• Tidak ada hasil yang ditemukan

LAMPIRAN A DATA MONITORING

N/A
N/A
Protected

Academic year: 2023

Membagikan "LAMPIRAN A DATA MONITORING"

Copied!
46
0
0

Teks penuh

(1)

A-1

Universitas Sultan Ageng Tirtayasa

LAMPIRAN A DATA MONITORING

Hari ke - 1

Tabel 1 Monitoring Ketinggian Air Hari ke-1 Tanggal Waktu Ketinggian air

(cm) Waktu Ketinggian air (cm)

13/06/2022

10:30 6624 13:30 8520

10:45 7152 13:45 8520

11:00 7152 14:00 8544

11:15 7152 14:15 8544

11:30 7152 14:30 8544

11:45 7344 14:45 8520

12:00 8712 15:00 8484

12:15 8616 15:15 8376

12:30 8616 15:30 8412

12:45 8616 15:45 8376

13:00 8616 16:00 8352

13:15 8616

Gambar 1 Grafik Monitoring Ketinggian Air Hari ke-1

(2)

A-2

Universitas Sultan Ageng Tirtayasa

Tabel 2 Monitoring Volume Air Hari ke-1 Tanggal Waktu Volume air

(liter) Waktu Volume air (liter)

13/06/2022

10:30 6624 13:30 8520

10:45 7152 13:45 8520

11:00 7152 14:00 8544

11:15 7152 14:15 8544

11:30 7152 14:30 8544

11:45 7344 14:45 8520

12:00 8712 15:00 8484

12:15 8616 15:15 8376

12:30 8616 15:30 8412

12:45 8616 15:45 8376

13:00 8616 16:00 8352

13:15 8616

Gambar 2 Grafik Monitoring Volume Air Hari ke-1

(3)

A-3

Universitas Sultan Ageng Tirtayasa

Tabel 3 Monitoring Tekanan Air Hari ke-1 Tanggal Waktu Tekanan air

(bar) Waktu Tekanan air (bar)

13/06/2022

10:30:00 1,3 10:32:40 1,2

10:30:10 1,3 10:32:50 1,2

10:30:20 1,2 10:33:00 1,1

10:30:30 1,2 10:33:10 1,1

10:30:40 1,1 10:33:20 0

10:30:50 0,1 10:33:30 0,5

10:31:00 1 10:33:40 2

10:31:10 2 10:33:50 1,8

10:31:20 1,8 10:34:00 1,7

10:31:30 1,8 10:34:10 1,6

10:31:40 1,7 10:34:20 1,5

10:31:50 1,6 10:34:30 1,5

10:32:00 1,5 10:34:40 1,3

10:32:10 1,5 10:34:50 1,3

10:32:20 1,3 10:35:00 1,2

10:32:30 1,3

Gambar 3 Grafik Monitoring Tekanan Air Hari ke-1

(4)

A-4

Universitas Sultan Ageng Tirtayasa

Hari ke – 2

Tabel 4 Monitoring Ketinggian Air Hari ke-2 Tanggal Waktu Ketinggian air

(cm) Waktu Ketinggian air (cm)

14/06/2022

10:30 66,3 13:30 65,5

10:45 66,6 13:45 65,2

11:00 65,7 14:00 64,8

11:15 65,5 14:15 64,8

11:30 65,7 14:30 64,3

11:45 65,7 14:45 64,8

12:00 66 15:00 64,6

13:00 65,5 15:15 64,3

13:15 64,8 15:30 64,8

Gambar 4 Grafik Monitoring Ketinggian Air Hari ke-2

(5)

A-5

Universitas Sultan Ageng Tirtayasa

Tabel 5 Monitoring Volume Air Hari ke-2 Tanggal Waktu Volume air

(liter) Waktu Volume air (liter)

14/06/2022

10:30 7920 13:30 7860

10:45 7992 13:45 7824

11:00 7884 14:00 7776

11:15 7884 14:15 7752

11:30 7884 14:30 7776

11:45 7884 14:45 7752

12:00 7920 15:00 7752

13:00 7860 15:15 7752

13:15 7824 15:30 7752

Gambar 5 Grafik Monitoring Ketinggian Air Hari ke-2

(6)

A-6

Universitas Sultan Ageng Tirtayasa

Tabel 6 Monitoring Tekanan Air Hari ke-2 Tanggal Waktu Tekanan air

(bar) Waktu Tekanan air (bar)

