ix
LAMPIRAN
Lampiran 1. Data Hasil Pengujian Bom Kalorimeter
Bahan
Bakar
Pengujian
T
1(
0
C) T
2(
0C)
HHV
(kJ/kg)
LHV
(kJ/kg)
LHV
RATA-RATA
(kJ/kg)
Solar
1
24,85
25,69 41870,00
38630,00
39372,00
2
25,71
26,56 42400,00
39160,00
3
26,60
27,45 42400,00
39160,00
4
27,47
28,33 42930,00
39690,00
5
28,36
29,23 43460,00
40220,00
HHV = (T
2–
T
1–
T
kp) x C
vLHV = HHV - 3240
Dimana :
HHV = Nilai kalor atas (kJ/kg)
T
1= Temperatur air pendingin sebelum penyalaan (
0C)
T
2= Temperatur air pendingin sesudah penyalaan (
0C)
C
v= Panas jenis bom kalorimeter (53000 KJ/Kg
0C)
T
kp= Kenaikan temperatur akibat kawat penyala (0,05
0C)
Beban ( Watt )
Putaran
( RPM ) Jlh silinder B (m) S (m)
Rasio
Kompresi Vd (m3) Vc (m3) ṁa (kg/jam) ηb (%) AFR
400
900 1 0,102 0,105 18,7 0,000857 0,000051 21,789 3,51 87
1000 1 0,102 0,105 18,7 0,000857 0,000051 24,21 3,96 76
1100 1 0,102 0,105 18,7 0,000857 0,000051 26,631 5,32 76
1200 1 0,102 0,105 18,7 0,000857 0,000051 29,052 6,53 79
1300 1 0,102 0,105 18,7 0,000857 0,000051 31,473 8,11 80
1400 1 0,102 0,105 18,7 0,000857 0,000051 33,894 9,23 79
Beban ( Watt )
Putaran
( RPM ) Jlh silinder B (m) S (m)
Rasio
Kompresi Vd (m3) Vc (m3) ṁa (kg/jam) ηb (%) AFR
800
900 1 0,102 0,105 18,7 0,000857 0,000051 21,789 7,45 72
1000 1 0,102 0,105 18,7 0,000857 0,000051 24,21 8,18 64
1100 1 0,102 0,105 18,7 0,000857 0,000051 26,631 9,1 61
1200 1 0,102 0,105 18,7 0,000857 0,000051 29,052 10,18 61
1300 1 0,102 0,105 18,7 0,000857 0,000051 31,473 11,48 61
Beban ( Watt )
Putaran
( RPM ) Jlh silinder B (m) S (m)
Rasio
Kompresi Vd (m3) Vc (m3) ṁa (kg/jam) ηb (%) AFR
400
900 1 0,102 0,105 18,7 0,000857 0,000051 21,789 0,81 41
1000 1 0,102 0,105 18,7 0,000857 0,000051 24,21 1,04 41
1100 1 0,102 0,105 18,7 0,000857 0,000051 26,631 1,40 41
1200 1 0,102 0,105 18,7 0,000857 0,000051 29,052 1,68 42
1300 1 0,102 0,105 18,7 0,000857 0,000051 31,473 2,07 42
1400 1 0,102 0,105 18,7 0,000857 0,000051 33,894 2,26 41
Beban ( Watt )
Putaran
( RPM ) Jlh silinder B (m) S (m)
Rasio
Kompresi Vd (m3) Vc (m3) ṁa (kg/jam) ηb (%) AFR
800
900 1 0,102 0,105 18,7 0,000857 0,000051 21,789 2,07 41
1000 1 0,102 0,105 18,7 0,000857 0,000051 24,21 2,44 40
1100 1 0,102 0,105 18,7 0,000857 0,000051 26,631 2,85 40
1200 1 0,102 0,105 18,7 0,000857 0,000051 29,052 3,17 40
1300 1 0,102 0,105 18,7 0,000857 0,000051 31,473 3,49 39
High and Low heating values from combustion of common fuel gases are indicated in the
table below:
Gas
High Heating Value
Low Heating Value
(
Btu/ft
3)
(
Btu/lb
)
(
Btu/ft
3)
(
Btu/lb
)
Ethyl alcohol saturated with water 1,548
12,804
Ethylene
1,631
21,884
1,530
20,525
Hexane
4,667
20,526
4,315
18,976
Hydrogen (H
2)
325
61,084
275
51,628
Hydrogen Sulphide
672
7,479
Landfill Gas
476
Methane - CH
41,011
23,811
910
21,433
Methyl alcohol saturated with water 818
9,603
Naphthalene
5,859
17,298
Natural Gas (typical)
950
Octane saturated with water
6,239
20,542
3,170
10,444
1 Btu/ft
3= 8.9 kcal/m
3= 3.73x10
4J/m
3
1 Btu/lb = 2,326.1 J/kg = 0.55556 kcal/kg
Volumetric Heating Values are based on standard temperatures and pressure of dry gas - 60
oF
and 14.73 psi.
Gases - Densities
Keputusan Direktur Jenderal Minyak dan Gas Bumi
Nomor : 3675 K/24/DJM/2006 Tanggal : 17 Maret 2006
SPESIFIKASI BAHAN BAKAR MINYAK JENIS MINYAK SOLAR 48
No
Satuan
Min.
Maks.
ASTM Lain
1 Bilangan Cetana :
- Angka Cetana atau - 48 - D 613 - 95
19 Penampilan visual
-20 Warna No. ASTM 3.0 D 1500
*) Khusus untuk Minyak Solar yang mengandung Bio Diesel, jenis dan spesifikasi Bio Dieselnya mengacu ketetapan Pemerintah
CATATAN UMUM :
1. Aditif harus kompatibel dengan minyak mesin (tidak menambah kekotoran mesin/kerak) Aditif yang mengandung komponen pembentuk abu (ash forming) tidak diperbolehkan. 2. Pemeliharaan secara baik untuk mengurangi kontaminasi (debu, air, bahan bakar lain, dll.) 3. Pelabelan pada pompa harus memadai dan terdefinisi.
CATATAN KAKI :
CATATAN 1 : Batasan 0.35% m/m setara dengan 3500 ppm.