(1)

Sehubungan dengan perubahan, penambahan dan atau pengurangan dari Dokumen Pengadaan untuk Pekerjaan Pengadaan Alat Laboratorium 1.

Built in reservoir volume : 6 L

Dok. 01.02.100.04.12.0631

1 HPLC with auto & manual injector, UV-VIS & PDA Detector *) Unit 1

Specifications : Pompa

- System Pump : Binary and Quaternary

No. PR.01.02.100.04.12.0631 tanggal 9 April 2012 terdapat perubahan pada spesifikasi teknis sebagai berikut : No. 5. Aqua Reverse Osmosis System

Point g. dihilangkan

Terlampir Spesifikasi Teknis Pengadaan Alat Laboratorium setelah addendum 1 dan 2

Tanggal 18 April 2012

PANITIA PENGADAAN BARANG DAN JASA PENGADAAN ALAT LABORATORIUM

BALAI BESAR PENGAWAS OBAT DAN MAKANAN DI BANJARMASIN ADDENDUM II LAMPIRAN SPESIFIKASI TEKNIS

PENGADAAN ALAT LABORATORIUM No. 01.02.100.04.12.0700

Lampiran Spesifikasi Teknis

PENGADAAN ALAT LABORATORIUM BALAI BESAR POM di BANJARMASIN RINCIAN SPESIFIKASI TEKNIS PENGADAAN ALAT TAHUN 2012

(2)

- Flow rate setting range : 0.001mL/min. to 10 mL/min.

- Flow rate accuray :

- Flow rate precission : ≤ . %

- Number of solvent mixed : minimal 4

- Mixing - concentration accuracy : ≤ . % Detektor uv-vis

- Light source : D2 lamp

- Wavelength range : 190-700 nm or wider

- Wavelength accuracy : ± 1 nm

- Wavelength precision : ± 0,1 nm

- Funtion : Dual Wavelenght

- Linearity : 2.5 AU

Detektor Photo Array Detector

- Light source : D2 lamp, Tungsten (W) lamp

- Number of diode elements : min 512

- Wavelength range : 190-800 nm or wider

- Wavelength accuracy : ± 1 nm

- Wavelength precision : ± 0,1 nm

- Funtion : contour output, spectrum library

- Linearity : 2.0 AU

Column Oven

- Temperature setting range :

- Temperatur control precision : ≤ , o

C

- Coulumn storage : min 4 columns

Autosampler

- Injection Precision : < 0,5% or better

- Injection volume : 0,1-100 uL

- Number of sample vials : minimal 100 vial@±1-2 ml

- Sample carryover :

Manual injector : 1 unit

Number of connectable units : min 8 units

≤ %

4°C to 80°C or wider

min 0.01%

(3)

Computer

Data Analysis & Reporting for food and drug analysis. Include :

a. Maintenance Kit for Pump b. Auto rinsing kit for Pump c. Mixer SUS

d. Sample vial, 1 - 2ml (100pc/ pk) min 2 pkg e. Micro syringe 100 uL 1 pcs

f. C18 Coulumn 4.6x250 mm, 5 um min 3 pcs g. C 8 Coulumn 4.6x250 mm, 5 um min 2 pcs h. Check valve inlet min 2 pcs

i. HUB W/ Cable j. Tools Kit k. UPS 5 KVA l. Reservoir Tray m. Instalasi n. Training

o. Original manual book p. Factory cerificate q. Guarantee min 1 year

2 HPLC with auto & manual injector, UV-VIS Detector with manual loop 500µl *) Unit 1

Specifications :

- System Pump : Binary and Quaternary

- Flow rate setting range : 0.001mL/min. to 10 mL/min.

- Flow rate accuray :

- Flow rate precission : ≤ . %

- Number of solvent mixed : minimal 4

- Mixing - concentration accuracy : ≤ . % Detektor uv-vis

≤ %

(4)

- Light source : D2 lamp

- Wavelength range : 190-700 nm or wider

- Wavelength accuracy : ± 1 nm

- Wavelength precision : ± 0,1 nm

- Funtion : Dual Wavelenght

- Linearity : 2.5 AU

Column Oven

- Temperature setting range :

- Temperatur control precision : ≤ , o

C

- Coulumn storage : min 4 columns

Autosampler

- Injection Precision : < 0,5% or better

- Injection volume : 0,1-100 uL

- Number of sample vials : minimal 100 vial@±1-2 ml

- Sample carryover :

Manual injector

Number of connectable units : min 8 units

Computer

Include :

a. Maintenance Kit for Pump b. Auto rinsing kit for Pump c. Mixer SUS

d. Sample vial, 1 - 2ml (100pc/ pk) min 2 pkg e. Micro syringe 100 uL 1 pcs

f. C18 Coulumn 4.6x250 mm, 5 um min 2 pcs

Min Intel Core i3-2100 Processor, 4GB DDR3, Windows 7 Professional 32-bit, HDD 500GB, DVD RW, Intel Graphics Media Accelerator (GMA) X4500HD,intel G-41 chipset, USB Optical Mouse , USB Keyboard, , Monitor LCD 18,50", Laser colour printer, USB 2 port

