12/9/2020 Email Universitas Bhayangkara Surabaya - Revised paper on Your IJEEI Manuscript No D20-10353
https://mail.google.com/mail/u/0?ik=6fe2d09444&view=pt&search=all&permthid=thread-f%3A1685105971691437694&simpl=msg-f%3A16851059716… 1/2 Amirullah Ubhara Surabaya <[email protected]>
Revised paper on Your IJEEI Manuscript No D20-10353
3 pesan
Secretary of IJEEI <[email protected]> 4 Desember 2020 07.38
Kepada: [email protected]
Dear Mrs./Mr. AMIRULLAH,
The Secretariat of International Journal on Electrical Engineering and
Informatics has received your manuscript submitted for possible publication in the Journal.
Paper ID : D20-10353 Received Date : 2020-10-20
Paper Title : Enhancing The Performace of Load Real Power Flow using Dual UPQC-Dual PV System based on Dual Fuzzy Sugeno Method
Authors : Amirullah +Adiananda+Ontoseno Penangsang+Adi Soeprijanto
Institution : Universitas Bhayangkara Surabaya+Universitas Bhayangkara Surabaya+Institut Teknologi Sepuluh Nopember Surabaya+Institut Teknologi Sepuluh Nopember Surabaya
The paper has been reviewed. Please find reviewer comments to your revised paper as follows:
Review I:
1. Please kindly put Fig. 3 after Table 1. 2. There is a numbering mistake in sub-section title of Control of Dual Series Active Filter. 3. Please kindly explain Fig. 6 to Fig. 9. Please also show legend of FS1 and FS2 in those figures. 4. There are some mistake in writing Tabel instead of Table. 5. Please kindly write symbol in italic format. 6. Please kindly put Fig.
13 in one page. 7. Please kindly put Fig. 14 in one page. 8. Please kindly put Fig. 15 in one page. 9. Please kindly put Fig. 16 in one page. 10. Please kindly show the experimental results.
Review II:
1. Figure 9 is not necessary to be included. It is a redundant information of Figures 6-8 2. It is not necessary to capture the signal from time of zero (Fig. 13-16). Please capture in a few moment before and after the disturbance. 3. Please use similar condition for PI and Fuzzy comparison. From Table 3-5, it can be seen that the authors used different voltage source in the performance comparison of the PI and Fuzzy control. 4. The system is tested under balanced load. So it is enough to show only one phase voltage or current. 5. From Figure 10, it can be seen that the UPQC-2PV-FS cannot provides better performance compared to the other configuration, especially during S-Inter-NLL and D-Inter-NLL. 6. It is not necessary to present Figure 13. The performances under D-Sag-NLL are almost similar. Difference under 2% can be assumed as similar regarding the measurement accuracy. 7. From Fig. 17, it can be seen that the 2UPQC-2PV-FS can provides better performance in term of load
real power compared to the other configuration, especially during S-Inter-NLL and D-Inter-NLL. However, in real
applications the most important is voltage which many appliances can be used only under certain voltage specification. 8.
UPQC is used to assure the load voltage to be purely sinusoidal with certain amplitude. The reviewer thought the authors ignore this. 8. The reviewer is not sure the advantage of efficiency equation (15) proposed by the authors.
Please show all revised parts in the revised paper in red sentences. Please carefully address the reviewer comments and explain all revision you have done and answer all reviewer comments or question in separate file.
Please revise your paper within 1 week.
Thank you for your interest in publishing your paper in this journal.
With best regards, The Secretariat
International Journal on Electrical Engineering and Informatics Institut Teknologi Bandung
Ganesha 10, Bandung 40132 Indonesia Email: ijeei[at]stei.itb.ac.id
12/9/2020 Email Universitas Bhayangkara Surabaya - Revised paper on Your IJEEI Manuscript No D20-10353
https://mail.google.com/mail/u/0?ik=6fe2d09444&view=pt&search=all&permthid=thread-f%3A1685105971691437694&simpl=msg-f%3A16851059716… 2/2 Website: www.ijeei.org
Amirullah Ubhara Surabaya <[email protected]> 4 Desember 2020 13.27
Kepada: Secretary of IJEEI <[email protected]>
Cc: Amirullah Ubhara Surabaya <[email protected]>
Bcc: Amirullah Ubhara Surabaya <[email protected]>
Dear Secretariat IJEEI,
Thanks a lot for the information and review.
Best Regards,
Dr. Amirullah
[Kutipan teks disembunyikan]
Amirullah Ubhara Surabaya <[email protected]> 6 Desember 2020 12.46
Kepada: Secretary of IJEEI <[email protected]>
Cc: Amirullah Ubhara Surabaya <[email protected]>
Bcc: Amirullah Ubhara Surabaya <[email protected]>
Dear IJEEI Secretariat,
From revision (Paper ID: D20-10353) by 1st reviewer, I did not fully understand the points below:
"6. Please kindly put Fig. 13 in one page. 7. Please kindly put Fig. 14 in one page. 8. Please kindly put Fig. 15 in one page. 9. Please kindly put Fig. 16 in one page."
What does that mean?
1. I have to revise all figures from double (two) columns into a single (one) column, or
2. The model (double columns) has been true but I have to add the explanation in the figure page which does not any explanation for example
page 16, page 18, page 21, page 22, and page 23.
I would be happy if you respond to the questions.
Regards,
Dr. Amirullah
Elect. Eng. Fac. Eng.
Universitas Bhayangkara Surabaya
[Kutipan teks disembunyikan]
1/5/2021 Submission - International Journal on Electrical Engineering and Informatics
www.ijeei.org/submission-page-histori.html 1/2
International Journal on
Electrical Engineering and Informatics
Printed ISSN 2085-6830/ online e-ISSN 2087-5886
Indexed by:
- SCOPUS
SCIMAGO (Q2, SJR 2019=0.19) - Google Scholar
- DOAJ - EBSCO - ProQuest
Welcome Dr. Amirullah Amirullah MENU
Paper Submission Article Processing Charge
Change Profile CV and Photos Paper History Change Password Logout