LABORATORIUM PILOT PLANT
LABORATORIUM PILOT PLANT
SEMESTER GANJIL TAHUN AJARAN 2014/2015
SEMESTER GANJIL TAHUN AJARAN 2014/2015
MODUL
MODUL
:
: HUMIDIFIKASI
HUMIDIFIKASI DAN
DAN DEHUMIDIFIKAS
DEHUMIDIFIKASII
PEMBIMBI
PEMBIMBING
NG
:
: Ir.
Ir. Tri
Tri Haryadi
Haryadi
Oleh :
Oleh :
Kelompok
Kelompok
:
: III
III (tiga)
(tiga)
Nama
Nama
:
: 1.
1. FX.
FX. Angga
Angga Sugiyana
Sugiyana
NIM.12141
NIM.121411041
1041
2.
2. Fidihana
Fidihana Noviyanti
Noviyanti
NIM.12141
NIM.121411043
1043
3.
3. Hilman
Hilman F
F Ramadhan
Ramadhan
NIM.121411044
NIM.12141
1044
4. Hizba I. Naf’an
4. Hizba I. Naf’an
NIM.121411045
NIM.121411045
Kelas
Kelas
:
: 3B
3B
PROGRAM STUDI DIPLOMA III TEKNIK KIMIA
PROGRAM STUDI DIPLOMA III TEKNIK KIMIA
JURUSAN TEKNIK KIMIA
JURUSAN TEKNIK KIMIA
POLITEKNIK NEGERI BANDUNG
POLITEKNIK NEGERI BANDUNG
2014
2014
Praktikum
Praktikum
:
: 7
7 Oktober
Oktober 2014
2014
Penyerahan
Penyerahan :
: 14
14 Oktober
Oktober 2014
2014
(LAPORAN REVISI)
HUMIDIFIKASI DAN DEHUMIDIFIKASI
HUMIDIFIKASI DAN DEHUMIDIFIKASI
I.
I.
TUJUAN PRAKTIKUM
TUJUAN PRAKTIKUM
1.
1. Humidifikasi : menentukan harga kelembaban (Y), Entalphi (H),menentukan
Humidifikasi : menentukan harga kelembaban (Y), Entalphi (H),menentukan
jumlah
jumlah H
H
22O yang terserap, dan mengetahui pengaruh laju alir air terhadap
O yang terserap, dan mengetahui pengaruh laju alir air terhadap
jumlah H
jumlah H
22O yang terserap.
O yang terserap.
2.
2. Dehumidifikasi
Dehumidifikasi
:
:
menentukan
menentukan
harga
harga
kelembaban
kelembaban
(Y),
(Y),
Entalphi
Entalphi
(H),menentukan jumlah H
(H),menentukan jumlah H
22O yang menguap, dan mengetahui pengaruh beda
O yang menguap, dan mengetahui pengaruh beda
tekan laju alir udara terhadap jumlah H
tekan laju alir udara terhadap jumlah H
22O yang menguap.
O yang menguap.
II.
II.
LANDASAN TEORI
LANDASAN TEORI
Proses humidifikasi merupakan proses yang dapat menambah kadar air di
Proses humidifikasi merupakan proses yang dapat menambah kadar air di
dalam gas. Sebaliknya, untuk mengurangi uap air dalam aliran gas sering disebut
dalam gas. Sebaliknya, untuk mengurangi uap air dalam aliran gas sering disebut
proses
proses dehumidifikasi.
dehumidifikasi. Dalam
Dalam humidifikasi,
humidifikasi, kadar
kadar dapat
dapat ditngkatkan
ditngkatkan dengan
dengan
melewatkan aliran gas di atas cairan yang kemudian akan menguap ke dalam
melewatkan aliran gas di atas cairan yang kemudian akan menguap ke dalam
aliran gas.
aliran gas.
Perpindahan ke aliran utama berlangsung dengan cara difusi dan pada
Perpindahan ke aliran utama berlangsung dengan cara difusi dan pada
perbatasan
perbatasan (interface)
(interface) perpindahan
perpindahan panas
panas dan
dan massa
massa yang
yang berlangsung
berlangsung terus
terus
menerus, sedangkan dalam dehumidifikasi dilakukan pengembunan (kondensasi)
menerus, sedangkan dalam dehumidifikasi dilakukan pengembunan (kondensasi)
parsial dan uap yang terkondensasi dibuang.
parsial dan uap yang terkondensasi dibuang.
