STRUKTUR
STRUKTUR
ANALISA STRUKTUR DAN UTILITAS ANALISA STRUKTUR DAN UTILITAS
SUMBER
SUMBER : : HTTPS://WWW.AHTTPS://WWW.ARCHDAILY.COM/883858/NORRCHDAILY.COM/883858/NORTHSIDE-LIBRARY-NBBJTHSIDE-LIBRARY-NBBJ STRUKTUR ATAP PADA
STRUKTUR ATAP PADA
BANGUNAN INI AKAN
BANGUNAN INI AKAN
DIDESAIN MENJADI
DIDESAIN MENJADI
ATAP DAK ATAU
ATAP DAK ATAU
BERBENTUK DATAR.
BERBENTUK DATAR.
STRUKTUR YANG AKAN
STRUKTUR YANG AKAN
DIGUNAKAN UNTUK DIGUNAKAN UNTUK MENJADIKAN ATAP MENJADIKAN ATAP BANGUNAN BANGUNAN PERPUSTAKAAN DAN PERPUSTAKAAN DAN
TOKO BUKU INI
TOKO BUKU INI
BERBENTUK DATAR BERBENTUK DATAR (DAK) ADALAH (DAK) ADALAH STRUKTUR RANGKA STRUKTUR RANGKA BAJA. BAJA.
STRUKTUR PADA BAGIAN TENGAH BANGUNAN ADALAH
STRUKTUR PADA BAGIAN TENGAH BANGUNAN ADALAH
STRUKTUR DINDING BANGUNAN. STRUKTUR INI ADALAH
STRUKTUR DINDING BANGUNAN. STRUKTUR INI ADALAH
KOLOM DAN BALOK LEBIH TEPATNYA. FUNGSI
KOLOM DAN BALOK LEBIH TEPATNYA. FUNGSI DARIDARI
KOLOM DAN BALOK ITU SENDIRI UNTUK MENOPANG
KOLOM DAN BALOK ITU SENDIRI UNTUK MENOPANG
BANGUNAN AGAR BANGUNAN TERSEBUT DAPAT
BANGUNAN AGAR BANGUNAN TERSEBUT DAPAT
BERDIRI. SELAIN ITU FUNGSI DARI KOLOM DAN BALOK
BERDIRI. SELAIN ITU FUNGSI DARI KOLOM DAN BALOK
ADALAH MENYALURKAN BEBAN, SEHINGGA BANGUNAN
ADALAH MENYALURKAN BEBAN, SEHINGGA BANGUNAN
AKAN KOKOH. STRUKTUR DINDING YANG AKAN
AKAN KOKOH. STRUKTUR DINDING YANG AKAN
DIGUNAKAN PADA BANGUNAN PERPUSTAKAAN DAN
DIGUNAKAN PADA BANGUNAN PERPUSTAKAAN DAN
TOKO BUKU INI ADALAH STRUKTUR BETON.
TOKO BUKU INI ADALAH STRUKTUR BETON.
STRUKTUR PADA BAGIAN BAWAH ADALAH
STRUKTUR PADA BAGIAN BAWAH ADALAH
UNTUK MENOPANG BANGUNAN. STRUKTUR
UNTUK MENOPANG BANGUNAN. STRUKTUR
INI AKAN MENGALIRKAN BEBAN YANG ADA
INI AKAN MENGALIRKAN BEBAN YANG ADA
PADA BANGUNAN KE TANAH. STURKTUR
PADA BANGUNAN KE TANAH. STURKTUR
YANG AKAN DIGUNAKAN PADA BANGUNAN
YANG AKAN DIGUNAKAN PADA BANGUNAN
PERPUSTAKAAN DAN TOKO BUKU INI
PERPUSTAKAAN DAN TOKO BUKU INI
ADALAH STRUKTUR PONDASI PLAT.
UTILITAS AIR BERSIH
ANALISA UTILITAS DAN STRUKTUR
SUMBER : HTTP://MAKEADREAMS.BLOGSPOT.CO.ID/2015/12/CARA-MEMASANG-INSTALASI-AIR-BERSIH-DAN-AIR-KOTOR-UNTUK-RUMAH-TINGGAL.HTML
1. INSTALASI AIR BERSIH
SUMBER AIR
DALAM MENENTUKAN SISTEM INSTALASI AIR BERSIH YANG HARUS KALIAN KETAHUI PERTAMA ADALAH LOKASI SUMBER AIR UNTUK MENGALIRI KEBUTUHAN AIR BERSIH , BIASA NYA KETERSEDIAAN AIR BERSIH SUDAH DI SUPLAI OLEH PIPA PAM BAWAH TANAH DAN AIR TANAH LANGSUNG .
