The effect of air velocity on the performance of the direct evaporative cooling system

ABSTRACT

This experimental study aimed to determine the effect of airflow velocity on the performance of a direct evaporative cooling system. Rectangular-shaped honeycomb cooling pads with a length of 34 cm, a width of 25 cm, and a thickness of 3.5 cm are used as cooling media. The main parameters of the study are low air velocity (2.3 ms−1), medium (3.2 ms−1), and high velocity (3.7 ms−1). The data collected include dry bulb temperature, wet bulb temperature, output air temperature, input and output air velocity, input and output humidity, and solar radiation. These data are used to determine saturation efficiency, cooling capacity, temperature decreases, and feasibility index. The experimental results are presented in the form of tables and graphs and analysed based on existing theories. The results showed that the evaporative cooling system could produce output temperatures up to 27.5°C with input 31.4°C at low airspeed, 27.97°C with input 31.47°C at medium speed, and 27.7°C with input 31.30°C at high air speed. It was concluded that a low airflow rate would add to the cooling efficiency, and the higher the airflow rate, the lower the cooling efficiency. The results showed that evaporative cooling is achievable with a feasibility index of 19.89 ≤ F*≤ 20.67. The results also affirmed that cooling capability is higher where the feasibility indexes are comparatively low.

Referensi

Dokumen terkait

The results of this study to obtain the expected performance related (temperature, humidity and efficiency) for three different materials used as a medium in the cooling system

Among the scope in this report is running of experimental work using various air velocity as the operating parameter as well as the determination of the gasifier

The passive evaporative cooling techniques is used of natural evaporation water via out roof surface can be cooled by passive technique like let the water flow at the surface of the

state where the temperature ranges from 390C to 420Cin summer season with relative humidity of 22% to 29%.The cooling capacities have been observed as2.35kJ/s with cooling effectiveness

Performance of the direct evaporative cooler DEC operating in a hot and humid region of Sabah Malaysia ABSTRACT In the last decade, energy consumption for air conditioning

Based on the research of literature [27,28], this paper takes the wet cooling tower of a 1000 MW unit as the research object, the effects of the number, power, and installation layouts

Nomenclature Abbreviations AC Air conditioning CDD Cooling degree days CDH Cooling degree hours COP Coefficient of performance DGH Dehumidifying gram hours IEC Indirect evaporative

Therefore, this study aimed to examine the effect of varying cooling fluids on heat treatment of S45C carbon steel, specifically its hardness and microstructure changes.. The