• Tidak ada hasil yang ditemukan

OPTIMASI CITRA RADIOGRAFI PADA PEMERIKSAAN PELVIS MENGGUNAKAN COMPUTED RADIOGRAPHY (CR)

N/A
N/A
Protected

Academic year: 2021

Membagikan "OPTIMASI CITRA RADIOGRAFI PADA PEMERIKSAAN PELVIS MENGGUNAKAN COMPUTED RADIOGRAPHY (CR)"

Copied!
12
0
0

Teks penuh

(1)

OPTIMASI CITRA RADIOGRAFI

PADA PEMERIKSAAN PELVIS MENGGUNAKAN

COMPUTED RADIOGRAPHY (CR)

SKRIPSI

Diajukan untuk melengkapi tugas dan memenuhi syarat mencapai gelar Sarjana Sains

Ridho Wahyudi 110821019

DEPARTEMEN FISIKA

FAKULTAS MATEMATIKA DAN ILMU PENGETAHUAN ALAM

UNIVERSITAS SUMATERA UTARA

MEDAN

2013

(2)

Judul :OPTIMASI CITRA RADIOGRAFI PADA PEMERIKSAAN PELVIS MENGGUNAKAN

COMPUTED RADIOGRAPHY (CR) Kategori : SKRIPSI

Nama : RIDHO WAHYUDI

NIM : 110821019

Program Studi : SARJANA (S1) FISIKA MEDIS Departemen : FISIKA

Fakultas : MATEMATIKA DAN ILMU PENGETAHUAN

ALAM UNIVERSITAS SUMATERA UTARA

Diluluskan di:

Medan, 28 Agustus 2013

Diketahui/Disetujui oleh

Departemen Fisika FMIPA USU Pembimbing, Ketua,

(Dr. Marhaposan Situmorang)

(Drs. Kurnia Sembiring, MS)

NIP. 195510301980031003

NIP. 195801311986011001

(3)

PERNYATAAN

OPTIMASI CITRA RADIOGRAFI PADA PEMERIKSAAN PELVIS MENGGUNAKAN COMPUTED RADIOGRAPHY (CR)

SKRIPSI

Saya mengaku bahwa skripsi ini adalah hasil kerja saya sendiri, kecuali beberapa kutipan dan ringkasan yang masing-masing disebutkan

sumbernya.

MEDAN, 28 Agustus 2013

RIDHO WAHYUDI 110821019

(4)

PENGHARGAAN

Alhamdulillah, puji syukur saya panjatkan kepada Allah SWT, karena atas berkat dan rahmat-Nya, saya dapat menyelesaikan skripsi ini. Penulisan skripsi ini dilakukan dalam rangka memenuhi salah satu syarat untuk mencapai gelar Sarjana Sains Jurusan Fisika Medis pada Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Sumatera Utara.

Saya menyadari bahwa, tanpa bantuan dan bimbingan dari berbagai pihak, dari masa perkuliahan sampai pada penyusunan skripsi ini, sangatlah sulit bagi saya untuk menyelesaikan skripsi ini. Oleh karena itu, saya mengucapkan terima kasih kepada :

1. Bapak Dr. Marhaposan Situmorang, selaku Ketua Departemen Fisika FMIPA Universitas Sumatera Utara;

2. Bapak Drs. Syahrul Humaidi, MSc selaku Sekretaris Jurusan Departemen Fisika FMIPA Universitas Sumatera Utara;

3. Bapak Drs. Herli Ginting, MS, Selaku koordinator Program Ekstansi Departemen Fisika FMIPA Universitas Sumatera Utara.

4. Bapak Drs. Kurnia Sembiring, MS selaku Dosen Pembimbing yang telah menyediakan waktu, tenaga, dan pikiran untuk mengarahkan saya dalam penyusunan skripsi ini;

5. Dr. Susilawati, M.Si, Dr. Perdinan Sinuhaji, MS dan Drs. Syahrul Humaidi, MSc selaku dosen penguji sidang tugas akhir;

6. Seluruh staf dan dosen Jurusan Fisika Medik Fakultas Matematika dan Ilmu Pengetahuan alam Universitas Sumatera Utara yang telah memberikan dorongan semangat dan senantiasa membantu penulis didalam melengkapi administrasi;

7. Bapak Dr. H . Nanang Fitra Aulia, Sp.PK selaku Direktur RSUD Dr. H. Kumpulan Pane Kota Tebing Tinggi, yang telah mengizinkan pengambilan data;