Penggunaan yang paling luas dari proses humidifikasi dan dehumidifikasi
Penggunaan yang paling luas dari proses humidifikasi dan dehumidifikasi
menyangkut system udara air. Contoh paling sederhana adalah pengeringan
menyangkut system udara air. Contoh paling sederhana adalah pengeringan
padatan
padatan basah
basah dengan
dengan pengurangan
pengurangan jumlah
jumlah kandungan
kandungan air
air sebagai
sebagai tujuan
tujuan utama
utama
dan dehumidifikasi aliran gas sebagai efek sampingan.
dan dehumidifikasi aliran gas sebagai efek sampingan.
Pemakaian AC dan pengeringan gas juga menggunakan proses humidifikasi
Pemakaian AC dan pengeringan gas juga menggunakan proses humidifikasi
dan dehumidifikasi. Sebagai contoh kandungan uap air harus dihilangkan dari gas
dan dehumidifikasi. Sebagai contoh kandungan uap air harus dihilangkan dari gas
klor basah, sehingga gas ini bias digunakan pada peralatan baja untuk
klor basah, sehingga gas ini bias digunakan pada peralatan baja untuk
menghindari korosi. Demikian juga pada proses pembuatan asam sulfat, gas yang
menghindari korosi. Demikian juga pada proses pembuatan asam sulfat, gas yang
digunakan dikeringkan sebelum masuk ke konventor bertekanan yaitu dengan
digunakan dikeringkan sebelum masuk ke konventor bertekanan yaitu dengan
jalan
jalan melewati
melewati pada
pada bahan
bahan yang
yang menyerap
menyerap air
air (dehydrating
(dehydrating agent)
agent) seperti
seperti silica
silica
gel, asam sulfat pekat, dan lain-lain.
gel, asam sulfat pekat, dan lain-lain.
Contoh proses humidifikasi adalah pada menara pendingin, air panas dialirkan
Contoh proses humidifikasi adalah pada menara pendingin, air panas dialirkan
berlawanan arah dengan media pendingin y
1.
Kelembaban yaitu massa uap yang dibawa oleh satu satuan massa gas bebas
uap, karena itu humidity hanya bergantung pada tekanan ba gian uap di dalam
campuran bila tekanan total tetap.
2.
Suhu bola basah yaitu suhu pada keadaan tunak dan tidak berkesetimbangan
yang dicapai bila suatu massa kecil dari zat cair dikontakkan dalam keadaan
adiatik di dalam arus gas yang kontinu.
3.
Kelembaban jenuh yaitu udara dalam uap air yang berkesetimbangan
dengan air pada suhu dan tekanan tertentu. Dalam campuran ini, tekanan
parsial uap air dalam campuran udara-air adalah sama tekanan uap air murni
pada temperatur terntentu.
4.
Kelembaban relatif yaitu ratio antara tekanan bagian dan tekanan uap zat
cair pada suhu gas. Besaran ini dinyatakan dalam persen (%) sehingga
kelembaban 100% berarti gas jenuh sedang kelembaban 0% berarti gas bebas
uap.
5.
Kalor lembab yaitu energi kalor yang diperlukan untuk menaikkan suhu satu
satuan massa beserta uap yang dikandungnya sebesar satu derajat satuan
suhu.
6.
Entalpi lembab adalah entalpi satu satuan massa gas ditambah uap yang
terkandung di dalamnya.
7.
Volume lembab adalah volume total stu satuan massa bebas uap beserta uap
yang dikandungnya pada tekanan 1 atm.
8.
Titik embun campuran udara-uap air adalah temperatur pada saat gas telah
jenuh oleh uap air.
Proses Humidifikasi dengan proses Dehumidifikasi mempunyai perbedaan
dalam arah alirannya. Semua itu tergantung dari cara mengatur valve yang ada.
Gas yang masuk mengalir pada pipa orifice mempunyai beda tekan tertentu.
Adapun perbedaan antara proses humidifikasi dengan dehumidifikasi sbb :
Proses humidifikasi, merupakan suatu proses yang dapat menambah kadar air
dalam gas. Dalam prosesnya ada dua cara yaitu dengan pemanasan dan tanpa
pemanasan. Arah aliran kedua proses tersebut berbeda tergantung bagaimana kita
dapat mengatur buka tutupnya valve. Pada proses ini, gas dikontakan dengan air
dan gas/udara menngalir ke atas dari bawah, dengan laju alir sirkulasi air tertentu.
Data yang diambil dari percobaan ini seperti, suhu air di dalam labu, suhu gas
masuk (T
dindan T
win), suhu gas keluar ( T
doutdan T
wout), dan beda tekanan di
dalam labu.
Proses Dehumidifikasi, yang merupakan proses pengurangan kadar air dalam
gas, sama dengan proses humidifikasi mempunyai dua cara proses, yaitu dengan
pemanasan dan tanpa pemanasan. Kesemuanya itu tergantuk cara mengatur valve
yang ada. Pada proses ini, gas dilewatkan pada sebuah kolom yang yang
didalamnya terdapat zat penyerap (
absorbent
) dan juga dengan memperbesar
tekanan. Data yang diambil pada percobaan ini seperti, suhu gas masuk (T
dindan
T
win), suhu gas keluar (T
doutdan T
wout), beda tekanan pada kolom (
P), dan suhu
keluaran kolom bagian (A, B, C, dan D) yang menempel pada kolom.