14/06/2022

10:35:00 1,1 10:37:40 1,2

10:35:10 1,1 10:37:50 1,1

10:35:20 1 10:38:00 1,1

10:35:30 0,8 10:38:10 1

10:35:40 1 10:38:20 0,8

10:35:50 1,7 10:38:30 0,8

10:36:00 2 10:38:40 1,7

10:36:10 1,8 10:38:50 2

10:36:20 1,7 10:39:00 1,8

10:36:30 1,7 10:39:10 1,7

10:36:40 1,6 10:39:20 1,6

10:36:50 1,5 10:39:30 1,6

10:37:00 1,5 10:39:40 1,5

10:37:10 1,3 10:39:50 1,5

10:37:20 1,3 10:40:00 1,3

10:37:30 1,2

Gambar 6 Grafik Monitoring Ketinggian Air Hari ke-2

(7)

B-1

Universitas Sultan Ageng Tirtayasa

LAMPIRAN B PERHITUNGAN

Persamaan awal :

𝑦 = 𝑚𝑥 + 𝑏 Persamaan untuk mencari keluaran arus :

𝐼 =

𝐼ℎ𝑖𝑔ℎ−𝐼𝑙𝑜𝑤

𝑃𝑣ℎ𝑖𝑔ℎ−𝑃𝑣𝑙𝑜𝑤

(𝑃𝑣 − 𝑃𝑣

𝑙𝑜𝑤

) + 𝐼

𝑙𝑜𝑤

Keterangan :

I = arus (mA)

𝐼

ℎ𝑖𝑔ℎ

= arus maksimal (mA) 𝐼

𝑙𝑜𝑤

= arus minimal (mA)

𝑃𝑣

ℎ𝑖𝑔ℎ

= batas atas pengukuran (cm) untuk ketinggian dan (bar) untuk tekanan 𝑃𝑣

𝑙𝑜𝑤

= batas bawah pengukuran (cm) untuk ketinggian dan (bar) untuk tekanan 𝑃𝑣 = hasil yang terukur

Perhitungan Arus Level Transmitter Ketinggian

air (cm) Perhitungan Arus (mA)

0 cm

𝐼 = 𝑃𝑣𝐼ℎ𝑖𝑔ℎ−𝐼𝑙𝑜𝑤

ℎ𝑖𝑔ℎ−𝑃𝑣𝑙𝑜𝑤(𝑃𝑣 − 𝑃𝑣𝑙𝑜𝑤) + 𝐼𝑙𝑜𝑤 = 20−4

100−0(0 − 0) + 4 = 4 𝑚𝐴

5.7 cm

𝐼 = 20−4

100−0(5.7 − 0) + 4 = 4.91 𝑚𝐴

10.6 cm

𝐼 = 20 − 4

100 − 0(10.6 − 0) + 4 = 5.70 𝑚𝐴

15 cm 𝐼 =

100−020−4

(15 − 0) + 4 = 6.40 𝑚𝐴 20.2 cm 𝐼 =

20−4

100−0

(20.2 − 0) + 4 = 7.20 𝑚𝐴 25.5 cm 𝐼 =

20−4

100−0

(25.5 − 0) + 4 = 8.08 𝑚𝐴 30.2 cm 𝐼 = 20 − 4

100 − 0 (30.2 − 0)+= 8.83 𝑚𝐴 35.5 cm 𝐼 = 20 − 4

100 − 0 (35.5 − 0) + 4 = 9.68 𝑚𝐴 40.6 cm 𝐼 = 20 − 4

100 − 0 (40.6 − 0) + 4 = 10.50 𝑚𝐴 45.6 cm 𝐼 =

20−4

100−0

(45.6 − 0) + 4 = 11.30 𝑚𝐴 50.3 cm 𝐼 =

100−020−4

(50.3 − 0) + 4 = 12.05 𝑚𝐴 55.2 cm 𝐼 =

100−020−4

(55.2 − 0) + 4 = 12.83 𝑚𝐴 60.3 cm 𝐼 =

20−4

100−0

(60.3 − 0) + 4 = 13.65 𝑚𝐴 65.2 cm 𝐼 =

20−4

100−0

(65.2 − 0) + 4 = 14.43 𝑚𝐴 70.1 cm 𝐼 =

20−4

100−0

(70.1 − 0) + 4 = 15.22 𝑚𝐴

(8)

B-2

Universitas Sultan Ageng Tirtayasa

Perhitungan Arus Level Transmitter Ketinggian

air (cm) Perhitungan Arus (mA)

73 cm 𝐼 = 20 − 4

100 − 0 (73 − 0) + 4 = 15.68 𝑚𝐴

Perhitungan Arus PressureTransmitter Tekanan

air (cm) Perhitungan Arus (mA)