JIKA SUDAH DAPAT ANDA TENTUKAN DARI MANA KETERSEDIAAN AIR BERSIH ANDA MAKA ANDA PERENCANAAN PEMASANGAN INSTALASI AIR BERSIH SUDAH DAPAT ANDA LAKUKAN . JIKA ANDA INGIN MENGGUNAKAN PIPA SALURAN AIR PAM ANDA AKAN DI BERIKAN JALUR DISTRIBUSI UNTUK
KEBUTUHAN ANDA YANG SUDAH DI SEDIAKAN OLEH PENGELOLA AIR PAM DAN ANDA AKAN DILARANG MERUBAH UKURAN PIPA NYA SENDIRI , DAN JIKA ANDA INGIN MENGGUNAKAN AIR TANAH LANGSUNG ATAU BIASA KITA SEBUT DENGAN SUMUR ANDA HARUS MENGEBOR SENDIRI SUMBER MATA AIR ANDA
DAN MEMASANG POMPA UNTUK MENGALIRI NYA .
MODEL INSTALASI
MODEL INSTALASI DI BAGI MENJADI DUA YAITU SYTEM TERTUTUP DANSYSTEM TERBUKA . -SYTEM TERTUTUP, SYSTEM YANG DI BUAT MELINGKAR DAN ARTINYA SELURUH UJUNG PIPA TERHUBUNG ANTARA SATU DENGAN UJUNG LAINNYA . KEUNGGULAN DARI SYSTEM INI IALAH TEKANAN AIR LEBIH KUAT DAN JIKA ADA KERAN AIR YANG DI BUKA SECARA BERSAMAAN MAKA DEBIT AIR YANG
DI KELUAR KAN SAMA BESAR
-SYSTEM TERBUKASYSTEM INI MUNGKIN BANYAK DI PAKAI PENGEMBANG KARENA BIAYA
PEMASANGAN NYA YANG MURAH . NAMUN JIKA SALAH DALAM PERENCANAAN MAKA AKAN TIMBUL BANYAK MASALAH SEPERTI JIKA AIR KERAN DI GUNAKAN MAKA DEBIT AIR YANG DI KELUARKAN PUN JUMLAH NYA TIDAK SAMA DAN JIKA TERJADI KERUSAKAN PADA TITIK TERTENTU MAKA AKAN MENGGANGGU PENDISTRIBUSIAN AIR BERSIH ANDA KARENA JIKA TERJADI KERUSAKAN SATU TITIK MAKA TITIK LAIN AKAN MATI TOTAL
LETAK INSTALASI
MENURUT PROSEDUR NYA PELETAKKAN INSTALASI AIR BERSIH ADA DUA MACAM YAITU TERTANAM DAN MENEMPEL . UNTUK YANG TERTANAM SUDAH JELAS LEBIH RAPI KARENA POSISI NYA ADA DI DALAM TANAH NAMUN JIKA TERJADI KERUSAKAN AKAN MENYULITKAN KITA SENDIRI . UNTUK YANG MENEMPEL BIASANYA TERLETAK DIATAS LANTAI WALAU TIDAK RAIH NAMUN KALAU ADA KERUSAKAN ANDA DAPAT DENGA MUDAH MEMPERBAIKI NYA
BAHAN MATERIAL
BAHAN YANG DI PERGUNAKAN BIASA NYA ADALAH PIPA PVC , PIPA LOGAM DAN PIPAYANG BERBAHAN DARI STAINLEES STEEL . NAMUN UNTUK BAHAN STAINLEES STEEL INI JARANG DI PERGUNAKAN KARENA AGAK LEBIH MAHAL . BAHAN - BAHAN TERSEBUT MEMILIKI KEKURANGAN DAN KELEBIHAN MASING - MASING
UTILITAS AIR KOTOR
ANALISA UTILITAS DAN STRUKTUR
JARINGAN AIR KOTOR DALAM BANGUNAN TERBAGI MENJADI TIGA KELOMPOK, YAITU :
LIMBAH CAIR, BERUPA AIR KOTOR YANG BERASAL DARI FLOOR DRAIN KAMAR MANDI, WASTAFEL, DLL., LIMBAH PADAT, YANG BERASAL DARI KLOSET KAMAR MANDI,
AIR HUJAN.
