,QSXW9ROWDJH ,QSXW&XUUHQW ,QSXW3RZHU 3RZHU)DFWRU /XPLQDQFH /XPLQRXV(IILFLHQF\ &5, %HDP$QJOH 0DLQ6WUXFWXUH 2XWSXW9ROWDJH 2XWSXW&XUUHQW 'ULYHU(IILFLHQF\ /('0DQXIDFWXUHU /('7\SH /('4XDQWLW\ /('(IILFDF\ &RORU7HPSHUDWXUH 3KRWRFHOO  /LIHVSDQ :DUUDQW\ ,35DWLQJ 2SHUDWLQJ7HPSHUDWXUH 6WRUDJH7HPSHUDWXUH+XPLGLW\ 6DIHW\6WDQGDUGV :LWKVWDQG9ROWDJH *URXQGLQJ5HVLVWDQFH (OHFWURPDJQHWLF&RPSDWLELOLW\ 'LPHQVLRQ 3OVUHIHUWRDWWDFKHGGLPHQVLRQDOGUDZLQJ 1HW:HLJKW *URVV:HLJKW 3DFNLQJ6L]H 4W\&DUWRQ 9ROXPH www.morrisproducts.com Cat# 71551 15 Watt

1/2" Adjustable Knuckle Mount

: 3)ุ /0 /0: 0 0RGHO᧶  9$&+= $0D[ $  3KLOOLSV /80,/('/8;(21/('  [r $OXPLQLXP+RXVLQJ3RO\FDUERQDWH/HQV 9'& +UV <HDUV ,3:HW/RFDWLRQV )WR) 3&6 /0: . 1RW,QFOXGHG .* ഒಧഒಧ5+ 8/8/(1(1(1(1 ,3)*9'& ื˖2. 3&6 29(5$///$03 3$5$0(7(56 /(''5,9(5 /(' /,)(63$1  (19,5210(17 6$)(7< (0& 27+(56 (1(1(1(1 .*

5

5R+6

(2)
(3)



QualityAssured NVLAP LAB CODE 0096o-D

  

LM-79-08 Test Report

 

For

Morris Products Inc.



53 Carey Rd Queensbury, NY 12804

Brand Name: Morris





LED FLOOD LIGHT

Model: 71551



Laboratory: Leading Testing Laboratories



NVLAP

CODE: 200960-0

Tel: +86-571-5668.0806 www.ledtestlab.com



Report No.: HZ15ll004la

 



The laboratory that conducted the testingdetailed in this report has beenaccredited for SSL by NVLAP.   Testspecifications: DateofReceipt DateofTest Test item  



ReferenceStandard   



Reviewedby:   :Nov.27,2015 :Dec. 01,2015

: Total Luminous Flux,Luminous DistributionIntensity,Luminous Efficacy,

CorrelatedColor Temperature,ColorRenderingIndex,Chromaticity

Coordinate,Electrical parameters

: IESNA LM-79-2008 ApprovedMethod for the Electrical and Photometric

 

Engineer: AprilZou

Dec. 04,2015

JimZhang

Dec.04,2015



(4)



Test Summary

Sample Tested: 71551  Luminous Efficacy (Lumens /Watt)

Total Luminous Flux (Lumens)

Power

(Watts) Power Factor

 96.6  1413.5 14.63 0.9810 CCT (K) 

CRI Stabilization Time

(Light & Power)

 5243  83.7 60  IES Classification 

Longitudinal Classification NEMA Type for Flood Fixture



Type I



Very Short 7 H x 7 V

Table 1: Executive Data Summary



Sample Photo

        



0 Horizontal        

Figure 1- Overview of the sample





Equipment Under Test (EUT)

Name : LED FLOOD LIGHT

Model : 71551

Electrical Ratings : 120~277Vac, 50/60Hz, 15W

Product Description : 5000K, 1 LED bar, Architectural Flood and Spot Luminaires

Manufacturer : Morris Products Inc.

(5)

Report No.: HZ15110041a

Prepared by: Leading Testing Laboratories

No.1805, DongLiu road, BinJiang District, Hangzhou, China

Page 3 of 12 Tel: +86-571-56680806 www.ledtestlab.com       



TABLE OF CONTENT





LM-79-08 Test Report... 1  Sample Photo... 2  TEST RESULTS ... 4 

Spectral Power Distribution ... 5 

IESNA Luminaire Flux Distribution Table ... 6 

Isoilluminance Plots of Horizontal Illuminance ... 7 

Luminous Intensity Distribution Plots... 8 

Luminous Intensity Data ... 9  EQUIPMENT LIST ... 11  TEST METHODS ... 11  Seasoning of SSL Product... 11  Goniophotometer Method ... 11 

Photometric and Electrical Measurements... 11 

Color Characteristics Measurements... 12 

(6)

Special Color Rendering Indices R1 82 R2 89 R3 93 R4 83 R5 83 R6 85 R7 87 R8 68 R9 10 R10 74 R11 82 R12 63 R13 84 R14 97  

TEST RESULTS



Test ambient temperature was 24.5 .