BAB III
METODOLOGI PERCOBAAN
3.1 Alat dan Bahan
Alat yang digunakan
Seperangkat alat humidifikasi dan dehumidifikasi
Kompressor
Pompa
Termometer pengukur temperature bola kering dan bola basah
Psychrometric Chart
Bahan yang digunakan :
Air
udara tekan
3.2 Langkah Kerja
3.2.1
Humidifikasi Tanpa Pemanasan
Memutar switch
utama pada panel
kontrol searah jarum
jam ke mode ON
memutar switch air
pressure pada posisi
ON
Mengatur
katup-katup: V2 & V4(Buka)
dan V2,V3V5,V6
(tutup)
Menekan tombol P2
(kompressor) pada
posisi ON
Mengatur katup
utama sehinggaa ada
perbedaan tekanan
orifice
Catat data pertama
pada laju alir air= 0,
t=10 menit
Menekan tombol P1
(
centrifugal pump
)
ON
Kemudian atur laju
alir
Ambil data tiap 2
menit, kemudian
variasikan laju alir
3.2.2 Dehumidifikasi Tanpa Pemanasan
Atur posisi katup.
Tutup V1, V3, dan V5
Atur posisi katup.
Buka V2, V4, dan V6
Tekan tombol P2
(Kompressor) ON
Atur katup utama (V9)
hingga dP orifice sesuai yang
telah ditentukan
Ambil data pertama
7
Laporan Humidifikasi & Dehumidifikasi
BAB IV
HASIL DAN PEMBAHASAN 4.1.1 Run 1
Q air = 40 L/h ∆P = 30 mbar
NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H
(gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 31 46.2 22 0.013 64.5 28 66 23 0.0157 68.3 0.0027 2 2 32 42.3 22 0.0126 64.5 28 66 23 0.0157 68.3 0.0031 3 4 32 42.3 22 0.0126 64.5 28 66 23 0.0157 68.3 0.0031 4 6 35 36.5 23 0.0129 68.3 28 72.3 24 0.0172 72.2 0.0043 5 8 35 32.5 22 0.0114 64.5 28 66 23 0.0157 68.3 0.0043 6 10 35 36.5 23 0.0129 68.3 28 72.3 24 0.0172 68.3 0.0043 7 12 36 29.7 22 0.011 64.5 28 72.3 24 0.0172 68.3 0.0062 8 14 36 29.7 22 0.011 64.5 27 78.4 24 0.0177 72.2 0.0067 9 16 36 29.7 22 0.011 64.5 27 78.4 24 0.0177 72.2 0.0067 10 18 37 27.1 22 0.0106 64.5 27 85.3 25 0.0193 76.3 0.0087 11 20 37 27.1 22 0.0106 64.5 27 85.3 25 0.0193 76.3 0.0087 Rata-rata ∆g 0.005345 4.1.2 Run 2 Q air = 50 L/h ∆P = 30 mbar NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H
(gout-gin) (oC) (%) (oC) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 35 36.5 23 0.0129 68.3 28 72.3 24 0.0172 72.2 0.0043 2 2 37 34.6 24 0.0136 72.2 28 72.3 24 0.0172 72.2 0.0036 3 4 34 39.8 23 0.0133 68.3 28 72.3 24 0.0172 72.2 0.0039 4 6 36 39.8 24 0.0133 68.3 29 66.7 24 0.0168 72.2 0.0035 5 8 36 39.8 24 0.0133 68.3 28 78.8 25 0.0189 76.3 0.0056 6 10 36 33.5 23 0.0125 68.3 28 78.8 25 0.0189 76.3 0.0064 7 12 36 37.6 24 0.014 72.2 28 78.8 25 0.0189 76.3 0.0049 8 14 36 33.5 23 0.0125 68.3 28 78.8 25 0.0189 76.3 0.0064 9 16 36 33.5 23 0.0125 68.3 28 72.3 24 0.0172 72.2 0.0047 10 18 36 33.5 23 0.0125 68.3 28 72.3 24 0.0172 72.2 0.0047 11 20 36 33.5 23 0.0125 68.3 28 72.2 24 0.0172 72.2 0.0047 Rata-rata ∆g 0.004791
8
Laporan Humidifikasi & Dehumidifikasi
4.1.2 Run 2 Q air = 50 L/h ∆P = 30 mbar
NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H