Data Analysis & Reporting for food and drug

4°C to 80°C or wider

min 0.01%

(5)

g. C 8 Coulumn 4.6x250 mm, 5 um min 2 pcs h. C18 Coulumn 4.6x150 mm, 5 um min 1 pcs i. Check valve inlet min 2 pcs

j. HUB W/ Cable k. Tools Kit l UPS 5 KVA m. Reservoir Tray

n. Sample loop 500µl for manual ijnector o. Instalasi

p. Training

q. Original manual book r. Factory cerificate s. Guarantee min 1 year

3 HPLC with autosampler, UV-VIS Detector *) Unit 2

Specifications : Pompa

- System Pump : Quaternary

- Flow rate setting range : 0.000 mL/min. to 10.000 mL/min. (0.050 to 5.000 mL/ min typical)

- Flow rate accuray :

- Flow rate precission : ≤ . %

- Gradient for easy method development : min 10 gradient curves function

- Number of solvent mixed : minimal 4

- Mixing - concentration accuracy : ≤ . % Detektor UV-Vis

- Light source : D2 lamp

- Wavelength range : 190-700 nm or wider

- Wavelength accuracy : ± 1 nm

- Wavelength precision : ± 0,1 nm

- Flow cell design :

- Funtion : Dual Wavelenght

≤ %

(6)

- Linearity : 2.5 AU

- Lamp optimization :

Column Oven

- Temperature setting range :

- Coulumn storage : min 2 columns

Autosampler

- Injection volume : 0,1-100 uL

- Number of sample vials : minimal 100 vial@±1-2 ml

- Sample carryover :

- Injection Precision : < 0,5% or better

Computer

Include :

a. Tool kit

b. C18 Coulumn 4.6x250 mm, 5 um min 2 pcs c. C18 Guard Coulumn 4.6x20 mm, 5 um min 2 pcs d. Sample/standard filtration, Ø 13 mm 0.45 µm e. Sample vial, 1 - 2ml (100pc/ pk) min 1 pkg f UPS 2 KVA

g. Instalasi h. Training

i. Original manual book and software j. Factory cerificate

k. Guarantee min 1 year

4 Aquadestillata (Glass-Destilation) *) unit 1

Spesification

20°C to 65°C or wider

min 0.1%

Min Intel Core i3-2100 Processor, 4GB DDR3, Windows 7 Professional 32-bit, HDD 500GB, DVD RW, Intel Graphics Media Accelerator (GMA) X4500HD,intel G-41 chipset, USB Optical Mouse , USB Keyboard, , Monitor LCD 18,50", Laser colour printer, USB 2 port

Data Analysis & Reporting for food and drug analysis.

(7)

a. Capacity : min. 8 L/ hour b. Cooling water requirement : ± 144 L/ hour

c. Conductivity : ± 2.2 µs/cm at 20°C

d. Evaporator material : borosilicate glass

e. Condensor material : borosilicate glass

f. Heating element material : Quartz sheathing

g. Low water cut off : in condensor, auto power cut off

h. Energy saving : through distillation of heated cooling water

i. Distillate withdrawl : Right hand side

j. Cooling water outlet : Ø 12.7 mm

k. Impurity detector : Automatic

l. Housing : Galvanized steel, powder coated with epoxy resin

m. Cooling water pressure : > 3-7 bar

n Dimension (WxDxH) : max 650 x 365 x 390

o. Power input : 400 V/ 50-60 Hz

p. Electrical consumption : max. 6.0 kW

q. Another features : - Electronic impurity detector by automatic water change - Water saving through automatic water cut-off

- Sterillisation of the condensers by steam - CO2 degassing through outlet in the condenser

Included of

- Wall or bench mounting - Instalation

- Guarantee min 1 year

- Original operational manual book

5 Aqua reverse Osmosis System *) unit 1

Spesification

a. Nominal permeate flow : min 16 L/h

b. Product water volume : 160 to 320 L/day

b. Inlet feed water : tap water

(8)

c. Ionic content rejection : > 96 %

d. Organics, particulate : > 99 %

microorganism rejection

e. Dimension (HxWxD) : max. 45.7 x 25.5 x 31.5 cm

f. Operating weight : max 15 kg

g. Electrical feed voltage : 220 - 240 V h. Tap (feed) water connection : 1/2" Gaz M i. Tap (feed) water pressure : 0.5 - 6 bar

j. Water quality : type 3

Accessories/catridge used

- RO membrane catridge (2 pcs) - Sanitization chlorine tablet (2 pack) - Vent filter for PE reservoir (2 pcs) - Pretreatment kit (2 pcs)

