ATOM INDONESIA JOURNAL
Author’s Response toward Associate Editor's Report
Article No. : 537
Title of Paper : High Temperature Oxidation Behaviour of Fe-Cr Steel in Air at 1000-1200K Comment on Descriptions
Criteria Evaluation
Associate editor's evaluation
Author’s Response
Yes No Comments
1. Originality of the article
Free of Plagiarism/Similarity(max 20%) v No Comment
New article/not yet Published (presented/ in proceeding max 30%)v
No Comment
2. Related to nuclear/atomic
science and technology v No Comment
3. References
The number of references at least 10, at most 20 for nonreview papers; at least 26 for review papers.v
New references have been added and rearanged
The use of recent references80 % (maximum 5 years ago) x
Only 9 of 13 references (69 %) are from 2011 or later. Please add recent references/reduce less recent ones.
New references have been added (Recent references = 80%)
Type of the references (primarily, secondary etc.) 85% from journals
v
No Comment
DOI reference (traceable) xPlease add DOIs to make the references more traceable. For instance, for [2] (Nikrooz, Zandrahimi and Ebrahimifar), it would be
http://dx.doi.org/10.1007/s1097 1-012-2786-7 .
DOIs have been added
Reference style standard:Elsevier numeric without title v
Please use commonly accepted abbreviations for publication names. For instance,
“International Journal of Hydrogen Energy” may become
“Int J Hydrogen Energ”. Some examples are in
https://www.elsevier.com/__dat a/promis_misc/BMCL_Abbrevi ations.pdf and
https://images.webofknowledge.
com/WOKRS520B4.1/help/WO S/A_abrvjt.html .
Corrected as suggested
When reference has more than 3 Authors, write only 3 names, et al.x
For Ref. [4], four authors are named. It should be changed to name just the first three: should only be given as: T. Hosono,
Corrected as suggested
C.C. Su, R. Delinom, et al., instead of the first four.
Article follows the Atom Indonesia template and guidelinesx
Nominally, the article appears to follow the templates. However, it is unorthodox in its use of frames and its composition of figures from smaller elements (superimposing bitmaps and texts in unusual ways, etc.) that potentially makes it difficult to format the paper for publication.
The recent manuscript has been corrected according to Atom Indonesia template and guidelines.
Table (clear, without verticalline) v Not applicable, as there are no
tables here.
No Comment
Figure (clear, min 300 dpi) xIt appears that none of the figures reaches 300 dpi (for example, Fig. 2a, size 0.94” × 0.92”, and resolution 108 × 105 px, thus its pixel density = resolution / size = 115 × 114 dpi). Please use higher- resolution images.
The original figures have been enclosed after the text.
Final recommendation:
1. Continue review process [ ] 2. Return to the Author [ v ] 3. Reject [ ]
Comments:
The article should be returned to the authors to allow for the necessary improvements to be made.
The recent manuscript has been corrected according toAssociate Editor’s Report