CE 318
STRUCTURE ANALYSIS AND DESIGN II LAB
LECTURE 4
BEAM LOAD CALCULATION
COURSE TEACHER: SAURAV BARUA CONTACT NO: +8801715334075
EMAIL: [email protected]
LECTURE PLAN
Stair load calculation
Moment calculation
Reinforcement calculation
Stair reinforcement detailing
BEAM LAYOUT
BEAM CONTRIBUTORY AREA
CONTRIBUTORY AREA
• Beam B1 size = 12”x 18” (assume) explain in the class!!
• B1 contributory area = 2 x ½ x 15 x 4 + ½ x (9+18) x 8
= 168 sq. ft explanation Dead load calculation:
Slab thickness = 5”
Floor finish (FF) = 25 psf Wall load = 80 psf
B1 length = 15+18+ 15 = 48 ft.
CONTRIBUTORY AREA
• Dead load on beam = 5/12 x 0.15 + 0.025 + 0.08 ≈ 0.17 ksf x 168 = 286 kip / 48 = 5.96k/ft
Self weight of beam = (12 x 18)/(12 x 12) x 0.15 = 0.23 k/ft Total DL on beam per ft = 5.96+0.23 = 6.19 k/ft
Live load = 40 psf (BNBC)
Live load (LL) per ft = 0.04 x 168 = 6.72 kip /48 = 0.14k/ft
DEAD LOAD MOMENT (DLM)
M
DL,
A-ve= - 1/16 x w x L
2= -1/16 x 6.19 x 15
2= -87.1 k-ft/ft M
DL,
B+ve= + 1/14 x w x L
2= +1/14 x 6.19 x 15
2= +99.5 k-ft/ft M
DL,
C-ve=- 1/11 x w x L
2= -1/11 x 6.19 x 18
2= -182.32 k-ft/ft (Explanation!!)
M
DL,
D+ve=+ 1/14 x w x L
2= -1/14 x 6.19 x 18
2= +143.25 k-ft/ft
LIVE LOAD MOMENT (LLM)
M
LL,
A-ve= - 1/16 x w x L
2= -1/16 x 0.14 x 15
2= -1.97 k-ft/ft M
LL,
B+ve= + 1/14 x w x L
2= +1/14 x 0.14 x 15
2= +2.25 k-ft/ft M
LL,
C-ve=- 1/11 x w x L
2= -1/11 x 0.14 x 18
2= -4.12 k-ft/ft (Explanation!!)
M
LL,
D+ve=+ 1/14 x w x L
2= -1/14 x 0.14 x 18
2= +3.24 k-ft/ft
DEAD LOAD SHEAR (DLV)
V
DL,
A+ve= + 1/2 x w x L = +1/2 x 6.19x 15 = +46.43k/ft
V
DL,
C-ve= - 1/2 x w x L = -1/2 x 6.19 x 18 = -55.71 k-ft/ft
Take maximum shear. Shear +ve/-ve does not matter!!
LIVE LOAD SHEAR (LLV)
V
LL,
A+ve= + 1/2 x w x L = +1/2 x 0.14x 15 = +1.05 k-ft/ft
V
LL,
C-ve= - 1/2 x w x L = -1/2 x 0.14 x 18 = -1.26 k-ft/ft
Take maximum shear. Shear +ve/-ve does not matter!!
• Thumb rule,
• Earthquake load (EQ) = 10% of DL
• Wind load (WL) = 15% of DL
EARTHQUAKE LOAD MOMENT (EQM)
M
EQ,
A-ve= 0.1 x 87.1 = +8.7 k-ft/ft M
EQ,
B+ve= 0
M
EQ,
C-ve= 0.1 x 182.32 = -18.23 k-ft/ft
M
EQ,
D+ve= 0
WIND LOAD MOMENT (WLM)
M
wL,
A-ve= 0.15 x 87.1 = 13.07 k-ft/ft M
wL,
B+ve= 0
M
wL,
C-ve= 0.15 x 182.32 = 27.35 k-ft/ft
M
wL,
D+ve= 0
EARTHQUAKE LOAD SHEAR (EQV)
V
EQ,
A-ve= 0.1 x 46.43 = 4.7 k/ft V
EQ,
B+ve= 4.7k/ft
V
EQ,
C-ve= 0.1 x 55.71 = 5.6 k/ft
V
EQ,
D+ve= 5.6 k/ft
WIND LOAD SHEAR (WLV)
V
WL,
A-ve= 0.15 x 46.43 = 6.96 k/ft V
WL,
B+ve= 6.96k/ft
V
WL,
C-ve= 0.15 x 55.71 = 8.36 k/ft
V
WL,
D+ve= 8.36 k/ft
LOAD COMBINATION
• There are 16 load combination as per BNBC for buildings, in total 26 load
combinations. We will consider main 4 combination here. (Explanation in class!!) 1. 1.4 DL + 1.7 LL
2. 1.05 DL + 1.05 LL + 1.275 WL 3. 1.05 DL + 1.05 LL + 1.403 EQ 4. 1.4 DL + 1.4 LL + 1.4 EQ
EQ can be EQX+, EQX-, EQY+, EQY- WL can be WLX+, WLX-, WLY+, WLY-
MOMENT (k-ft/ft)
A B C D
DLM -87.1 +99.5 -182.32 +143.25
LLM -1.97 +2.25 -4.12 +3.24
EQM +8.7 0 -18.23 0
WLM +8.7 0 -18.23 0
SHEAR (k/ft)
A B C D
DLV +46.43 0 -55.71 0
LLV -1.05 0 -1.26 0
EQV +4.7 +4.7 +5.6 +5.6
WLV +6.96 +6.96 +8.36 +8.36
COMBINATION OF MOMENT (k-ft/ft)
Load combo
A B C D
1 -125.29 143.13 -262.25 206.06 2 -82.43 106.84 -219.01 153.81 3 -81.32 106.84 -221.34 153.81
COMBINATION OF SHEAR (k/ft)
copyright @Saurav Barua
Load
combo A B C D
1 63.22 0.00 -
80.14 0.00 2 56.52 8.87 -
49.16 10.66 3 54.24 6.59 -
51.96 7.86 4 70.11 6.58 -
71.92 7.84