0 bar 𝐼 =

𝑃𝑣𝐼ℎ𝑖𝑔ℎ−𝐼𝑙𝑜𝑤

ℎ𝑖𝑔ℎ−𝑃𝑣𝑙𝑜𝑤

(𝑃𝑣 − 𝑃𝑣

𝑙𝑜𝑤

) + 𝐼

𝑙𝑜𝑤

=

100−020−4

(0 − 0) + 4 = 4 𝑚𝐴 0.2 bar 𝐼 = 20 − 4

10 − 0 (0.1 − 0) + 4 = 4,16 𝑚𝐴 0.5 bar 𝐼 = 20 − 4

10 − 0 (0,5 − 0) + 4 = 4,80 𝑚𝐴 0.7 bar 𝐼 = 20 − 4

10 − 0 (0.7 − 0) + 4 = 5,12 𝑚𝐴 1 bar 𝐼 = 20 − 4

10 − 0 (1 − 0) + 4 = 5,6 𝑚𝐴 1,2 bar 𝐼 = 20 − 4

10 − 0 (0.2 − 0) + 4 = 5,92 𝑚𝐴 1,5 bar 𝐼 = 20 − 4

10 − 0 (1,5 − 0) + 4 = 6,40 𝑚𝐴 1,7 bar 𝐼 = 20 − 4

10 − 0 (1,7 − 0) + 4 = 6,72 𝑚𝐴 2 bar 𝐼 =

20−4 10−0

(2 − 0) + 4 = 7.2 𝑚𝐴

1. Level transmitter Persentase kesalahan

Kesalahan (%) = | Nilai Eksperimen − Nilai Teoritis

Nilai terotis | x 100%

= |

159,74−160,46

160,46

| x 100% = 0,4%

Scaling Analog Masukan Level

Gain B112

Analog masukan, X = 779, A=1000, B=1023, C= -200 Y = ( A

B ) X + C Y = ( 1000

1023 ) 779 − 200

(9)

B-3

Universitas Sultan Ageng Tirtayasa

Y = 561 Gain B114

Analog Masukan, X = 561, A=1000, B=880, C=0 Y = ( A

B ) X + C Y = ( 100

80 ) 561 + 0 Y = 701 2. Pressure transmitter

Persentase Kesalahan

Kesalahan (%) = | Nilai Eksperimen − Nilai Teoritis

Nilai terotis | x 100%

= |

50,23−50,08

50,08

| x 100% = 0,2%

Scaling Analog Masukan Pressure

Gain B024

Analog masukan, X = 368, A=100, B=1023, C=-20 Y = ( A

B ) X + C Y = ( 100

1023 ) 369 − 20 Y = 16

Gain B024

Analog Masukan, X = 16, A=100, B=80, C=0 Y = ( A

B ) X + C Y = ( 100

80 ) 16 + 0

Y = 20

(10)

D-1

Universitas Sultan Ageng Tirtayasa

LAMPIRAN C PERALATAN PENELITIAN

Gambar 7 Plant Penelitian

Gambar 8 Level Transmitter

Tabel 7 Spesifikasi Level Transmitter No Nama Spesifikasi

1 Merek ZGCJ

2 No. Model CJ-YBT

3 Range 0-1 meter

4 Siganl keluaran 4-20 mA (2 wire) 5 Power supply 24 VOLT DC 6 accuracy ± 0,5% FS 7 Protection IP68

Tangki

Motor Panel kendali

Pressure trasnmitter Pressure

switch

(11)

D-2

Universitas Sultan Ageng Tirtayasa

Gambar 9 Pressure Transmitter

Tabel 8 Spesifikasi Pressure Transmitter No Nama Spesifikasi

1 Merek Autonics

2 No. Model TPS20-G16P2

3 Range 0-10 kgf/cm

2

4 Signal keluaran 4-20 mA (2 wire) 5 Power supply 24 VOLT DC 6 accuracy ± 0,3% FS

Gambar 10 Pressure Switch

Gambar 11 Pressure Gauge

(12)

D-1

Universitas Sultan Ageng Tirtayasa

LAMPIRAN D LISTING PROGRAM HMI

1. Listing tombol log in Touch Pushbutton > Action

DIM LOGONRESULT AS DISCRETE;

LOGONRESULT = PostLogonDialog();

$OperatorEntered = "None";

$PasswordEntered = "";

2. Listing script application Listing volume tank

Volume_Tank = ((6*2*Level/100)*1000);

Listing data float pressure transmitter (scaling)

Pressure_Bar = (Nilai_Pressure*1/10

);