(5)

8. Kepala Instalasi Radiologi dan seluruh rekan – rekan di Instalasi Radiologi RSUD Dr. H. Kumpulan Pane Kota Tebing Tinggi yang telah banyak membantu dan memberikan kelonggaran waktu kepada saya untuk kuliah dan menyelesaikan Skripsi ini;

9. Ibunda ( Ramlah Harahap ) dan ayahanda ( Misno ) terimakasih atas do’anya;

10. Istriku Tercinta Syahniarina V Damanik atas doa, kasih sayang,

pengertian , perhatian serta dorongan semangat yang tidak pernah padam dan semua pengorbanan yang telah di berikan;

11. Anakku Tersayang Malika Ririn Cajasi yang telah memberikan dorongan dan semangat untuk menyelesaikan kuliah dan skripsi ini, keberadaanmu sangat luar biasa;

12. Ibu Lengkam Purba yang telah memberikan doa, semangat dan dukungan kepada penulis.  

13. Seluruh rekan-rekan stambuk 2011 khusus nya Bang Dody, Kak Juariah, Helmina Munthe dan Nuriani Nainggolan yang telah banyak memberikan masukan dan motifasi kepada penulis dalam menyelesaian skripsi ini.

14. Serta semua pihak yang telah mendukung dan mendoakan dalam penyelesaian skripsi ini.

Akhir kata, saya berharap Allah SWT berkenan membalas segala kebaikan semua pihak yang telah membantu. Semoga Skripsi ini membawa manfaat bagi pengembangan ilmu.

Medan, 28 Agustus 2013

Penulis

(6)

ABSTRAK

Telah dilakukan penelitian optimasi citra radiografi dengan phantom rando menggunakan sistem Computed Radiography (CR) type Prima T Drypic 2000, Untuk pemeriksaan Pelvis Antero Posterior (AP). Optimasi pembentukan citra dievaluasi berdasarkan panduan dari European Commission dengan kriteria penerimaannya, kondisi eksposi kVp dan mAs, kontras tinggi dan kontras rendah. Selain evaluasi visual citra untuk optimasi diperhatikan pula karakter incident exposure Computed Radiography (CR) yang dinyatakan dengan Sensitivity Value (S Value) dengan proses digitasi citra yang dapat dilihat pada tampilan image consule dan softwere ImageJ. Hasil penelitian optimasi menunjukkan bahwa untuk pemeriksaan pelvis Antero Posterior (AP) optimasi terjadi pada eksposi 75 kVp 10 mAs.

Kata kunci :

(7)

ABSTRACT

A research about a radiography image optimization using a rando phantom by Computed Radiography (CR) type Prima T Drypic 2000 system has been done, for examination of Antero Posterior (AP) pelvis. The optimization of image formation was evaluated based on guidance from European Commission with their acceptance criterian, the condition of kVp and mAs, high contrast and low contrast. Beside the image visual evaluation for optimization, the Computed Radiography (CR) incident exposure was also observed which is stated in Sensitivity Value (S Value) by image digitations process that can be seen at image console and imageJ software. The result of optimization research show that for the AP pelvis, optimization was when 75 kVp 10 mAs

Keywords:

(8)

DAFTAR ISI

HALAMAN JUDUL i

LEMBAR PERSETUJUAN iii

PERNYATAAN iv PENGHARGAAN v ABSTRAK vii ABSTRACT vii DAFTAR ISI ix DAFTAR GAMBAR xi

DAFTAR TABEL xii

DAFTAR LAMPIRAN xiii

1. PENDAHULUAN 1 1.1. Latar Belakang 1 1.2. Perumusan Masalah 2 1.3. Pembatasan Masalah 3 1.4. Tujuan Penelitian 3 1.5. Manfaat Penelitian 3 2. LANDASAN TEORI 4 2.1. Pendahuluan Sinar – X 4 2.2. Kualitas Citra 6

2.2.1. Ketajaman dan Kontras Radiografi 7

2.2.2. Noise Radiografi 7

2.3. Sistem Computed Radiografi 7

2.3.1. Imaging Plate 8

2.3.2. Image Reader 11

2.3.3. Image Recorder 12

2.3.4. Personal Computer 12

2.4. Prinsip Kerja Sistem Computed Radiography 12

2.5. Nilai Pixel 14

(9)

