• Tidak ada hasil yang ditemukan

Inverter Waveforms for Different Modulation Indices

N/A
N/A
1ATEN@ 17_ M Zaki Fatharani

Academic year: 2024

Membagikan "Inverter Waveforms for Different Modulation Indices"

Copied!
17
0
0

Teks penuh

(1)

Muhammad Zaki Fatharani 211711017

3A-TEN

Tugas Elektronika Daya Lanjut

Gambar rangkaian full bridge

Gambar rangkaian cascaded multicells (5 level)

(2)

Indeks modulasi 0,6 Full Bridge

Vref = 220 V Vcarrier = 366,67 V Fref = 50 Hz Fcarrier = 500 Hz

- Gelombang Vref dan Vcarrier

- Gelombang Vt

(3)

- Gelombang It

Cascaded Multicells (5 level)

Vref = 220 V Vcarrier = 183.34 Vpp Fref = 50 Hz Fcarrier = 500 Hz

- Gelombang Vref dan Vcarrier

(4)

- Gelombang Vt

- Gelombang It

Indeks modulasi 0,8 Full Bridge

Vref = 220 V Vcarrier = 275 V Fref = 50 Hz Fcarrier = 450 Hz

(5)

- Gelombang Vref dan Vcarrier

- Gelombang Vt

(6)

- Gelombang It

Cascaded Multicells (5 level)

Vref = 220 V Vcarrier = 137.5 Vpp Fref = 50 Hz Fcarrier = 450 Hz

- Gelombang Vref dan Vcarrier

(7)

- Gelombang Vt

- Gelombang It

Indeks modulasi 1 Full Bridge

Vref = 220 V Vcarrier = 220 V Fref = 50 Hz Fcarrier = 251 Hz

(8)

- Gelombang Vref dan Vcarrier

- Gelombang Vt

(9)

- Gelombang It

Cascaded Multicells (5 level)

Vref = 220 V Vcarrier = 110 Vpp Fref = 50 Hz Fcarrier = 251 Hz

- Gelombang Vref dan Vcarrier

(10)

- Gelombang Vt

- Gelombang It

Indeks modulasi 1,2 Full Bridge

Vref = 220 V Vcarrier = 183,33 V Fref = 50 Hz Fcarrier = 650 Hz

(11)

- Gelombang Vref dan Vcarrier

- Gelombang Vt

(12)

- Gelombang It

Cascaded Multicells (5 level)

Vref = 220 V Vcarrier = 91,67 Vpp Fref = 50 Hz Fcarrier = 650 Hz

- Gelombang Vref dan Vcarrier

(13)

- Gelombang Vt

- Gelombang It

Indeks modulasi 1,4 Full Bridge

Vref = 220 V Vcarrier = 157,14 V Fref = 50 Hz Fcarrier = 500 Hz

(14)

- Gelombang Vref dan Vcarrier

- Gelombang Vt

(15)

- Gelombang It

Cascaded Multicells (5 level)

Vref = 220 V Vcarrier = 78,57 Vpp Fref = 50 Hz Fcarrier = 500 Hz

- Gelombang Vref dan Vcarrier

(16)

- Gelombang Vt

- Gelombang It

(17)

Kesimpulan

Vref Fref

Vcarrier Fcarrier THD It Vcarrier Fcarrier THD It

Indeks Modulasi Full Bridge Cascaded Multicells

220 V 50 Hz 366,67 V 500 Hz 6,90% 183,34 Vpp 500 Hz 5,45% 0,6 220 V 50 Hz 275 V 450 Hz 3,81% 137,5 Vpp 450 Hz 3,47% 0,8 220 V 50 Hz 220 V 251 Hz 4,69% 110 Vpp 251 Hz 4,53% 1 220 V 50 Hz 183,33 V 650 Hz 2,80% 91.67 Vpp 650 Hz 2,78% 1,2 220 V 50 Hz 157,14 V 500 Hz 4,67% 78,57 Vpp 500 Hz 4,36% 1,4

• Rangkaian cascaded multicells (5 level) lebih baik daripada full bridge. Dibuktikan dengan frekuensi penyaklaran yang sama, rangkaian cascaded multicells menghasilkan harmonisa arus beban (THD It) lebih rendah dibanding rangkaian full bridge.

THD It cascaded multicells < THD It full bridge

Referensi

Dokumen terkait

Effect Analysis on EDFA Application on DCF at Different Scheme for Improving Performance of ROSMF Single Modulation System ,.. I hereby declare that all information in this document