Listing data float level transmitter (scaling)

Level = (Nilai_Level*1/10);

3. Listing Window Log on

IF $Operator == "Administrator " OR $Operator == "Engineer" OR

$Operator == "Staff" OR $Operator == "Operator" THEN Show "Monitoring";

ELSE

Hide "Monitoring";

ENDIF;

4. Listing Tombol Change Password Touch Pushbutton > Action

IF Log_Out == Logoff() THEN Show "Menu Log On";

Hide "Monitoring";

ENDIF;

5. Listing Tombol Log out Touch Pushbutton > Action

IF Log_Out == Logoff() THEN Show "Menu Log On";

(13)

D-2

Universitas Sultan Ageng Tirtayasa Hide "Monitoring";

ENDIF;

6. Listing Tombol Connect Touch Pushbutton > Action

ResultCode = SQLConnect(ConnectionID, "DSN=DataSkripsi");

7. Listing Tombol Disconnect Touch Pushbutton > Action

ConnectionID = 0;

ResultCode = 0;

ResultCode = SQLDisconnect(ConnectionID);

8. Listing Script Data Change Database

ResultCode = SQLSelect(ConnectionID, "DataSkripsi", "dataskripsi",

"","");

ResultCode = SQLInsert(ConnectionID, "DataSkripsi", "dataskripsi");

Nomor = Nomor+1;

Tanggal =$DateString;

Waktu = $TimeString;

ErrorMsg = SQLErrorMsg(ResultCode);

(14)

E-1

Universitas Sultan Ageng Tirtayasa

LAMPIRAN E PROGRAM PLC

Gambar 12 Setting-an pada Zelio Smart Relay

(15)

Program information

Author : Author Project name : indobara Version : 0.0 Module : SR3B261BD

Cycle time in the module : 11 x 2 ms WATCHDOG actio n : Inactive

Type of Hardware Input Filtering : Slow (3ms) Locking of module front panel

Date format : dd/mm/yyyy

Daylight Saving Time change activated Zone : Europe

Change to Daylight Saving Time : March, Last Sunday Return to winter time : October, Last Sunday

XT1 : SR3MBU01

Number of wires and format : 2 wires, RTU Speed in bauds : 19200

Parity : Even

Modbus slave address : 1

XT2 : SR3XT43BD Type of inputs : Input IP : 0-20 mA Input IQ : 0-20 mA Type of outputs : Output OF : Analog Output OG : Analog Analog output ramp : Output OF : 0 s Output OG : 0 s

Frequency of PWM outputs : Not Applicable

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 1 / 32

(16)

I1

I2

I3

I4

I5

I6

I7

I8

I9

IA

IB

IC

ID

IE

IF

IG

Q1

Q2

Q3

Q4

Q5

Q6

Q7

Q8

Q9

QA

IH XT2

IJ XT2

QB XT2

QC XT2 B000

Relay 1 B001

Auto Pump 1 B002

Auto Pump 2 B003

Manual Pump 1 B004

Manual Pump 2 B005

Start Pump 1 B006

Start Pump 2 B007

Stop Pump 1 B008

Stop Pump 2 B009

Relay 2 B010

Emergency Stop B011

B012

B013

Pressure Transmitter

B014

Relay 3 B015

Relay 4 B016

B017

B018

VFD 1 B019

VFD 2 B020

B021

B022

B023

B024 B025

B026 B027

B028 B029 B030

B031

B032

B033

B034

B035

B036

B037

B038

B039

B040 B041

B042

B043

B044 B045

B046

B047

B048

B049

B050

B051

B052

B053

B054

B055 B056

B057 B058

B059

B060 B061

B062

B063

B064

B065

B066

B067 B068

B069

B070

B071

B072 B073

B074

B075

B076

B077

B078

M01

J1 XT1

J2 XT1

J3 XT1

J4 XT1

O1 XT1

O2 XT1

O3 XT1

O4 XT1 B081

B085

B086

B087

B088

B089

B090

B091

B096

B100

B101 B102

B103 B104

B105

B106

B107

B108

B111 B112

B113

Level Transnmitter

B114

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 2 / 32

Program diagram

(17)

