No. Jumlah

1 - External Dimension (w x d x h): minimum 1200 x 650 x 800 mm 1

- Internal Dimension (w x d x h): minimum 1100 x 600 x 550 mm

- Microprocessor control system

- Air Flow : 0.45 m/s (90 fpm) at initial setpoint

- Main Filter : ULPA 99.9999% efficient at particle sizes between 0.1 to 0.3 um

- Pre Filter: Disposible and non-washable polyester fiber

- ISO Class 3 air cleanliness as per ISO 14644.1

-- Workbench: Stainless steel - Side walls: tempered glass - Noise Level: < 65 dBA

- Antimicrobial coating on all painted surfaces

- Include

- Installation

- Training

- Guarantee min a year

- Original operation manual

- Base stand

- Analog thermohygrometer for room controlling

An intelligent blower system which maintains airflow as the filter becomes loaded, ensuring optimum efficiency and product protection.

SPESIFIKASI TEKNIS

PENGADAAN ALAT LABORATORIUM (LELANG ULANG)

BALAI BESAR POM DI JAYAPURA TAHUN 2017

Nama Alat Laboratorium Spesifikasi

(2)

2 - Minimal capacity 100 L 1 - Dimensi Interior (W x D x H) min 450 x 400 x 450 mm

- Temperature 5°C Above ambient up to +80°C - Digital LED display

- Programmable controller

- Adjustable shelves, including minimal 2 removable / adjustable stainless steel shelves - Interior material: Stainless steel

- Exterior material: Stainless steel atau Epoxy coated steel

- Completed with alarm system if setting temperature out of control - Double door protection with inner glass door

- 230 V, 50/60 Hz

- Analog thermohygrometer for room controlling

3 - Working-temperature range from -0°C up to +60°C or better 1

- Volume : min 100 L

- Setting accuracy temperature : 0,1 °C - Digital display control

- Double door protection with inner glass door - Interior chamber material: stainless steel

- Adjustable shelves, including minimal 2 removable / adjustable stainless steel shelves - Programmable controller

- Exterior material: Stainless steel atau Epoxy coated steel - Alarm : visual and acoustic

(3)

- Include - Installation - Training

- Guarantee min a year - Original operation manual

- Analog thermohygrometer for room controlling - USB hub

- Software program

4 - Kapasitas max 2200 g 2

- Kapasitas minimum 14 g - Readability 0.01 g - Reproducibility 0.01 g

- Pan size min 170 mm x 170 mm in square atau 180 mm in diameter - Linearity ± 0.02 g

- Operating temperature range 10° to 30°C atau range lebih lebar lebih baik - Automatic internal calibration

- Response time (average) max 3 Sec

- Digital display with clear readout, backlit display

- Dimensions range (W x D x H): (200-355) mm x (270-360) mm x (95-230) mm - AC power source / power requirements AC adapter, 220 V - 240 V

- F e ue y 8 – Hz

- Tracable data, with built-in data - Include:

- Manual

- Minimal 1 year warranty

- Analog thermohygrometer for room controlling

5 - Dimension minimal W: 700 mm, D: 700 mm, H: 1500 mm 1

- Total capacity for freezer and refrigerator minimal 425 L - Adjustable tempered glass shelves

(4)

6 - Digital operation 2 - Electronic timer, electronic temperature (heating)

- Tank capasity minimum 20 L

- Outside dimension (LxWxH) minimum 500 x 300 x 400 mm - Tank Inside dimension (LxWxH) minimum 500 x 290 x 130 mm - Tank material : Stainless steel

- Function : Sonicator and degasser

- Average input power 230 V, Power consumption for ultrasonic and heating maximum 1000 W

- Heating range up to 60°C. - Frequency : Max 60 kHz - Including:

- Basket Stainless steel - Minimum 1 year waranty - Manual book

7 - Stand mixer yang bisa dilepas digunakan sebagai hand mixer 1

- Adjustable speed

- Dilengkapi dengan wadah mangkok yang dapat dilepas - Mangkok dapat berputar jika digunakan pada stand mixer

- Bagian bawah mangkok berbentuk lengkungan, mudah dibersihkan, tahan panas, kuat dan tidak korosif

- Dilengkapi dengan beaters

8 - Material : 304 Stainless steel 2

- Ukuran : min p: 85 cm, l: 45 cm, t: 85 cm

- Tipe susunan trolley : 3 susun dengan pembatas dipinggirnya (side wall) dengan tinggi 100 - 120 mm.

