On your rail, get set, go:
The new, rugged rail switches
from Hirschmann.
• Rugged Fast-ETHERNET rail switch
• New design with metal housing
• DIN rail or wall mounted
• Modular design for maximum versatility
Built to take the punishment:
The rugged new rail switches.
Applications
When the going gets tough for DIN rail switches
(i. e. shock, vibration and temperatures fluctuating
between – 40° C and + 85° C), the rugged new
Hirschmann rail switches deliver the performance
you need. Hirschmann rail switches are built to
take the punishment in marine, rail, road and other
transportation automation applications including
fiberoptic rail networks, train station passenger
information systems, conveyors and airport runway
lights. Other examples include traffic surveillance
on superhighways, bridges or in tunnels, toll collection
systems as well as video on demand and air conditioning
systems onboard ocean-going liners. Industrial
ETHERNET is rapidly becoming the standard solution
in military applications, and the new Hirschmann rail
switches are an excellent choice for systems onboard
navy ships and aircraft carriers.
All of this is available as a robust complete solution,
for example in combination with the MACH 1000.
MACH 1000
Long-term
availability
MACH 1000
Extreme flexibility
RSR
HIPER-Ring 2
< 10 ms
RFI-/EMI immunity
RSR
Extended
temperature
range
RSR
Long-term
reliability
RSR
Hirschmann rail switches:
The ideal enhancement to the MACH 1000.
Power and performance: the MACH 1000.
• Extremely high EMI immunity
• Shock and vibration protection
• Modular design for maximum versatility
• Extended temperature range: – 40° C up to + 85° C
• Compact design, high port density, up to 26 ports
• Simple, user-friendly ring configuration
Requirements and Solutions
The new Hirschmann rail switches deliver excellent
performance in substations and any other applications
and environments where there is a need for extremely
rugged DIN rail switches. The new Hirschmann family
is the solution of choice whenever rugged design,
long-term reliability and very good EMI immunity are
required to withstand extreme operating conditions
such as temperature, shock and vibration. The range
of applications includes marine systems, transportation
automation and extremely harsh industrial environments.
The new rugged rail switches cover the entire spectrum
from stand-alone solutions, with models ranging from
the 8-port TX to the 10-port full fiber switch, to
complete ruggedized solutions. The rail switches can
be combined with the powerful MACH1000 to create
a unique, rugged, virtually indestructible complete
package for extreme DIN rail applications. This solution
from the market leader in industrial ETHERNET offers
the OpenRail versatility and quality that you expect
Software
• OpenRail Layer 2 Professional, a powerful
software platform which offers the same
functionality for all products
Configuration
• Command Line Interface (CLI),
TELNET, BootP, DHCP,
DHCP Option 82, HiDiscovery,
Auto Configuration Adapter
(ACA21-USB)
Redundancy functions
• HIPER Ring, RSTP, redundant ring
topology, link aggregation
Security
• Port Security (MAC and IP based)
SNMP V3, Authentication (802.1x),
SSH, VLAN
Diagnostic tools
• LEDs, log file, syslog,
2 signal contacts, RMON,
port mirroring, topology
discovery, 802.1ad,
cable diagnostics (TX)
Approvals
• IEC 61850-3, IEEE 1613,
NEMA TS2,
EN 50121-4, EN 50155
Operating voltage
• Wide input range,
16,8 – 60 VDC or
48 – 320 VDC and
90 – 265 VAC
Ambient conditions