PADA PENANGANAN LIMBAH CAIR, AIR KOTOR YANG BERASAL DARI FLOOR DARAIN KAMAR MANDI, WASTAFEL, TEMPAT CUCI PIRING DSB PADA TIAP LANTAI DISALURKAN KE BAWAH MELALUI PIPA MENUJU KE LANTAI DASAR, LALU DISALURKAN MENUJU BAK KONTROL. KEMUDIAN AIR DIALIRKAN MENUJU SUMUR RESAPAN SEBELUM DIBUANG KE SALURAN KOTA.
PADA PENANGANAN LIMBAH PADAT, KOTORAN YANG BERASAL DARI KLOSET TIAP LANTAI DISALURKAN MELALUI PIPA LIMBAH PADAT SECARA VERTIKAL MENUJU KE LANTAI DASAR YANG KEMUDIAN LANGSUNG DISALURKAN KE DALAM SEPTIC TANK. PIPA LIMBAH PADAT YANG MELINTANG SECARA HORIZONTAL HARUS MEMILIKI KEMIRINGAN MINIMAL 5% TIAP 1 METER UNTUK MEMINIMALKAN RESIKO TERSUMBAT. KARENA HAL INI, PENEMPATAN SEPTIC TANK JUGA PERLU DIPERHATIKAN, APABILA JARAKNYA SEMAKIN JAUH DARI LETAK KLOSET LANTAI DASAR, MAKA PENEMPATAN SEPTIC TANK AKAN MEMBUTUHKAN KEDALAMAN YANG SEMAKIN BESAR. PADA SEPTIC TANK, LIMBAH KEMUDIAN DITAMPUNG DAN DIENDAPKAN, LALU AIR YANG TERSISA DIALIRKAN KE SUMUR RESAPAN. UNTUK PENEMPATAN SEPTIC TANK BESERTA RESAPANNYA, SEBAIKNYA DILETAKKAN BERJAUHAN DENGAN SUMUR ARTESIS MAUPUN GORUND WATER TANK, MINIMAL BERJARAK 15 METER. HAL INI DILAKUKAN AGAR JARINGAN AIR BERSIH TIDAK TERCEMAR LIMBAH DARI SEPTIC TANK.
UNTUK PENANGANAN AIR HUJAN, DIGUNAKAN TALANG YANG DISESUAIKAN DENGAN BENTUK ATAP, YANG KEMUDIAN DIALIRKAN SECARA VERTIKAL MELALUI PIPA MENUJU KE BAK KONTROL YANG SAMA DENGAN YANG DIGUNAKAN PADA PENANGANAN LIMBAH CAIR DI LANTAI DASAR.
SISTEM KEBAKARAN
ANALISA UTILITAS DAN STRUKTUR
SUMBER : HTTPS://TROPICALARCHITECTBLOG.WORDPRESS.COM/2016/08/08/UTILITAS-BANGUNAN-UMUM-SEDERHANA-RUSUNAWA/ BEBERAPA PERANGKAT PEMADAM KEBAKARAN ATAU PENCEGAHAN KEBAKARAN YANG TERDAPAT PADA
BANGUNAN RUSUNAWA ANTARA LAIN :
PENDETEKSI GEJALA KEBAKARAN (DETEKTOR) ALARM ATAU SIRINE KEBAKARAN
SPINKLER HIDRANT PENDETEKSI GEJALA KEBAKARAN YANG DIPERLUKAN BERUPA : DETEKTOR ASAP DETEKTOR PANAS DETEKTOR API
PELETAKAN DETEKTOR BERAPA PADA LANGIT-LANGIT PADA SETIAP RUANGAN DI RUSUNAWA SERTA DI LORONG DENGAN JARAK TERTENTU. DETEKTOR AKAN MENDETEKSI ADANYA ASAP ATAU TANDA-TANDA LAIN KEBAKARAN KEMUDIAN SECARA OTOMATIS MENGAKTIFKAN ALARM ATAU SIRINE KEBAKARAN, NAMUN JIKA ALARM OTOMATIS TIDAK BERFUNGSI TERDAPAT TUAS MANUAL YANG DITARIK UNTUK MENGAKTIFKAN SIRINE KEBAKARAN. KEMUDIAN SPRINKLER AKAN BEKEJA MENYEMPROTKAN AIR KETIKA ALARM BERBUNYI. AIR YANG DIGUNAKAN SPRINKLER BERASAL DARI ROOF TANK UNTUK PEMADAMAN
PADA INSTALASI AIR BERSIH.
