DR. Walid Asaad, MBBS, MD, DABR,CAQ

Diagnostic &Interventional Radiology King Abdulaziz University Hospital

INTERVENTIONAL RADIOLOGY &

ANGIOGRAPHY

(2)

INTERVENTIONAL RADIOLOGY

A subspecialty which provides minimally invasive techniques with the help of imaging modalities to diagnose or treat a condition.

Minimally invasive

Local anesthesia

Early recovery

(3)

8 out of 10 procedures use skin incisions smaller than 5 mm.

9 out of 10 procedures use only local anaesthetic, sometimes with sedation.

Up to 8 out of 10 patients go home the same day

(4)

INTERVENTIONAL RADIOLOGY

Stent placement

Embolization

Thrombolysis

Balloon angioplasty

Atherectomy

Electrophysiology

(5)

Percutaneous biopsy

Abscess drainage

Percutaneous nephrostomy

Percutaneous Biliary drainage

Radiofrequency ablation

(6)

ANGIOGRAPHY

The radiologic examination of vessels after the introduction of a contrast medium.

(7)

HISTORY

The first angiogram was performed only months after Roentgen's discovery of X rays.

Which was when?

Two physicians injected mercury salts into an amputated hand and created an image of the arteries

(8)

Post mortem injection of mercury salts in Jan,1896.

(9)

Interventional radiologic procedures began in 1930s with angiography.

In early 1960s Mason Jones pioneered transbrachial selective coronary

angiography.

Later in 1960s transfemoral angiography was developed.

(10)

BASIC PRINCIPLES

Arterial access

In 1953 Seldinger described a method for catheterization of vessels.

A percutaneous technique for arterial and venous access.

Femoral artery is most commonly used.

(11)

SELDINGER TECHNIQUE

Seldinger needle.

18gauge single use,sterile needle.

2 parts-- a solid inner needle(stylet) & an outer thin wall needle for smooth passage.

a hub---good instrument balance

winged handle---good control.

(12)
(13)
(14)

Site cleaned, area draped, local anesthetic given.

The seldinger needle is introduced into the artery.

When pulsating blood returns, the stylet is removed.

(15)

A guide wire is inserted through the needle.

With guide wire in vessel, needle is removed.

Catheter is threaded onto the guide wire.

Under fluoro, the catheter is then advanced and the guide wire is removed.

(16)
(17)

GUIDEWIRES

Guide the catheter.

Allow safe introduction of catheter into the vessel.

Made of stainless steel.

Usually about 145cm long

An inner core wire that is tapered at the end to a soft flexible tip.

(18)

Covered by a coating—teflon, heparin and

recently hydrophilic polymers(glide wires) are used.

Coating reduces friction, gives strength to GW.

Tips at the end of GW

Straight

J- tipped—prevents subintimal dissection of artery.

(19)
(20)
(21)
(22)

CATHETERS

Many shapes and sizes.

diameter is given in French(Fr)—

3Fr=1mm.

Straight- end hole only—smaller vessels/minimal contrast.

Pigtail- circular tip with multiple side holes —larger vessels/ more contrast.

(23)

H1 or Head hunter tip– used for femoral approach to brachiocephalic vessels.

Simmons catheter is highly curved --- for

sharply angled vessels--cerebral and visceral angiography.

C2 or Cobra catheter has angled tip joined to a gentle curve—celiac, renal & mesenteric

arteries.

(24)
(25)

Judkins catheters

Right(lesser curve) & left(greater curve) for right & left coronary arteries.

Amplatz catheters

Right & left coronary arteries

(26)
(27)
(28)

Contrast Media

Initially ionic iodine compounds were used.

Now non ionic contrast media in practice—

low adverse reactions and low physiologic problems.

(29)

INDICATIONS

Diagnosis & presence of ischemic heart disease.

After revascularization procedures

Congenital heart lesions & anomalies of great vessels.

Valve disease, myocardial disease &

ventricular function.