(gout-gin) (oC) (%) (oC) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 35 36.5 23 0.0129 68.3 28 72.3 24 0.0172 72.2 0.0043 2 2 37 34.6 24 0.0136 72.2 28 72.3 24 0.0172 72.2 0.0036 3 4 34 39.8 23 0.0133 68.3 28 72.3 24 0.0172 72.2 0.0039 4 6 36 39.8 24 0.0133 68.3 29 66.7 24 0.0168 72.2 0.0035 5 8 36 39.8 24 0.0133 68.3 28 78.8 25 0.0189 76.3 0.0056 6 10 36 33.5 23 0.0125 68.3 28 78.8 25 0.0189 76.3 0.0064 7 12 36 37.6 24 0.014 72.2 28 78.8 25 0.0189 76.3 0.0049 8 14 36 33.5 23 0.0125 68.3 28 78.8 25 0.0189 76.3 0.0064 9 16 36 33.5 23 0.0125 68.3 28 72.3 24 0.0172 72.2 0.0047 10 18 36 33.5 23 0.0125 68.3 28 72.3 24 0.0172 72.2 0.0047 11 20 36 33.5 23 0.0125 68.3 28 72.2 24 0.0172 72.2 0.0047 Rata-rata ∆g 0.004791 4.1.3 Run 3 Q air = 60 L/h ∆P = 30 mbar NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H
(gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 37 32 23 0.0138 72.7 27 85.6 25 0.0213 81.4 0.0075 2 2 37 32 23 0.0138 72.7 28 72.9 24 0.0191 76.9 0.0053 3 4 37 32 23 0.0138 72.7 28 79.3 25 0.0208 81.4 0.007 4 6 37 28.4 22 0.0122 68.7 28 79.3 25 0.0208 81.4 0.0086 5 8 38 26.1 22 0.0118 68.7 27.5 82.4 25 0.021 81.4 0.0092 6 10 38 33 23 0.0151 76.9 28 79.3 25 0.0208 81.4 0.0057 7 12 38 29.4 23 0.0134 72.7 28 79.3 25 0.0208 81.4 0.0074 8 14 37 32 23 0.0138 72.7 28 79.3 25 0.0208 81.4 0.007 9 16 37 35.7 24 0.0155 76.9 27.5 82.4 25 0.021 81.4 0.0055 10 18 37 35.7 24 0.0155 76.9 27.5 82.4 25 0.021 81.4 0.0055 11 20 37 35.7 24 0.0155 76.9 27.5 82.4 25 0.021 81.4 0.0055 Rata-rata 0.006745
9
Laporan Humidifikasi & Dehumidifikasi
4.1.3 Run 3 Q air = 60 L/h ∆P = 30 mbar
NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H
(gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 37 32 23 0.0138 72.7 27 85.6 25 0.0213 81.4 0.0075 2 2 37 32 23 0.0138 72.7 28 72.9 24 0.0191 76.9 0.0053 3 4 37 32 23 0.0138 72.7 28 79.3 25 0.0208 81.4 0.007 4 6 37 28.4 22 0.0122 68.7 28 79.3 25 0.0208 81.4 0.0086 5 8 38 26.1 22 0.0118 68.7 27.5 82.4 25 0.021 81.4 0.0092 6 10 38 33 23 0.0151 76.9 28 79.3 25 0.0208 81.4 0.0057 7 12 38 29.4 23 0.0134 72.7 28 79.3 25 0.0208 81.4 0.0074 8 14 37 32 23 0.0138 72.7 28 79.3 25 0.0208 81.4 0.007 9 16 37 35.7 24 0.0155 76.9 27.5 82.4 25 0.021 81.4 0.0055 10 18 37 35.7 24 0.0155 76.9 27.5 82.4 25 0.021 81.4 0.0055 11 20 37 35.7 24 0.0155 76.9 27.5 82.4 25 0.021 81.4 0.0055 Rata-rata 0.006745 4.1.4 Run 4 Q air = 30 L/h ∆P = 40 mbar NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H
(gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 37 32 23 0.0138 72.7 29 67.4 24 0.0187 76.9 0.0049 2 2 37 32 23 0.0138 72.7 28 72.9 24 0.0191 76.9 0.0053 3 4 38 29.4 23 0.0134 72.7 29 67.4 24 0.0187 76.9 0.0053 4 6 38 29.4 23 0.0134 72.7 28 72.9 24 0.0191 76.9 0.0057 5 8 38 29.4 23 0.0134 72.7 28 72.9 24 0.0191 76.9 0.0057 6 10 38 29.4 23 0.0134 72.7 28 72.9 24 0.0191 76.9 0.0057 7 12 38 29.4 23 0.0134 72.7 28 72.9 24 0.0191 76.9 0.0057 8 14 38 29.4 23 0.0134 72.7 29 67.4 24 0.0187 76.9 0.0053 9 16 37 32 23 0.0138 72.7 29 67.4 24 0.0187 76.9 0.0049 10 18 38 29.4 23 0.0134 72.7 29 67.4 24 0.0187 76.9 0.0053 11 20 38 29.4 23 0.0134 72.7 29 67.4 24 0.0187 76.9 0.0053 Rata-rata 0.005373
10
Laporan Humidifikasi & Dehumidifikasi