SELAIN SPRINKLER TERDAPAT PULA HIDRANT YANG TERDAPAT MASING -MASING DUA DILETAKKAN DI POJOK LORONG PADA SETIAP LANTAI, SUMBERNYA DARI ROOF TANK PEMADAMAN KEBAKARAN PADA INSTALASI AIR BERSIH. PADA SAAT TERJADI KEBAKARAN PARA PENGHUNI MENGGUNAKAN TANGGA DARURAT YANG BERADA DI SISI KANAN DAN KIRI BANGUNAN UNTUK MELAKUKAN EVAKUASI.
PENANGKAL PETIR DAN INSTALASI LISTRIK
ANALISA UTILITAS DAN STRUKTUR
SUMBER : HTTP://BLOG.KANGMIFTAH.COM/2014/02/CARA-PASANG-SAKLAR-GENSET-MANUAL.HTML INSTALASI PENANGKAL PETIR
KARENA BENTUK BANGUNAN MEMANJANG, PENANGKAL PETIR YANG DIGUNAKAN PADA BANGUNAN INI ADALAH PENANGKAL PETIR TIPE SANGKAR FARADAY. PENANGKAL PETIR SANGKAR FARADAY TERDIRI DARI :
BATANG PENANGKAL PETIR, BERUPA BATANG – BATANG LOGAM BERUJUNG RUNCING YANG DILETAKKAN PADA BAGIAN TERATAS ATAP BANGUNAN,
KABEL KONDUKTOR, YANG MERUPAKAN KABEL PENYALUR PETIR YANG DIPASANG PADA SISI LUAR BANGUNAN DAN DIBERI LAPISAN PELINDUNG / ISOLATOR,
TEMPAT PEMBUMIAN / GROUNDING, BERUPA BATANG ELEKTRODA TEMBAGA YANG DITANAM DI DALAM TANAH.
INSTALASI LISTRIK
PADA BANGUNAN PERPUSTAKAAN DAN TOKO BUKU INI MEMILIKI 2 INSTALASI LISTRIK YANG
DIGUNAKAN YAITU SALURAN LISTRIK DARI PLN DAN SALURAN LISTRIK DARI GENSET. LISTRIK DARI PLN BERTEGANGAN TINGGI AKAN DISALURKAN PADA JARINGAN KABEL LISTRIK, LALU DILANJUTKAN OLEH TRANSDORMATOR PADA GARDU-GARDU LISTRIK MENJADI BERTEGANGAN MENENGAH, LALU TEGANGAN RENDAH AKAN DILANJUTKAN DARI TRAFO MENUJU KE BANGUNAN.
TRANSPORTASI VERTIKAL
ANALISA UTILITAS DAN STRUKTUR
SUMBER : HTTPS://MATERIARSITEKTUR.BLOGSPOT.CO.ID/2016/04/PERENCANAAN-TANGGA-DARURAT-PADA-BANGUNAN.HTML DAN HTTP://ARSITEKISTN.BLOGSPOT.CO.ID/2011/05/CARA-KERJA-LIFT-PADA-GEDUNG.HTML TANGGA DARURAT MERUPAKAN TANGGA PADA BANGUNAN YANG BARU AKAN DIGUNAKAN PADA SAAT-SAAT
TERTENTU SAJA, UTAMANYA KETIKA TERJADI BENCANA DI DALAM BANGUNAN, SEPERTI KEBAKARAN. TANGGA DARURAT LEBIH MEMENTINGKAN FUNGSI DARI PADA ESTETISNYA. UMUM- NYA LETAK TANGGA DARURAT PADA RUANGAN KHUSUS DAN TIDAK AKAN DI GUNAKAN JIKA KONDISI BANGUNAN NORMAL. DESAIN TANGGA DARURAT LEBIH DIFOKUSKAN PADA PENEM- PATAN YANG PALING MUDAH DIJANGKAU SERTA TERBEBAS DARI API APABILA TERJADI BENCANA DI DALAM BANGUNAN DAN HARUS MEMILIKI PENGHAWAAN YANG MAKSIMAL.