I1

I2

I3

I4

I5

I6

I7

I8

I9

IA

IB

IC

ID

IE

IF

IG

Q1

Q2

Q3

Q4

Q5

Q6

Q7

Q8

Q9

QA

IH XT2

IJ XT2

QB XT2

QC XT2 B000

Relay 1 B001

Auto Pump 1 B002

Auto Pump 2 B003

Manual Pump 1 B004

Manual Pump 2 B005

Start Pump 1 B006

Start Pump 2 B007

Stop Pump 1 B008

Stop Pump 2 B009

Relay 2 B010

Emergency Stop B011

B012

B013

Pressure Transmitter

B014

Relay 3 B015

Relay 4 B016

B017

B018

VFD 1 B019

VFD 2 B020

B021

B022

B023

B024 B025

B026 B027

B028 B029 B030

B031

B032

B033

B034

B035

B036

B037

B038

B039

B040 B041

B042

B043

B044 B045

B046

B047

B048

B049

B050

B051

B052

B053

B054

B055 B056

B057 B058

B059

B060 B061

B062

B063

B064

B065

B066

B067 B068

B069

B070

B071

B072 B073

B074

B075

B076

B077

B078

M01

J1 XT1

J2 XT1

J3 XT1

J4 XT1

O1 XT1

O2 XT1

O3 XT1

O4 XT1 B081

B085

B086

B087

B088

B089

B090

B091

B096

B100

B101 B102

B103 B104

B105

B106

B107

B108

B111 B112

B113

Level Transnmitter

B114

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 3 / 32

(18)

I1

I2

I3

I4

I5

I6

I7

I8

I9

IA

IB

IC

ID

IE

IF

IG

Q1

Q2

Q3

Q4

Q5

Q6

Q7

Q8

Q9

QA

IH XT2

IJ XT2

QB XT2

QC XT2 B000

Relay 1 B001

Auto Pump 1 B002

Auto Pump 2 B003

Manual Pump 1 B004

Manual Pump 2 B005

Start Pump 1 B006

Start Pump 2 B007

Stop Pump 1 B008

Stop Pump 2 B009

Relay 2 B010

Emergency Stop B011

B012

B013

Pressure Transmitter

B014

Relay 3 B015

Relay 4 B016

B017

B018

VFD 1 B019

VFD 2 B020

B021

B022

B023

B024 B025

B026 B027

B028 B029 B030

B031

B032

B033

B034

B035

B036

B037

B038

B039

B040 B041

B042

B043

B044 B045

B046

B047

B048

B049

B050

B051

B052

B053

B054

B055 B056

B057 B058

B059

B060 B061

B062

B063

B064

B065

B066

B067 B068

B069

B070

B071

B072 B073

B074

B075

B076

B077

B078

M01

J1 XT1

J2 XT1

J3 XT1

J4 XT1

O1 XT1

O2 XT1

O3 XT1

O4 XT1 B081

B085

B086

B087

B088

B089

B090

B091

B096

B100

B101 B102

B103 B104

B105

B106

B107

B108

B111 B112

B113

Level Transnmitter

B114

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 4 / 32

(19)

M01B000

M01B001

M01B002

M01B003

M01B004 M01B005 M01B006

M01B007

M01B008

M01B009

M01B010

M01B011

M01B012

M01B013

M01B014 M01B015

M01B016

M01B017

M01B018

M01B019

M01B020

M01B021

M01B022

M01B023

M01B024

M01B025

M01B026

M01B027

M01B028

M01B029

M01B030

M01B031

M01B032 Value input

Input 1 Command Input 1 Input 2 Input 1 Input 1

Calculation output Current value Current value

Connect a link to this...

Connect a link to this...

Connect a link to this... Connect a link to this...

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 5 / 32

Diagram of the macro "ID001"

(20)

M01B000

M01B001

M01B002

M01B003

M01B004 M01B005 M01B006

M01B007

M01B008

M01B009

M01B010

M01B011

M01B012

M01B013

M01B014 M01B015

M01B016

M01B017

M01B018

M01B019

M01B020

M01B021

M01B022

M01B023

M01B024

M01B025

M01B026

M01B027

M01B028

M01B029

M01B030

M01B031

M01B032 Value input

Input 1 Command Input 1 Input 2 Input 1 Input 1

Calculation output Current value Current value

Connect a link to this...

Connect a link to this...

Connect a link to this... Connect a link to this...

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 6 / 32

(21)

M01B000

M01B001

M01B002

M01B003

M01B004 M01B005 M01B006

M01B007

M01B008

M01B009

M01B010

M01B011

M01B012

M01B013

M01B014 M01B015

M01B016

M01B017

M01B018

M01B019

M01B020

M01B021

M01B022

M01B023

M01B024

M01B025

M01B026

M01B027

M01B028

M01B029

M01B030

M01B031

M01B032 Value input

Input 1 Command Input 1 Input 2 Input 1 Input 1

Calculation output Current value Current value

Connect a link to this...

