENT OF BACOOR CAMPUS (REPAIR OF FIVE-STOREY MAIN BUILDING) GENERAL NOTES:

1. The project should be finished in 180 calendar days.

2. Actual site inspection is a must.

B. Technical Description

I. Dismantling and Chipping Works A. Mobilization/Demobilization

Provide the following:

- Billboard

- Bunkhouse with office - Temporary comfort rooms

- Site temporary enclosure may be blue sack or any suitable materials that may enclose the workplace.

II. Tile Works (Fourth Floor only)

1. Supply and installation of homogenous 16” X 16” floor tiles for the whole fourth floor.

Tiles must be accepted with dark color.

2. Replacement of all floor/wall tiles of all comfort rooms on the fourth floor.

- Provide 24” x 24” non skid ceramic tiles for flooring and 12” x 24” for walls.

- Provide 24” x 24” ceramic tiles for concrete counters.

3. Consult the end user for color preference of tiles.

III. Fire Protection Work (Ground Floor to 5th Floor) 1. Supply and installation of the following:

a. 1 unit cistern tank (2m x 4m x 2m) b. 1 unit Fire Pump (30.0 HP)

c. 1 unit Jockey Pump (5.0 HP)

d. 1 unit Stainless water tank, Capsule type with partition Thickness: 1.20m; Length: 2.54m; Diameter: 2.20m e. Sprinkler system and its accessories

- 1057 pcs pendant type sprinkler

f. Adopt PPR pipes (PN 20) and fittings for cistern tank and stainless water tank.

- Supply and installation of 50mm PPR pipes with 2 pcs stop valve from source to cistern tank

- Use 50mm Ø from cistern tank to stainless water tank IV. Electrical Works (4th floor to 5th floor)

● Dismantling of electrical devices/equipments need to be replaced.

● Chipping works for electrical wiring/conduit raceways.

● Supply and installation of the following:

1. Panel boards and circuit breakers (Refer to plan for ratings and specifications).

Note: Bolt-on type, Nema standard should be used.

2. Feeder Line including all its accessories (from source to MDP) 3. Electrical cable tray complete with all accessories.

4. Wiring conductors, PVC conduit, junction box, utility box from main panel to convenience outlet/ light outlet.

a. THHN stranded copper wire. Phelp Dodge or approved equal. Refer to schedule of loads for proper color coding of conductor wires.

b. PVC conduit orange pipe

c. Utility and junction boxes should be PVC and deep type.

d. Support brackets, hangers, rods and clamps.

5. Electrical fixtures/ switches/ outlets and other electrical devices. Refer to plan for the exact location and count of electrical fixtures/switches/outlets/devices/equipments.

a. Switches (Bticino, National or its equivalent)

b. ACU and Convenience outlets (Bticino, National or its equivalent) c. 2-18W (4”) LED Fluorescent lamp with diffuser

d. 100W LED high bay lamp

● Repair/restoration and re-paiting of concrete walls.

V01-2018-06-14 Page 2 of 3- Improvement of Bacoor Campus (Repair of Five-Storey Main Building)

(3)

● Consult plans and inspectors for details and extent of work.

C. Contractor of the said project must provide an as-built plan of the project at the end of the contract as a requirement for the release of their final billing.

D. Contractor’s PCAB license should have specialization in electrical works.

E. Contractor of the project must provide at least 1 boom/basket truck during the execution of electrical works.

F. For color/types of any fixtures or materials to be used on site, consult the end-user and the inspector for approval. Consult the plan and the scope of work for the extent of tasks of the contract. If possible, let the end-user sign your sample as proof of approval.Note: In the event that discrepancies on plans and scope of work occur, generally, the scope of work prevails.

G. Resident site engineer is a must for the projects to be undertaken by the contractor of the university. In cases where there are electrical works, it is required that an electrical engineer or a master electrician be a part of the contractor's team to supervise all electrical works.

Likewise, master plumbers must supervise plumbing works. It can be considered when only one person is the master plumber and master electrician at the same time as long as his major duty is supervision of both fields. Safety engineer is a must as per DOLE requirement. Note:

All key personnel should be included in the list of personnel for submission.

H. In cases of participation in two or more projects, the set of workers and foreman shall be different per project, however, the set of engineers and equipment may be reused.

I. Construction safety and health program as well as construction schedule (PERT/CPM/S-Curve) shall be provided by the winning bidder.

J. See plans/consult the end-user and project inspector for details and extent of work. The silence of specifications, plans, special provisions and supplementary specifications as to any detail, or the apparent omission therein of detailed description or definition of the quality of materials and workmanship shall be regarded to mean that only materials and workmanship of first class quality are to be used or employed.

V01-2018-06-14 Page 3 of 3- Improvement of Bacoor Campus (Repair of Five-Storey Main Building)

Referensi

Dokumen terkait

Electrical Discharge Machine (EDM) is a non traditional manufacturing process based on removing material from a part by means of a series of repeated electrical

a) Civil works activities already done until 25 Km. such as clearing and grubbing, roadway excavation along shoulders, stone crusher and quarry operations. b)The contractor s

 Works well for o Small to medium team size o In environments with frequent specification change o Where near instant communication is possible  Avoids issue with customer and

Effort put into building a strong, effective, and productive team will pay large dividends for both the Project Manager and the Chief Systems Engineer.. 6.4 TEAM BUSTERS It is

ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULY LICENSED WEATHERPROOF CONVENIENCE OUTLET, CAST-BOXES, JUNCTION BOXES SUBMIT SAMPLE FOR APPROVAL.. ELECTRICAL

tions:- a the notice of injury and the claim for compensation may, except where the person injured is the master, be served on the master of a ship as if he were the employer, but

However, in the following exceptional cases, master is not liable even where the tort is committed in the course of employment:  Employment of servant under compulsion: Where the

In cases where it is required to consider a priori a given function of time h t, which affects the course of innovation process for example, the amount of funding, control actions and