- 100 L PE reservoir (1 pc) - 1200 L tank (1 pc) - Water pump (1 pc) Included of

- Installation

- Guarantee min. 1 year

- Original operational manual book

6 Thermocouple datalogger with printer unit 2

Spesification

a. Temperature Range & accuracy : min. -200-1370o

C ± 0.3 %rdg + 0.7 o C

b. Resolution : max. 0.1 o

C

c. Class : K

d. Display : Digital, triple display T1, T2, T1-T2

e. Environment operation : - 20-50 o

C ; RH < 90%

f. Measurement channels : min.2

g. Display of temperature : in degrees Celcius or Fahrenheit

(9)

i. Include :

- thermocouple probe (2 unit) which compatible with apparatus and measured temperature - calibration features

- printing paper rol j. Include

- Guarantee min. 1 year - Original operation manual

7 Biosafety Cabinet *) Unit 1

Specifications

a. Type : class II

b. External dimension : max 1420 x 815 x 1540 mm

c. Main control : Digital microprocessor control system

d. Air flow velocity : Inflow 0.45 m/s

e. Display : digital display

f. Main filter : ULPA filter effisiency min : 99.999%

g. Cabinet construction : electrogalvanized steel with antomicrobial coating h. Sound emision : < 53.5 dBA (EN 12469) & <58.5 dBA (NSF 49)

i. Power : 220-240V, 50 Hz

Incuded of : - UV Lamp - Support Stand - Electric outlet - Instalation - Training

- Guarantee min. 1 year - 0riginal operation manual

8 Incubator *) unit 1

Specification :

a. Capacity : Min 416 L

b. Temperature range : min 5o

C above ambient to + 70oC

c. Resolution : 0.1 o

(10)

d. Display :

e. Material :

f. Temperature controller : Micropocessor PID

g. Temperatur sensor :

h. Temperature System : triple overtemperature protection

i. Timer :

j. Power supply :

k. External dimension :

l. Accessories : 2 stainless steel grids

Included of : - Instalation - Training

- Guarantee min 1 year - Original operation Manual

9 Waterbath *) Unit 2

a. Capacity : minimal 22 L

b. Material : Stainless steel, corrosion resistant

c. Temperature range : 5oC above ambient to 95oC or higher

d. Temperature control : PID Microprosessor

e. Display : LED-digital

f. Temperature sensor : single PT 100 sensor class A in 4 -wire circuit

g. Temperature system : double overtemperature protection

h. Timer : integrated digital timer from 1 minutes to 99.59 hours

i. Powerl supply : 220 - 230 V, 50/60 Hz

j. External Dimension : max 578 x 436 x 296 mm

k. Accesories :

- Water level control Specifications :

- Flat stainless steel cover with openings and concentric ring sets minimum 6 holes(87 mm)

Digital display (LED) Stainless steel

double PT 100 sensor Class A in 4-wire circuit

Integrated digital timer with max 4 segments, each adjustable from 1 min to 999 h, with menu : delayed on, heating up, hold, cooling down

(11)

l. Included of : - Instalation

- Guarantee min. 1 year - Original operation manual

10 Gas Chromatography (GC) with detektor FID, ECD *) Unit 1

Specifications : Column Oven

- Temperature range : + 4o to ⁰ C

- Cool down rate :

- Programmability : Up to 20

- Retention time repeatibility : ≤ , % fo -de a e Injection Port

a. Split/Splitless Injection Unit ( 2 set )

- Temperature range : Room temperature +10 o

C to 400 o C or better - Pressure setting range : 0 - 900 kPa or better

- Split ratio setting range : 1-8000 or better

- Total Flow setting range : 0 -1200 mL/min or better

- Programmable steps : 7

b. Injection Unit for Widebore Column

- Temperature range : Room temperature +10°C to 400°C or better

- Pressure setting range :

- Total Flow setting range :

- Programmable steps :

Detectors

Four controlledr detectors can be installed simulatenously and individually temperature - Flame Ionization Detector (FID)

Specification :

a. Temperature range : to 400°C or higher

b. Minimum detection quantity : 1.5 pgC/s

7

˂ i utes f o °C to °C

(12)

c. Dynamic range : 107 or greater

- Electron Capture Detector(ECD) Specification :

a. Temperature range : to 350°C or higher

b. Minimum detection quantity : 6 fg/s

c. Dynamic range : 104 or greater

Autoinjector / Autosampler

a. Sample Injection Methode : Liquid sample injection via special Microsyringe.

b. Number of Samples : Minimum 100 vial @1 - 2 mL

c. Number of sample injections : 1 - 99 injections per sample.

