vii

Yuda Nugraha, 2015

VARIASI PENAMBAHAN SILICA FUME TERHADAP BETON MUTU TINGGI SELF COMPACTING CONCRETE (SCC)

Universitas Pendidikan Indonesia | repository.upi.edu | perpustakaan.upi.edu

VARIASI PENAMBAHAN SILICA FUME TERHADAP BETON MUTU TINGGI SELF COMPACTING CONCRETE (SCC)

Yuda Nuraha 1002532

ABSTRAK

Self Compacting Concrete (SCC) merupakan beton yang dapat memadat

sendiri dengan slump yang tinggi, mampu mengisi ruang cetakan (formwork) tanpa mengalami segregasi dan mencapai kepadatan tertingginya. Untuk menghasilkan beton mutu tinggi SCC diperlukan bahan tambah (admixture)lain untuk melengkapi kinerja semen. Penambahan admixture tersebut berupa

superplasticizer dan silica fume.Superplasticizer yang digunakan dalam penelitian

ini yaitu tipe Nexco P1 dengan dosis tetap untuk semua variasi campuran yaitu sebesar 1.4%.Penelitian ini dilakukan untuk mengetahui pengaruh penambahan

silica fume terhadap kuat tekan beton SCC. Pengujian yang dilakukan yaitu

meliputi slump flow test, segregation resistance test, filling ability test dan uji kuat tekan pada usia beton 3, 7, 14 dan 28 hari. Terdapat lima variasi campuran silica fume yang ditambahkan yaitu 1.4%, 1.7%, 1.9%, 2.1% dan 2.3% dari berat semen. Penambahan silica fume berpengaruh pada peningkatan kuat tekan beton. Kuat tekan tertinggi didapat dari komposisi beton dengan campuran silica fume

sebanyak 1.9% dan hasil kuat tekan pada usia 28 hari mencapai 64.51 MPa. Sedangkan hasil kuat tekan terendah didapat dari komposisi beton dengan campuran silica fume sebanyak 2.3% dan hasil kuat tekan mencapai 60.36 MPa. Untuk melengkapi hasil penelitian, dapat dilakukan pengujian slump loss pada beton segar serta pengujian kuat geser dan lentur pada beton yang telah mengeras.

(2)

viii

Yuda Nugraha, 2015

VARIASI PENAMBAHAN SILICA FUME TERHADAP BETON MUTU TINGGI SELF COMPACTING CONCRETE (SCC)

Universitas Pendidikan Indonesia | repository.upi.edu | perpustakaan.upi.edu

VARIETY OF SILICA FUME ADDITION ON HIGH STRENGTH SELF COMPACTING CONCRETE (SCC)

Yuda Nuraha 1002532

ABSTRACT

Self Compacting Concrete (SCC) is a concrete that can be solid by its own

with the high slump, it is capable of filling the mold (formwork) without having segregation and reaching its highest density. To produce the high strength concrete, SCC needs other supporting materials (admixture) to complete the performance of cement. The addition of admixture are superplasticizer and silica fume. Superplasticizer that is used in this research is type Nexco P1 with constant dose for all variant as many as 1.4%. This research is conducted to now the influence of the addition of silica fume on SCC compressive strength. The data are analysed by using slump flow test, segregation resistance test, filling ability test, and examining the strength of concrete tense of age 3, 7, 14, and 28 days. There are five variants of the mixture of silica fume addition, they are 1.4%, 1.7%, 1.9%, 2.1%, 2.3% of the cement weight. The addition of silica fume has influence on the increase of compressive strength. The highest strength of the test is obtained from concrete composition, with the mixture of silica fume as many as 1.9% and the compressive strength in age 28 reach 64.51 Mpa. While the result of the lowest compressive strength is obtained from the concrete composition with silica fume addition as many as 2.3% and reaches 60.36 Mpa. To complete the research result, slump loss test can be used on the fresh concrete and also shear strength and flexural strength test on the concrete that has been hard.

Referensi

Dokumen terkait

beton dengan parameter yang ditinjau adalah kuat tekan, kuat tarik, kuat lentur,. pengujian berat volume dan serapan air beton terhadap campuran beton

Penelitian ini dilakukan untuk mengetahui pengaruh penambahan serat sisal terhadap sifat mekanis mortar berupa kuat tekan, kuat belah ( splitting ), dan kuat

ϯ͘ Pengujian kuat lentur balok beton dengan konsentrasi cacahan plastik 0,70% diperoleh nilai kuat lentur rata-rata sebesar 4,21 MPa, nilai kuat lentur pada balok beton dengan

Diameter sebaran slump flow beton segar SCC dengan variasi kadar agregat alami batu bulat dan agregat daur ulang. Gambar kecepatan aliran hasil pengujian slump flow beton

Seberapa besar pengaruh perubahan komposisi campuran beton pada daerah tarik terhadap kuat lentur balok beton bertulang, apakah hasil pengujian kuat lentur balok beton bertulang

Pada saat pengujian kuat lentur balok beton normal dan beton bakteri selama 28 hari terjadi pola keretakan lentur pada balok. Pengujian pada balok beton

Ϯ͘ Pengujian kuat lentur balok beton dengan konsentrasi cacahan plastik 0,50% diperoleh nilai kuat lentur rata-rata sebesar 4,33 MPa, nilai kuat lentur pada balok beton dengan

Pada pengujian kuat lentur balok beton bertulang kayu kamper ini, metode yang digunakan yaitu metode pengujian kuat lentur beton dengan dua titik pembebanan, yaitu balok beton yang