RECONSTRUCTION
2.1 Overview of Methodology
2.1.3 Virus Detection Methods
50 NucleoSpin RNA virus F (Machery–Nagel, Dueren, Germany) and the QIAamp Viral RNA Mini kit (Qiagen, Hilden, Germany), for the extraction of RNA from environmental water samples. Their results showed that the QIAamp Viral RNA Mini kit and the NucliSens isolation kit were the methods of choice for application in water monitoring (Burgener et al., 2003). For the purposes of this study, a TRIzol extraction method, the Roche High Pure PCR Template Preparation kit and the QIAamp Ultrasens virus kit were compared for optimal DNA and RNA extraction.
51 annealing include poorly designed primers, the annealing temperature, and sub-optimal buffer composition (Elnifro et al., 2000). The extension of the specific primer-target compound would also depend on the activity of the enzyme. In addition, the availability of dNTPs and the nature of the target DNA are vital.
The PCR is used in many applications such as detecting infectious agents, genetic disease diagnosis, genomic DNA or cDNA cloning, RNA amplification by reverse transcription PCR (RT-PCR), forensic sample studies, analysis and allele sequence variation(Viljoen et al., 2005). Soil samples and treated drinking water may contain substances such as humic acids and metals which may interfere with the chemical components of the PCR reaction (Abbaszadegan et al., 1999; Donaldson et al., 2002). Humic acid is a mixture of acids containing carboxyl and phenolate groups which can form complexes with ions in various environments (Baigorri, 2009). Polymerase chain reaction inhibition is however, considered negligible with certain concentration and extraction techniques which utilise filters (Van Heerden et al., 2005).
In some diagnostic settings, the use of PCR is limited by cost and occasionally inadequate test sample volume. A variant of PCR, termed multiplex PCR, attempts to overcome the lack of sample and improve the diagnostic capacity of PCR. More than one primer included in the multiplex PCR would be required to amplify more than one target sequence. This however increases the likelihood of false amplification products leading to primer dimer formation (Brownie et al., 1997). Poor sensitivity or specificity of certain specific targets in multiplex PCR may also create numerous problems when optimising the reaction (Polz & Cavanaugh, 1998). However, in a multiplex PCR study done by Rohayem et al. (2004), in which the detection of norovirus, astrovirus and adenovirus in clinical stool samples was described, it was shown that multiplex PCR was equally sensitive and specific when compared to simplex PCR. The detection limits of the multiplex PCR and the simplex PCR were determined using 10-fold serial dilutions of norovirus, astrovirus and adenovirus controls and were found to be similar, i.e. about 102 copies of virus particles could be detected. Multiplex PCR has also been applied productively in many areas of nucleic acid diagnostics. Examples of such applications would be RNA detection, mutation and polymorphism analysis and gene deletion analysis (Elnifro et al., 2000). The multiplex PCR technique was also shown to be a valuable method to identify viruses, bacteria, fungi and parasites.
Nested PCR refers to two pairs of primers being used to amplify a single fragment. The first pair amplifies the fragment in a normal PCR, while the second pair binds within the first PCR product. Incorrect initial amplification would yield little or no PCR product by a second primer
52 pair and thus the nested PCR technique is more specific than a normal PCR. The sensitivity of the nPCR could be enhanced by using ‘hot’ nPCR whereby one of the nested primers can be labelled with radio- or non-radioactive markers. Applications include identity confirmation and epidemiological studies (Viljoen et al., 2005).
Molecular beacons can be described as oligonucleotide probes which fluoresce upon hybridisation, thereby aiding with real-time monitoring of the target amplicon during the PCR reaction (Yates and Chen, 2003). Studies have shown that the technique is very sensitive, but not very specific, since it could detect low copies of hepatitis A but could not detect other enteric viruses. The principle of molecular beacons rests on intercalating fluorescence dyes which may partially prevent non-specific DNA synthesis by using labelled primers with a stem-loop structure (Figure 2.1). The native structure of the molecular beacon oligonucleotide folds into a hairpin loop. The beacon loses its hairpin loop structure upon PCR thermocycling where hybridisation to the PCR product occurs . The reporter and quencher molecules are spatially separated upon hybridisation, resulting in the quencher molecule being unable to absorb fluorescence from the reporter molecule. The reporter molecule could therefore be detected using fluorescence meas urement procedures (van Pelt-Verkuil et al., 2008). Molecular beacons are affected by various factors which may lead to false-positive or false-negative results. The most significant factor would be the distance between fluorescence– and quenching groups (Li et al., 2008). Other factors include the purity of the molecular beacons, and the temperature and pH at which molecular beacons are stored (Li et al., 2008; van Pelt-Verkuil et al., 2008).
Many variations/adaptations of the standard qualitative PCR have been developed. The hot- start PCR involves heating the PCR components to a certain temperature (e.g. 95ºC) before adding the polymerase enzyme, which reduces non-specific binding. Other variations to the PCR protocol include booster PCR and time release PCR (van Pelt-Verkuil et al., 2008).
Figure 2.1. General structure of a molecular beacon (van Pelt-V erkuil et al., 2008)
53 2.2 Pilot Study: Optimisation of Methods