4.1.4 Run 4 Q air = 30 L/h ∆P = 40 mbar
NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H
(gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 37 32 23 0.0138 72.7 29 67.4 24 0.0187 76.9 0.0049 2 2 37 32 23 0.0138 72.7 28 72.9 24 0.0191 76.9 0.0053 3 4 38 29.4 23 0.0134 72.7 29 67.4 24 0.0187 76.9 0.0053 4 6 38 29.4 23 0.0134 72.7 28 72.9 24 0.0191 76.9 0.0057 5 8 38 29.4 23 0.0134 72.7 28 72.9 24 0.0191 76.9 0.0057 6 10 38 29.4 23 0.0134 72.7 28 72.9 24 0.0191 76.9 0.0057 7 12 38 29.4 23 0.0134 72.7 28 72.9 24 0.0191 76.9 0.0057 8 14 38 29.4 23 0.0134 72.7 29 67.4 24 0.0187 76.9 0.0053 9 16 37 32 23 0.0138 72.7 29 67.4 24 0.0187 76.9 0.0049 10 18 38 29.4 23 0.0134 72.7 29 67.4 24 0.0187 76.9 0.0053 11 20 38 29.4 23 0.0134 72.7 29 67.4 24 0.0187 76.9 0.0053 Rata-rata 0.005373 4.1.5 Run 5 Qair = 30 L/h ∆P = 60 mbar NO
Udara masuk Udara keluar Δg
t (menit)
Tkrg RH Tbash g H Tkrg RH Tbash g H (gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 39 30.3 24 0.0145 76.6 29 73.3 25 0.0203 80.9 0.0058 2 2 39 30.3 24 0.0145 76.6 28.5 73.1 24.5 0.0196 78.7 0.0051 3 4 40 31.3 25 0.0158 80.9 29 73.3 25 0.0203 80.9 0.0045 4 6 40 28 24 0.0141 76.6 29 73.3 25 0.0203 80.9 0.0062 5 8 40 31.3 25 0.0158 80.9 29 73.3 25 0.0203 80.9 0.0045 6 10 40 31.3 25 0.0158 80.9 29 73.3 25 0.0203 80.9 0.0045 7 12 39 28 24 0.0141 76.6 29 73.3 25 0.0203 80.9 0.0062 8 14 39 28 24 0.0141 76.6 29 73.3 25 0.0203 80.9 0.0062 9 16 39 28 24 0.0141 76.6 28 85.9 26 0.0225 85.5 0.0084 10 18 40 28 24 0.0141 76.6 28 85.9 26 0.0225 85.5 0.0084 11 20 40 28 24 0.0141 76.6 28 85.9 26 0.0225 85.5 0.0084 Rata-rata 0.0062
11
Laporan Humidifikasi & Dehumidifikasi
4.1.5 Run 5 Qair = 30 L/h ∆P = 60 mbar
NO
Udara masuk Udara keluar Δg
t (menit)
Tkrg RH Tbash g H Tkrg RH Tbash g H (gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 39 30.3 24 0.0145 76.6 29 73.3 25 0.0203 80.9 0.0058 2 2 39 30.3 24 0.0145 76.6 28.5 73.1 24.5 0.0196 78.7 0.0051 3 4 40 31.3 25 0.0158 80.9 29 73.3 25 0.0203 80.9 0.0045 4 6 40 28 24 0.0141 76.6 29 73.3 25 0.0203 80.9 0.0062 5 8 40 31.3 25 0.0158 80.9 29 73.3 25 0.0203 80.9 0.0045 6 10 40 31.3 25 0.0158 80.9 29 73.3 25 0.0203 80.9 0.0045 7 12 39 28 24 0.0141 76.6 29 73.3 25 0.0203 80.9 0.0062 8 14 39 28 24 0.0141 76.6 29 73.3 25 0.0203 80.9 0.0062 9 16 39 28 24 0.0141 76.6 28 85.9 26 0.0225 85.5 0.0084 10 18 40 28 24 0.0141 76.6 28 85.9 26 0.0225 85.5 0.0084 11 20 40 28 24 0.0141 76.6 28 85.9 26 0.0225 85.5 0.0084 Rata-rata 0.0062 4.1.6 Run 6 Q air = 30 L/h ∆P = 80 mbar NO
Udara masuk Udara keluar Δg
t (menit)
Tkrg RH Tbash g H Tkrg RH Tbash g H (gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 40 24.8 23 0.0125 72.3 29 67.3 24 0.0186 76.6 0.0061 2 2 40 28 24 0.0141 76.6 29 71.8 25 0.0197 79.3 0.0056 3 4 40 28 24 0.0141 76.6 29 71.8 25 0.0197 79.3 0.0056 4 6 41 25.8 24 0.0137 76.6 29 71.8 25 0.0197 79.3 0.006 5 8 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 6 10 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 7 12 41 25.8 25 0.0154 80.9 28 79.2 25 0.0207 80.9 0.0053 8 14 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 9 16 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 10 18 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 11 20 41 25.8 24 0.0137 76.6 28 85.9 26 0.0225 85.5 0.0088 Rata-rata 0.006582