Data Processing and Data Analysis Accessories :

- Carrier Gas Supply pipe min 2 pcs - Gas filter, molecular sieve

- He Gas + bottle - Pressure Regulator He - H2 Gas Supply Pipe - H2 Gas + bottle - Pressure Regulator H2 - Oil-less air compressor - Regulator filter

- Air filter for air compressor (silica gel) - Joint Adapter

- Air supply pipe, 2 pcs

- 10-µL microsyringe min 2 set Computer

(13)

- Capillary Column Q-Plot, 30m, 0.53mm ID, 0.25um min 1 pcs - Capillary Column DB-1, 30m, 0.25mm ID, 0.25um min 1 pcs - Capillary Column Stabilwax, 30m, 0.25mm ID, 0.25um min 1 pcs - Capillary Column DB-5, 30m, 0.25mm ID, 0.25um min 1 pcs - Capillary Cutter

- ECD Control Unit - ECD Detector Unit - N2 Gas + bottle for ECD - Presure Regulator N2 for ECD - Oxygen Trap for ECD

- AUX Temperature Control Unit - RS-232 Cable

- 1 - 2 ml Sample Vial Set with white cap & septum, 100 pcs/set min 5 set - UPS 5 KVA

- Instalation - Training

- Guarantee min. 1 year - Original operation manual - Factory Certificate

- Tool Kit

- Training to BAPETEN to get ECD license

11 Aquabidestillata (Automatic Glass Still destillation) *) unit 1

Spesification

a. Capacity : min. 3.4 L/ hour

b. Cooling water requirement : max 31 L/ hour

c. Inlet feed water : tap water

d. Water quality : ASTM type II distilled water

e. Safety devices :

f. System condensor :

g. Conductivity : +/- 1 u mhos/cm

high temperatur cut-off switch, prevents over heating and constant level device prevents boiler overfilling.

(14)

h. Power : 220-240 V/ 40-50 Hz, max 3300 watts Accessories

Automatic Collection System

a. Capacity : min 45 L

b. System : Automatic 24 hour operation for collecting water

c. Fuction :

d Component : Glass

Included of

- Wall or bench mounting - Instalation

- Guarantee min 1 year

- Original operational manual book

12 Disintegration Tester *) Unit 1

a. Number of basket : minimal one basket

b. Volume beaker : 1000 ml

c. Stroke height : 55± 2 mm

d. Speed : 30 ± 1 stroke/min

e. Display : LE digital

f. System : Automatic lift-in/out, with PT 100 temperature sensor

g. System temperature : Integrated flow-through heating system

h. Temperature accuracy : ± 2 o C

i. Included of - Instalation - Training

- Guarantee min 1 year

- Original operational manual book

13 Oven *) Unit 1

Specifications :

Specifications :

(15)

a. Capacity : minimal 53 L

b. Temperature range : 5ºC above ambient to 220ºC

c. Material : Stainless steel

d. Temperature controller : Micropocessor PID

e Display : LED-digital

f Temperature sensor : single PT 100 sensor class A in 4 -wire circuit

g. Temperature system : Double over temperature protection

h. Timer : Programmable swith off timer 1 min to 99 h 59 min or higher

i. Power supply : 220-240 V/50/60 Hz

j. External Dimension : max 550 x 680 x 480 mm

k. Accessories : 2 perforated stainless steel shelves

l Included of :

-- Instalation - Training

- Guarantee min 1 year - Original operation Manual

12 Top Loading Balance with Printer Unit 1

Specifications:

a. Capacity : max 2200 gram

b. Min. Display :

c. Repeatability :

d. Linearity :

e. Response Time :

f. Pan Size : max 170 x 180 mm

g. Display :

h. Printer Function :

Included of : - Instalation

1.5 - 2.5 second

LCD with backlight

Statistic calculations, output (PRINT) command, TARE command, date and time printing* (can be printed automatically for each

easu e e t esult, ased o the ala e’s i te al lo k , ID printing, sample number (automatic incrementation) printing, multiplication, comparator, autoprint, ON/OFF command for 0.01 gram

(16)

- Guarantee min 1 year

- Original operation Manual

15 Stirring Hotplate Unit 3

Spesification

a. Plate dimension :

b. Material :

c. Temperature range :

d. Temperatur display : digital

e. Stirring speed :

f. Controller :

g. Power :

h. Complete with :

Included :

- Guarantee min. 1 year - Original operation manual

16 Trinocular Microscope Unit 1

Spesifications :

- Viewing Heads

- Eyepieces

Paired DIN KHW 10x, FN - Objective Changer

Smooth operating, ball bearing mounted, quadruple nosepiece - Objectives

S. Flat Achromats, SM Planachromats, Planachromats, or phase contrast - Stage

Attached mechanical stage : 120 mm x 140 mm surface with 75 mm (X) by 40 mm (Y) movement, graduated with vernier readings to 0.1 mm, drop down right or left handed controls

min 60 - 1200 rpm Microprocessor 220 V/50Hz - 1700 watts one teflon stirbar

A rugged time tested design with true Kohler ilumination and high quality optics, suitable for day to day use in the laboratory. The options below are combined into twelve standard configurations to suit a wide range of biological applications and budgets