Connect a link to this...

Connect a link to this...

Connect a link to this...

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 7 / 32

(22)

Physical inputs

Input No Symbol Function Lock Parameters Comment

I1 B000 Discrete input --- No parameters Relay 1 I2 B001 Discrete input --- No parameters Auto Pump 1 I3 B002 Discrete input --- No parameters Auto Pump 2 I4 B003 Discrete input --- No parameters Manual Pump 1 I5 B004 Discrete input --- No parameters Manual Pump 2 I6 B005 Discrete input --- No parameters Start Pump 1 I7 B006 Discrete input --- No parameters Start Pump 2 I8 B007 Discrete input --- No parameters Stop Pump 1 I9 B008 Discrete input --- No parameters Stop Pump 2 IA B009 Discrete input --- No parameters Relay 2

IB B010 Discrete input --- No parameters Emergency Stop IC B011 Discrete input --- No parameters

ID B012 Discrete input --- No parameters IH

XT2 B013

Analog input expansion

10bits

--- No parameters Pressure Transmitter

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 8 / 32

(23)

Input No Symbol Function Lock Parameters Comment IJ

XT2 B113

Analog input expansion

10bits

--- No parameters Level Transnmitter

Module keys

No Symbol Function Comment

B020 Z1 button

B021 Z2 button

B022 Z3 button

B023 Z4 button

Physical outputs

Output No Symbol Function Comment

Q1 B014 Discrete output Relay 3 Q2 B015 Discrete output Relay 4 Q3 B016 Discrete output

Q4 B017 Discrete output QB

XT2 B018

Analog output expansion

10bits

VFD 1 QC

XT2 B019

Analog output expansion

10bits

VFD 2

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 9 / 32

(24)

Configurable functions

No Symbol Function Lock Latching Parameters Comment

B024 Gain = A/B x

value + C No --- Gain: y = (100/1023) x + -20 Range: 0 <= y <= 2000

B025 Gain = A/B x

value + C No --- Gain: y = (100/80) x + 0 Range: 0 <= y <= 100

B026 Numerical

constant No --- Value of the constant : 60

B027 Numerical

constant No --- Value of the constant : 45

B028 Timer A/C ext

setpoint --- No Unit : x 1 s

B029 Timer A/C ext

setpoint --- No Unit : x 1 s

B030 Numerical

constant No --- Value of the constant : 5 B031 RS switching --- --- Priority : RESET has priority

B032 Boolean

function --- --- See details below

B033 Boolean

function --- --- See details below

B034 Boolean

function --- --- See details below

B035 Gain = A/B x

value + C No --- Gain: y = (1023/50) x + 0 Range: 0 <= y <= 1023

B036 Boolean

function --- --- See details below B037 Preset up/down

counter No No Output ON when the preset value is reached : 50 Cycle Single

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 10 / 32

(25)

No Symbol Function Lock Latching Parameters Comment B038 RS switching --- --- Priority : RESET has priority

B039 Boolean

function --- --- See details below

B040 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

B041 Timer B/H No No On time : 0H 0M 1S

Function H

B042 Boolean

function --- --- See details below

B043 Boolean

function --- --- See details below

B046 RS switching --- --- Priority : RESET has priority

B047 Boolean

function --- --- See details below

B048 Boolean

function --- --- See details below

B049 Boolean

function --- --- See details below

B050 Boolean

function --- --- See details below

B051 Gain = A/B x

value + C No --- Gain: y = (1023/50) x + 0 Range: 0 <= y <= 1023

B052 Boolean

function --- --- See details below B053 Preset up/down

counter No No Output ON when the preset value is reached : 50 Cycle Single

B054 RS switching --- --- Priority : RESET has priority

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 11 / 32

(26)

No Symbol Function Lock Latching Parameters Comment

B055 Boolean

function --- --- See details below

B056 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

B057 Timer B/H No No On time : 0H 0M 1S

Function H

B059 Boolean

function --- --- See details below

B060 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

B061 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

B062 Boolean

function --- --- See details below

B063 Timer A/C ext

setpoint --- No Unit : x 1 s

B064 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

B065 Boolean

function --- --- See details below

B066 Boolean

function --- --- See details below

B067 Timer A/C ext

setpoint --- No Unit : x 1 s

B068 Boolean

function --- --- See details below

B069 Cyclic timing

ext setpoint --- No

Unit : x 1 s

Continuous flashing Function Li

B070 Boolean

function --- --- See details below

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 12 / 32

(27)