12
Laporan Humidifikasi & Dehumidifikasi
4.1.6 Run 6
Q air = 30 L/h ∆P = 80 mbar
NO
Udara masuk Udara keluar Δg
t (menit)
Tkrg RH Tbash g H Tkrg RH Tbash g H (gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 40 24.8 23 0.0125 72.3 29 67.3 24 0.0186 76.6 0.0061 2 2 40 28 24 0.0141 76.6 29 71.8 25 0.0197 79.3 0.0056 3 4 40 28 24 0.0141 76.6 29 71.8 25 0.0197 79.3 0.0056 4 6 41 25.8 24 0.0137 76.6 29 71.8 25 0.0197 79.3 0.006 5 8 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 6 10 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 7 12 41 25.8 25 0.0154 80.9 28 79.2 25 0.0207 80.9 0.0053 8 14 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 9 16 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 10 18 41 25.8 24 0.0137 76.6 28 79.2 25 0.0207 80.9 0.007 11 20 41 25.8 24 0.0137 76.6 28 85.9 26 0.0225 85.5 0.0088 Rata-rata 0.006582 4.1.7 Run 7 Q air = 80 L/h ∆P = 30 mbar NO
Udara masuk Udara keluar Δg
t (menit)
Tkrg RH Tbash g H Tkrg RH Tbash g H (gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 40 26.9 24 0.0124 72.2 28 85.6 26 0.0205 80.6 0.0081 2 2 38 28.2 23 0.0117 68.3 28 85.6 26 0.0205 80.6 0.0088 3 4 38 31.8 24 0.0132 72.2 27.5 92.6 26.5 0.0216 82.8 0.0084 4 6 37 34.6 24 0.0136 72.2 27.5 92.6 26.5 0.0216 82.8 0.008 5 8 38 31.8 24 0.0132 72.2 28 85.6 26 0.0205 80.6 0.0073 6 10 38 31.8 24 0.0132 72.2 27.5 89 26 0.0207 80.6 0.0075 7 12 37 34.6 24 0.0136 72.2 27.5 89 26 0.0207 80.6 0.0071 8 14 37 34.6 24 0.0136 72.2 27.5 89 26 0.0207 80.6 0.0071 9 16 37 34.6 24 0.0136 72.2 27.5 89 26 0.0207 80.6 0.0071 10 18 37 34.6 24 0.0136 72.2 27 92.5 26 0.0209 80.6 0.0073 11 20 37 34.6 24 0.0136 72.2 27 92.5 26 0.0209 80.6 0.0073 Rata-rata 0.007636
13
Laporan Humidifikasi & Dehumidifikasi
4.1.7 Run 7 Q air = 80 L/h ∆P = 30 mbar
NO
Udara masuk Udara keluar Δg
t (menit)
Tkrg RH Tbash g H Tkrg RH Tbash g H (gout-gin) (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 40 26.9 24 0.0124 72.2 28 85.6 26 0.0205 80.6 0.0081 2 2 38 28.2 23 0.0117 68.3 28 85.6 26 0.0205 80.6 0.0088 3 4 38 31.8 24 0.0132 72.2 27.5 92.6 26.5 0.0216 82.8 0.0084 4 6 37 34.6 24 0.0136 72.2 27.5 92.6 26.5 0.0216 82.8 0.008 5 8 38 31.8 24 0.0132 72.2 28 85.6 26 0.0205 80.6 0.0073 6 10 38 31.8 24 0.0132 72.2 27.5 89 26 0.0207 80.6 0.0075 7 12 37 34.6 24 0.0136 72.2 27.5 89 26 0.0207 80.6 0.0071 8 14 37 34.6 24 0.0136 72.2 27.5 89 26 0.0207 80.6 0.0071 9 16 37 34.6 24 0.0136 72.2 27.5 89 26 0.0207 80.6 0.0071 10 18 37 34.6 24 0.0136 72.2 27 92.5 26 0.0209 80.6 0.0073 11 20 37 34.6 24 0.0136 72.2 27 92.5 26 0.0209 80.6 0.0073 Rata-rata 0.007636
Run ke
Q air
Q udara
∆g rata-rata
1
40
30
0.005345
2
50
30
0.004791
3
60
30
0.006745
4
80
30
0.005373
5
30
40
0.0062
6
30
60