Available with standard binocular heads or trinocular heads for photomicrography, 30 o inclined eyetubes with adjustable

diopter settings and interpupilarrydistance, 360 o rotatable

Minimal 18.4 x 18.4 cm Ceramics

(17)

- Condensers

- Illuminator

Built in 6 V 300 W, variable intensity Koehler illumination for apertures up to 1.25 Head : Trinoculer

Eyepieces : KHW 10 x FN 20

Objectives : SM Plan Brightfield 4 x, 10 x, S40 x, S 100 x oil Mech stages : Attached

Condensers : Achromatic NA 1.25 with blue filter Illumination : Koehler 6 V 30 W halogen

Accessories

- USB 2.0 Camera 1.5 megapixel camera

Samples : 15 fps at full 1440x1080 resolution and 60 fds at 640x480 - Mount adapter with 0.5 x lens

- Personal computer

Included

- Guarantee 1 year - Instalation - Training

- Original operation Manual

Attached mechanical stage : 120 mm x 140 mm surface with 75 mm (X) by 40 mm (Y) movement, graduated with vernier readings to 0.1 mm, drop down right or left handed controls

Flat top stage : 171 mm x 140 mm surface with 80 mm (X) by 52 mm (Y) movement, graduated with vernier readings to 0.1 mm, detachable speciment quide, drop down right of handed controls.

Standard models have either an Achromatic NA 1.25 condenser with iris diaphragm and filter tray for brighfiel work, simple NA 1.25 slider phase condenser, or an NA 1.25 Zernike phase condenser with filter tray and independently centerable annuli for phase contrast. Cardioid type NA 1.25 darkfield condenser for high power ( 100x objective only) darkfield work is optional

High speed USB 2.0 interface eliminates a framegrabber and facilitates ease of instalation on both laptop and dekstop computers. Infinity Capture software application included.

Max compatible, on board-image processing of the infinit lite's progressive scan 1.5 megapixel image sensor result in accurate color fidelity

(18)

17 Oven *) Unit 1

a. Capacity : minimal 256 L

b. Temperature range : 5ºC above ambient to 250ºC

c. Material : Stainless steel

d. Temperature controller : Micropocessor PID

e. Display : LED-digital

f. Temperature sensor : double PT 100 sensor class A in 4 -wire circuit

g. Temperature system : triple overtemperature protection

h. Timer : Integrated digital timer with max 4 segments, each adjustable from 1 min to 999 h with menu : delayed on, heating up, hold, cooling down

i. Power supply : 220-240 V/50/60 Hz

j. External Dimension : max 950 x 920 x 650 mm

k. Accessories : 2 stainless steel grids

l Included of :

-- Instalation - Training

- Guarantee min 1 year - Original operation Manual

18 Unit 1

Specifications :

Evaporation from drips and open containers contributes considerably to poor quality within laboratory. This cabinets removes vapours, purifies air and enchances the long-term health of laboratory personel

a. Filter Type : H +, for handlings where acid vapours predominate secondly organic vapour, completely with blower

b. Filtration efficiency : accompliance with AFNOR NF X15-211 Class II standard

c. Instalation : No ducting, mounted to the wall

d. Noise & power :

e. Material : Galvanized steel, coated with chemical resistance epoxy-polyester paint

f. External Dimension (WxDxH) :

g. Storage Capacity :

Specifications :

Mini Chemical Storage Cabinet

uite ope atio , ≤ dBA a d low powe o su ptio

(19)

h. Volume of air treated :

i. :

j. Power consumption :

k. Acessories and standard equipment :

Include of :

- Guarantee min. 1 year - Original operation manual - Installation process

19 Unit 1

Specifications :

Evaporation from drips and open containers contributes considerably to poor quality within the laboratory. This cabinets removes vapours, purifies air and enchances the long-term health of laboratory personel

a. Filter Type : H +, for handlings where acid vapours predominate secondly organics vapour, completely with blower

b. Filtration efficiency : accompliance with AFNOR NF X15-211 Class II standard

c. Instalation : No ducting, standing

d. Noise & power :

e. Material :

f. External/ Internal Dimension (WxDxH) :

g. Storage Capacity :

h. Number of adjustable shelves : 4

i. Volume of air treated :

j. Air exchange :

k. Power consumption :

l. Power voltage/ frequency :

m. Blowers : 1 (turbine type)

min 800 x 505 x 2150 mm/ 700 x 425 x 1780 mm about 100 x 1L bottles

90 m3/ h

min. 180 times/ min max. 48 watt 220-230 V/ 50-60 Hz - Adjustable shelves

- Spill tray 2x2 L with absorption - Sliding doors

Chemical Storage Cabinet (Middle capacity, single door)

uite ope atio , ≤ dBA a d low powe o su ptio

Galvanized steel, coated with chemical resistance epoxy-polyester paint

Air exchange min. 9.9 times/ min

max. 25 watt - Partition wall

- Manual detection kit includes pump and tubing to test filter - Rewriteable sticker