No Symbol Function Lock Latching Parameters Comment

B071 Boolean

function --- --- See details below

B072 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

B073 Boolean

function --- --- See details below

B074 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

B075 Boolean

function --- --- See details below

B076 Cyclic timing

ext setpoint --- No

Unit : x 0,1 s Continuous flashing Function Li

B077 Numerical

constant No --- Value of the constant : 3

B078 Cyclic timing

ext setpoint --- No

Unit : x 0,1 s Continuous flashing Function Li

B111 LCD display --- --- See details below

B112 Gain = A/B x

value + C No --- Gain: y = (1000/1023) x + -200 Range: 0 <= y <= 1000

B114 Gain = A/B x

value + C No --- Gain: y = (1000/800) x + 0 Range: 0 <= y <= 1000

M01B001 Boolean

function --- --- See details below M01B002 LCD display --- --- See details below M01B003 LCD display --- --- See details below

M01B005 CAM BLOCK No No See details below

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 13 / 32

(28)

No Symbol Function Lock Latching Parameters Comment M01B009 LCD display --- --- See details below

M01B010 LCD display --- --- See details below M01B011 Gain = A/B x

value + C No --- Gain: y = (60/1) x + 0

Range: -32768 <= y <= 32767 M01B012 Preset up/down

counter No Yes Output ON when the preset value is reached : 600 Cycle Single

M01B013 Boolean

function --- --- See details below

M01B015 Cyclic timing No No

On time : 2 x 0,1 s Off time : 2 x 0,1 s

Function Li - Continuous flashing

M01B018 Boolean

function --- --- See details below

M01B019 Boolean

function --- --- See details below

M01B020 Boolean

function --- --- See details below M01B021 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

M01B022 LCD display --- --- See details below M01B023 LCD display --- --- See details below M01B024 Preset up/down

counter No Yes Output ON when the preset value is reached : 60 Cycle Single

M01B025 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

M01B026 Boolean

function --- --- See details below

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 14 / 32

(29)

No Symbol Function Lock Latching Parameters Comment

M01B027 Boolean

function --- --- See details below M01B028 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

M01B029 Boolean

function --- --- See details below

M01B030 Boolean

function --- --- See details below M01B031 Preset up/down

counter No Yes Output ON when the preset value is reached : 60 Cycle Single

M01B032 Comparison of

2 values --- --- VALEUR 1 VALEUR 2

M01 ID001 --- --- See blocks M01BXX

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 15 / 32

(30)

BOOLEAN (Boolean function)

B032 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 0

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 1

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

B033 Boolean function Output ON if result is TRUE ENTREE 1 ENTREE 2 SORTIE

0 0 0

1 0 0

0 1 0

1 1 1

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 16 / 32

(31)

B034 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 1

0 1 0 1

1 1 0 0

0 0 1 1

1 0 1 0

0 1 1 0

1 1 1 0

B036 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 1

0 0 1 0

1 0 1 0

0 1 1 0

1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 17 / 32

(32)

B039 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 1

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 0

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 18 / 32

(33)

B042 Boolean function Output OFF if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 0

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 1

0 0 0 1 0

1 0 0 1 0

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

B043 Boolean function Output OFF if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 0

0 0 1 1

1 0 1 0

0 1 1 0

1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 19 / 32

(34)

B047 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 0

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 1

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

B048 Boolean function Output ON if result is TRUE ENTREE 1 ENTREE 2 SORTIE

0 0 0

1 0 0

0 1 0

1 1 1

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 20 / 32

(35)

B049 Boolean function Output OFF if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 0

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 1

0 0 0 1 0

1 0 0 1 0

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

B050 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 1

0 1 0 1

1 1 0 0

0 0 1 1

1 0 1 0

0 1 1 0

1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 21 / 32

(36)

B052 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 1

0 0 1 0

1 0 1 0

0 1 1 0

1 1 1 0

B055 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 1

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 0

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 22 / 32

(37)

B059 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 1

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 0

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 1

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 23 / 32

(38)

B062 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 1

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 0

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 24 / 32

(39)

B065 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 1

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 0

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 1

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 25 / 32

(40)

B066 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 1

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 0

0 1 0 1 0

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

B068 Boolean function Output ON if result is TRUE ENTREE 1 ENTREE 2 SORTIE

0 0 0

1 0 0

0 1 0

1 1 1

B070 Boolean function Output ON if result is TRUE ENTREE 1 ENTREE 2 SORTIE

0 0 0

1 0 0

0 1 0

1 1 1

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 26 / 32

(41)