-Tipe roda : 4 roda dengan sistem perputaran 360° dan pemberhentian roda trolley - Maximum Load : 100 kg

Mixer

(5)

9 - Aspirate speeds: min 6 3 - Dispense speeds: min 6 (+ Gravity Dispense)

- Weight: ±220 g

- Power Supply Input : 220 V- 240 V AC - Battery: lithium-Ion

- Nosecone pipet holder: autoclavable silicone rubber

- Compatible with all major brands of glass or plastic serological pipets 1 ml - 100 ml.

10 Oven - Volume minimal 240 L 1

- Dimensi Interior (W x D x H) min 500 x 500 x 800 mm - Dimensi Exterior (W x D x H) min 650 x 680 x 1100 mm

- Temperature range 10° C Above ambient up to + 300° C atau range lebih lebar lebih baik - Programmable controller

- Double door protection with inner glass door - Electrical supply 230 V, 50/60 Hz

- Interior material: Stainless steel - Exterior material: stainless steel - LED display

- 2 circulation fans

- Adjustable shelves, including minimal 2 removable /adjustable stainless steel shelves - Timer function

- Include - Installation - Training

- Guarantee min a year - Original operation manual - Thermocouple Type K - Software program - USB hub

11 - 18 mm, 50 lubang, terbuat dari stainless steel SS304. 5

- Sesuai untuk tabung reaksi ukuran diameter 16,5 mm

- Anti karat, bagian rangkanya stainless steel berbentuk bulat dan tidak tajam. - Mudah dibersihkan

Pipette Controller Electric

(6)

12 1. Column Derivatitation Approvals : AOAC 2005 1

Alat derivatisasi Photochemical reactor for analysis of aflatoxins by HPLC

Rentang deteksi 0.1 - 100 ppb untuk B1, B2, G1, dan G2 atau rentang lebih lebar lebih baik Rentang deteksi 0.5 - 100 ppb untuk M1 atau rentang lebih lebar lebih baik

2. Immuno affinity column can isolate aflatoxin B1, B2, G1, G2, & M1

Immuniaffinity colums for sample clean up prior to the analysis of aflatoxin M1, B1, B2, G1, G2 using HPLC

3. Vacuum Manifold or pump/standar package - maksimum untuk 6 sampel

- stand pump plus pendorong 4. Include:

a. installation and training b. original operational manual, c. quarantee min a year + spare part,

d. kolom C 18 5 µm (4.6 x 250 mm) compatible with analysis aflatoxin M1, B1, B2, G1, G2 using for HPLC

e. blender stainless steel

f. baku B1, B2, G1, G2, dan M1 bersertifikat g. Analog thermohygrometer for room controlling

13 Specifications : 1

Power Supply: 220 - 240 V Micotoxin / Aflatoxin Test set secara KCKT *)

Fumehood *)

(7)

14 1 Pompa : 1 unit 2

Tipe : Parallel atau Serial double plunger Rentang laju alir : 0.001-10 ml/menit atau lebih baik Akurasi laju alir : ± 1% atau lebih kecil

Presisi laju alir : 0.1% RSD atau lebih kecil Gradient accuracy : ±1% atau lebih kecil

Jumlah wadah fase gerak : minimal 4 Pressure : 40 MPa atau lebih besar

2 Detektor : 1 unit

Lampu : D2 (Deuterium) lamp, W (Tungsten) lamp

Detektor : UV-Vis dan PDA Rentang panjang gelombang Detektor UV-Vis : 190-900 nm atau lebih besar

Rentang panjang gelombang Detektor PDA : 190-800 nm atau lebih besar Wavelength accuracy : ± 1 nm atau lebih Kecil