PINTU DARURAT DAN TANGGA DARURAT HARUS DITEMPATKAN SEDEMIKIAN RUPA SEHINGGA MUDAH DICAPAI DAN DAPAT MENGELUARKAN SELURUH PENGHUNI DALAM WAKTU 2,5 MENIT. PINTU DARURAT HARUS MEMPUNYAI TANDA ATAU SINYAL PENERANGAN YANG BERTULISKAN KELUAR DI ATASNYA DAN MENGHADAP KE KORIDOR (DEPARTEMEN PEKERJAAN UMUM, 1987: 11-14).
1. AKSES, TANGGA LUAR HARUS DIIJINKAN MENUJU KE ATAP DARI BAGIAN LAIN BANGUNAN ATAU BANGUNAN YANG BERSEBELAHAN, APABILA KONSTRUKSINYA TAHAN API, DISANA ADA SARANA JALAN KELUAR YANG AMAN DAN MENERUS DARI ATAP, DAN SEMUA PERSYARATAN YANG WAJAR LAINNYA UNTUK KESELAMATAN JIWA
DIJAGA.
2. BALKON YANG MENUJU PINTU JALAN KELUAR HARUS MENDEKATI PERMUKAAN LANTAI BANGUNAN.
3. PROTEKSI VISUAL, TANGGA LUAR HARUS DISUSUN UNTUK MENGHINDARI KESULITAN PENGGUNAAN TANGGA OLEH ORANG YANG TAKUT TERHADAP TEMPAT TINGGI. 4. PEMISAHAN DAN PROTEKSI DARI TANGGA LUAR, TANGGA LUAR HARUS DIPISAHKAN
DARI BAGIAN DALAM BANGUNAN OLEH DINDING DENGAN TINGKAT KETAHANAN API YANGDIPERSYARATKAN UNTUK RUANG TANGGA TERTUTUP DENGAN BUKAAN TETAP ATAU DAPAT MENUTUP SENDIRI DAN TERPROTEKSI.
5. PROTEKSI TERHADAP BUKAAN, SEMUA BUKAAN DIBAWAH TANGGA LUAR HARUS DIPROTEKSI DENGAN SUATU RAKITAN YANG MEMPUNYAI TINGKAT KETAHANAN API 45/45/45.
6. GENANGAN AIR, TANGGA DAN BORDES LUAR HARUS DIRANCANG UNTUK MEMINIMALKAN GENANGAN AIRPADA PERMUKAANNYA.
7. KETERBUKAAN, TANGGA LUAR HARUS SEDIKITNYA 50% TERBUKA PADA SATU SISI DAN HARUS DISUSUN UNTUK MEMBATASI MENGUMPULNYA ASAP.
PADA SISTEM GEARED ATAU GEARLESS (YANG MASING-MASING DIGUNAKAN PADA INSTALASI GEDUNG DENGAN KETINGGIAN MENENGAH DAN TINGGI), KERETA ELEVATOR TERGANTUNG DI RUANG LUNCUR OLEH BEBERAPA STEEL HOIST ROPES, BIASANYA DUA PULI KATROL, DAN SEBUAH BOBOT PENGIMBANG (COUNTERWEIGHT). BOBOT KERETA DAN COUNTERWEIGHT MENGHASILKAN TRAKSI YANG MEMADAI ANTARA PULI KATROL DAN HOIST ROPES SEHINGGA PULI KATROL DAPAT MENGGEGAM HOIST ROPES DAN BERGERAK SERTA MENAHAN KERETA TANPA SELIP BERLEBIHAN. KERETA DAN COUNTERWEIGHT BERGERAK SEPANJANG REL YANG VERTIKAL AGAR MEREKA TIDAK BERAYUN-AYUN.
MESIN UNTUK MENGGERAKKAN ELEVATOR TERLETAK DI RUANG MESIN YANG BIASANYA TEPAT DI ATAS RUANG LUNCUR KERETA. UNTUK MEMASOK LISTRIK KE KERETA DAN MENERIMA SINYAL LISTRIK DARI KERETA INI, DIPERGUNAKAN SEBUAH KABEL LISTRIK MULTI-WIRE UNTUK MENGHUBUNGKAN RUANG MESIN DENGAN KERETA. UJUNG KABEL YANG TERIKAT PADA KERETA TURUT BERGERAK DENGAN KERETA SEHINGGA DISEBUT SEBAGAI “KABEL BERGERAK (TRAVELING CABLE)”.