(20)

n. Retention capacity based on CCl4 : 1050 g

o. Weight of the packed unit :

p. Acessories and standard equipment :

Include of :

- Guarantee min. 1 year - Original operation manual - Installation process

20 Unit 2

Specifications :

Evaporation from drips and open containers contributes considerably to poor quality within the laboratory. This cabinets removes vapours, purifies air and enchances the long-term health of laboratory personel

a. Filter Type : H +, for handlings where acid vapours predominate secondly organics vapour, completely with blower

b. Filtration efficiency : accompliance with AFNOR NF X15-211 Class II standard

c. Instalation : No ducting, standing

d. Noise & power :

e. Material :

f. External/ Internal Dimension (WxDxH) :

g. Storage Capacity :

h. Number of adjustable shelves : 8

i. Volume of air treated : 90 m3/ h

- Filter saturation electronic alarm for solvents

Chemical Storage Cabinet (Large capacity, double door)

uite ope atio , ≤ dBA a d low powe o su ptio

Galvanized steel, coated with chemical resistance epoxy-polyester paint

min 1600 x 505 x 2150 mm/ 1400 x 425 x 1780 mm about 200 x 1L bottles

- Spill tray 3 L with absorption - Doors lock

- Retaining tray - 1 x HCl box - Magnetic labels

- Guide of filtered chemical (chemical listing) max.155 kg

- Fan failure alarm

- Manual detection kit includes pump and tubing to test filter - Rewriteable sticker

(21)

j. Air exchange :

k. Power consumption :

l. Power voltage/ frequency :

m. Blowers :

n. Retention capacity based on CCl4 : 1050 g

o. Weight of the packed unit :

p. Acessories and standard equipment :

Include of :

- Guarantee min. 1 year - Original operation manual - Installation process

21 Safety Cabinet (Yellow) For Flammable Unit 2

Specification :

a. Material :

b. Construction :

c. Load capacity : 90 gallon/ 159 kg

d. Complience with : OSHA and NFPA standards, and most are FM approved

Compact 3-point stainless steel bullet self-latching system and welded construction

- Retaining tray - 1 x HCl box - Magnetic labels

- Guide of filtered chemical (chemical listing) - Filter saturation electronic alarm for solvents

Galvanized steel min. 51 mm, fully painted inside-outside with a durable lead free epoxy/ polyester powder paint for chemical resistance.

- Fan failure alarm

- Manual detection kit includes pump and tubing to test filter - Rewriteable sticker

- Adjustable shelves

- Spill tray 6 L with absorption - Doors lock

(22)

e. Safety device : - dual vents with flame arresters

- paddle handle with slip resistant - fail safe closing mechanism.

f. Dimensions : H x W x D : min 1651 x 1092 x 864 mm

g. No. of shelves / door : 2/2

Included :

- Instalation

- Guarantee min. 1 year - Original operation manual

22 Laboratory Centrifuge *) Unit 1

Technical Specification :

a. Power supply : 220-240 V/ 50-60 Hz

b. Power consumption :

c. Emmision : accomplience with EN/ IEC 61326-1

d. Immunity : Class B

e. Capacity unit maximal : 4 x 50 ml and 32 x 15 ml f. Speed RPM, RCF Unit maximal : 6000 min, 4.226

g. Running time : min. 1-99 min

h. Dimension : H x W x D : max. 257 x 366 x 430 mm

i. weight, approx : max. 25 kg

j. Swing out rotor : min. 4 place in 1 unit

k. Suspensions/ Bucket for 15 ml : min. 4 pcs l. Suspensions/ Bucket for 50 ml : min. 4 pcs General Specification :

a. CE Conformity IEC 61010 &ISO Certified 9001 : 2000 b. RPM input in increment of 100

- Shut and latch automatically when fusible link melt at 165°F (74°C) under fire conditions

- double-walled steel with 38 mm of insulating air space for fire resistance

(23)

c. Imbalance Switch off/ Automatic rotor d. Viewing port in the lid

e. Inner lid of stainlees steel f. Metal Housing Finished

g. Deep drawn centrifuge chamber of stainlees steel Included :