B071 Boolean function Output ON if result is TRUE ENTREE 1 ENTREE 2 SORTIE

0 0 0

1 0 1

0 1 0

1 1 0

B073 Boolean function Output ON if result is TRUE ENTREE 1 ENTREE 2 SORTIE

0 0 0

1 0 0

0 1 0

1 1 1

B075 Boolean function Output ON if result is TRUE ENTREE 1 ENTREE 2 SORTIE

0 0 0

1 0 0

0 1 0

1 1 1

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 27 / 32

(42)

M01B001 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 0

0 0 1 1

1 0 1 1

0 1 1 1

1 1 1 0

M01B013 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 1

0 0 1 0

1 0 1 0

0 1 1 0

1 1 1 0

M01B018 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 0

0 0 1 1

1 0 1 1

0 1 1 1

1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 28 / 32

(43)

M01B019 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 1

0 0 1 0

1 0 1 0

0 1 1 0

1 1 1 0

M01B020 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 1

0 0 1 0

1 0 1 0

0 1 1 0

1 1 1 0

M01B026 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 1

0 0 1 0

1 0 1 0

0 1 1 0

1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 29 / 32

(44)

M01B027 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 0

0 0 1 1

1 0 1 1

0 1 1 1

1 1 1 0

M01B029 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 ENTREE 4 SORTIE

0 0 0 0 0

1 0 0 0 0

0 1 0 0 0

1 1 0 0 1

0 0 1 0 0

1 0 1 0 0

0 1 1 0 0

1 1 1 0 0

0 0 0 1 0

1 0 0 1 0

0 1 0 1 1

1 1 0 1 0

0 0 1 1 0

1 0 1 1 0

0 1 1 1 0

1 1 1 1 0

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 30 / 32

(45)

M01B030 Boolean function Output ON if result is TRUE

ENTREE 1 ENTREE 2 ENTREE 3 SORTIE

0 0 0 0

1 0 0 0

0 1 0 0

1 1 0 1

0 0 1 0

1 0 1 0

0 1 1 0

1 1 1 0

CAM BLOCK

M01B005 CAM BLOCK

Position S1 S2 S3 S4 S5 S6 S7 S8 1 1 0 0 0 0 0 0 0 2 0 1 0 0 0 0 0 0 3 0 0 1 0 0 0 0 0

DISPLAY (LCD display)

B111 LCD display

* * * * * . * Modification authorized in L4C7

M01B002 LCD display

P U M A H A S A R I J A N S M A R T P U M P

P r e s s : B A R

L e v e l : C M

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 31 / 32

(46)

M01B003 LCD display

* * * * * . * Modification authorized in L3C7

M01B009 LCD display

T i m e r : m i n

l o w : b a r

h i g h : b a r

ú M ü = > + -

M01B010 LCD display

* * * * * *

Modification authorized in L1C10

M01B022 LCD display

* * * * * . *

Modification authorized in L2C10

M01B023 LCD display

* * * * * . * Modification authorized in L3C10

Program Audit Recycling.zm2 - v0.0 indobara

Author 26/09/2022 32 / 32

Referensi

Dokumen terkait

1) Pesantren menerapkan aturan yang harus ditaati oleh setiap santri, apabila terjadi pelanggaran, santri akan mendapatkan hukuman dari riang sampai ke berat,

Peningkatan penyerapan cadangan karbon dapat dilakukan dengan (a) meningkatkan pertumbuhan biomasa hutan secara alami, (b) menambah cadangan kayu pada hutan yang

Majoriti pelajar Malaysia tidak teribat aktiviti sosial dalam komuniti kerana pertamanya kekangan masa iaitu (80%), kedua kurang minat (75%) dan ketiga aktiviti kurang

Peraturan Daerah suatu pembentukan di dalam peraturan perundang- undangan Penetapan tarif yang ada pada Peraturan Daerah Nomor 1 Tahun 2012 tentang Retribusi Jasa

Dari sisi pengeluaran, pertumbuhan ekonomi didorong oleh peningkatan komponen konsumsi rumah tangga, pengeluaran lembaga nirlaba nonprofit, konsumsi

Persetujuan Penyelesaian Pekerjaan (PPP) adalah persetujuan yang dikeluarkan oleh pejabat tertentu di SKK Migas terhadap Permohonan PPP yang diajukan oleh KKKS,

Berdasarkan hasil analisis karakteristik status pekerjaan terlihat bahwa responden mengalami kecemasan ringan dengan status tidak bekerja sedikit lebih tinggi di

jukung/perahu/kelotok.Saat ini fungsi rumah lanting tetap memiliki peranan sebagai tambatan perahu sekaligus usaha karamba. Secara fisik faktor yang mempengaruhi