2.7. Anatomi Pelvis 17

2.8. Phantom Rando 18

2.9. Sofware Image J 19

2.10. Kriteria Penerimaan Citra 20

3. METODE PENELITIAN 21

3.1. Peralatan dan Bahan 21

3.2. Tahap Penelitian Pengambilan Data 23

4. HASIL DAN PEMBAHASAN 25

4.1. Hasil Penelitian 25

4.2. Pembahasan 28

4.3. Perbandingan Hasil Radiologi pada pemeriksaan Pelvis AP Menggunakan Computed Radiography dengan radiografi

Konvensional biasa 30

5. KESIMPULAN DAN SARAN 32

5.1. Kesimpulan 32

5.2. Saran 32

DAFTAR PUSTAKA 33

(10)

Gambar 2.1. Skema tabung pesawat Sinar – X 5

Gambar 2.2. Struktur imaaging Plate 10

Gambar 2.3. Struktur Lapisan Laser Imaging Film 11 Gambar 2.4 Diagram tahap akuisisi computed radiography (CR) 13 Gambar 2.5. Diagram Energi Fosfor BaFBr:Eu2+ 13 Gambar 2.6. Proses Pembacaan (Readout) dan Penghapusan

(Erasure) IP 14

Gambar 2.7. Anatomi Pelvis 18

Gambar 2.8. Phantom Rando Pria 19

Gambar 2.9. Software Image J 20

Gambar 3.1. Pesawat sinar-x merek Shimadzu ED 125 – L 21

Gambar 3.2. CR tipe Fuji 22

Gambar 3.3. Kaset IP 22

Gambar 3.4. Phantom Rhando 22

Gambar 3.5. Diagram Alir Penelitian 24

Gambar 4.1. Citra Radiografi Pelvis AP 25

Gambar 4.2. Anatomi Radiografi Pelvis AP untuk Analisa Kriteria

Penerimaan Citra dan Pengukuran PV 27

Gambar 4.3. Hubungan Eksposi (kVp, mAs) dengan Prosentase KPC

Pelvis AP 27

Gambar 4.4. Hubungan Eksposi (kVp,mAs)dengan Kontras Radiografi

Pelvis AP 28

Gambar 4.5. Optimasi Citra Pelvis AP 29

Gambar 4.6 Perbandingan Hasil Foto Rontgen CR dengan

(11)

DAFTAR TABEL

Tabel 2.1. Ukuran Pixel dan Mode Digitasi FCR Berbagai Jenis dan

Ukuran IP 15

Tabel 2.2. Kriteria Penerimaan Citra Pelvis AP 20

Tabel 4.1. Prosentase KPC dan Kontras Radiografi Pelvis AP 26 Tabel 4.2. Perbandimgan Pemeriksaan Radiografi Konvensional

(12)

DAFTAR LAMPIRAN

Lampiran 1 Hasil Uji Kualitas Citra 35

Lampiran 2 Protokol European Commision 16260 Pemeriksaan

Referensi

Dokumen terkait

PERBANDINGAN TEKNIK TEGANGAN TINGGI (KV) DENGAN TEKNIK TEGANGAN STANDAR (KV) TERHADAP NILAI EKSPOSE INDEKS PADA PEMERIKSAAN THORAX DENGAN MENGGUNAKAN.. COMPUTED

Berdasarkan hasil tersebut dapat disimpulkan bahwa usulan alternatif investasi II yaitu pencucian film radiografi dengan menggunakan Computer Radiography (CR) layak

Kajian pengolahan citra radiografi osteosarcoma lutut dan step wedge hasil Computed Radiography dimulai dari proses perataan histogram, peredaman derau serta

Soeradji Tirtonegoro dengan Paket Pemilihan Mitra Kerjasama Operasional Pengadaan Computed Radiography (CR) RSUP dr.. Soeradji Tirtonegoro, melakukan

Pemeriksaan daerah abdomen sering dilakukan di instalasi radiologi RS, dengan kondisi pasien yang berbeda khususnya di Body Mass Index pemakaian tegangan tabung

Pada penelitian yang telah dilakukan, diperoleh kualitas citra gambaran radiografi dan dosis serap radiasi pada foto lumbosacral dengan menggunakan variasi faktor eksposi

Pendekatan menggunakan perbedaan ketebalan akrilik (Tabel 3.1) untuk menentukan kualitas citra terbaik pada mamografi Computed Radiography (CR) ternyata bisa

Kajian pengolahan citra radiografi osteosarcoma lutut dan step wedge hasil Computed Radiography dimulai dari proses perataan histogram, peredaman derau serta