Sample orientation was light down. Test was conducted without a dimmer in the circuit.

The stabilization time of the sample was 60 minutes, and the total operating time including stabilization was 85 minutes.



Goniophotometer Method The photometric distance is 30m.

Luminous data was taken at 0.5°vertical intervals and 5 °horizontal intervals.

   Parameter  Result Test Voltage (V) 120.0 277.0 Voltage frequency (Hz) 60 60

Test Current (A) 0.124 0.060

Power Factor 0.9810 0.8989

Test Power (W) 14.63 14.94

THD A% 17.41 17.06

Luminous Efficacy (lm/W) 96.6



Total Luminous Flux (lm) 1413.5

Color Rendering Index (CRI) 83.7

R9 10

Correlated Color Temperature (CCT) (K) 5243 Chromaticity (Chroma x, Chroma y) (0.3389, 0.3513) Chromaticity (Chroma u, Chroma v) (0.2074, 0.3224) Chromaticity (Chroma uȽ, Chroma vȽ) (0.2074, 0.4836) Duv 0.0024 Average Beam Angle (°) 104.5

Center Beam Candle Power (cd) 548

Spacing Criteria 1.27 (0°-180°)/

1.38 (90°-270°) Zonal Lumens in the 0°-60°Zone 88.12% Zonal Lumens in the 60°-90°Zone 11.73% Zonal Lumens in the 90°-120°Zone 0.03% Zonal Lumens in the 120°-180°Zone 0.12%

Table 2: Test data per Goniophotometer Method

(7)

Report No.: HZ15110041a

Prepared by: Leading Testing Laboratories

No.1805, DongLiu road, BinJiang District, Hangzhou, China

Page 5 of 12 Tel: +86-571-56680806 www.ledtestlab.com    

Spectral Power Distribution

                            

(8)

 

IESNA Luminaire Flux Distribution Table



Zone Lumens Luminaire %

FL - Front-Low (0-30) 226.5 16.0

FM - Front-Medium (30-60) 399.2 28.2

FH - Front-High (60-80) 82.1 5.8

FVH - Front-Very High (80-90) 3.9 0.3

Total Forward Light 711.7 50.3



BL - Back-Low (0-30) 228.4 16.2

BM - Back-Medium (30-60) 391.6 27.7

BH - Back-High (60-80) 76.9 5.4

BVH - Back-Very High (80-90) 3.0 0.2

Total Back Light 699.9 49.5



UL - Uplight-Low (90-100) 0.1 0.0

UH - Uplight-High (100-180) 2.0 0.1

Total Up Light 2.1 0.1



BUG (Back, Up, Glare) Rating B1-U1-G0 Table 3: Flux Distribution Data

   Zone Downward Lumens Upward Lumens Total Lumens House Side 699.9 0 699.9 Street Side 711.7 0 711.7

Table 4: Flux Distribution Table

 

(9)

Report No.: HZ15110041a

Prepared by: Leading Testing Laboratories

No.1805, DongLiu road, BinJiang District, Hangzhou, China

Page 7 of 12 Tel: +86-571-56680806 www.ledtestlab.com







Isoilluminance Plots of Horizontal Illuminance







Distance In Units Of Mounting Height Values Based On 10 Foot Mounting Height

1/2 Maximum Candela Trace Shown As Dashed Curve (+) = Maximum Candela Point

(10)

 

Luminous Intensity Distribution Plots





Chart 3: Maximum Plane and Cone Plots of Candela Maximum Candela = 577.45 Located At Horizontal Angle = 190, Vertical Angle = 16.5 # 1 - Vertical Plane Through Horizontal Angles (190 - 10) (Through Max. Cd.)

# 2 - Horizontal Cone Through Vertical Angle (16.5) (Through Max. Cd.) 

(11)

Report No.: HZ15110041a

Prepared by: Leading Testing Laboratories

No.1805, DongLiu road, BinJiang District, Hangzhou, China

Page 9 of 12 Tel: +86-571-56680806 www.ledtestlab.com    

Luminous Intensity Data

                                          

(12)



(13)

