SPRINKLER LAYOUT+FDAS

N/A
N/A
Protected

Academic year: 2023

Membagikan "SPRINKLER LAYOUT+FDAS"

Copied!
1
0
0

Teks penuh

(1)

STAGE

FLAG POLE FLAG POLE

RAMP UP

LANDSCAPE LANDSCAPE

LANDSCAPE LANDSCAPE

SEPTIC VAULT

VOLLEYBALL COURT

ADDITIONAL PERIMETER FENCE

ADDITIONAL PERIMETER FENCE

LAMP POST

LAMP POST

LAMP POST

LAMP POST

LAMP POST

LAMP POST

LAMP POST

LAMP POST BOLLARD LIGHT

BOLLARD LIGHT

BOLLARD LIGHT

BOLLARD LIGHT

BOLLARD LIGHT

BOLLARD LIGHT SD FF-5

SD FF-6 SD FF-6 SD FF-6

600x600mm CONCRETE PANEL

CISTERN TANK & PUMP HOUSE

BUILDING LINE

BATAAN PENINSULA STATE UNIVERSITY

DINALUPIHAN MARKET BATAAN PENINSULA

MEDICAL CENTER

FIRE PROTECTION NOTES

1. ALL FIRE PROTECTION WORKS SHOWN HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF PHILIPPINE MECHANICAL CODE, PHILIPPINE FIRE CODE AND THE RULES AND REGULATIONS OF THE LOCAL BUILDING OFFICIAL.

2. SPRINKLER PIPING SYSTEM SHALL BE BLACK STEEL, ASTM A53 GRADE A OR B WITH MALLEABLE IRON THREADED FITTING FOR 2 12 INCH SMALLER, WELDED / FLANGED CONNECTIONS CLASS 150.

3. SPRINKLER SYSTEM SHALL BE HYDROSTATICALLY TESTED AT 100 PSI FOR 2 HOURS WITNESSED BY REPRESENTATIVES OF THE OWNER AND BUILDING OFFICIAL.

4. SPRINKLER SYSTEM SHALL BE PROVIDED WITH ADEQUATE HANGERS / SUPPORTS.

5. CLEAN, TREAT, PRIME PIPING SYSTEM AND SUPPORTS BEFORE APPLYING ONE COAT OF CHROMATE PRIMER AND ONE TOP COAT WITH ENAMEL PAINT 6. CONTRACTOR SHALL PROVIDE ONE YEAR WARRANTY FOR THE FIRE PROTECTION WORKS AFTER COMISSIONING.

7. FIRE WATER LINE SHALL BE PROVIDED WITH ADEQUATE PIPE SUPPORT, HANGERS, BRACKETS AND SWAY BRACES

8. NEW SPRINKLER HEADS SHALL BE UPRIGHT TYPE, STANDARD 12 INCH, ORDINARY TEMPERATURE RATING, AND INSTALLED APPROXIMATELY 150 mm BELOW CEILING OR FLOOR SLAB

GENERAL NOTES 1.0

1. ALL MECHANICAL WORKS HEREIN INCLUDED SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE PHILIPPINES NATIONAL BUILDING CODE AND THE REGULATION OF SUBIC BAY FREEPORT ZONE.

2. REGISTER AND DIFFUSER DIMENSION SHOWN ON THE DRAWING ARE NECK SIZE

3. DUCT SIZES INDICATED ON THE DRAWING REFER TO DUCT INSIDE DIMENSION. FOR INTERNALLY LINED DUCTS, SIZE DUCT WORKS TO COMPENSATE FOR THE INTERNAL LINING 4. PROVIDE 150 mm CLEARANCE BETWEEN THE EQUIPMENT BASE AND THE EDGE OF ALL CONCRETE PADS. SUBMIT SHOP DRAWINGS OF CONCRETE PADS FOR APPROVAL 5. PROVIDE VIBRATION ISOLATORS AND FLEXIBLE CONNECTORS BETWEEN THE EQUIPMENT AND PIPES / DUCTWORKS TO PREVENT TRANSMISSION OF NOISE AND VIBRATION 6. ALL DIMENSIONS ARE IN MILLIMETER, UNLESS OTHERWISE INDICATED

7. BUILDERS WORK SHALL BE PROVIDED BY MAIN CONTRACTOR TO SUIT EQUIPMENTS REQUIREMENTS WHERE APPLICABLE AND AS INDICATED IN LAYOUT DRAWING 8. PROVIDE CEILING ACCESS TO EQUIPMENT DAMPER, VALVES AND OTHER DEVICES LOCATED ABOVE CEILING

9. ALL OPENING FOR DUCTS AND PIPES SHALL NOT IN ANYWAY PENETRATE STRUCTURAL RIB ON BEAMS UNLESS OTHERWISE AUTHORIZED 10. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR APPROVAL PRIOR TO CONSTRUCTION

11. THE SUBCONTRACTOR SHALL ENSURE THAT ALL THE OFFERED EQUIPMENT CAN BE POSITIONED

12. THE EXACT LOCATION AND LEVEL OF ALL WALL OR CEILING MOUNTED THERMOSTATS / SWITCHES SHALL THE SUBJECT TO ARCHITECT'S APPROVAL BEFORE INSTALLATION.