3 Autosampler : 1 unit

Rentang Volume injeksi : 0.1 µl s/d 100µl or better

Presisi volume injeksi : RSD, maksimum 0.3% (untuk penginjeksian 20 µl); Autosampler with cooler: suhu 4°C- 40 °C atau range lebih lebar lebih baik

4

Degasser : 1 unit (modul terpisah atau terintegrasi dengan sistem pompa)

"Workstation

Hardware compatible with HPLC Proc Intel Core i5 (up to 3,6 GHz, 6 MB)

Dedicated VGA 2 GB, RAM 4 GB,

HDD 1 TB DVD-RW

LED Monitor 18,5 inch Laser printer

(8)

5 I lude: Kolo C 8 , X , μ uah; Kolo C 8 , X , μ buah, training, original operational manual, quarantee min a year, installation, factory sertificate, dust cover 1 set, tools kit 1 set, UPS min 5 kva, vial max. 2 ml (sesuai dengan kompartemen sampel pada alat) 100 pcs, 'Analog thermohygrometer for room controlling

6 Oven : 1 unit

Rentang suhu : 20 °C-80 °C atau range lebih lebar lebih baik Presisi suhu : ± 0,1 °C

- Power Supply: 220 - 240 V

15 - Capa ity: 8 ha el volu e: , , , , μl 2

- System: semi automated up to 18 samples simultaneously - Plate dimension: 10 x 10 cm, 10 x 20 cm

- Digital Temperature Readout - Power Supply: 220 - 240 V - Include:

- Sy i ge μl: uah - Sy i ge μl: uah - Sy i ge μl: uah - Sy i ge μl: uah - Sy i ge μl: uah

- Analog thermohygrometer for preparation room controlling Terdapat pengatur kecepatan penotolan sampel

- Caransi min 1 tahun - Manual book - Uji Fungsi alat

- Plate dimension: 10 x 10 cm, 10 x 20 cm diubah menjadi :

- Plate dimension: 20 x 20 cm Multispotter *)

(9)

16 - Applications: size reduction, homogenisation, and mixing 1 - Working principle: cutting

- Knife material: stainless steel for standard laboratory use - Grinding bowl sizes: minimal 2 pieces

- Bowl material: stainless steel for standard laboratory use - Max. feed size: > 10 mm

- Max sample quantity: < 700 ml - Final fineness: < μ - Grinding process: Dry and wet

- Rotational speed of main disk: minimal 400 rpm - Electrical details: 220 - 240 V

- Application: size reduction for medicine/pharmaceuticals, containing water/fat/oil, dry, soft and medium-hard products (for laboratory use)

- Guarantee: min 1 year - Include:

- Manual book/guide book - COO, COM from factory

Referensi

Dokumen terkait

Di dalam rumah pengolahan tersebut terdapat proses sortasi awal, pulping, fermentasi, penjemuran awal yang akan mengolah buah kopi cherry menjadi biji kopi gabah.. 2

Konsep yang diusulkan adalah mitra (pengusaha travel) membuka kesempatan kepada konsumen untuk mendaftar menjadi membernya. Dengan menjadi member, seorang konsumen

Untuk dapat melaksanakan kegiatan pengabdian pada masyarakat maka dilakukan tahan persiapan dan pelaksanaan, dimana tahap ini bertujuan untuk mengetahui menganalisa

MODEL PELATIHAN KREATIVITAS VOKAL BERTEMA UNTUK ANAK USIA DINI DI PURWA CARAKA.. MUSIC STUDIO

Tabel .8 pengaruh faktor keuangan terhadap tingkat stres mahasiswa S1 Keperawatan semester II dalam adaptasi proses pembelajaran Stikes Muhammadiyah Gombong

I Kadek Ardana (Ketua Dadia Pasek Gelgel Pegatepan Banjar Kengetan, Desa Pakraman Kengetan, Desa Singakerta, Kecamatan

1. PDRB berpengaruh positif dan signifikan terhadap DPK. Peningkatan PDRB mencerminkan bahwa perekonomian daerah dan perekonomian rakyat yang semakin baik meningkatkan

[r]