• Temperature – 40° C up to
+ 85° C
• Optional conformal coating
• Extremely high RFI/EMI
User configurable with the OpenRail System
P
Model
RSR 20 Rail Switch Rugged Fast-ETHERNET
RSR 30 Rail Switch Rugged Gigabit-ETHERNET uplink ports
Ports Fast-ETHERNET
06 6 x100 Mbit ETHERNET 07 7 x100 Mbit ETHERNET 08 8 x100 Mbit ETHERNET 09 9 x100 Mbit ETHERNET
Ports Gigabit-ETHERNET
00 0 x1000 Mbit ETHERNET 02 2 x1000 Mbit ETHERNET 03 3 x1000 Mbit ETHERNET
Ports Type 1. Uplink
CC 2 x Combo Port Gigabit-ETHERNET OO 2 x SFP Slot Gigabit-ETHERNET TT 2 x Twisted Pair (Tx) / RJ 45 MM 2 x Multimode FX SC JJ 2 x Multimode FX MTRJ NN 2 x Multimode FX ST VV 2 x Singlemode FX SC UU 2 x Singlemode FX ST
LL 2 x Singlemode Long Haul FX SC GG 2 x Singlemode Long Haul+ FX SC (200 km) ZZ 2 x SFP Slot (100 Mbit)
P
O7 Combo Port Gigabit-ETHERNET O6 SFP Slot Gigabit-ETHERNET T1 Twisted Pair (Tx)/ RJ 45 M2 Multimode FX SC M3 Multimode FX MTRJ M4 Multimode FX ST S2 Singlemode FX SC S4 Singlemode FX ST
L2 Singlemode Long Haul FX SC G2 Singlemode Long Haul+ FX SC (200 km) Z6 SFP Slot (100 Mbit)
Ports Type 2. Uplink
ZZ 2 x SFP Slot (100 Mbit) O7 Combo Port Gigabit-ETHERNET
O6 SFP Slot Gigabit-ETHERNET T1 Twisted Pair (Tx)/ RJ 45 M2 Multimode FX SC M3 Multimode FX MTRJ
M4 Multimode FX ST S2 Singlemode FX SC S4 Singlemode FX ST
L2 Singlemode Long Haul FX SC G2 Singlemode Long Haul+ FX SC (200 km) Z6 SFP Slot (100 Mbit)
Voltage range 1
C 24/36/48 V DC
K 60/120/250 V DC and 110/ 230 V AC
Voltage range 2
9 Not available C 24/36/48 V DC
K 60/120/250 V DC and 110/230 VAC
Software version
04.0.
Software release
04.0. Software release 4.0. XX.X. newest software release
Optional
R S R 3 0 - 0 9 0 2 S 2 M 2 T 1 U C C H P H H 0 4 . 0 .
RSR 30
09
Use our online tool to configure your rail switch at configurator.hirschmann.com. Avoid the hassle and the delay.
H
F Extended – 40° C up to + 85° C inclusive Conformal Coating
U
M2
S2
02
Remaining Ports
T1 Twisted Pair (Tx)/ RJ 45 Z6 SFP Slot (100 Mbit)
Approvals
H UL508; GL; IEC61850; IEEE 1613; EN 50121
C UL508; GL; IEC61850; IEEE 1613; EN 50121-4; EN50155
Rail Switch
Productname Description
Port type and quantity
More Interfaces
V.24 interfaces USB interface
Gigabit-ETHERNET Network size – length of cable
Twisted Pair (TP)
Multimode fiber (MM) 50/125 µm Multimode fiber (MM) 62.5/125 µm Singlemode fiber (SM) 9/125 µm Singlemode fiber (LH) 9/125µm
Fast ETHERNET Network size – length of cable
Twisted Pair (TP)
Multimode fiber (MM) 50/125 µm Multimode fiber (MM) 62.5/125 µm Singlemode fiber (SM) 9/125 µm Singlemode fiber (LH) 9/125µm
Network size – cascadibility
Line/star topology Ring structure (HIPER-Ring) Fault recovery time (ring)
Power requirements
Operating voltage
Current consumption at 24 V DC Current consumption at 48 V DC Current consumption at 230 VAC Power output in Btu (IT) h Protective lacquer on PCB Relative humidity (non-condensing)
Mechanical construction
IEC 60068-2-27 shock IEC 60068-2-6 vibration
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) EN 61000-4-3 electromagnetic field EN 61000-4-4 fast transients (burst) EN 61000-4-5 surge voltage
EN 61000-4-12 damped oscillatory wave EN 61000-4-16 mains frequency voltage
EMC emitted immunity
FCC CFR47 Part 15 EN 55022
Approvals
Safety of industrial control equipment Ship
Substation Transportation
RSR20-xx
ETHERNET/Fast-ETHERNET Switch
managed, industrial switch for DIN rail, store-and-forward-switching, fanless design, Software Layer 2 professional
Fast-ETHERNET ports in total: up to 9
