(1)

FHC FHC

4" Ø BI PIPE 4" Ø BI PIPE 4" Ø BI PIPE 4" Ø BI PIPE 4" Ø BI PIPE

SP

SP SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

FHC FHC

4" Ø BI PIPE 4" Ø BI PIPE 4" Ø BI PIPE 4" Ø BI PIPE 4" Ø BI PIPE

SP

SP SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP RISER

RISER

1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE

1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE 1" Ø BI PIPE1" Ø BI PIPE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

A

B

C

D

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

A

B

C

D

SPRINKLER LAYOUT

LEGEND

BATAAN PENINSULA STATE UNIVERSITY

TECHNICAL WORKING GROUP FOR INFRASTRUCTURE

(DINALUPIHAN CAMPUS) DINALUPIHAN, BATAAN

UNIVERSITY PRESIDENT

DR. GREGORIO J. RODIS

VICE PRESIDENT ADMIN. & FINANCE

DR. EDMUNDO C. TUNGOL

APPROVED BY:

RECOMMENDED BY:

REVISION

NO.

2

DESCRIPTION DATE

SHEET CONTENT:

LOCATION:

AR. ROXETTE S. UMEREZ

PREPARED BY:

REVIEWED BY:

PROJECT TITLE:

DIRECTOR OF PPES

ENGR. ALFREDO D. VALENTOS

NOTED BY:

SHEET NUMBER:

BATAAN PENINSULA STATE UNIVERSITY

REPAIR & REHABILITATION OF ACADEMIC BLDG. II AT DINA-

LUPIHAN CAMPUS

G:\tblock\logo-bpsu.png

CAMPUS DIRECTOR

MR. BILLY ALIPIO

1

FHC

DESCRIPTION GATE VALVE

CHECK VALVE

4"Ø B.I. PIPE

1"Ø B.I. PIPE

FIRE HOSE CABINET

STUB OUT

FIRE EXTINGUISHER PENDENT TYPE SPRINKLER

SIAMESE TWIN

RISER

LEGEND DESCRIPTION

SP

4"Ø B.I. PIPE

1"Ø B.I. PIPE

AFSS-DC-02

THIRD FLOOR SPRINKLER LAYOUT FOURTH FLOOR

SPRINKLER LAYOUT