0.006582
7
30
80
0.007636
Tabel.1 Hubungan antara
∆g rata-rata terhadap Run pada
humidifikasi
0
0.001
0.002
0.003
0.004
0.005
0.006
0.007
0.008
0.009
0
2
4
6
8
d e l t a g r a t a - r a t aRun ke
Variasi Q Laju alir air
Variasi tekanan udara
Run ke
Q air
Q udara
∆g rata-rata
1
40
30
0.005345
2
50
30
0.004791
3
60
30
0.006745
4
80
30
0.005373
5
30
40
0.0062
6
30
60
0.006582
7
30
80
0.007636
Tabel.1 Hubungan antara
∆g rata-rata terhadap Run pada
humidifikasi
Grafik.1 Hubungan antara
∆g rata-rata terhadap Run pada
humidifikasi
15
Laporan Humidifikasi & Dehumidifikasi
4.1.8 Run 8 Q air = -∆P = 20 mbar
NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H (oC) (%) (oC) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 30 45.2 21 0.012 60.9 31 41.3 21 0.0116 60.9 0.0004 2 2 30 45.2 21 0.012 60.9 33 38.8 22 0.0122 64.5 0.0002 3 4 30 45.2 21 0.012 60.9 33 38.8 22 0.0122 64.5 0.0002 4 6 30 45.2 21 0.012 60.9 33 34.4 21 0.0108 60.9 0.0012 5 8 31 46.2 22 0.013 64.5 33 34.4 21 0.0108 60.9 0.0022 6 10 31 46.2 22 0.013 64.5 33 34.4 21 0.0108 60.9 0.0022 7 12 31 46.2 22 0.013 64.5 34 31.3 21 0.0104 60.9 0.0026 8 14 32 42.3 22 0.0126 64.5 34 31.3 21 0.0104 60.9 0.0022 9 16 32 42.3 22 0.0126 64.5 34 31.3 21 0.0104 60.9 0.0022 10 18 32 42.3 22 0.0126 64.5 34 31.3 21 0.0104 60.9 0.0022 11 20 32 42.3 22 0.0126 64.5 34 31.3 21 0.0104 60.9 0.0022 Rata-rata 0.00155 4.1.9 Run 9 Q air = -∆P = 40 mbar NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 34 35.5 22 0.0118 64.5 33 43.3 23 0.0137 68.3 0.0019 2 2 34 35.5 22 0.0118 64.5 33 43.3 23 0.0137 68.3 0.0019 3 4 35 36.5 23 0.0129 68.3 32 47.2 23 0.0141 68.3 0.0012 4 6 35 36.5 23 0.0129 68.3 33.5 46.2 24 0.015 72.2 0.0021 5 8 35 36.5 23 0.0129 68.3 35 36.5 23 0.0129 68.3 0 6 10 36 33.5 23 0.0125 68.3 35.5 39.1 24 0.0142 72.2 0.0017 7 12 36 37.6 24 0.014 72.2 36 37.6 24 0.014 72.2 0 8 14 36 37.6 24 0.014 72.2 36 37.6 24 0.014 72.2 0 9 16 36 37.6 24 0.014 72.2 36 37.6 24 0.014 72.2 0 10 18 36 37.6 24 0.014 72.2 36 35.5 23.5 0.0132 70.2 0.0008 11 20 36 37.6 24 0.014 72.2 36 35.5 23.5 0.0132 70.2 0.0008 Rata-rata 0.000655
16
Laporan Humidifikasi & Dehumidifikasi
4.1.9 Run 9 Q air = -∆P = 40 mbar
NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 34 35.5 22 0.0118 64.5 33 43.3 23 0.0137 68.3 0.0019 2 2 34 35.5 22 0.0118 64.5 33 43.3 23 0.0137 68.3 0.0019 3 4 35 36.5 23 0.0129 68.3 32 47.2 23 0.0141 68.3 0.0012 4 6 35 36.5 23 0.0129 68.3 33.5 46.2 24 0.015 72.2 0.0021 5 8 35 36.5 23 0.0129 68.3 35 36.5 23 0.0129 68.3 0 6 10 36 33.5 23 0.0125 68.3 35.5 39.1 24 0.0142 72.2 0.0017 7 12 36 37.6 24 0.014 72.2 36 37.6 24 0.014 72.2 0 8 14 36 37.6 24 0.014 72.2 36 37.6 24 0.014 72.2 0 9 16 36 37.6 24 0.014 72.2 36 37.6 24 0.014 72.2 0 10 18 36 37.6 24 0.014 72.2 36 35.5 23.5 0.0132 70.2 0.0008 11 20 36 37.6 24 0.014 72.2 36 35.5 23.5 0.0132 70.2 0.0008 Rata-rata 0.000655 4.1.10 Run 10 Q air = -∆P = 60 mbar NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 35 37.7 23 0.0146 72.7 35 41.9 24 0.0163 76.9 0.0017 2 2 35 37.7 