1 x RJ 11 socket
1 x USB to connect auto-configuration adapter ACA21-USB
0 – 100 m
0 – 550 m, 7.5 dB link budget (with M-SFP-SX/LC) 0 – 275 m, 7.5 dB link budget (with M-SFP-SX/LC) 0 – 20 km, 11 dB link budget (with M-SFP-LX/LC) 16 – 80 km, 6 – 22 dB link budget (with M-SFP-LH/LC)
Serial interface, web-interface, SNMP V1/V2, HiVision file transfer SW HTTP/TFTP
LEDs, log file, syslog, signal contact, RMON, port mirroring, topology discovery 802.1AB, cable tester (TX) Comand line interface (CLI), TELNET, BootP, DHCP, DHCP option 82, HiDiscovery,
auto configuration adapter (ACA21-USB)
Port security (IP and MAC), SNMP V3, SSH, authentication (802.1x)
HIPER-Ring, RSTP 802.1w, redundant network/ring coupling, link aggregation, redundant 24 V power supplies QoS 4 classes, port priority (IEEE 802.1D/p), VLAN (IEEE 802.1Q), multicast (IGMP snooping/querier), unknown multicast detection, broadcast-, unicast-, multicast limiter, fast aging, GMRP IEEE 802.1D SNTP Server, PTP/IEEE 1588
Flow Control 802.3x
– 40° C up to + 85° C – 40° C up to + 85° C optional conformal coating 10 % up to 95 %
appr. 125 x 140 x 120 mm DIN rail and wall appr. 1 kg IP 30
15 g, 11 ms duration, 18 shocks
1 mm, (2 – 13.2 Hz), 90 min.; 0.7 g, (13.2 – 100 Hz), 90 min.; 3.5 mm, (3 – 9 Hz), 10 cycles, 1 octave/min.; 1 g, (9 – 150 Hz), 10 cycles, 1 octave/min.
8 kV contact discharge, 15 kV air discharge 35 Vpp/m (80 – 2700 MHz); 1 kHz, 80 % AM 4 kV power line, 4 kV signal- and data line
power line: 2 kV (line/earth), 1 kV (line/line) IEEE 1613: power line: 5 kV (line/earth) 2.5 kV line/earth, 1 kV line/line (1 MHz)
30 V; 50 Hz continous; 300 V, 50 Hz 1 s
FCC CFR47 Part 15 class A EN 55022 class A
cUL 508 (pending) GL optional (pending) IEEE 61850-3, IEEE 1613 NEMA TS2
RSR30-xx
ETHERNET/Fast-ETHERNET/ Gigabit-ETHERNET Switch
Gigabit-ETHERNET ports in total: up to 3; Fast-ETHERNET ports in total: up to 8
appr. 200 – 500 mA appr. 100 – 250 mA
The Hirschmann family of rail switches offers you
complete, standardized DIN rail solutions. These
user-friendly, high-reliability products reduce your
installation, configuration and maintenance costs
to a minimum.
• NEMA TS2, IEEE 1613, IEC 61850-3 and
EN 50155 compliant
• Extended temperature range: – 40° C up to + 85° C
• Fast, hassle-free DIN rail or wall mounting
• Extreme EMI immunity
• Up to 3 Gigabit-ETHERNET Ports
• Models ranging from the simple 8 TX to the
10-port fiber optic version
• Uplink ports can be configured separately
Product features
Hirschmann Competence Center
When you need cost-effective total solutions as well
as top quality products, the Hirschmann Competence
Center gives you the help you need. You get
professional consulting, service and support from the
pioneer in industrial network technology. Contact us
to discuss your specific needs.
Hirschmann. Simply a good Connection.
Production bases
Sales subsidiaries
Selected distribution partners
“The information/details in this publication merely contain general descriptions or performance factors which, when applied in an actual situation, do not always correspond with the described form, and may be amended by way of the further development of products. The desired performance factors shall only be deemed binding if these are expressly agreed on conclusion of the contract.
Please note that some characteristics of the recommended accessory parts may differ from the appropriate product. This might limit the possible operating conditions for the entire system.”
DS 280 720-064 · Edition 1 · 1107