13. ALL AIR GRILLES / LOUVERS SHALL BE MADE OF G.I. OR APPROVED EQUAL UNLESS OTHERWISE SPECIFIED THE COLOR & SURFACE FINISHING OF THE GRILLES / LOUVERS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL BEFORE MATERIAL ORDERING UNLESS OTHERWISE SPECIFIED, COLOR FINISHED SHALL BE IN BAKED ENAMEL PAINT.

14. DURING THE PROCESS OF THE WORKS ALL OPEN ENDS OF PIPES CONDUITS, DUCTS ETC SHALL BE SUITABLY CAPPED TO PREVENT THE INGRESS OF FOREIGN MATTER

15. FOR PIPES SLEEVES AND DUCTS THROUGH THE BARRIER, THE GAP BETWEEN THE PIPES AND SLEEVES AND THE GAP BETWEEN THE DUCTS AND FIRE BARRIERS MUST BE FIRMLY SEALED WITH SOFT PACKING HAVING A PERIOD OF FIRE RESISTANCE EQUAL TO THE FIRE BARRIERS. DETAILS OF DUCTS AND PIPES THROUGH WALL AND FLOOR SHALL BE PROVIDED BY THE CONTRACTOR AND APPROVED BY THE ARCHITECT BEFORE INSTALLATION.

16. ALL DUCTED FANS SHALL BE INSTALLED WITH FLEXIBLE DUCT CONNECTORS

17. IN THE ABSENCE OF ANY OTHER REQUIREMENT NOT FOUND IN THE LOCAL CODE, THE MATERIALS CONSTRUCTION AND INSTALLATION OF THE DUCTWORKS SHALL BE COMPLY WITH THE REQUIREMENT OF SMACNA OR ASHRAE

18. ALL DOOR LOUVER SIZES REFER TO ARCHITECTURAL DOOR SCHEDULE

19. FLEXIBLE DUCT CONNECTION SHALL BE PROVIDED WHERE ALL DUCT WORK PASSES ACROSS BUILDING EXPANSION JOINT FLEXIBLE CONNECTION SHALL BE NON - COMBUSTIBLE

GENERAL NOTES 1.1

1. ALL OS & Y VALVES SHALL BE EQUIPPED WITH TAMPER SWITCH WIRED TO FIRE ALARM PANEL 2. DISTANCE BETWEEN THE SPRINKLER DETECTOR AND CEILING SHALL BE 305mm OR LESS

3. NOMINAL 6" (152.4mm) TRANSVERSE FLUE SPACE AT RACK UPRIGHTS SHALL BE MAINTAINED IN A SINGLE ROW, DOUBLE ROW, AND MULTIPLE ROW RACKS 4. THE CLEARANCE BETWEEN THE SPRINKLER AND THE TOP OF STORAGE SHALL BE 18" (457mm)

5. MAXIMUM STORAGE HEIGHT SHALL BE 3.7 M IN ALL STORAGE AREAS

SITE DEVELOPMENT PLAN VICINITY MAP

GENERAL NOTES

BATAAN PENINSULA STATE UNIVERSITY

TECHNICAL WORKING GROUP FOR INFRASTRUCTURE

(DINALUPIHAN CAMPUS) DINALUPIHAN, BATAAN

UNIVERSITY PRESIDENT

DR. GREGORIO J. RODIS

VICE PRESIDENT ADMIN. & FINANCE

DR. EDMUNDO C. TUNGOL

APPROVED BY:

RECOMMENDED BY:

REVISION

NO.

2

DESCRIPTION DATE

SHEET CONTENT:

LOCATION:

AR. ROXETTE S. UMEREZ

PREPARED BY:

REVIEWED BY:

PROJECT TITLE:

DIRECTOR OF PPES

ENGR. ALFREDO D. VALENTOS

NOTED BY:

SHEET NUMBER:

BATAAN PENINSULA STATE UNIVERSITY

REPAIR & REHABILITATION OF ACADEMIC BLDG. II AT DINA-

LUPIHAN CAMPUS

G:\tblock\logo-bpsu.png

CAMPUS DIRECTOR

MR. BILLY ALIPIO

1

TABLE OF CONTENT

AFSS-DC-00