- Guarantee min. 1 year - Original operation manual - Instalasi

- Training

23 Digital Abbe refraktometer Unit 1

a. Measurement range : nD, 13000 - 17100

b. Minimum scale : nD 0.0001, Brix 0.1 %

c. Measurement accuracy : nD ± 0.0002, Brix± 0.1 %

d. Measurement temperatur range : 5 - 50 o C

e. Light source : LED Lamp

f Power supply : 100 to 240 V

- Test piece

- Monobromonaphthalene - Lighting adapter

- Tube band Incuded of

- Guarantee min. 1 year - Gu0riginal operation manual

24 Vaccum Oven *) Unit 1

Specifications :

Brix 0.0 - 95.0% (automatic Temperature compensation is

executed at 5-50o C)

(24)

INTERIOR

a. Volume : min 29 L

b Dimension (Width/ Height/ Depth) :

c. Maximum number of thermoshelves : 3

d. Distance between thermoshelves : 75 mm

e. :

f. Material :

EXTERIOR

a. Dimension (Width/ Height/ Depth) :

b. Safety glass door :

c. Door seal : Endless silicone profile seal

d. Material : Stainless steel (rear zinc-plated steel)

OVEN TEMPERATURE CONTROL

a. Temperature controller : Eectronic microprocessor temperature controller

b. Temperature sensor :

c. Temperature range : min. 20 up to 200° C

d. Resolution of display and setting accuracy : 0.5° C below 99.9° C and 1° C above 100° C

e. Temperature variation in time : ≤ ± . ° C

f. Temperature uniformity (surface) at 160° C/ 50 mbar : ≤ ± ° C g. Autodiagnostic system with fault indication

VACUUM CONTROL

a. Vacuum control : digital electronic through selenoid valves up to 40 ramps

b. Adjustable pressure : 10 - 1100 mbar

c. Resolution : 1 mbar

d. Digital display of actual pressure : from 5 mbar up to 1100 mbar

e. Permitted final vacuum : 0.01 mbar

f. Maximum leakage rate : 0.01 bar/ h

g. Another features :

Textured stainless steel frame with spring-loaded safety glass on

Temperature measured through 4-wire Pt100 Class A individually for each thermoshelves

- Tubing for vacuum, air and inert gas are made of material 1.4571 (ASTM 316 Ti)

- Two programmable, alternatively selectable and digitally controlled inlets (for air and inert gas)

- Integrated drying process control with programmable temperature and vacuum cycles

max. 385 x 505 x 250 mm

Maximum load per shelf/ per oven min. 20/ 40 kg

stainless steel material 1.4404 (ASTM 316 L) electropolished

(25)

- Signal for pump module (ON/ OFF, purging)

- Noise absorbing vacuum pump with integrated pump

TIMER FUNCTIONS

a. Timer with residual running time : max. 40 ramps

b. Timer range adjustable : 1 min up to 999 hours

c. Real time / weekly programmer with group function MONITOR

a. Display : digital display (LED) of all set parameter

b. Secure with :

- Digital over- and undertemperature monitor

- Relay for reliable heating cut-off of faultin case - Acoustic alarm : over- and undertemperature

c. Documentation :

GENERAL

a. Electrical supply : 220-240 V/ 50-60 Hz

b. Electrical load : max. 1200 watt

c. Net weight/ Gross weight : 58/ 64 kg

d. Accessories : - Removable interior mounting-stainlees steel material

- Removable bottom drip tray- stainlees steel material - Works calibration certificate

- Additional thermoshelves of stainlees steel material including local temperature sensing (Pt 100, 4 wire circuit)

- Chemically resistant vacuum pump with PTFE double diaphragm and automatic purge process through controller

- Microprocessor temperature protection, incorporating fault diagnostic with visual and acoustic alarm

- Temperature monitoring band automatically linked to the setpoint (ASF)

- Multi Level Overtemperature Protection (MLOP) for each thermoshelf

- Min. internal log memory 1024 kB as ring memory for all setpoints

- Software for control and documentation of temperature and pressure

- Integrated drying process control with programmable temperature and vacuum cycles

(26)

- Converter cable to printer

- Oven-linked authorisation card (User-ID-Card) Include of :

- Guarantee min. 1 year (for oven) and 2 year (for vacuum pump) - Original operation manual

- Installation

25 4.0 Vertical Auto-desiccator cabinets Unit 1

Protecting valuable humidity-sensitive items, such as reagents. It's full automatic system. electronic dehumidification system that automatically regenerates the desiccant and reduces the relative humidity to about 25% within 8 hours A hygrometer dial in the door allows for easy monitoring of relative humidity.

