• Tidak ada hasil yang ditemukan

appendix i procedure for setting the measurement system

N/A
N/A
Protected

Academic year: 2024

Membagikan "appendix i procedure for setting the measurement system"

Copied!
2
0
0

Teks penuh

(1)

46

APPENDIX I

PROCEDURE FOR SETTING THE MEASUREMENT SYSTEM

To setup the laser attenuation measurement system, all the components such as laser source, light intensity power meter, lens holders, plano-convex lenses and platforms must be prepared first. The batteries in the laser source and light intensity power meter are checked to ensure that the batteries can supply enough power. Each of the plano-convex lenses is inserted into a lens holder and it is tightened by using two locks on the sides of lens holder.

These lenses have 15cm focal length and 5cm diameter.

Next, the laser source and light intensity power meter are placed at the end of each platform. The locks under the laser source and light intensity power meter are inserted into the holes approximately 6cm away from the edge of the platforms. The bolts are used to tighten the locks but it is recommended not to over-tighten the locks to let both components have some space to move for the adjustment. Each of the plano-convex lenses which have been tightened in the lens holders is placed 15cm away from the laser source and light intensity power meter. The legs of lens holders are placed inside the holes and tightened by the bolts. It is also recommended to let the lens holder to have some space for the movement.

Then, all the switches on the laser source and light intensity power meter are turned on. A piece of white paper is put between the lens holders to see the expanded laser beam.

The paper is removed and let the laser beam hits the light intensity power meter. Adjustment is made to the position of light intensity power meter until the converged laser beam hits the surface of light dependent resistor (LDR). The voltage reading is obtained from the digital panel meter on the light intensity power meter.

By default, this light intensity power meter gives the maximum voltage of 5V when the laser beam is not directed to the LDR or the laser source is turned off and the minimum

(2)

47

voltage around 1.2V when the laser beam hits the LDR. If the plano-convex lens is changed to a different focal length such as 25cm, the procedure for setting this measurement system is still the same. However, both the plano-convex lenses which locked inside the lens holders are placed 25cm away from the laser source and light intensity power meter.

Referensi

Dokumen terkait

This paper discusses the measurement of oxidation kinetics of methyl oleate-methyl lau- rate blend system as a surrogate jatropha- coconut biodiesel system in the

211 The Measurement and Evaluation of Information System Success Based on Organizational Hierarchical Culture Reni Haerani 1, Titik Khawa Abdul Rahman 2, Lia Kamelia 3 1Department

Based on secondary data collected from the report of the State Bank and based on financial security measurement indicators of the banking system, namely four typical indicators were the

Behavioural Consequences of the Performance Measurement System PMS in a Decision-Facilitating Role – A Review managerial accounting information to alleviate organisational control

Elective surgery system strengthening: development, measurement, and validation of the surgical preparedness index across 1632 hospitals in 119 countries NIHR Global Health Unit on

An integrated measurement system of postural angle and EMG signals allows ergonomics practitioners and engineers to understand the interaction of work posture and muscle effort in MMH

Conclusion After conducting a study of the planned CEMS system consisting of an NH3 Analyzer, several conclusions were obtained as follows: The NH3 ammonia measurement system is an

However, in the proposed system, a more simplified method, scalar diffrac- tion theory, can be applied since the polarization direction of the incident beam is fixed and the analysis of