Report No.: HZ15110041a

Prepared by: Leading Testing Laboratories

No.1805, DongLiu road, BinJiang District, Hangzhou, China

Page 11 of 12 Tel: +86-571-56680806 www.ledtestlab.com  



EQUIPMENT LIST

  Test Equipment 

Model Equipment No. Calibration Date

Calibration Due date Goniophotometer system GO-R5000 HZTE011-01 Jul. 17, 2015 Jul. 16, 2016 Digital Power Meter PF2010A HZTE028-01 Jul. 17, 2015 Jul. 16, 2016 AC Power Supply PCR 500L HZTE001-08 Jul. 17, 2015 Jul. 16, 2016 DC Power Supply WY12010 HZTE004-03 Jul. 17, 2015 Jul. 16, 2016 Temperature Meter TES1310 HZTE017-01 Jul. 17, 2015 Jul. 16, 2016

Standard Source D908 HZTE012-01 Jul. 23, 2015 Jul. 22, 2016

Standard source SCL-1400 HZTE012-02 Oct. 21, 2015 Oct. 20, 2016 Table 7: Test Equipment List



TEST METHODS

  Seasoning of SSL Product 

For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed.

   Goniophotometer Method 



Photometric and Electrical Measurements 



An EVERFINE Type C Model GO-R5000 Goniophotometer was used to measure the intensity at each angle of distribution for each sample. The photometric distance is 2.475m for near-field measurement or 30m for far-field measurement. Bandwidth of spectroradiometer is 380nm-780nm.

Ambient temperature was measured at the same height of the sample mounted on the Goniophotometer

equipment. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation.

The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaires). It can be judged that stability is reached when the variation (maximum ȸġminimum) of at least 3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5 %.

Electrical measurements including voltage, current, and power were measured using the Everfine Digital Power Meter.

Some graphics were created with Photometric Plus software.

The standard reference of the Goniophotometer system is halogen incandescent lamp, the intensity distribution type is omni-directional, and is traceable to the National Institute of Metrology P.R. China.

The uncertainty of goniophotometer system reported in this document is expended uncertainty is 1.8% with a coverage factor k=2.

(14)



Color Characteristics Measurements 



The color characteristics of SSL products include chromaticity coordinates, correlated color temperature, and color rendering index. These characteristics of SSL products may be spatially non-uniform, and thus, in order that they can be specified accurately, the color quantities shall be measured as values that are spatially average, weighted to intensity, over the angular range where light is intentionally emitted from the SSL product. The color characteristics measurements are using gonio-spectroradiometer.

 



Color Spatial Uniformity 



The characteristics of SSL products may be spatially non-uniform, the chromaticity coordinate shall be measured at two vertical planes (C=0°/180° and C=90°/270°) and at 10° or less intervals for vertical angle until the light output dropped to below 10% of the peak intensity. The average weighted chromaticity coordinate was calculated from these points. The data was then analyzed to check for delta color differences of the u', v' chromaticity coordinates. The spatial non-uniformity of chromaticity, u'v', is determined as the maximum deviation ( distance on the CIE (u', v') diagram) among all measured p o i n t s from the spatially a v e r a g e d chromaticity coordinate.

The geometry for the chromaticity measurement using gonio-spectroradiometer is shown as following.

      



*** End of Report ***

Gambar

Figure 1- Overview of the sample
Table 2: Test data per Goniophotometer Method
Table 4: Flux Distribution Table
Table 5: Luminous Intensity Data
+2

Referensi

Dokumen terkait

Sumber primer adalah sumber data yang langsung memberikan data, dalam hal ini adalah Pondok Pesantren Nurul Athfal Ulujami, yang berupa observasi dan wawancara

Seperti telah dibahas pada bagian tes dengan set data buatan, analisis penentuan metode pembebanan terbaik yang digunakan dilakukan dengan melihat tingkat penyimpangan arus

Enzim amilase dan selulase yang dihasilkan oleh Aspergillus niger akan menguraikan pati dan selulosa yang terdapat pada substrat menjadi glukosa, kemudian glukosa

Untuk mengetahui jumlah keterampilan heading berhasil dan gagal yang dilakukan tim PS TNI pada Putaran Kedua Piala Jendral Sudirman tahun 2015.. Untuk mengetahui

Hasil dari penelitian tersebut adalah terdapat perbedaan kinerja perusahaan yang digambarkan oleh rasio keuangan yaitu : rasio likuiditas, rasio rentabilitas, rasio solvabilitas,

Data yang diperlukan dalam penelitian ini adalah data Primer dan Data Sekunder.Dalam pengumpulan data, penelitian ini menggunakan kuesioner sebanyak 30

Bagi masyarakat, sebagai gambaran serta informasi mengenai kinerja sistem irigasi di daerah irigasi Serbangan Kecamatan Rawang Panca Arga Kabupaten

Chi-Square Distribution Test Results for Frequencies of Bloom's Taxonomy of Cognitive Domain Contained in the Chemistry Questions for the General Secondary Examination in Jordan