Spesification

a. Material :

b. Range of humidity control :

c. Power supply :

d. Internal Volume :

e. Dimension (HxWxD) :

f. Color : Clear

g. Accessories :

- 3 perforated shelves that are removable

h. Include

- Instalation

- Guarantee min. 1 year - Original operation manual

26 Ultrapure Water System (AQUADEMINERALISATA) *) Unit 1

Spesification

a. Production flow rate : min 8 L/h

b. Dimension (H x W x D) : 54 x 29 x 38 cm

- 2 latches and loops for lock or tamper evident seal

- Additional thermoshelves of stainlees steel material including local temperature sensing (Pt 100, 4 wire circuit)

Co-polyester plastic up to 25% RH 230 V AC 1.9 cu feet

(27)

Net weight with UV lamp : 7.6 kg

c. Electrical feed voltage : 100-230 V, 50-60 Hz d. Tap feed water connection : 1/2 Gaz M

e. Tap water pressure : 0.5 to 6 bar

Type 1 Product Water Quality

a. Resistivity : 18.2 MΩ at o C

b. Instant flow rate : > 0.5 L/min

c. TOC : ≤ pp µg/l

d. Bacteria/particulate : < 0.1 cfu/ml

e. Pyrogens : < 0.001 eu/ml

f. Rnases : < 0.01 ng/ml

g. DNases : < 4 pg/µl

Type 3 Product Water Quality

a. Ionic rejection : > 96%

b. Organic injection : > 99%

c. Bacteria and particulates : > 99%

Available System Configuration - With UV 185/254 nm - Remote dispenser

Accessories

- Wall mounting bracket with tap

- Tank connection kit for connecting apparatus to the tank. - 60 L PE reservoir (1 ps)

(28)

- Pretreatment cartridge for RO (4 pcs)

- Pretreatment cartridge with activated carbon and ion exchange (4 pcs) - Filter unit 0.22 µm (2 box)

Included

- Installation

- Guarantee min.1 year

- Original operational manual book

27 2.0 Auto desiccator cabinets Unit 3

A hygrometer dial in the door allows for easy monitoring of relative humidity. Spesification

a. Material :

b. Range of humidity control :

c. Power supply :

d. Internal Volume :

e. Dimension (HxWxD) :

f. Color : Clear

g. Accessories :

- 2 perforated shelves that are removable h. Include

- Instalation

- Guarantee min. 1 year - Original operation manual

28 DEHUMIDIFIER Unit 4

Specifications :

a. Air flow fast : minimum 270 sqm/hr

b. Air flow slow : minimum 150 sqm/hr

c. Weight : min 26 kg

31.4 x 34.1 x 41.4 cm

- 2 latches and loops for lock or tamper evident seal Protecting valuable humidity-sensitive items, such as reagents. It's full automatic system. electronic dehumidification systemthat automatically regenerates the desiccant and reduces the relative humidity to about 25% within 8 hours

(29)

d. Temperature operating range : to ⁰C

e. Humidity : 20% to 80%

f. Dimension (L x W x H) : min 34.3 cm x 40.6 cm x 52.7 cm

g. Water container capacity : min 7 Liter

h. Power consumption : max. 600 watt

i. Power supply : 220 - 240 V; 50/60Hz

Consisting of :

j. Adjustable and automatic humidity controller k. Frost guard

l. Automatic switch off when water container is full m. Corrosion protection

n. R134 a refrigerant (CFC Free)

- Original operation manual - Guarantee min. 1 year

TTd

Panitia Pengadaan Alat Laboratorium Balai Besar POM di Banjarmasin Tahun Anggaran 2012

Included of

(30)
(31)
(32)
(33)
(34)
(35)
(36)
(37)
(38)
(39)
(40)
(41)
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
(51)
(52)
(53)
(54)
(55)
(56)
(57)
(58)
(59)

Referensi

Garis besar

Dokumen terkait

Tata cara ULP perihal tahapan pengumuman lelang dan penetapan pemenang secara bersama-sama (Collective collegial);.. Mendukung proses lelang pasca 1 File dan lelang pasca 2

ditentukan dalam ayat (1) dan (2) di atas, maka Pengguna Jasa hanya berkewajiban untuk membayar kepada Penyedia Jasa jumlah uang (setelah dikurangi dengan jumlah yang telah

electronic dehumidification system that automatically regenerates the desiccant and reduces the relative humidity to about 25% within 8 hours A hygrometer dial in the door allows

Sehubungan dengan point 1 dan 2 tersebut di atas Pokja Pengadaan Barang Balai Besar POM di Pekanbaru memutuskan bahwa Pelelangan Pekerjaan Pengadaan Suku Cadang pada BBPOM

Land cost Rs 97.2 million 10 % of Equipment cost 3 Total installation cost Rs 106.92 million 4 Annual capacity factor 23 % From initial year of operation 5 Annual operation and

Evaporate off the solvent using the rotary evaporator, dry up using a rotary vacuum pump for 5 mins, cool in desiccator for another 30 min and weigh the neutral lipids.. Drain off with

This study described a phantom validation to 1 Set a scale reference for both clinical manual operation and future machine learning in terms of measuring pancreatic fat fraction; 2

The document provides safety instructions and guidelines for the installation, operation, and maintenance of external relief valves for H100 Series