23 0.0146 72.7 35 41.9 24 0.0163 76.9 0.0017 3 4 35 37.7 23 0.0146 72.7 35 41.9 24 0.0163 76.9 0.0017 4 6 35 37.7 23 0.0146 72.7 36 38.7 24 0.0159 76.9 0.0013 5 8 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 6 10 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 7 12 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 8 14 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 9 16 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 10 18 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 11 20 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 Rata-rata 0.000327
17
Laporan Humidifikasi & Dehumidifikasi
4.1.10 Run 10 Q air = -∆P = 60 mbar
NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 35 37.7 23 0.0146 72.7 35 41.9 24 0.0163 76.9 0.0017 2 2 35 37.7 23 0.0146 72.7 35 41.9 24 0.0163 76.9 0.0017 3 4 35 37.7 23 0.0146 72.7 35 41.9 24 0.0163 76.9 0.0017 4 6 35 37.7 23 0.0146 72.7 36 38.7 24 0.0159 76.9 0.0013 5 8 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 6 10 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 7 12 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 8 14 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 9 16 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 10 18 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 11 20 35 37.7 23 0.0146 72.7 36 34.8 23 0.0142 72.7 0.0004 Rata-rata 0.000327 4.1.11 Run 11 Q air= -∆P = 80 mbar NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 37 37.6 24.5 0.0162 78.7 29 37.7 23 0.0145 72.3 0.0017 2 2 37.5 36.1 24.5 0.016 78.7 29 38.6 24 0.0157 76.6 0.0003 3 4 37 39.5 25 0.017 80.9 29 38.6 24 0.0157 76.6 0.0013 4 6 38 34.7 24.5 0.0158 78.7 29 38.6 24 0.0157 76.6 0.0001 5 8 38 34.7 24.5 0.0158 78.7 28 38.6 24 0.0157 76.6 0.0001 6 10 38.5 35.2 25 0.0164 80.9 28 37.1 24 0.0155 76.6 0.0009 7 12 38 36.3 25 0.0166 80.9 28 37.1 24 0.0155 76.6 0.0011 8 14 39 37.4 26 0.018 85.5 28 37.1 24 0.0155 76.6 0.0025 9 16 39 37.4 26 0.018 85.5 28 35.6 24 0.0153 76.6 0.0027 10 18 39 37.4 26 0.018 85.5 28 35.6 24 0.0153 76.6 0.0027 11 20 39 37.4 26 0.018 85.5 28 35.6 24 0.0153 76.6 0.0027 Rata-rata 0.000146
18
Laporan Humidifikasi & Dehumidifikasi
4.1.11 Run 11 Q air= -∆P = 80 mbar
NO
Udara masuk Udara keluar Δg
t (menit) Tkrg RH Tbash g H Tkrg RH Tbash g H (oC) (%) (oC) (kg/kg) (KJ/Kg) (oC) (%) (oC) (kg/kg) (KJ/Kg) 1 0 37 37.6 24.5 0.0162 78.7 29 37.7 23 0.0145 72.3 0.0017 2 2 37.5 36.1 24.5 0.016 78.7 29 38.6 24 0.0157 76.6 0.0003 3 4 37 39.5 25 0.017 80.9 29 38.6 24 0.0157 76.6 0.0013 4 6 38 34.7 24.5 0.0158 78.7 29 38.6 24 0.0157 76.6 0.0001 5 8 38 34.7 24.5 0.0158 78.7 28 38.6 24 0.0157 76.6 0.0001 6 10 38.5 35.2 25 0.0164 80.9 28 37.1 24 0.0155 76.6 0.0009 7 12 38 36.3 25 0.0166 80.9 28 37.1 24 0.0155 76.6 0.0011 8 14 39 37.4 26 0.018 85.5 28 37.1 24 0.0155 76.6 0.0025 9 16 39 37.4 26 0.018 85.5 28 35.6 24 0.0153 76.6 0.0027 10 18 39 37.4 26 0.018 85.5 28 35.6 24 0.0153 76.6 0.0027 11 20 39 37.4 26 0.018 85.5 28 35.6 24 0.0153 76.6 0.0027 Rata-rata 0.000146