(30)

Atheroma

Aneurysms

Arteriovenous malformations

Arterial ischemia

Trauma

(31)

Patient preparation

Explain procedure & risk to the patient.

History & physical examination.

Lab tests.

Consent

Pre procedure I/V fluids.

Medication to relieve anxiety.

(32)

Monitoring during and after procedure

ECG, Automatic BP measurement & pulse oximetry.

Life saving drugs and equipments.

Immobile for minimum 4hrs after.

Vital signs monitored.

Puncture site inspected.

(33)

Contra-indications

Contrast allergy

Impaired renal function

Blood- clotting disorders

Anti coagulant medication

Unstable cardio pulmonary/ neurological status

(34)

Risks

Bleeding at puncture site

Thrombus formation

Embolus formation –plaque dislodged from vessel wall by catheter

Dissection of vessel

Puncture site infection ( contaminated sterile field)

Contrast reaction

(35)

INTERVENTIONAL RADIOLOGY SUITE

Specifically designed to accommodate the quantity of equipment needed & the large number of people

involved in the procedure.

(36)

Interventional radiology suite

Procedure Room

Room size- 400- 600 square feet

Easily cleaned

(floors, wall, etc.)

Outlets needed for O2, suction.

At least three

means of access.

Control Room

100-150 square feet

Easy access and communication to procedure room

Operating console with Computers, monitors .

(37)

EQUIPMENTS

The X-ray apparatus for interventional

radiology is more massive,flexible,expensive

& advanced.

More heat load and serial images.

(38)
(39)

X RAY TUBE

Two ceiling track-mounted X-ray tubes

alongwith an image intensified fluoroscope mounted on C or an L arm.

A large diameter massive anode disc(15cm diameter, 5cm thick) to accommodate heat load.

Cathodes designed for magnification &

serial radiography.

(40)

A large focal spot of 1mm for heat load.

A small focal spot( no more than 0.3mm) is necessary for spatial resolution of small

vessel magnification.

(41)

Power rating of 80kW—for rapid sequence serial radiography.

Anode heat capacity of 1 MHU—to accommodate heat load.

(42)

Generators

High frequency and high voltage generators

Three phase,12 pulse power.

(43)

Patient couch

Stationary couch with a floating,tilting or rotating table top.

Controls for couch positioning are located on side of table and also on a floor switch.

May also have a computer controlled stepping capability.

(44)

Image receptor

2 different types.

Cinefluorographic camera—now obsolete.

Nowadays Digital image receptors are used with a television camera pickup tube or a

charge-coupled device(CCD).

(45)

THANKS

Referensi

Dokumen terkait

• A software platform and operating system for mobile devices • Based on the Linux kernel • Developed by Google and later the Open Handset Alliance OHA • Allows writing managed code

IUPAC Nomenclature : Basic Principles 3 Name each side-chain alkyl group and designate its position on the parent carbon chain by a number for example, 2-methyl means a methyl group

Change in Mass in Control Volume = Mass Flux In – Mass Flux Out Conservation of Mass The conservation of mass requires that the change in mass stored in a control volume over time t

Ethics Dilemmas Ethics covers the following dilemmas: • how to live a good life • our rights and responsibilities • the language of right and wrong • moral decisions - what is good

©Brooks/Cole, 2003 Example 1 Example 1 Write an algorithm in pseudocode that finds the average of two numbers Solution Solution See Algorithm 8.1 on the next slide... AverageOfTwo

Identification of infectious agents Identification of infectious agents in the diagnostic laboratory in the diagnostic laboratory • Aids treatmentAids treatment • Helps antibiotic

• Plan Ahead – Set aside time to prepare questions • Identify Goals – Clearly identify the information that you want to obtain from the survey • Provide Instruction – Explain why

© 2005 Prentice-Hall 1-2 After reading this chapter, you should be able to: 1 Define Organizational Behavior OB 2 Identify the primary behavioral disciplines contributing to OB 3